HomeMy WebLinkAboutDAQ-2024-006963
195 North 1950 West • Salt Lake City, UT
Mailing Address: P.O. Box 144820 • Salt Lake City, UT 84114-4820
Telephone (801) 536-4000 • Fax (801) 536-4099 • T.D.D. (801) 903-3978
www.deq.utah.gov
Printed on 100% recycled paper
State of Utah
Department of
Environmental Quality
Kimberly D. Shelley
Executive Director
DIVISION OF AIR QUALITY
Bryce C. Bird
Director
SPENCER J. COX
Governor
DEIDRE HENDERSON
Lieutenant Governor
DAQC-234-24
Site 14031 (B1)
Tyler Hodson
Kilgore Companies, LLC
7057 West 2100 South
Salt Lake City, Utah 84128
Dear Mr. Hodson:
Re: Kilgore Companies, LLC – Temporary Relocation/Operation, Notice of Intent – Tooele
County
Your Notice of Intent dated March 7, 2024, to relocate portable aggregate equipment to the
temporary project for the Kilgore Companies’ Stockton aggregate facility, located at 555 North
Highway 36, Stockton, Utah was received by the Utah Division of Air Quality (DAQ) and has
been reviewed.
The following equipment has been approved for operation for this temporary project:
KPI K-350 cone crusher
KPI/JCI screen
Bin feeder
The State of Utah has permitted portable equipment for Kilgore Contracting, LLC on the
Approval Order (AO) DAQE-AN129310019-18 dated April 12, 2018. The above referenced
location is a permitted aggregate facility with established equipment hours of operation and
production limits. All equipment operating at this site must be in accordance with the current
Stockton Facility AO DAQE-AN140310004-22 dated December 22, 2022. The production of
aggregate from all temporary projects when combined with the permanent equipment’s production
cannot exceed the 12-month rolling limits as per Condition II.B.1.a of this AO. The operation of
the equipment must be compliant with this facility’s hourly limits as established by Conditions
II.B.1.b, II.B.1.c, II.B.1.d, and II.B.1.e.
/ % Ú â Û Ù Û Ý
DAQC-234-24
Page 2
Approval is granted to relocate and operate this equipment at the new location for a period not to
exceed 180 operational days. As per Utah Administrative Code (UAC) R307-401-17, the
operation of equipment at this temporary site may be for up to 180 working days in any calendar
year not to exceed 365 consecutive days, starting from the initial relocation date.
The owner/operator shall maintain records of the actual operation hours, days, and production
rate, of the above referenced equipment at this relocation site and have the ability to submit the
information to the DAQ upon the request of representatives of the director. Please make certain
that the plant operator is aware of all the location specific requirements for this site and the
conditions of the aforementioned AO.
Federal New Source Performance Standards Subpart OOO requires that initial Method 9
observations be performed for all applicable portable crushers, screens and attached conveyors.
Subpart OOO also mandates that all crushers constructed, modified, or reconstructed on or after
April 22, 2008, which are not enclosed, must install spray bars on the equipment and keep
maintenance records to ensure proper spray bar operations.
Utah Division of Water Quality Storm Water Permits and regulations may apply to this temporary
project. Please refer to Utah DEQ Water Quality’s current Storm Water Construction
requirements for additional information.
This approval for relocation in no way releases the owner or operator from any liability for
compliance with all other applicable federal, state, and local regulations including the UAC.
If you have any questions regarding this relocation authorization or the temporary relocation
process please contact Susan Weisenberg at (385) 306-6512.
Sincerely,
Jay P. Morris
Assistant Director
JPM:SW:rh
Enclosure: Submitted Temporary Relocation Form
cc: Tooele County Health Department
4 * - - $ . — - @ G v A ? A C @ ? w ? E ˜
3/7/24, 6:12 PM State of Utah Mail - Portable/Temporary Relocation Form
https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1792900993451492653%7Cmsg-f:1792914340619951788&…1/2
Susan Weisenberg <sweisenberg@utah.gov>
Portable/Temporary Relocation Form
1 message
noreply@qemailserver.com <noreply@qemailserver.com>Thu, Mar 7, 2024 at 5:05 PM
Reply-To: trigger@qemailserver.com
To: sweisenberg@utah.gov
Susan/Chad:
Site # -- Kilgore Companies LLC has requested a Temporary Relocation. Please see the information below. Any
attachments can be access by clicking on the links.
Recipient Data:
Time Finished: 2024-03-07 17:05:46 MST
IP: 165.225.11.1
ResponseID: R_5fC10KX3PBNuq9H
Link to View Results: Click Here
URL to View Results: https://utahgov.iad1.qualtrics.com/apps/single-response-reports/reports/
s6icjpFt6HIzl85Yd5aBvExnvIZ6NPiNM5a2UCBUgufSfk-n%2EsJj0DHTHFTk6NpGilPoFrnPMwjEJ3s6F04g-
Uod6v3EhQCQFGwtzj1lbNOv9GWrkvj5rXyv1UkQPEEOeBtwOyk8cftDKWNIi61KD7iHmi0FhlBNqrVdEMTJwEC9yBb
1xdKLaV4pAEijBYxRhIWOPyJWkE35RLlzJP6ii3m83S9OwDN8Ljv-0ngI8voGjIy7qAtAvjGzgIWdWZ5iQv
Zqdi0LuCftO4aIw2fSp81bwqAZl-OhYkOXvChzTIflEMRh7Stt98nEVWdIBgBhFw0NN5rzTBZgv3uv3KnnGg
Response Summary:
Please fill out the information below:
Contact Person: Tyler Hodson
Company Name: Kilgore Companies LLC
Mailing Address: 7057 W 2100 S
City: Salt Lake City
Zip: 84128
Phone Number: 3852283653
Email: Tyler.hodson@kilgorecompanies.com
Is the site located within a PM2.5 non-attainment and maintenance plan areas on cleared land grea...
Yes
All temporary relocation projects are required to submit a Fugitive Dust Control Plan (FDCP). Lo...
C7B8A482E8
Briefly give directions to the site and/or physical address:
From I-80 take exit 99 onto UT-36. Take highway 36 south for about 19 miles before approaching site on the right side
(west) marked with Kilgore Companies sign.
Proposed Relocation Information:
Closest City Stockton
County Tooele
UTM X Coordinates 384960.19 E
UTM Y Coordinates 4480007.72 N
Approximate distance to the nearest house/business 1,491 feet
UTM X Coordinates to nearest house/business 384774.51 E
UTM Y Coordinates to nearest house/business 4479523.11 N
Does this site currently have a permit with DAQ?
3/7/24, 6:12 PM State of Utah Mail - Portable/Temporary Relocation Form
https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1792900993451492653%7Cmsg-f:1792914340619951788&…2/2
Yes
If yes, what is the Permit (DAQ-AN) # ?
140310004-22
If yes, what is the Permit Holder's Name?
Kilgore Companies
Please provide the permit ID for the equipment? (DAQE-XXXXXXXXX-XX)
DAQE-AN129310019-18
Please list all the Equipment on Site:Note: It is important to identify ALL diesel powered engine...
1
Equipment Type Cone Crusher
Make/Model KPI K-350
Serial or ID# B22071A10066C003
Manufactured Date 2023
Design Capacity 400 tph
2
Equipment Type Screen
Make/Model KPI/JCI Screen
Serial or ID# S102538
Manufactured Date 2010
Design Capacity 400 tph
3
Equipment Type Bin Feeder
Make/Model Goodfellow W010053-1
Serial or ID# A22071A10063
Manufactured Date 2023
Design Capacity tph
Please attach a site diagram showing the equipment layout and general site dimensions for this re...
https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_1dMqjEu2RYEvpgQ
Have any other state or local regulatory agencies issued any other "Conditional Use Permits" for...
No
Operational Information: (Please note: Operating time over 16 hours in a 24 hour period will re...
Total Hours of operation per 24 hr period 12
Starting time of operation (am/pm) 6 am
Ending time of operation (am/pm) 6 pm
Maximum hourly production rate for project 150 tph
Expected startup date 03/11/2024
Expected completion date 03/11/2025
What type of application is this for?
New Application
In accordance with the fee schedule approved by the Utah State Legislature, the Division of Air Q...
https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_1mmW9HmWoC9DQvo
Owner/Operator Representative:
https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_3J3qLz8x1fjS24t
3/11/24, 10:35 AM State of Utah Mail - RE: generator question regarding TRP to Stockton
https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-a:r-4037495700619495456%7Cmsg-f:179299024778892652…1/2
Susan Weisenberg <sweisenberg@utah.gov>
RE: generator question regarding TRP to Stockton
1 message
Tyler Hodson <Tyler.Hodson@kilgorecompanies.com>Fri, Mar 8, 2024 at 1:12 PM
To: Susan Weisenberg <sweisenberg@utah.gov>
Cc: Lee Ware <Lee.Ware@kilgorecompanies.com>, Bryan Jorgensen <Bryan.Jorgensen@kilgorecompanies.com>
Hi Susan,
I can confirm that there will not be a generator brought on site and this equipment will be run on line power.
Thank you,
Tyler Hodson
Administrative Environmental Manager
(385)228-3653
Tyler.hodson@kilgorecompanies.com
From: Susan Weisenberg <sweisenberg@utah.gov>
Sent: Thursday, March 7, 2024 6:18 PM
To: Tyler Hodson <Tyler.Hodson@kilgorecompanies.com>
Subject: generator ques on regarding TRP to Stockton
This message originated from outside your organization
Hello Tyler, I received the relocation submission for Stockton this morning and I noticed that there's not a reference to a generator.
Can you let me know if this equipment will be powered by an electrical line or if there will be a diesel fueled generator?
Thanks
Susan Weisenberg,
3/11/24, 10:35 AM State of Utah Mail - RE: generator question regarding TRP to Stockton
https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-a:r-4037495700619495456%7Cmsg-f:179299024778892652…2/2
Environmental Scientist
Office: 385-306-6512