Loading...
HomeMy WebLinkAboutDAQ-2024-006963 195 North 1950 West • Salt Lake City, UT Mailing Address: P.O. Box 144820 • Salt Lake City, UT 84114-4820 Telephone (801) 536-4000 • Fax (801) 536-4099 • T.D.D. (801) 903-3978 www.deq.utah.gov Printed on 100% recycled paper State of Utah Department of Environmental Quality Kimberly D. Shelley Executive Director DIVISION OF AIR QUALITY Bryce C. Bird Director SPENCER J. COX Governor DEIDRE HENDERSON Lieutenant Governor DAQC-234-24 Site 14031 (B1) Tyler Hodson Kilgore Companies, LLC 7057 West 2100 South Salt Lake City, Utah 84128 Dear Mr. Hodson: Re: Kilgore Companies, LLC – Temporary Relocation/Operation, Notice of Intent – Tooele County Your Notice of Intent dated March 7, 2024, to relocate portable aggregate equipment to the temporary project for the Kilgore Companies’ Stockton aggregate facility, located at 555 North Highway 36, Stockton, Utah was received by the Utah Division of Air Quality (DAQ) and has been reviewed. The following equipment has been approved for operation for this temporary project: KPI K-350 cone crusher KPI/JCI screen Bin feeder The State of Utah has permitted portable equipment for Kilgore Contracting, LLC on the Approval Order (AO) DAQE-AN129310019-18 dated April 12, 2018. The above referenced location is a permitted aggregate facility with established equipment hours of operation and production limits. All equipment operating at this site must be in accordance with the current Stockton Facility AO DAQE-AN140310004-22 dated December 22, 2022. The production of aggregate from all temporary projects when combined with the permanent equipment’s production cannot exceed the 12-month rolling limits as per Condition II.B.1.a of this AO. The operation of the equipment must be compliant with this facility’s hourly limits as established by Conditions II.B.1.b, II.B.1.c, II.B.1.d, and II.B.1.e. / % Ú â Û Ù Û Ý DAQC-234-24 Page 2 Approval is granted to relocate and operate this equipment at the new location for a period not to exceed 180 operational days. As per Utah Administrative Code (UAC) R307-401-17, the operation of equipment at this temporary site may be for up to 180 working days in any calendar year not to exceed 365 consecutive days, starting from the initial relocation date. The owner/operator shall maintain records of the actual operation hours, days, and production rate, of the above referenced equipment at this relocation site and have the ability to submit the information to the DAQ upon the request of representatives of the director. Please make certain that the plant operator is aware of all the location specific requirements for this site and the conditions of the aforementioned AO. Federal New Source Performance Standards Subpart OOO requires that initial Method 9 observations be performed for all applicable portable crushers, screens and attached conveyors. Subpart OOO also mandates that all crushers constructed, modified, or reconstructed on or after April 22, 2008, which are not enclosed, must install spray bars on the equipment and keep maintenance records to ensure proper spray bar operations. Utah Division of Water Quality Storm Water Permits and regulations may apply to this temporary project. Please refer to Utah DEQ Water Quality’s current Storm Water Construction requirements for additional information. This approval for relocation in no way releases the owner or operator from any liability for compliance with all other applicable federal, state, and local regulations including the UAC. If you have any questions regarding this relocation authorization or the temporary relocation process please contact Susan Weisenberg at (385) 306-6512. Sincerely, Jay P. Morris Assistant Director JPM:SW:rh Enclosure: Submitted Temporary Relocation Form cc: Tooele County Health Department 4 * - - $ . — - @ G v A ? A C @ ? w ? E ˜ 3/7/24, 6:12 PM State of Utah Mail - Portable/Temporary Relocation Form https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1792900993451492653%7Cmsg-f:1792914340619951788&…1/2 Susan Weisenberg <sweisenberg@utah.gov> Portable/Temporary Relocation Form 1 message noreply@qemailserver.com <noreply@qemailserver.com>Thu, Mar 7, 2024 at 5:05 PM Reply-To: trigger@qemailserver.com To: sweisenberg@utah.gov Susan/Chad: Site # -- Kilgore Companies LLC has requested a Temporary Relocation. Please see the information below. Any attachments can be access by clicking on the links. Recipient Data: Time Finished: 2024-03-07 17:05:46 MST IP: 165.225.11.1 ResponseID: R_5fC10KX3PBNuq9H Link to View Results: Click Here URL to View Results: https://utahgov.iad1.qualtrics.com/apps/single-response-reports/reports/ s6icjpFt6HIzl85Yd5aBvExnvIZ6NPiNM5a2UCBUgufSfk-n%2EsJj0DHTHFTk6NpGilPoFrnPMwjEJ3s6F04g- Uod6v3EhQCQFGwtzj1lbNOv9GWrkvj5rXyv1UkQPEEOeBtwOyk8cftDKWNIi61KD7iHmi0FhlBNqrVdEMTJwEC9yBb 1xdKLaV4pAEijBYxRhIWOPyJWkE35RLlzJP6ii3m83S9OwDN8Ljv-0ngI8voGjIy7qAtAvjGzgIWdWZ5iQv Zqdi0LuCftO4aIw2fSp81bwqAZl-OhYkOXvChzTIflEMRh7Stt98nEVWdIBgBhFw0NN5rzTBZgv3uv3KnnGg Response Summary: Please fill out the information below: Contact Person: Tyler Hodson Company Name: Kilgore Companies LLC Mailing Address: 7057 W 2100 S City: Salt Lake City Zip: 84128 Phone Number: 3852283653 Email: Tyler.hodson@kilgorecompanies.com Is the site located within a PM2.5 non-attainment and maintenance plan areas on cleared land grea... Yes All temporary relocation projects are required to submit a Fugitive Dust Control Plan (FDCP). Lo... C7B8A482E8 Briefly give directions to the site and/or physical address: From I-80 take exit 99 onto UT-36. Take highway 36 south for about 19 miles before approaching site on the right side (west) marked with Kilgore Companies sign. Proposed Relocation Information: Closest City Stockton County Tooele UTM X Coordinates 384960.19 E UTM Y Coordinates 4480007.72 N Approximate distance to the nearest house/business 1,491 feet UTM X Coordinates to nearest house/business 384774.51 E UTM Y Coordinates to nearest house/business 4479523.11 N Does this site currently have a permit with DAQ? 3/7/24, 6:12 PM State of Utah Mail - Portable/Temporary Relocation Form https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1792900993451492653%7Cmsg-f:1792914340619951788&…2/2 Yes If yes, what is the Permit (DAQ-AN) # ? 140310004-22 If yes, what is the Permit Holder's Name? Kilgore Companies Please provide the permit ID for the equipment? (DAQE-XXXXXXXXX-XX) DAQE-AN129310019-18 Please list all the Equipment on Site:Note: It is important to identify ALL diesel powered engine... 1 Equipment Type Cone Crusher Make/Model KPI K-350 Serial or ID# B22071A10066C003 Manufactured Date 2023 Design Capacity 400 tph 2 Equipment Type Screen Make/Model KPI/JCI Screen Serial or ID# S102538 Manufactured Date 2010 Design Capacity 400 tph 3 Equipment Type Bin Feeder Make/Model Goodfellow W010053-1 Serial or ID# A22071A10063 Manufactured Date 2023 Design Capacity tph Please attach a site diagram showing the equipment layout and general site dimensions for this re... https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_1dMqjEu2RYEvpgQ Have any other state or local regulatory agencies issued any other "Conditional Use Permits" for... No Operational Information: (Please note: Operating time over 16 hours in a 24 hour period will re... Total Hours of operation per 24 hr period 12 Starting time of operation (am/pm) 6 am Ending time of operation (am/pm) 6 pm Maximum hourly production rate for project 150 tph Expected startup date 03/11/2024 Expected completion date 03/11/2025 What type of application is this for? New Application In accordance with the fee schedule approved by the Utah State Legislature, the Division of Air Q... https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_1mmW9HmWoC9DQvo Owner/Operator Representative: https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_3J3qLz8x1fjS24t 3/11/24, 10:35 AM State of Utah Mail - RE: generator question regarding TRP to Stockton https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-a:r-4037495700619495456%7Cmsg-f:179299024778892652…1/2 Susan Weisenberg <sweisenberg@utah.gov> RE: generator question regarding TRP to Stockton 1 message Tyler Hodson <Tyler.Hodson@kilgorecompanies.com>Fri, Mar 8, 2024 at 1:12 PM To: Susan Weisenberg <sweisenberg@utah.gov> Cc: Lee Ware <Lee.Ware@kilgorecompanies.com>, Bryan Jorgensen <Bryan.Jorgensen@kilgorecompanies.com> Hi Susan, I can confirm that there will not be a generator brought on site and this equipment will be run on line power. Thank you, Tyler Hodson Administrative Environmental Manager (385)228-3653 Tyler.hodson@kilgorecompanies.com From: Susan Weisenberg <sweisenberg@utah.gov> Sent: Thursday, March 7, 2024 6:18 PM To: Tyler Hodson <Tyler.Hodson@kilgorecompanies.com> Subject: generator queson regarding TRP to Stockton This message originated from outside your organization Hello Tyler, I received the relocation submission for Stockton this morning and I noticed that there's not a reference to a generator. Can you let me know if this equipment will be powered by an electrical line or if there will be a diesel fueled generator? Thanks Susan Weisenberg, 3/11/24, 10:35 AM State of Utah Mail - RE: generator question regarding TRP to Stockton https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-a:r-4037495700619495456%7Cmsg-f:179299024778892652…2/2 Environmental Scientist Office: 385-306-6512