Loading...
HomeMy WebLinkAboutDERR-2024-00756024005468.001A/SLC24M167863 Page 1 of 2 May 17, 2024 © 2024 Kleinfelder www.kleinfelder.com 849 West Levoy Drive, Suite 200, Taylorsville, UT 84123-2544 p | 801.261.3336 f | 801.261.3306 May 17, 2024 Kleinfelder Project No.: 24005486.001A Mr. Mark Crim Project Manager Utah Department of Environmental Quality Division of Environmental Response and Remediation 195 North 1950 West Salt Lake City, Utah 84116 SUBJECT: Monitoring and Vent Well Location and Exposure Work Assignment GQJ-88-KLE Milford Chevron, Milford, Utah Facility Identification No. 6000171, Release Site GQJ Dear Mr. Crim: Kleinfelder completed the scope of work consisting of locating and exposing one monitoring well and two vent wells included in work assignment GQJ-88-KLE on May 1 and 2, 2024. Kleinfelder’s field staff met with Terry and Wayne Wiseman and Paul and Melissa Wunderlich at Scotty’s Diner, in Milford, Utah. Upon arrival, Kleinfelder began searching for the three monitoring and soil-vent wells. After locating each well, Kleinfelder assessed the condition of the well completion, the well casing, and the well backfill (to the extent possible). If the well completion was covered with gravel or other fill material, Kleinfelder used a metal detector to search for the metal well vault. Each located well was gauged with an oil/water interface probe. All wells assessed as part of this scope of work were dry or only contained residual water in the bottom of the casing. Monitoring well MW-27 and vent well VW-16 were found north of the Site, behind a historical building that is currently being renovated. MW-27 was found approximately two inches below the surface of some fill material and VW-16 was visibly sticking out of the ground (Attachment 1). VW-13 was found in the northeast corner of the Scotty’s Diner property under approximately three inches of gravel (Attachment 1). 24005468.001A/SLC24M167863 Page 2 of 2 May 17, 2024 © 2024 Kleinfelder www.kleinfelder.com KLEINFELDER 849 West Levoy Drive, Suite 200, Taylorsville, UT 84123-2544 p | 801.261.3336 f | 801.261.3306 A summary of the well inspection and assessment activities is included in Table 1, attached to this letter. Additionally, the Site Map (Figure 1) has been updated to show the actual locations of the three wells that were located during this investigation. Sincerely, KLEINFELDER, INC. Matt Ellison, PG Mike Gronseth, PE, PG, PMP Project Professional Senior Project Manager ATTACHMENTS Attachment 1 – Photographic Log Table 1 – Well Information Summary Figure 1 – Well Location Map At t a c h m e n t 1 www.kleinfelder.com 1. View of MW-27 when it was first uncovered. PROJECT NO.:Attachment:SUBJECT PROPERTY PHOTOGRAPHS 1DRAWN BY: DRAWN: CHECKED BY: FILE NAME: MG Original in Color 2. View of MW-27 after a PVC cap was added / painted and the area around it was backfilled. SLC24M167863 5/14/2024 24005486.001A ME MILFORD CHEVRON 402 SOUTH MAIN STREET MILFORD, UTAH www.kleinfelder.com 3. View of VW-16 with the excavation around it exposed. PROJECT NO.:Attachment:SUBJECT PROPERTY PHOTOGRAPHS 1DRAWN BY: DRAWN: CHECKED BY: FILE NAME: MG Original in Color 4. View of VW-16 after a PVC cap was added / painted and the area around it was backfilled. SLC24M167863 5/14/2024 24005486.001A ME MILFORD CHEVRON 402 SOUTH MAIN STREET MILFORD, UTAH www.kleinfelder.com 5. View of VW-13 just after it was located and uncovered. PROJECT NO.:Attachment:SUBJECT PROPERTY PHOTOGRAPHS 1DRAWN BY: DRAWN: CHECKED BY: FILE NAME: MG Original in Color 6. View of VW-13 after measuring depth to water, total depth, painting the well cap, and backfilling the surrounding excavation. SLC24M167863 5/14/2024 24005486.001A ME MILFORD CHEVRON 402 SOUTH MAIN STREET MILFORD, UTAH Ta b l e s Well Casing Product Top of Static Product Total Casing Number Stick-up in Well? Product Water Level Thickness Depth Diameter Cap Lock Comments (ft) Yes \ No (ft btoc) (ft btoc) (ft) (ft btoc) (in) Good Fair Poor Yes No Yes No MW‐27 0.25 No N/A Dry N/A 31.47 2 Yes No X X No concrete collar or well vault. VW‐13 0 No N/A 26.69 N/A 26.79 4 Yes Yes X X X Not under Diner's refridgerator connex. VW‐16 0.5 No N/A Dry N/A 29.23 4 No No X X No concrete collar or well vault. Very thin PVC - not schedule 40. Ft = feet btoc = below top of casing In = inch N/A = not applicable Table 1 Milford Chevron GQJ-89-KLE - Milford, Utah Well Evaluation Summary Yes or No Security Concrete Collar Well Vault Cover Intact Cover Bolts 24005468.001A/SLC24M167863 © 2024 Kleinfelder Page 1 of 1 May 17, 2024 Fi g u r e s VW-16 VW-13 MW-27 LEGEND MONITORING WELL LOCATION VENT WELL LOCATION The information included on this graphic representation has been compiled from a variety of sources and is subject to change without notice. Kleinfelder makes no representations or warranties, express or implied, as to accuracy, completeness, timeliness, or rights to the use of such information. This document is not intended for use as a land survey product nor is it designed or intended as a construction design document. The use or misuse of the information contained on this graphic representation is at the sole risk of the party using or misusing the information.www.kleinfelder.com WELL LOCATION MAP MILFORD CHEVRON 402 SOUTH MAIN STREET MILFORD, UTAH FIGURE 1 0 50 100 SCALE IN FEET Locations are Approximate PROJECT NO.: DRAWN: DRAWN BY: CHECKED BY: FILE NAME: Milford_Figs.mxd 24005486 MAY 2024 RA ME Project Location L: \ 2 0 2 2 \ 2 0 2 2 4 9 1 2 . 0 0 1 A - S L C C o r p P M A A G u n R a n g e \ 2 . 0 T e c h n i c a l I n f o r m a t i o n \ 2 . 8 G I S SA L T L A K E C I T Y , U T PL O T T E D : 5 / 1 7 / 2 0 2 4 , R A l v a r e z National Geographic, Esri, Garmin, HERE, UNEP-WCMC, USGS, NASA, ESA, METI, NRCAN, GEBCO, NOAA, increment P Corp., © 2024 Microsoft Corporation © 2024 Maxar ©CNES (2024) Distribution Airbus DS © 2024 TomTom