Loading...
HomeMy WebLinkAboutDAQ-2024-0072981 DAQC-PBR145750001-24 Site ID 14575 (B1) MEMORANDUM TO: FILE – UINTA WAX OPERATING, LLC – ULT 13-26-3-1E THROUGH: Rik Ombach, Minor Source Oil and Gas Compliance Section Manager FROM: Chris Jensen, Environmental Scientist DATE: March 14, 2024 SUBJECT: OIL AND GAS PERMIT-BY-RULE EVALUATION INSPECTION DATE: March 13, 2024 SOURCE LOCATION: ULT 13-26-3-1E Lat:40.187925 Long: -109.857496 Business Office: 6000 Western Place, Suite 1000 Fort Worth, TX 76107-4664 SOURCE TYPE: Tank Battery Rural Uintah County API: 4304751887 SOURCE CONTACTS: Aimee Cole, Local Contact Phone: 720-384-7365, Email: acole@finleyresources.com Kaylene Bridwell, Corporate Environmental Contact Phone: 405-496-7308, Email: kaylene.bridwell@uintawax.com OPERATING STATUS: Operating PROCESS DESCRIPTION: Oil and gas products are brought to the surface. These products go through a separator where the oil and any water products are sent to storage tanks and the gas is used to power equipment on site (pump jack engine, tank heater, separator, flare, combustor, etc.) Any remaining gas is sent to a pipeline that feeds a local gas plant. The oil and process water in the storage tanks is loaded into tanker trucks and hauled off-site for processing and disposal. APPLICABLE REGULATIONS: Utah Administrative Code (UAC) R307-500 Series for the Oil and Gas Industry, and UAC R307-201: Emission Standards: General Emission Standards; and UAC R307-150: Emission Inventories, and NSPS (60) JJJJ. 2 SOURCE EVALUATION: Site Type: PBR- Uncontrolled No Flare Controls Site powered by Engine DOGM current 12 month rolling production is: 583 BBLs. Utah Statute R307-506 requires a source with throughput greater than 8,000 BBLs to have controls. REGISTERED EQUIPMENT: Pneumatic Controllers Continuous bleed natural gas-driven pneumatic controllers are in compliance with 40 CFR 60.5390 or 60.5390a as applicable. Exemptions to tagging and record keeping requirements apply to controllers existing before 12/1/2015. [R307-502-4] In Compliance. This source does not use continuous bleed natural gas-driven pneumatic controllers. Oil and Gas Industry Registration Requirement Registration has been updated within 30 days of a company name change, removal or addition of control devices, or termination of operations. [R307-505-3(3)] In Compliance. Storage Vessels Thief hatches are kept closed and latched. [R307-506-4(1)] In Compliance. All hatches were found closed at the start of the evaluation. Upon modification, the well site was re-evaluated against the thresholds of R307-506-4(2). [R307-506-4(6)] In Compliance. The DAQ did not identify any modifications or unauthorized equipment. Records for each of the following are kept for three years: Storage vessel vent system inspections (openings, thief hatches, pressure relief devices, bypasses, etc.), if required Monthly crude oil throughput Emission calculations, actuals and sampling data when used to justify an exemption to storage vessel rules Emergency storage vessel usage (dates used, emptied, and volumes), if not controlled per R307-506-4(2). [R307-506-5] In Compliance. Monthly crude production totals were provided. 3 Natural Gas Engines Affected engine exhaust vents are vertical and unrestricted. Stacks are 8' or greater if the site horsepower rating is 151 to 305 Stacks are 10' or greater if the site horse power rating is 306 or greater. [R307-510-4(3)] In Compliance. Visible Emissions Visible emissions, except for unavoidable irregularities that do not exceed three minutes, are within the following opacity limits: Installations constructed on or before 4/25/1971 40% Installations constructed after 4/25/1971 20% Gasoline engines 0% Diesel engines manufactured after 1/1/1973 20% Diesel engines manufactured before 1/1/1973 40% Note: Required VOC control devices shall have no visible emissions per R307-508-3. [R307-201-3] In Compliance. No visible emissions were detected. Emission Inventory: An emissions inventory has been submitted within the past three years. [R307-150-9(1)] In Compliance. The Operator submitted for the 2020 emissions inventory. Applicable Federal Regulations: NSPS (Part 60) JJJJ: Standards of Performance for Stationary Spark Ignition Internal Combustion Engines. [40 CFR 60 Subpart JJJJ] Not Observed. Engine maintenance is the only requirement left for this source. Records were not reviewed at this time. The DAQ has a stack test for the engine on file. PREVIOUS ENFORCEMENT ACTIONS: No enforcement actions within the past five years. COMPLIANCE STATUS & RECOMMENDATIONS: In regards to: ULT 13-26-3-1E: In Compliance – The source was inspected by AVO, and with an OGI camera, was found to be well-kept with no visible or fugitive emissions. RECOMMENDATION FOR NEXT INSPECTION: The DAQ has no Recommendations for the next inspector other than what are customary. The DAQ recommends the inspection frequency of this source be reduced.