HomeMy WebLinkAboutDAQ-2024-0072961
DAQC-PBR145580001-24
Site ID 14558 (B1)
MEMORANDUM
TO: FILE – UINTA WAX OPERATING, LLC – ULT 10-26-3-1E
THROUGH: Rik Ombach, Minor Source Oil and Gas Compliance Section Manager
FROM: Chris Jensen, Environmental Scientist
DATE: March 14, 2024
SUBJECT: OIL AND GAS PERMIT-BY-RULE EVALUATION
INSPECTION DATE: March 13, 2024
SOURCE LOCATION: ULT 10-26-3-1E
Lat:40.187633 Long: -109.843659
Business Office:
6000 Western Place, Suite 1000
Fort Worth, TX 76107-4664
SOURCE TYPE: Tank Battery
Uintah County
API: 4304751875
SOURCE CONTACTS: Aimee Cole, Local Contact
Phone: 720-384-7365, Email: acole@finleyresources.com
Kaylene Bridwell, Corporate Environmental Contact
Phone: 405-496-7308, Email: kaylene.bridwell@uintawax.com
OPERATING STATUS: Operating
PROCESS DESCRIPTION: Oil and gas products are brought to the surface. These products
go through a separator where the oil and any water products are
sent to storage tanks and the gas is used to power equipment on
site (pump jack engine, tank heater, separator, flare, combustor,
etc.) Any remaining gas is sent to a pipeline that feeds a local
gas plant. The oil and process water in the storage tanks is
loaded into tanker trucks and hauled off-site for processing and
disposal.
APPLICABLE REGULATIONS: Utah Administrative Code (UAC) R307-500 Series for the Oil
and Gas Industry, and UAC R307-201: Emission Standards:
General Emission Standards; and UAC R307-150: Emission
Inventories, and 40 CFR 60 Subpart JJJJ.
2
SOURCE EVALUATION: Site Type: PBR- Uncontrolled
Voluntarily Controlled by Flare
Site powered by Engine
DOGM current 12 month rolling production is: 3,371 BBLs.
Utah Statute R307-506 requires a source with throughput greater
than 8,000 BBLs to have controls.
REGISTERED EQUIPMENT:
Pneumatic Controllers
Continuous bleed natural gas-driven pneumatic controllers are in compliance with 40 CFR 60.5390 or
60.5390a as applicable. Exemptions to tagging and record keeping requirements apply to controllers
existing before 12/1/2015. [R307-502-4]
In Compliance. This source does not use continuous bleed natural gas-driven pneumatic
controllers.
Oil and Gas Industry Registration Requirement
The source is registered with the DAQ. [R307-505-3(3)]
In Compliance.
Registration has been updated within 30 days of a company name change, removal or addition of control
devices, or termination of operations. [R307-505-3(3)]
In Compliance.
Storage Vessels
Thief hatches are kept closed and latched. [R307-506-4(1)]
In Compliance. All hatches were found closed at the start of the evaluation.
Upon modification, the well site was re-evaluated against the thresholds of R307-506-4(2).
[R307-506-4(6)]
In Compliance. The DAQ did not identify any modifications or unauthorized equipment.
Natural Gas Engines
Affected engines are certified or have an initial performance test per 40 CFR 60.4244.
[R307-510-4(2)]
In Compliance. Stack test on file
Affected engine exhaust vents are vertical and unrestricted.
Stacks are 8' or greater if the site horsepower rating is 151 to 305
Stacks are 10' or greater if the site horse power rating is 306 or greater. [R307-510-4(3)]
In Compliance.
3
Visible Emissions
Visible emissions, except for unavoidable irregularities that do not exceed three minutes, are within the
following opacity limits:
Installations constructed on or before 4/25/1971 40%
Installations constructed after 4/25/1971 20%
Gasoline engines 0%
Diesel engines manufactured after 1/1/1973 20%
Diesel engines manufactured before 1/1/1973 40%
Note: Required VOC control devices shall have no visible emissions per R307-508-3. [R307-201-3]
In Compliance. No visible emissions were detected.
Emission Inventory:
An emissions inventory has been submitted within the past three years. [R307-150-9(1)]
In Compliance. The Operator submitted for the 2020 emissions inventory.
NSPS (Part 60) JJJJ: Standards of Performance for Stationary Spark Ignition Internal Combustion
Engines. [40 CFR 60 Subpart JJJJ]
In Compliance.
PREVIOUS ENFORCEMENT
ACTIONS: No enforcement actions within the past five years.
COMPLIANCE STATUS &
RECOMMENDATIONS: In Compliance – The source was inspected by AVO, and with
an OGI camera, was found to be well-kept with no visible or
fugitive emissions.
RECOMMENDATION FOR
NEXT INSPECTION: The DAQ has no Recommendations for the next inspector other
than what are customary. The DAQ recommends the inspection
frequency of this source be reduced.