HomeMy WebLinkAboutDDW-2024-008033CHECKLIST FOR LOCATING AND DEVELOPING A NEW DRINKING WATER SOURCE
To Do Before Construction
Preliminary Evaluation Report
Delineation Report
Request and obtain delineation report from the Division of Drinking Water (801-536-4200), or
Prepare a report meeting the requirements of R309-605
Susceptibility Analysis and Determination
Evaluate intake and sensitivity of the setting.
Request and obtain inventory of larger potential contamination sources from the Division of
Drinking Water.
Compile inventory of smaller Potential Contamination Sources within zones 1, 2 and 3 (as
applicable) from local information (you may use the inventory report form provided by
Division of Drinking Water (Appendix I), or your own method). You may rely on the
information provided by Division of Drinking Water for Potential Contamination Sources in
zone 4.
For each Potential Contamination Source (including those in zone 4), evaluate whether the
Potential Contamination Source is controlled or not controlled (the evaluation criteria are
included on the inventory form).
For each Potential Contamination Source, evaluate how susceptible your drinking water
source is to that Potential Contamination Source (you may use one of the susceptibility forms
(Appendix H) provided by the Division of Drinking Water for this, or you may provide your
own explanation for your susceptibility determinations).
Organize your inventory to reflect which Potential Contamination Sources represent the most
serious concern to your source water.
Land Use Map - A land use map which includes all land within zones one and two is required. You
may use existing maps or Geographic Information System data to satisfy this requirement. A land use
map and list are not required if ordinances are used to protect these areas. It is the responsibility of
the Public Water System to cite and quote references and interpret the zoning ordinance to
substantiate these restrictions. Please do not send a zoning ordinance and expect Division of Drinking
Water to do this research.
Documentation of Division of Water Quality classification of source water - with reference to
R317-2, provide documentation of the classification of the source waters by the Division of Water
Quality . If the source water is not currently classed as 1C under UAC R317-2, the Public Water
System must request such a classification from the Division of Water Quality for zones 1 and 2, and
must document the request. The Public Water System must also request that the source water be
categorized as Category 1 or 2 under UAC R317-2-3. Categorization of the source will reduce the
potential for source water degradation from new pollution sources.
Engineering Plans and Specifications -The pre-design submittal must be prepared and submitted to
the Engineering section. The Preliminary Evaluation Report must be concurrently prepared and
submitted to the Special Services Section. Following approval of the pre-design submittal and the
Preliminary Evaluation Report, the pre-construction submittal must be approved by the Engineering
section.