Loading...
HomeMy WebLinkAboutDAQ-2024-0083101 DAQC-540-24 Site ID 13079 (B4) MEMORANDUM TO: STACK TEST FILE – MOUNTAINWEST PIPELINE, LLC – Blind Canyon Compressor Station THROUGH: Rik Ombach, Minor Source Oil and Gas Compliance Section Manager FROM: Paul Bushman, Environmental Scientist DATE: June 3, 2024 SUBJECT: Source: Turbine T-1 and Turbine T-2 Location: Remote Location on West Tavaputs Plateau, Myton, Utah Contact: Dani Baldwin: 801-201-0595 Tester: Oasis Emission Consultants, Inc. Site ID #: 13079 Permit/AO #: DAQE-AN130790006-12, dated April 2, 2012 Subject: Review of Pretest Protocol dated May 30, 2024 On May 31, 2024, Utah Division of Air Quality (DAQ) received a test notification for the testing of Turbine T-1 and Turbine T-2 at Blind Canyon Compressor Station in Duchesne County, Utah. Testing will be performed July 17, 2024, through July 18, 2024, to determine compliance with the emission limits found in condition II.B.2 of DAQE-AN130790006-12 and 40 CFR Part 60, Subpart KKKK. PROTOCOL CONDITIONS: 1. RM 1 used to determine sample velocity traverses: OK 2. RM 2 used to determine gas velocity and volumetric flow rate: OK 3. RM 3A used to determine O2 and CO2 concentrations: OK 4. RM 4 used to determine moisture content: OK 5. RM 7E used to determine NOx emissions: OK 6. RM 10 used to determine CO emissions: OK 7. RM 19 used to determine exhaust effluent flows and mass emission rates: OK DEVIATIONS: No deviations stated in the protocol. CONCLUSION: The protocol appears to be acceptable. RECOMMENDATION: Send protocol review and test date confirmation notice. ATTACHMENTS: MountainWest Pipeline, LLC test notification and pretest protocol. 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30