HomeMy WebLinkAboutDAQ-2024-008277
195 North 1950 West • Salt Lake City, UT
Mailing Address: P.O. Box 144820 • Salt Lake City, UT 84114-4820
Telephone (801) 536-4000 • Fax (801) 536-4099 • T.D.D. (801) 903-3978
www.deq.utah.gov
Printed on 100% recycled paper
State of Utah
Department of
Environmental Quality
Kimberly D. Shelley
Executive Director
DIVISION OF AIR QUALITY
Bryce C. Bird
Director
SPENCER J. COX
Governor
DEIDRE HENDERSON
Lieutenant Governor
DAQC-474-23
Site 12931 (B1)
Lee Ware
Kilgore Companies, LLC
P.O. Box 869
Magna, Utah 84044
Dear Mr. Ware:
Re: Kilgore Companies, LLC – Temporary Relocation/Operation, Notice of Intent – San Juan
County
Your Notice of Intent dated May 2, 2023, to relocate portable aggregate equipment to the
temporary project located off of Mile Marker 27.2, Utah Highway 191, Bluff, Utah, was received
by the Utah Division of Air Quality (DAQ) and has been reviewed.
The following equipment has been approved for operation for this temporary project:
Lippmann – Cedarapids 2450 jaw crusher
Cedarapids MV550X cone crusher
Cedarapids T6203 tandem 6x20 triple deck screen
Cedarapids 6203 6x20 triple deck screen
Caterpillar 725 kW diesel generator
MultiQuip/Isuzu QD100 75 kW diesel generator
SW-AST diesel fuel tank
Approval is granted to relocate and operate this equipment at the new location for a period not to
exceed 180 operational days. As per Utah Administrative Code (UAC) R307-401-17, the
operation of equipment at this temporary site may be for up to 180 working days in any calendar
year not to exceed 365 consecutive days, starting from the initial relocation date. The operational
days per site cannot be extended beyond the stipulated 365 consecutive day period. Approval is
subject to the conditions of the dust control plan submitted for this location and the current
Approval Order (AO) DAQE-AN129310019-18 dated April 12, 2018. Hours of operation shall be
held to 15 hours each day. The maximum production rate shall be held to the requested 500 tons
per hour.
6 Ú Þ Û Ù Û Ü
DAQC-474-23
Page 2
Pollutant gram/sec lbs./hr. lbs./24 hr. tons/yr.
PM10 1.97 15.67 156.71 12.22
SOx 0.78 6.16 61.56 4.80
NOx 5.15 40.91 409.11 31.91
CO 1.36 10.75 107.54 8.39
VOC 0.21 1.68 16.83 1.31
The owner/operator shall maintain records of the actual operation hours, days, and production
rate, of the above referenced equipment at this relocation site and have the ability to submit the
information to the DAQ upon the request of representatives of the Director. Please make certain
that the plant operator is aware of all the location specific requirements for this site and the
conditions of the aforementioned AO.
Federal New Source Performance Standards Subpart OOO requires that initial Method 9
observations be performed for all applicable portable crushers, screens and attached conveyors.
Subpart OOO also mandates that all crushers constructed, modified, or reconstructed on or after
April 22, 2008, which are not enclosed, must install spray bars on the equipment and keep
maintenance records to ensure proper spray bar operations.
Utah Division of Water Quality Storm Water Permits and regulations may apply to this temporary
project. Please refer to Utah DEQ Water Quality’s current Storm Water Construction
requirements for additional information.
This approval for relocation in no way releases the owner or operator from any liability for
compliance with all other applicable federal, state, and local regulations including the UAC.
If you have any questions regarding this relocation authorization or the temporary relocation
process please contact Susan Weisenberg at (385) 306-6512.
Sincerely,
Jay P. Morris
Assistant Director
JPM:SPW:km
Enclosure: Submitted Temporary Relocation Form
cc: Southeast Utah Health Department
4 * - - $ . — 4 @ @ v A ? A B @ F w D G ˜
5/3/23, 8:29 AM State of Utah Mail - Portable/Temporary Relocation Form
https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1764806067150268394%7Cmsg-f:1764806067150268394&…1/3
Susan Weisenberg <sweisenberg@utah.gov>
Portable/Temporary Relocation Form
1 message
noreply@qemailserver.com <noreply@qemailserver.com>Tue, May 2, 2023 at 11:56 AM
Reply-To: trigger@qemailserver.com
To: sweisenberg@utah.gov
Susan/Chad:
Site # -- Kilgore Companies has requested a Temporary Relocation. Please see the information below. Any attachments
can be access by clicking on the links.
Recipient Data:
Time Finished: 2023-05-02 11:56:46 MDT
IP: 165.225.10.246
ResponseID: R_9pNCNESrsxt7hpT
Link to View Results: Click Here
URL to View Results: https://utahgov.iad1.qualtrics.com/apps/single-response-reports/reports/
WEGKVUhOzVJupXPyDUfm1tCXUSDMv22-dBey5zWV8oyvYV1tcqOMI0Bycq2XCK
pu9wPzC9IVIDGAnqKn0pJtfNg6E3h5LLaEXIEsyNyDfarrF-vdip73h4esi-IOdyjrS7enRsgi9uhyitAtm2MTdxsE
0GrbyBTS8PN%2EmkWIWSPplx249j3IX8zQk4yHXr6AK8NdXHcJeLp3bDFIa3zrhMF19aX9X4
E5f43qnqxoFyuGmJFoBdkIyc7sucT4kccPy-rC7%2ERR5vEdjNyajD63la9jxoapqt5%2EOkBF-8-
t6mkzVwLBae6XnFwtKB8ZHvoW
Response Summary:
Please fill out the information below:
Contact Person: Lee Ware
Company Name: Kilgore Companies
Mailing Address: P.O. Box 869
City: Magna
Zip: 84044
Phone Number: 801-250-0132
Email: lee.ware@kilgorecompanies.com
Is the site located within a PM2.5 non-attainment and maintenance plan areas on cleared land grea...
No
All temporary relocation projects are required to submit a Fugitive Dust Control Plan (FDCP). Lo...
f107052a-1c68-4258-9082-6c58bfd9d13a
Briefly give directions to the site and/or physical address:
Pit Entrance, Turn West at Mile Marker 27.2 UT HWY 191, Bluff, UT
Proposed Relocation Information:
Closest City Bluff
County San Juan County
UTM X Coordinates 628607.05 mE
UTM Y Coordinates 4128924.04 mN
Approximate distance to the nearest house/business 2,263 feet
UTM X Coordinates to nearest house/business 628641.37 mE
UTM Y Coordinates to nearest house/business 4129594.85 mN
Does this site currently have a permit with DAQ?
5/3/23, 8:29 AM State of Utah Mail - Portable/Temporary Relocation Form
https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1764806067150268394%7Cmsg-f:1764806067150268394&…2/3
No
Please provide the permit ID for the equipment? (DAQE-XXXXXXXXX-XX)
DAQE-AN0129310019-18
Please list all the Equipment on Site:Note: It is important to identify ALL diesel powered engine...
1
Equipment Type Jaw Crusher
Make/Model Lippmann - Cedarapids 2450
Serial or ID# 2016-0460, 2016-0459
Manufactured Date 2016
Design Capacity 500 tph
2
Equipment Type Cone Crusher
Make/Model Cedarapids MV550X
Serial or ID# TRXRX550KOKGF0870
Manufactured Date 2016
Design Capacity 500 tph
3
Equipment Type Tandem 6x20 Triple Deck Screen
Make/Model Cedarapids T6203
Serial or ID# TRXV6203KDUGD2249, TRXV6203TDUGD2250
Manufactured Date 2016
Design Capacity 500 tph
4
Equipment Type 6x20 Triple Deck Screen
Make/Model Cedarapids 6203
Serial or ID# P62031406
Manufactured Date 2007
Design Capacity 500 tph
5
Equipment Type Diesel Generator
Make/Model Caterpillar C27P
Serial or ID# TAZ000307
Manufactured Date 2013
Design Capacity 725 kW
6
Equipment Type Diesel Generartor
Make/Model MultiQuip/Isuzu QD100
Serial or ID# 7510986
Manufactured Date 2013
Design Capacity 75 kW
7
Equipment Type AST Doeuble Walled AST Fuel Tank
Make/Model SW-AST
Serial or ID# 98.085
Manufactured Date na
Design Capacity 10,000 gal
Please attach a site diagram showing the equipment layout and general site dimensions for this re...
https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_3n6PcSFe24UbQgt
Have any other state or local regulatory agencies issued any other "Conditional Use Permits" for...
No
Operational Information: (Please note: Operating time over 16 hours in a 24 hour period will re...
Total Hours of operation per 24 hr period 15
Starting time of operation (am/pm) 5:00 AM
Ending time of operation (am/pm) 10:00 PM
Maximum hourly production rate for project 500 tph
Expected startup date 05/08/2023
Expected completion date 11/30/2023
What type of application is this for?
New Application
5/3/23, 8:29 AM State of Utah Mail - Portable/Temporary Relocation Form
https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1764806067150268394%7Cmsg-f:1764806067150268394&…3/3
In accordance with the fee schedule approved by the Utah State Legislature, the Division of Air Q...
https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_W3EY4ul7oMhK29H
Owner/Operator Representative:
https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_2wGKMe9PI0jFUrj