HomeMy WebLinkAboutDAQ-2024-008328
195 North 1950 West • Salt Lake City, UT
Mailing Address: P.O. Box 144820 • Salt Lake City, UT 84114-4820
Telephone (801) 536-4000 • Fax (801) 536-4099 • T.D.D. (801) 903-3978
www.deq.utah.gov
Printed on 100% recycled paper
State of Utah
Department of
Environmental Quality
Kimberly D. Shelley
Executive Director
DIVISION OF AIR QUALITY
Bryce C. Bird
Director
SPENCER J. COX
Governor
DEIDRE HENDERSON
Lieutenant Governor
DAQC-531-24
Site ID 11042 (B1)
Grant Ensign
Geneva Rock Products, Inc.
730 North 1500 West
Orem, UT 84057
Dear Mr. Ensign:
Re: Geneva Rock Products, Inc. – Temporary Relocation/Operation, Notice of Intent –
Salt Lake County
Your Notice of Intent dated May 21, 2024, to relocate portable concrete batch plant equipment to
the temporary project located from the I-215 2100 north Exit, to south on 2200 West for 0.6 miles,
Salt Lake City, UT, was received by the Utah Division of Air Quality (DAQ) and has been
reviewed.
The following equipment has been approved for operation for this temporary project:
Erie Strayer MC-11C mobile concrete batch plant
5.2 MMbtu/hr diesel water heater
737 bhp diesel generator
66 bhp diesel generator
The State of Utah has permitted portable equipment for Geneva Rock Products on the Approval
Order DAQE-AN110420003-21, dated March 17, 2021. Approval is granted to relocate and
operate this equipment at the new location for a period not to exceed 180 operational days. As per
Utah Administrative Code (UAC) R307-401-17, the operation of equipment at this temporary site
may be for up to 180 working days in any calendar year not to exceed 365 consecutive days,
starting from the initial relocation date. Approval is subject to the conditions of the dust control
plan submitted for this location and the applicable conditions of the above referenced portable
AO. Due to the UDOT scheduling requirements for this project, hours of operation can be up to
24-hours each day. The maximum production rate shall be held to the requested 300 cubic yards
per hour. The DAQ does not currently estimate emissions from temporary concrete batch projects.
2 + " à Û Ù Û Ý
DAQC-531-24
Page 2
The owner/operator shall maintain records of the actual operation hours, days, and production
rate, of the above referenced equipment at this relocation site and have the ability to submit the
information to the DAQ upon the request of representatives of the Director. Please make certain
that the plant operator is aware of all the location specific requirements for this site and the
conditions of the aforementioned AO.
Utah Division of Water Quality Storm Water Permits and regulations may apply to this temporary
project. Please refer to https://secure.utah.gov/deq-dashboard/index.html for additional
information.
This approval for relocation in no way releases the owner or operator from any liability for
compliance with all other applicable federal, state, and local regulations including the UAC.
If you have any questions regarding this relocation authorization or the temporary relocation
process, please contact Susan Weisenberg at (385) 306-6512.
Sincerely,
Jay P. Morris
Assistant Director
JPM:SPW:jl
Enclosure: Submitted Temporary Relocation Form
cc: Salt Lake County Health Department
4 * - - $ . — 0 ) E v A ? A C @ D w ? A ˜
Susan Weisenberg <sweisenberg@utah.gov>
Portable/Temporary Relocation Form
1 message
noreply@qemailserver.com <noreply@qemailserver.com>Tue, May 21, 2024 at 12:00 PM
Reply-To: trigger@qemailserver.com
To: sweisenberg@utah.gov
Susan/Chad:
Site # -- Geneva Rock Products has requested a Temporary Relocation. Please see the information below. Any
attachments can be access by clicking on the links.
Recipient Data:
Time Finished: 2024-05-21 12:00:43 MDT
IP: 64.77.251.44
ResponseID: R_5n0IEFrPS5AfOlg
Link to View Results: Click Here
URL to View Results: https://utahgov.iad1.qualtrics.com/apps/single-response-reports/reports/
e98fJTmNuuo51SXYfBQBCSJe0-lyJ28vTwXRvILmXXOw3CbSz0KVkgK2PjjhjI8Uu2px66gRyWATPji5J57jFC
TuHoEu7ZPjTy5m16RVmHBBzninlVafMv6IrpJ86H1Dd2AgHEQe-VwNmPnyOWNtJR5T%2Ea1GxxMd-
viOOqINVOiXrJa9EkhVqASgwo8KlCo7BHRAjC5DWYNs0%2EEc72Uv%2E4qh7NnVLQu0uqXnF676GybO75p5XpLx7-
zQzu31SjkVQ72sE9a6pSmDw%2Ewj8czgUO-Z3xrpNtRk40mqh1dnEfADGFpCtS27ujpZZV7xjKNWfV-
54F0X0vmsQQtAUKmmug
Response Summary:
Please fill out the information below:
Contact Person: Grant Ensign
Company Name: Geneva Rock Products
Mailing Address: 730 N 1500 West
City: Orem
Zip: 84057
Phone Number: 8018026954
Email: gensign@clydeinc.com
Is the site located within a PM2.5 non-attainment and maintenance plan areas on cleared land grea...
Yes
All temporary relocation projects are required to submit a Fugitive Dust Control Plan (FDCP). Lo...
4C5AF3A229
Briefly give directions to the site and/or physical address:
Exit 2100 N from I-215, then head west to 2200 W. Turn south on 2200 West and proceed for approximately 0.6 miles.
The site is located on the west side of the street.
Proposed Relocation Information:
Closest City Salt Lake City
County Salt Lake
UTM X Coordinates 40.804300
UTM Y Coordinates -111.955363
Approximate distance to the nearest house/business 450 feet
UTM X Coordinates to nearest house/business 40.804552
UTM Y Coordinates to nearest house/business -111.952049
5/28/24, 6:40 PM State of Utah Mail - Portable/Temporary Relocation Form
https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1799686142759618176%7Cmsg-f:1799686142759618176&…1/2
Does this site currently have a permit with DAQ?
No
Please provide the permit ID for the equipment? (DAQE-XXXXXXXXX-XX)
DAQE-AN110420003-21
Please list all the Equipment on Site:Note: It is important to identify ALL diesel powered engine...
1
Equipment Type Mobile Concrete Batch Plant
Make/Model Erie Strayer MC-11C
Manufactured Date 2019
Design Capacity 300 CY/hr
2
Equipment Type Diesel Generator
Manufactured Date 1989
Design Capacity 737 bhp
3
Equipment Type Support Equip (silos, feeders, conveyors, baghouse, etc)
4
Equipment Type Diesel Water Heater
Make/Model Power Flame/Rock Mills
Manufactured Date 1984
Design Capacity 5.2 MMbtu/hr
5
Equipment Type Diesel Generator
Design Capacity 66 bhp
Have any other state or local regulatory agencies issued any other "Conditional Use Permits" for...
No
Operational Information: (Please note: Operating time over 16 hours in a 24 hour period will re...
Total Hours of operation per 24 hr period 24
Starting time of operation (am/pm) 12 AM
Ending time of operation (am/pm) 12 AM
Maximum hourly production rate for project 300 CY/hr
Expected startup date 06/01/2024
Expected completion date 06/01/2025
What type of application is this for?
New Application
In accordance with the fee schedule approved by the Utah State Legislature, the Division of Air Q...
https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_1DHzb7385u1k2to
Owner/Operator Representative:
https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_XsRDGm0se7RtvwZ
5/28/24, 6:40 PM State of Utah Mail - Portable/Temporary Relocation Form
https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1799686142759618176%7Cmsg-f:1799686142759618176&…2/2
Susan Weisenberg <sweisenberg@utah.gov>
Re: reference to 24-hour operation batch plant TRP in SLC
1 message
Grant Ensign <gensign@clydeinc.com>Tue, May 28, 2024 at 6:43 PM
To: Susan Weisenberg <sweisenberg@utah.gov>
Yes, that is correct. Thanks.
—————
Grant Ensign
Clyde Companies
ENVIRONMENTAL SPECIALIST
O (801) 802-6954
C (801) 633-7830
WWW.CLYDEINC.COM
From: Susan Weisenberg <sweisenberg@utah.gov>
Sent: Tuesday, May 28, 2024 5:41:35 PM
To: Grant Ensign <gensign@clydeinc.com>
Subject: re: reference to 24-hour opera on batch plant TRP in SLC
Hello Grant, the relocation submission for the batch plant located 2200 W in Salt Lake City references a 24-hour
operation. Is this 24-hour request due to UDOT project requirements? Thanks
Susan Weisenberg,
Environmental Scientist
Office: 385-306-6512
6/3/24, 10:26 AM State of Utah Mail - Re: reference to 24-hour operation batch plant TRP in SLC
https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-a:r1506925965730012650%7Cmsg-f:1800345671317138253…1/1