Loading...
HomeMy WebLinkAboutDAQ-2024-004299 195 North 1950 West • Salt Lake City, UT Mailing Address: P.O. Box 144820 • Salt Lake City, UT 84114-4820 Telephone (801) 536-4000 • Fax (801) 536-4099 • T.D.D. (801) 903-3978 www.deq.utah.gov Printed on 100% recycled paper State of Utah Department of Environmental Quality Kimberly D. Shelley Executive Director DIVISION OF AIR QUALITY Bryce C. Bird Director SPENCER J. COX Governor DEIDRE HENDERSON Lieutenant Governor DAQC-1302-23 Site 13273 (B1) Tyler Hodson Kilgore Companies dba LeGrand Johnson 7057 West 2100 South West Valley City, Utah 84128 Dear Mr. Hodson: Re: Kilgore Companies dba Legrand Johnson –Temporary Relocation/Operation, Notice of Intent – Box Elder County Your Notice of Intent dated November 27, 2023, to relocate portable aggregate equipment to the temporary project for Legrand Johnson’s Knudson Pit, located at 1200 East 700 South, Brigham City, Utah was received by the Utah Division of Air Quality (DAQ) and has been reviewed. The following equipment has been approved for operation for this temporary project: JCI-KPI screen with 129 hp diesel engine Terex/Finley screen with 113 hp diesel engine The State of Utah has permitted portable aggregate equipment for operation for your company on the Approval Order (AO) DAQE-AN129310019-18 dated April 12, 2018. The above location is a permitted aggregate facility with established equipment hours of operation and production limits. All equipment operating at this site must be in accordance with the current Approval Order (AO) for this site DAQE-AN132730007-17 dated June 2, 2017. The production of aggregate from all temporary projects when combined with the permanent equipment’s production cannot exceed the 12-month rolling limits as per Condition II.B.1.a of this AO. As per Condition II.B.1.b of this same AO, the referenced equipment can only operate between 6:00 am and 6:00 pm and shall operate for a maximum of 10 hours per day. Approval is granted to relocate and operate this equipment at the new location for a period not to exceed 180 operational days. As per Utah Administrative Code (UAC) R307-401-17, the operation of equipment at this temporary site may be for up to 180 working days in any calendar year not to exceed 365 consecutive days, starting from the initial relocation date. The operational days per site cannot be extended beyond the stipulated 365 consecutive day period. " " * " / ß Û Ù Û Ü DAQC-1302-23 Page 2 The owner/operator shall maintain records of the actual operation hours, days, and production rate, of the above referenced equipment at this relocation site and have the ability to submit the information to the DAQ upon the request of representatives of the director. Please make certain that the plant operator is aware of all the location specific requirements for this site and the conditions of the aforementioned AO. Federal New Source Performance Standards Subpart OOO requires that initial Method 9 observations be performed for all applicable portable crushers, screens and attached conveyors. Subpart OOO also mandates that all crushers constructed, modified, or reconstructed on or after April 22, 2008, which are not enclosed, must install spray bars on the equipment and keep maintenance records to ensure proper spray bar operations. Utah Division of Water Quality Storm Water Permits and regulations may apply to this temporary project. Please refer to Utah DEQ Water Quality’s current Storm Water Construction requirements for additional information. This approval for relocation in no way releases the owner or operator from any liability for compliance with all other applicable federal, state, and local regulations including the UAC. If you have any questions regarding this relocation authorization or the temporary relocation process please contact Susan Weisenberg at (385) 306-6512. Sincerely, Jay P. Morris Assistant Director JPM:SW:rh Enclosure: Submitted Temporary Relocation Form cc: Bear River Health Department 4 * - - $ . — D v A ? A B @ C w D A ˜ 11/30/23, 10:56 AM State of Utah Mail - Portable/Temporary Relocation Form https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1783742386039940151%7Cmsg-f:1783742386039940151&…1/2 Susan Weisenberg <sweisenberg@utah.gov> Portable/Temporary Relocation Form 1 message noreply@qemailserver.com <noreply@qemailserver.com>Mon, Nov 27, 2023 at 11:21 AM Reply-To: trigger@qemailserver.com To: sweisenberg@utah.gov Susan/Chad: Site # -- Kilgore Companies dba LeGrand Johnson has requested a Temporary Relocation. Please see the information below. Any attachments can be access by clicking on the links. Recipient Data: Time Finished: 2023-11-27 11:21:26 MST IP: 136.226.86.253 ResponseID: R_264nD9cizz7NN5P Link to View Results: Click Here URL to View Results: https://utahgov.iad1.qualtrics.com/apps/single-response-reports/reports/ QTkLlCidShh3B8Mwvdxlyqr%2ETKcuUuBqCsVuiLFCPjz4iWkHhS%2ESBG4HIxWERU7HUCn5El%2EOkpc2TROpm1l% 2EwKnD9UnqkUNMIZ6q21GRI9af3UMDrP7KSQjpd%2EcXPhEubCAK5vcFqIXCwnVAis7tAI 8yI94k8RUchSnJK%2En2fOSAKCo%2EFdJ%2EUTuxRXUU4I-ePEqwg7TuRRUZ% 2E54Ne0IxiwBtOMOe6K0vx6s4vuTkqCYKbtWFvPmVMXi0hvtbf8U8hN9BaEl%2E12PS6UJgW3SjUpPxukSqEHY4GtFc 96p80ibvmRD0ALZB5ohRelI9aM0c1jXlNvkXesnQVLY3yLF7Sw Response Summary: Please fill out the information below: Contact Person: Tyler Hodson Company Name: Kilgore Companies dba LeGrand Johnson Mailing Address: 7057 W 2100 S City: West Valley City Zip: 84128 Phone Number: 3852283653 Email: Tyler.hodson@kilgorecompanies.com Is the site located within a PM2.5 non-attainment and maintenance plan areas on cleared land grea... No All temporary relocation projects are required to submit a Fugitive Dust Control Plan (FDCP). Lo... 21A2BBD5B1 Briefly give directions to the site and/or physical address: After taking exit 362 off I-15 proceed east along US-91 about 3.5 miles to the aggregate pit turnoff on the east side of the road. Proposed Relocation Information: Closest City Brigham City County Box Elder UTM X Coordinates 417217.53 UTM Y Coordinates 4594368.06 Approximate distance to the nearest house/business 1,131 feet UTM X Coordinates to nearest house/business 417061.34 UTM Y Coordinates to nearest house/business 4594869.51 11/30/23, 10:56 AM State of Utah Mail - Portable/Temporary Relocation Form https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1783742386039940151%7Cmsg-f:1783742386039940151&…2/2 Does this site currently have a permit with DAQ? Yes If yes, what is the Permit (DAQ-AN) # ? 12930019-18 If yes, what is the Permit Holder's Name? Lee Ware Please provide the permit ID for the equipment? (DAQE-XXXXXXXXX-XX) DAQE-AN129310019-18 Please list all the Equipment on Site:Note: It is important to identify ALL diesel powered engine... 1 Equipment Type Screen Make/Model JCI-KPI GT205S Serial or ID# 214922 Manufactured Date 12/2019 Design Capacity 100 2 Equipment Type Screen Make/Model Terex/Finley 684 Serial or ID# TRX01684EDGM65639 Manufactured Date 06/2021 Design Capacity 100 Please attach a site diagram showing the equipment layout and general site dimensions for this re... https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_2SHsqVC6byBduWd Have any other state or local regulatory agencies issued any other "Conditional Use Permits" for... No Operational Information: (Please note: Operating time over 16 hours in a 24 hour period will re... Total Hours of operation per 24 hr period 12 Starting time of operation (am/pm) 5 am Ending time of operation (am/pm) 5 pm Maximum hourly production rate for project 200 tons per hour Expected startup date 11/27/2023 Expected completion date 03/29/2024 What type of application is this for? New Application In accordance with the fee schedule approved by the Utah State Legislature, the Division of Air Q... https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_11YGejYl8WGmY5v Owner/Operator Representative: https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_2vi7P8ctBh0EINA 11/29/23, 9:41 AM State of Utah Mail - RE: Screen TRP to Knudson Pit https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-a:r-3833534671519841743%7Cmsg-f:178391723381509249…1/2 Susan Weisenberg <sweisenberg@utah.gov> RE: Screen TRP to Knudson Pit 1 message Tyler Hodson <Tyler.Hodson@kilgorecompanies.com>Wed, Nov 29, 2023 at 9:40 AM To: Susan Weisenberg <sweisenberg@utah.gov> Hello Susan, For these screens they are self-driven by diesel engines. For the JDI-KPI GT205S it has a 129 hp diesel engine and for the Terex/Finlay 684 it has a 113 hp diesel engine. Thank you, Tyler Hodson Environmental Compliance Coordinator (385)228-3653 Tyler.hodson@kilgorecompanies.com From: Susan Weisenberg <sweisenberg@utah.gov> Sent: Tuesday, November 28, 2023 2:58 PM To: Tyler Hodson <Tyler.Hodson@kilgorecompanies.com> Subject: Screen TRP to Knudson Pit This message originated from outside your organization Hello, I have the TRP Letter prepared for the two screens to the Brigham City Pit. Can you let me know if the screens will be powered by an additional generator or will the equipment just be added to the current generator set up? Thanks Susan Weisenberg, Environmental Scientist Office: 385-306-6512 11/29/23, 9:41 AM State of Utah Mail - RE: Screen TRP to Knudson Pit https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-a:r-3833534671519841743%7Cmsg-f:178391723381509249…2/2