Loading...
HomeMy WebLinkAboutDAQ-2024-008277 195 North 1950 West • Salt Lake City, UT Mailing Address: P.O. Box 144820 • Salt Lake City, UT 84114-4820 Telephone (801) 536-4000 • Fax (801) 536-4099 • T.D.D. (801) 903-3978 www.deq.utah.gov Printed on 100% recycled paper State of Utah Department of Environmental Quality Kimberly D. Shelley Executive Director DIVISION OF AIR QUALITY Bryce C. Bird Director SPENCER J. COX Governor DEIDRE HENDERSON Lieutenant Governor DAQC-474-23 Site 12931 (B1) Lee Ware Kilgore Companies, LLC P.O. Box 869 Magna, Utah 84044 Dear Mr. Ware: Re: Kilgore Companies, LLC – Temporary Relocation/Operation, Notice of Intent – San Juan County Your Notice of Intent dated May 2, 2023, to relocate portable aggregate equipment to the temporary project located off of Mile Marker 27.2, Utah Highway 191, Bluff, Utah, was received by the Utah Division of Air Quality (DAQ) and has been reviewed. The following equipment has been approved for operation for this temporary project: Lippmann – Cedarapids 2450 jaw crusher Cedarapids MV550X cone crusher Cedarapids T6203 tandem 6x20 triple deck screen Cedarapids 6203 6x20 triple deck screen Caterpillar 725 kW diesel generator MultiQuip/Isuzu QD100 75 kW diesel generator SW-AST diesel fuel tank Approval is granted to relocate and operate this equipment at the new location for a period not to exceed 180 operational days. As per Utah Administrative Code (UAC) R307-401-17, the operation of equipment at this temporary site may be for up to 180 working days in any calendar year not to exceed 365 consecutive days, starting from the initial relocation date. The operational days per site cannot be extended beyond the stipulated 365 consecutive day period. Approval is subject to the conditions of the dust control plan submitted for this location and the current Approval Order (AO) DAQE-AN129310019-18 dated April 12, 2018. Hours of operation shall be held to 15 hours each day. The maximum production rate shall be held to the requested 500 tons per hour. 6 Ú Þ Û Ù Û Ü DAQC-474-23 Page 2 Pollutant gram/sec lbs./hr. lbs./24 hr. tons/yr. PM10 1.97 15.67 156.71 12.22 SOx 0.78 6.16 61.56 4.80 NOx 5.15 40.91 409.11 31.91 CO 1.36 10.75 107.54 8.39 VOC 0.21 1.68 16.83 1.31 The owner/operator shall maintain records of the actual operation hours, days, and production rate, of the above referenced equipment at this relocation site and have the ability to submit the information to the DAQ upon the request of representatives of the Director. Please make certain that the plant operator is aware of all the location specific requirements for this site and the conditions of the aforementioned AO. Federal New Source Performance Standards Subpart OOO requires that initial Method 9 observations be performed for all applicable portable crushers, screens and attached conveyors. Subpart OOO also mandates that all crushers constructed, modified, or reconstructed on or after April 22, 2008, which are not enclosed, must install spray bars on the equipment and keep maintenance records to ensure proper spray bar operations. Utah Division of Water Quality Storm Water Permits and regulations may apply to this temporary project. Please refer to Utah DEQ Water Quality’s current Storm Water Construction requirements for additional information. This approval for relocation in no way releases the owner or operator from any liability for compliance with all other applicable federal, state, and local regulations including the UAC. If you have any questions regarding this relocation authorization or the temporary relocation process please contact Susan Weisenberg at (385) 306-6512. Sincerely, Jay P. Morris Assistant Director JPM:SPW:km Enclosure: Submitted Temporary Relocation Form cc: Southeast Utah Health Department 4 * - - $ . — 4 @ @ v A ? A B @ F w D G ˜ 5/3/23, 8:29 AM State of Utah Mail - Portable/Temporary Relocation Form https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1764806067150268394%7Cmsg-f:1764806067150268394&…1/3 Susan Weisenberg <sweisenberg@utah.gov> Portable/Temporary Relocation Form 1 message noreply@qemailserver.com <noreply@qemailserver.com>Tue, May 2, 2023 at 11:56 AM Reply-To: trigger@qemailserver.com To: sweisenberg@utah.gov Susan/Chad: Site # -- Kilgore Companies has requested a Temporary Relocation. Please see the information below. Any attachments can be access by clicking on the links. Recipient Data: Time Finished: 2023-05-02 11:56:46 MDT IP: 165.225.10.246 ResponseID: R_9pNCNESrsxt7hpT Link to View Results: Click Here URL to View Results: https://utahgov.iad1.qualtrics.com/apps/single-response-reports/reports/ WEGKVUhOzVJupXPyDUfm1tCXUSDMv22-dBey5zWV8oyvYV1tcqOMI0Bycq2XCK pu9wPzC9IVIDGAnqKn0pJtfNg6E3h5LLaEXIEsyNyDfarrF-vdip73h4esi-IOdyjrS7enRsgi9uhyitAtm2MTdxsE 0GrbyBTS8PN%2EmkWIWSPplx249j3IX8zQk4yHXr6AK8NdXHcJeLp3bDFIa3zrhMF19aX9X4 E5f43qnqxoFyuGmJFoBdkIyc7sucT4kccPy-rC7%2ERR5vEdjNyajD63la9jxoapqt5%2EOkBF-8- t6mkzVwLBae6XnFwtKB8ZHvoW Response Summary: Please fill out the information below: Contact Person: Lee Ware Company Name: Kilgore Companies Mailing Address: P.O. Box 869 City: Magna Zip: 84044 Phone Number: 801-250-0132 Email: lee.ware@kilgorecompanies.com Is the site located within a PM2.5 non-attainment and maintenance plan areas on cleared land grea... No All temporary relocation projects are required to submit a Fugitive Dust Control Plan (FDCP). Lo... f107052a-1c68-4258-9082-6c58bfd9d13a Briefly give directions to the site and/or physical address: Pit Entrance, Turn West at Mile Marker 27.2 UT HWY 191, Bluff, UT Proposed Relocation Information: Closest City Bluff County San Juan County UTM X Coordinates 628607.05 mE UTM Y Coordinates 4128924.04 mN Approximate distance to the nearest house/business 2,263 feet UTM X Coordinates to nearest house/business 628641.37 mE UTM Y Coordinates to nearest house/business 4129594.85 mN Does this site currently have a permit with DAQ? 5/3/23, 8:29 AM State of Utah Mail - Portable/Temporary Relocation Form https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1764806067150268394%7Cmsg-f:1764806067150268394&…2/3 No Please provide the permit ID for the equipment? (DAQE-XXXXXXXXX-XX) DAQE-AN0129310019-18 Please list all the Equipment on Site:Note: It is important to identify ALL diesel powered engine... 1 Equipment Type Jaw Crusher Make/Model Lippmann - Cedarapids 2450 Serial or ID# 2016-0460, 2016-0459 Manufactured Date 2016 Design Capacity 500 tph 2 Equipment Type Cone Crusher Make/Model Cedarapids MV550X Serial or ID# TRXRX550KOKGF0870 Manufactured Date 2016 Design Capacity 500 tph 3 Equipment Type Tandem 6x20 Triple Deck Screen Make/Model Cedarapids T6203 Serial or ID# TRXV6203KDUGD2249, TRXV6203TDUGD2250 Manufactured Date 2016 Design Capacity 500 tph 4 Equipment Type 6x20 Triple Deck Screen Make/Model Cedarapids 6203 Serial or ID# P62031406 Manufactured Date 2007 Design Capacity 500 tph 5 Equipment Type Diesel Generator Make/Model Caterpillar C27P Serial or ID# TAZ000307 Manufactured Date 2013 Design Capacity 725 kW 6 Equipment Type Diesel Generartor Make/Model MultiQuip/Isuzu QD100 Serial or ID# 7510986 Manufactured Date 2013 Design Capacity 75 kW 7 Equipment Type AST Doeuble Walled AST Fuel Tank Make/Model SW-AST Serial or ID# 98.085 Manufactured Date na Design Capacity 10,000 gal Please attach a site diagram showing the equipment layout and general site dimensions for this re... https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_3n6PcSFe24UbQgt Have any other state or local regulatory agencies issued any other "Conditional Use Permits" for... No Operational Information: (Please note: Operating time over 16 hours in a 24 hour period will re... Total Hours of operation per 24 hr period 15 Starting time of operation (am/pm) 5:00 AM Ending time of operation (am/pm) 10:00 PM Maximum hourly production rate for project 500 tph Expected startup date 05/08/2023 Expected completion date 11/30/2023 What type of application is this for? New Application 5/3/23, 8:29 AM State of Utah Mail - Portable/Temporary Relocation Form https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1764806067150268394%7Cmsg-f:1764806067150268394&…3/3 In accordance with the fee schedule approved by the Utah State Legislature, the Division of Air Q... https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_W3EY4ul7oMhK29H Owner/Operator Representative: https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_2wGKMe9PI0jFUrj