HomeMy WebLinkAboutDAQ-2024-004268
195 North 1950 West • Salt Lake City, UT
Mailing Address: P.O. Box 144820 • Salt Lake City, UT 84114-4820
Telephone (801) 536-4000 • Fax (801) 536-4099 • T.D.D. (801) 903-3978
www.deq.utah.gov
Printed on 100% recycled paper
State of Utah
Department of
Environmental Quality
Kimberly D. Shelley
Executive Director
DIVISION OF AIR QUALITY
Bryce C. Bird
Director
SPENCER J. COX
Governor
DEIDRE HENDERSON
Lieutenant Governor
DAQC-033-24
Site 13099 (B1)
Christian Boudreau
Staker Parson Companies
89 West 13490 South, Suite 100
Draper, Utah 84020
Dear Mr. Boudreau:
Re: Staker Parson Companies – Temporary Relocation/Operation, Notice of Intent – Salt Lake
County
Your Notice of Intent dated January 9, 2024, to relocate portable aggregate equipment to the
temporary project for Staker Parson, located at 1730 North Beck Street, Salt Lake City, Utah, was
received by the Utah Division of Air Quality (DAQ) and has been reviewed.
The following equipment has been approved for operation for this temporary project:
II.A.6 cone crusher
II.A.126 impact crusher
II.A.174 two (2) screens
II.A.762 745 generator
The State of Utah has permitted portable equipment for Staker Parson Companies on the Approval
Order DAQE-AN115180014-15 dated July 6, 2015. The above location is a permitted aggregate
facility with established equipment hours of operation and production limits. All equipment
operating at this site must be in accordance with the current Approval Order (AO) for this site
DAQE-AN0130990004-09 dated October 21, 2009. The production of aggregate from all
temporary projects when combined with the permanent equipment’s production cannot exceed the
12-month rolling limits as per Condition II.B.2.A of this AO. The generator use shall comply with
all applicable conditions for diesel engine operation.
+ 2 / 6 Ú Û Û Ù Û Ý
DAQC-033-24
Page 2
Approval is granted to relocate and operate this equipment at the new location for a period not to
exceed 180 operational days. As per Utah Administrative Code (UAC) R307-401-17, the
operation of equipment at this temporary site may be for up to 180 working days in any calendar
year not to exceed 365 consecutive days, starting from the initial relocation date. The operational
days per site cannot be extended beyond the stipulated 365 consecutive day period.
The owner/operator shall maintain records of the actual operation hours, days, and production
rate, of the above referenced equipment at this relocation site and have the ability to submit the
information to the DAQ upon the request of representatives of the director. Please make certain
that the plant operator is aware of all the location specific requirements for this site and the
conditions of the aforementioned AO.
Federal New Source Performance Standards Subpart OOO requires that initial Method 9
observations be performed for all applicable portable crushers, screens, and attached conveyors.
Subpart OOO also mandates that all crushers constructed, modified, or reconstructed on or after
April 22, 2008, which are not enclosed, must install spray bars on the equipment and keep
maintenance records to ensure proper spray bar operations.
Utah Division of Water Quality Storm Water Permits and regulations may apply to this temporary
project. Please refer to Utah DEQ Water Quality’s current Storm Water Construction
requirements for additional information.
This approval for relocation in no way releases the owner or operator from any liability for
compliance with all other applicable federal, state, and local regulations including the UAC.
If you have any questions regarding this relocation authorization or the temporary relocation
process, please contact Susan Weisenberg at (385) 306-6512.
Sincerely,
Jay P. Morris
Assistant Director
JPM:SW:rh
Enclosure: Submitted Temporary Relocation Form
cc: Salt Lake County Health Department
4 * - - $ . — ) @ @ v A ? A C @ B w D E ˜
1/10/24, 10:55 AM State of Utah Mail - Portable/Temporary Relocation Form
https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1787647152367629348%7Cmsg-f:1787647152367629348&…1/2
Susan Weisenberg <sweisenberg@utah.gov>
Portable/Temporary Relocation Form
1 message
noreply@qemailserver.com <noreply@qemailserver.com>Tue, Jan 9, 2024 at 1:46 PM
Reply-To: trigger@qemailserver.com
To: sweisenberg@utah.gov
Susan/Chad:
Site # -- Staker Parson has requested a Temporary Relocation. Please see the information below. Any attachments can
be access by clicking on the links.
Recipient Data:
Time Finished: 2024-01-09 13:45:59 MST
IP: 67.182.223.139
ResponseID: R_14W78nNEV63IWWZ
Link to View Results: Click Here
URL to View Results: https://utahgov.iad1.qualtrics.com/apps/single-response-reports/reports/
mH98n49hVZAvuBHgMjHLHV8Ggva-lp0crAadWa3lIahihGU6mg2QKVtShh7bYLUMP50oRm0Tr7--
gtLxDcGeyS4tN0BHLpgUbD4RVWWYw3brvqZUeUkL3ObUaPpjCk5zh6xlWryYjN5blcW6mdk-sN9%
2ErW4Ver47pjHJtjHflWxiECEqTcCu2oxDwP9oBc6NpunnOfYprTeuk537rBm-VqX3MFKIm-
zp7rHIS4vKAynNmFR1mNYJ5TNvM11rgDm9fYNvCosLNCOFWJMzCfHsTuBgATLphd2LlW2o0PKPN6lTeDnDo01g-
Ya3ko5ZwnXo9HAVifp69pQVpjFJlMCocQ
Response Summary:
Please fill out the information below:
Contact Person: Christian Boudreau
Company Name: Staker Parson
Mailing Address: 89 W 13490 S
City: Draper
Zip: 84020
Phone Number: 3853186938
Email: christian.boudreau@stakerparson.com
Is the site located within a PM2.5 non-attainment and maintenance plan areas on cleared land grea...
Yes
All temporary relocation projects are required to submit a Fugitive Dust Control Plan (FDCP). Lo...
E2B342FAEB
Briefly give directions to the site and/or physical address:
1730 N Beck St
Proposed Relocation Information:
Closest City Salt Lake City
County Salt Lake
UTM X Coordinates 12 0424799 E 4513409 N
UTM Y Coordinates 4513409 N
Approximate distance to the nearest house/business 1000 ft
UTM X Coordinates to nearest house/business 12 0422618 E
UTM Y Coordinates to nearest house/business 4518151 N
Does this site currently have a permit with DAQ?
1/10/24, 10:55 AM State of Utah Mail - Portable/Temporary Relocation Form
https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1787647152367629348%7Cmsg-f:1787647152367629348&…2/2
Yes
If yes, what is the Permit (DAQ-AN) # ?
DAQE-AN130990004-09
If yes, what is the Permit Holder's Name?
Staker Parson Companies
Please provide the permit ID for the equipment? (DAQE-XXXXXXXXX-XX)
DAQE-AN115180014-15
Please list all the Equipment on Site:Note: It is important to identify ALL diesel powered engine...
1
Equipment Type Cone Crusher
Serial or ID# II.A.6
2
Equipment Type Impact Crusher
Serial or ID# II.A.126
3
Equipment Type Screen
Serial or ID# II.A.174
4
Equipment Type Screen
Serial or ID# II.A.174
5
Equipment Type Generator
Serial or ID# II.A.762
Design Capacity 745 kW
Please attach a site diagram showing the equipment layout and general site dimensions for this re...
https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_2CNAmW2uAOzxqnw
Have any other state or local regulatory agencies issued any other "Conditional Use Permits" for...
No
Operational Information: (Please note: Operating time over 16 hours in a 24 hour period will re...
Total Hours of operation per 24 hr period 16
Starting time of operation (am/pm) 6 am
Ending time of operation (am/pm) 10 pm
Maximum hourly production rate for project 700 tph
Expected startup date 01/09/2024
Expected completion date 01/09/2024
What type of application is this for?
New Application
In accordance with the fee schedule approved by the Utah State Legislature, the Division of Air Q...
https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_3ltYIPxnPHfajnU
Owner/Operator Representative:
https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_8exsftPvIiKOO0F