Loading...
HomeMy WebLinkAboutDAQ-2024-008323 195 North 1950 West • Salt Lake City, UT Mailing Address: P.O. Box 144820 • Salt Lake City, UT 84114-4820 Telephone (801) 536-4000 • Fax (801) 536-4099 • T.D.D. (801) 903-3978 www.deq.utah.gov Printed on 100% recycled paper State of Utah Department of Environmental Quality Kimberly D. Shelley Executive Director DIVISION OF AIR QUALITY Bryce C. Bird Director SPENCER J. COX Governor DEIDRE HENDERSON Lieutenant Governor DAQC-484-24 Site ID 14068 (B1) Kyle Blackburn Northshore Rock Products & Excavation 1740 Combe Road South Ogden, UT 84403 Dear Mr. Blackburn: Re: Northshore Rock Products & Excavation – Temporary Relocation/Operation, Notice of Intent – Weber County Your Notice of Intent dated May 7, 2024, to relocate portable aggregate equipment to the temporary housing development project located at 3090 North Mountain Road, North Ogden, UT, was received by the Utah Division of Air Quality (DAQ) and has been reviewed. The following equipment has been approved for operation for this temporary project: KPI JCI self-powered track jaw crusher with 230 hp engine JCI Pull & Go screen with 95 hp engine 966 Cat loader Approval is granted to relocate and operate this equipment at the new location for a period not to exceed 180 operational days. As discussed during the telephone conversation on May 20, 2024, the current phase of this project cannot exceed 180 working days in any calendar year not to exceed 365 consecutive days, starting from the initial relocation date. Approval is subject to the conditions of the dust control plan submitted for this location and the current Goodfellow Corporation portable Approval Order (AO) DAQE-AN140680003-18 dated April 18, 2018. Hours of operation shall be held to 10 hours each day. The maximum production rate shall be held to the requested 400 tons per hour. Emissions for this project have been estimated at the following: Pollutant gram/sec lbs/hr lbs/24 hr tons/yr PPM10 1.64 13.00 129.97 10.14 SOx 0.63 4.99 49.88 3.89 NOx 4.20 33.33 333.34 26.00 CO 1.11 8.84 88.40 6.90 VOC 0.18 1.39 13.91 1.08 2 + " à Û Ù Û Ý DAQC-484-24 Page 2 The owner/operator shall maintain records of the actual operation hours, days, and production rate, of the above referenced equipment at this relocation site and have the ability to submit the information to the DAQ upon the request of representatives of the Director. Please make certain that the plant operator is aware of all the location specific requirements for this site and the conditions of the aforementioned AO. NSPS Subpart OOO requires that initial Method 9 observations be performed for all applicable portable crushers, screens, and attached conveyors. Subpart OOO also mandates that all crushers constructed, modified, or reconstructed on or after April 22, 2008, which are not enclosed, must install spray bars on the equipment and keep maintenance records to ensure proper spray bar operations. Utah Division of Water Quality Storm Water Permits and regulations may apply to this temporary project. Please refer to Utah DEQ Water Quality’s current Storm Water Construction requirements for additional information. This approval for relocation in no way releases the owner or operator from any liability for compliance with all other applicable federal, state, and local regulations including the UAC. If you have any questions regarding this relocation authorization or the temporary relocation process p lease contact Susan Weisenberg at (385) 306-6512. Sincerely, Jay P. Morris Assistant Director JPM:SPW:jl Enclosure: Submitted Temporary Relocation Form cc: Weber-Morgan Health Department 4 * - - $ . — 0 ) E v A ? A C @ D w ? @ ˜ Susan Weisenberg <sweisenberg@utah.gov> Portable/Temporary Relocation Form 1 message noreply@qemailserver.com <noreply@qemailserver.com>Tue, May 7, 2024 at 4:54 PM Reply-To: trigger@qemailserver.com To: sweisenberg@utah.gov Susan/Chad: Site # -- NORTHSHORE ROCK PRODUCTS & EXCAVATION has requested a Temporary Relocation. Please see the information below. Any attachments can be access by clicking on the links. Recipient Data: Time Finished: 2024-05-07 16:54:14 MDT IP: 67.182.210.252 ResponseID: R_7COZ6klTfJPmsJ3 Link to View Results: Click Here URL to View Results: https://utahgov.iad1.qualtrics.com/apps/single-response-reports/reports/ lySM8FRAAGSv0v2VxZ7x93PFdb8VedefHYXlGKajGv45ByJoTOdmRvie-S008n4bUkmTAuBmxyjIKdJDYBwUuiU sBqGi9ruzmayN6wt8RtS-B49eWsBd945PCHBqtx92o3PT8GcTK6BPlglhpppRnbtb2zqQx-CrG-% 2E99NiawTDjLaCYdIfqo4OqOWhh5g6eFyjAd4A7z0M3BSntW9q23nup4emI432kdXPLASSXzQ3ggFQl-OFdd2A5% 2Etda4KgRp5VIrF%2E%2EyJRvL6M6UHCaEuCPzvnpdR9Um38zOfgRitrtzEhdGVQpkWbQXG6JS5SnzK QQjZ9QD%2EdWMIzQqmxW2Q Response Summary: Please fill out the information below: Contact Person: KYLE BLACKBURN Company Name: NORTHSHORE ROCK PRODUCTS & EXCAVATION Mailing Address: 1740 COMBE RD City: SOUTH OGDEN Zip: 84403 Phone Number: 8018146145 Email: kyle@northshorerockproducts.com Is the site located within a PM2.5 non-attainment and maintenance plan areas on cleared land grea... Yes All temporary relocation projects are required to submit a Fugitive Dust Control Plan (FDCP). Lo... AE6BBB3D1C Briefly give directions to the site and/or physical address: 3090 North Mountain Road, North Ogden, UT 84414 Head east toward north ogden divide on 3100 N. Turn right on mountain road. Take first left on to Mountain Road. Head to the end of the road into new development. Proposed Relocation Information: Closest City North Ogden County Weber UTM X Coordinates 41.316517 UTM Y Coordinates -111.935191 Approximate distance to the nearest house/business 152 UTM X Coordinates to nearest house/business 41.315031 UTM Y Coordinates to nearest house/business -111.936075 5/20/24, 12:37 PM State of Utah Mail - Portable/Temporary Relocation Form https://mail.google.com/mail/u/1/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1798422591184688648%7Cmsg-f:1798436250040902318&…1/2 Does this site currently have a permit with DAQ? No Please provide the permit ID for the equipment? (DAQE-XXXXXXXXX-XX) Good Fellow Crushing Please list all the Equipment on Site:Note: It is important to identify ALL diesel powered engine... 1 Equipment Type Jaw Crusher Make/Model KPI JCI Manufactured Date 2005 2 Equipment Type Pull & Go (Screen) Make/Model JCI Manufactured Date 2009 3 Equipment Type 966 Loader Make/Model CAT Manufactured Date 2001 Please attach a site diagram showing the equipment layout and general site dimensions for this re... https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_2qsyt3BqR1Mo3Tu Have any other state or local regulatory agencies issued any other "Conditional Use Permits" for... Yes If Yes, please list all other local and state agencies that have issued any other permits North Ogden City Operational Information: (Please note: Operating time over 16 hours in a 24 hour period will re... Total Hours of operation per 24 hr period 6 Starting time of operation (am/pm) 8 Ending time of operation (am/pm) 3 Maximum hourly production rate for project 400 Ton/hr Expected startup date 05/20/2024 Expected completion date 05/20/2026 What type of application is this for? Modification to an existing Temporary Relocation Owner/Operator Representative: https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_1N9c9u8ZB6YNGTC 5/20/24, 12:37 PM State of Utah Mail - Portable/Temporary Relocation Form https://mail.google.com/mail/u/1/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1798422591184688648%7Cmsg-f:1798436250040902318&…2/2 Susan Weisenberg <sweisenberg@utah.gov> White rock air quality 1 message Kyle Blackburn <kyle@northshorerockproducts.com>Mon, May 20, 2024 at 12:02 PM To: Susan Weisenberg <sweisenberg@utah.gov> Hello Susan, Per our conversation we’re ok with a 10hr operating day and the actual distance from the nearest home is 538ft. I believe we entered feet on the application but many yards so that’s why there was a discrepancy. Thank you. Regards, Kyle Blackburn Northshore Rock Products & Excavation Sent from my iPhone 5/20/24, 12:29 PM State of Utah Mail - White rock air quality https://mail.google.com/mail/u/1/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1799595631551516307%7Cmsg-f:1799595631551516307&…1/1 Susan Weisenberg <sweisenberg@utah.gov> Re: generator information 1 message Kyle Blackburn <kyle@northshorerockproducts.com>Wed, May 29, 2024 at 6:59 PM To: Susan Weisenberg <sweisenberg@utah.gov> One is 95 horse and the other is 230 horse power diesel engines. No generators or electrical power. Thank you! Kyle Sent from my iPhone On May 22, 2024, at 11:39 AM, Susan Weisenberg <sweisenberg@utah.gov> wrote: Hello, can you let me know if the equipment involved at the North Ogden location will be powered by diesel- fired generators or if they will be powered by an electrical grid? If diesel-fired generators are involved, please give me the power ratings. Thanks, the DAQ management has recently required generator information for all temporary relocation projects. Susan Weisenberg, Environmental Scientist Office: 385-306-6512 5/30/24, 10:35 AM State of Utah Mail - Re: generator information https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-a:r2708352394157113076%7Cmsg-f:1800437230686524790…1/1