HomeMy WebLinkAboutDDW-2024-008132Annual Drinking Water Quality ReportThe Water We DrinkThatcher-Penrose Service 2023We are pleased to present to you this year's Annual Drinking Water Quality Report. This report is designed
to inform you about the quality of the water and services we deliver to you every day. Our constant goal is to provide you with a safe and dependable supply of drinking water. We want
you to understand the efforts we make to continually improve the water treatment process and protect our water resources. We are committed to ensuring the quality of your water. Our
water source(s) have been determined to be from Groundwater sources. Our water source is 2 wells and the Bear River Water Conversancy District.The Drinking Water Source Protection Plan
for Thatcher-Penrose is available for your review. It contains information about source protection zones, potential contamination sources and management strategies to protect our drinking
water. Our sources have been determined to have a low level of susceptibility from potential contamination from sources such asseptic tanks, roads, residential areas, industrial areas,
etc. We have also developed management strategies to further protect our sources from contamination. Please contact us if you have questions or concerns about our source protection
plan.
There are many connections to our water distribution system. When connections are properly installed and maintained, the concerns are very minimal. However, unapproved and improper
piping changes or connections can adversely affect not only the availability, but also the quality of the water. A cross connection may let polluted water or even chemicals mingle into
the water supply system when not properly protected. This not only compromises the water quality but can also affect your health. So, what can you do? Do not make or allow improper
connections at your homes. Even that unprotected garden hose lying in the puddle next to the driveway is a cross connection. The unprotected lawn sprinkler system after you have fertilized
or sprayed is also a cross connection. When the cross connection is allowed to exist at your home, it will affect you and your family first. If you’d like to learn more about helping
to protect the quality of our water, call us for further information about ways you can help.This report shows our water quality and what it means to you our customer. If you have any
questions about this report or concerning your water utility, please contact Randy Nelson at 435-466-0451. We want our valued customers to be informed about their water utility. If you
want to learn more, please attend any of our regularly scheduled meetings. They are held on second Tuesday each month opens at 6 pm.Thatcher Penrose routinely monitors for constituents
in our drinking water in accordance with the Federal and Utah State laws. The following table shows the results of our monitoring for the period of January 1st to December 31st, 2023.
All drinking water, including bottled drinking water, may be reasonably expected to contain at least small amounts of some constituents. It's important to remember that the presence
of these constituents does not necessarily pose a health risk. In the following table you will find many terms and abbreviations you might not be familiar with. To help you better understand
these terms we've provided the following definitions:Non-Detects (ND) - laboratory analysis indicates that the constituent is not present.ND/Low - High - For water systems that have
multiple sources of water, the Utah Division of Drinking Water has given water systems the option of listing the test results of the constituents in one table, instead of multiple tables.
To accomplish this, the lowest and highest values detected in the multiple sources are recorded in the same space in the report table. Parts per million (ppm) or Milligrams per liter
(mg/l) - one part per million corresponds to one minute in two years or a single penny in $10,000.Parts per billion (ppb) or Micrograms per liter (ug/l) - one part per billion corresponds
to one minute in 2,000 years, or a single penny in $10,000,000. Parts per trillion (ppt) or Nanograms per liter (nanograms/l) - one part per trillion corresponds to one minute in 2,000,000
years, or a single penny in $10,000,000,000.Parts per quadrillion (ppq) or Picograms per liter (picograms/l) - one part per quadrillion corresponds to one minute in 2,000,000,000 years
or one penny in $10,000,000,000,000.Picocuries per liter (pCi/L) - picocuries per liter is a measure of the radioactivity in water.Millirems per year (mrem/yr) - measure of radiation
absorbed by the body.Million Fibers per Liter (MFL) - million fibers per liter is a measure of the presence of asbestos fibers that are longer than 10 micrometers.Nephelometric Turbidity
Unit (NTU) - nephelometric turbidity unit is a measure of the clarity of water. Turbidity in excess of 5 NTU is just noticeable to the average person.Action Level (AL) - the concentration
of a contaminant which, if exceeded, triggers treatment or other requirements which a water system must follow.Treatment Technique (TT) - A treatment technique is a required process
intended to reduce the level of a contaminant in drinking water.Maximum Contaminant Level (MCL) - The “Maximum Allowed” (MCL) is the highest level of a contaminant that is allowed in
drinking water. MCLs are set as close to the MCLGs as feasible using the best available treatment technology.Maximum Contaminant Level Goal (MCLG) - The “Goal”(MCLG) is the level of
a contaminant in drinking water below which there is no known or expected risk to health. MCLGs allow for a margin of safety.Maximum Residual Disinfectant Level (MRDL) - The highest
level of a disinfectant allowed in drinking water. There is convincing evidence that addition of a disinfectant is necessary for control of microbial contaminants.Maximum Residual Disinfectant
Level Goal (MRDLG) - The level of a drinking water disinfectant below which there is no known or expected risk to health. MRDLGs do not reflect the benefits of the use of disinfectants
to control microbial contaminants. Date- Because of required sampling time frames i.e. yearly, 3 years, 4 years and 6 years, sampling dates may seem out-dated.Waivers (W)- Because some
chemicals are not used or stored in areas around drinking water sources, some water systems have been given waivers that exempt them from having to take certain chemical samples, these
waivers are also tied to Drinking Water Source Protection Plans.
TEST RESULTS
Contaminant
Violation
Y/N
Level
Detected
ND/Low-High
Unit
Measurement
MCLG
MCL
Date Sampled
Likely Source of Contamination
Microbiological Contaminants
Total Coliform Bacteria
N
ND
N/A
0
Presence of coliform bacteria in 5% of monthly samples
2023
Naturally present in the environment
Fecal coliform and E.coli
N
ND
N/A
0
If a routine sample and repeat sample are total coliform positive, and one is also fecal coliform or E. coli positive
2023
Human and animal fecal waste
Turbidity
for Ground Water
N
0.45
NTU
N/A
5
2023
Soil runoff
Inorganic Contaminants
Arsenic
N
1-3
ppb
0
10
2022
Erosion of natural deposits; runoff from orchards; runoff from glass and electronics production wastes
Barium
N
48-69
ppb
0
2000
2022
Discharge of drilling wastes; discharge from metal refineries; erosion of natural deposits
Copper90% results# of sites that exceed the AL
N
a.46
b.0
ppb
0
AL=1300
2021
Corrosion of household plumbing systems; erosion of natural deposits
Lead90% results# of sites that exceed the AL
N
a. 3
b.0
ppb
0
AL=15
2021
Corrosion of household plumbing systems, erosion of natural depositsNitrate (as Nitrogen)
N
1-2
ppm
0
10
2023
Runoff from fertilizer use; leaching from septic tanks, sewage; erosion of natural deposits
Selenium
N
1-4
ppb
0
50
2022
Discharge from petroleum and metal refineries; erosion of natural deposits; discharge from mines
Sodium
N
112-347
ppm
None set by EPA
None set by EPA
2022
Erosion of natural deposits; discharge from refineries and factories; runoff from landfills.
Sulfate
N
26-92
ppm
0
1000
2022
Erosion of natural deposits; discharge from refineries and factories; runoff from landfills, runoff from cropland
Fluoride
N
200
Ppb
0
4000
2021
Erosion of natural deposits
Total Dissolved Solids
N
716-1304
Ppm
0
2000
2023
Erosion of natural deposits
Disinfection By-products
TTHM [Total trihalomethanes]
N
1
ppb
0
80
2019
By-product of drinking water disinfection
Haloacetic Acids
N
ND
ppb
0
60
2019
By-product of drinking water disinfection
Radioactive Contaminants
Alpha emitters
N
2-7
pCi/1
0
15
2022
Erosion of natural deposits
Radium 228
N
ND-1
pCi/1
0
5
2022
Erosion of natural deposits
Radium 226
N
0.34
pCi/1
0
5
2022
Erosion of natural deposits
Combined 226/228
N
1
pCi/1
0
5
2022
Erosion of natural depositsIf present, elevated levels of lead can cause serious health problems, especially for pregnant women and young children. Lead in drinking water is primarily
from materials and components associated with service lines and home plumbing. Thatcher Penrose is responsible for providing high quality drinking water, but cannot control the variety
of materials used in plumbing components. When your water has been sitting for several hours, you can minimize the potential for lead exposure by flushing your tap for 30 seconds to
2 minutes before using water for drinking or cooking. If you are concerned about lead in your water, you may wish to have your water tested. Information on lead in drinking water, testing
methods, and steps you can take to minimize exposure is available from the safe Drinking Water Hotline or at http://www.epa.gov/safewater/lead.All sources of drinking water are subject
to potential contamination by constituents that are naturally occurring or manmade. Those constituents can be microbes, organic or inorganic chemicals, or radioactive materials. All
drinking water, including bottled water, may reasonably be expected to contain at least small amounts of some contaminants. The presence of contaminants does not necessarily indicate
that the water poses a health risk. More information about contaminants and potential health effects can be obtained by calling the Environmental Protection Agency’s Safe Drinking Water
Hotline at 1-800-426-4791.MCLs are set at very stringent levels. To understand the possible health effects described for many regulated constituents, a person would have to drink 2 liters
of water every day at the MCL level for a lifetime to have a one-in-a-million chance of having the described health effect.Some people may be more vulnerable to contaminants in drinking
water than the general population. Immuno-compromised persons such as persons with cancer undergoing chemotherapy, persons who have undergone organ transplants, people with HIV/AIDS
or other immune system disorders, some elderly, and infants can be particularly at risk from infections. These people should seek advice from their health care providers about drinking
water. EPA/CDC guidelines on appropriate means to lessen the risk of infection by cryptosporidium and other microbiological contaminants are available from the Safe Drinking Water Hotline
(800-426-4791). We at Thatcher Penrose work around the clock to provide top quality water to every tap. We ask that all our customers help us protect our water sources, which are the
heart of our community, our way of life and our children’s future.
Brandi Smith
CCR Compliance
Division of Drinking Water
P.O. Box 144830
Salt Lake City, Utah 84114-4830
Dear Ms. Smith:
Subject: Consumer Confidence Report for Thatcher Penrose Utah02025
Enclosed is a copy of Thatcher PenroseConsumer Confidence Report. It contains the water quality information for our water system for the calendar year 2023or the most recent sample
data.
We have delivered this report to our customers by:
Putting a notice of the availability of the report on our water bills, then mailing a report to those who request it.
Making copies of the report available at the water office.
------------------------------------------------------------------------------------------
Publishing the entire report on the internet:
It is located at the URL –Thatcherwater@blogspot.com
Sincerely,
Randy Nelson