Loading...
HomeMy WebLinkAboutDAQ-2024-0082321 DAQC-PBR147150001-24 Site ID 14715 (B1) MEMORANDUM TO: FILE – UINTA WAX OPERATING, LLC – Kendall State 14-4-3-1E-WS THROUGH: Rik Ombach, Minor Source Oil and Gas Compliance Section Manager FROM: Chris Jensen, Environmental Scientist DATE: May 28, 2024 SUBJECT: OIL AND GAS PERMIT-BY-RULE EVALUATION INSPECTION DATE: May 15, 2024 SOURCE LOCATION: Kendall State 14-4-3-1E-WS Lat:40.240315 Long: -109.886441 Business Office: 6000 Western Place, Suite 1000 Fort Worth, TX 76107-4664 SOURCE TYPE: Tank Battery Uintah County API: 4304753114 SOURCE CONTACTS: Aimee Cole, Local Contact Phone: 720-384-7365, Email: acole@finleyresources.com Kaitlin Meszaros, Corporate Environmental Contact Email: meszaros@pinyon-env.com Kaylene Bridwell, Corporate Environmental Contact Phone: 405-496-7308, Email: kaylene.bridwell@uintawax.com OPERATING STATUS: Operating PROCESS DESCRIPTION: Oil and gas products are brought to the surface. These products go through a separator where the oil and any water products are sent to storage tanks and the gas is used to power equipment on site (pump jack engine, tank heater, separator, flare, combustor, etc.) Any remaining gas is sent to a pipeline that feeds a local gas plant. The oil and process water in the storage tanks is loaded into tanker trucks and hauled off-site for processing and disposal. 2 APPLICABLE REGULATIONS: Utah Administrative Code (UAC) R307-500 Series for the Oil and Gas Industry, and UAC R307-201: Emission Standards: General Emission Standards; and UAC R307-150: Emission Inventories, and 40 CFR 60 Subpart JJJJ, 40 CFR 60 Subpart OOOO. SOURCE EVALUATION: Site Type: PBR- Controlled Controlled by flare Site powered by Engine DOGM current 12 month rolling production is: 5,660 BBLs. Utah Statute R307-506 requires a source with throughput greater than 8,000 BBLs to have controls. REGISTERED EQUIPMENT: Oil and Gas Industry Registration Requirement The source is registered with the DAQ. [R307-505-3(3)] In Compliance. Registration has been updated within 30 days of a company name change, removal or addition of control devices, or termination of operations. [R307-505-3(3)] In Compliance. Storage Vessels Records for each of the following are kept for three years: Storage vessel vent system inspections (openings, thief hatches, pressure relief devices, bypasses, etc.), if required Monthly crude oil throughput Emission calculations, actuals and sampling data when used to justify an exemption to storage vessel rules Emergency storage vessel usage (dates used, emptied, and volumes), if not controlled per R307-506-4(2). [R307-506-5] In Compliance. The recordkeeping procedures of the Operator, concerning these requirements, are found to be orderly and complete. The records were submitted by email. See attached. Natural Gas Engines Affected engines are certified or have an initial performance test per 40 CFR 60.4244. [R307-510-4(2)] In Compliance. This well was drilled before 2016 and the pumpjack engine is instead subject to the performance standards in NSPS (60) JJJJ. 3 Engine certifications or initial performance tests required are kept for the life of the engine at the source. [R307-510-5] In Compliance. Engines installed before 2016 are not under obligation to retain certifications or stack tests for life. Emission Inventory: An emissions inventory has been submitted within the past three years. [R307-150-9(1)] In Compliance. NSPS (Part 60) JJJJ: Standards of Performance for Stationary Spark Ignition Internal Combustion Engines. In Compliance. The engine at this source is not certified. Stack testing may or may not have been performed but, the record retention time limit for this testing has expired. The maintenance provisions have been met. NSPS (Part 60) OOOO: Standards of Performance for Crude Oil and Natural Gas Production, Transmission and Distribution [40 CFR 60 Subpart OOOO] In Compliance. The tank battery at this source no longer has the production to have the PTE in excess of 4 TPY and are no longer an affected facility under this subpart. There are no other affected facilities installed. PREVIOUS ENFORCEMENT ACTIONS: No enforcement actions within the past five years. COMPLIANCE STATUS & RECOMMENDATIONS: In regards to: Kendall State 14-4-3-1E-WS: In Compliance – Travel restrictions made access to the source physical location difficult. The DAQ only conducted a review of the rules requiring recordkeeping. RECOMMENDATION FOR NEXT INSPECTION: The DAQ has no Recommendations for the next inspector other than what are customary. The DAQ recommends the inspection frequency of this source remain as planned. ATTACHMENTS: Email Engine Service Checklist Report View Engine Service Checklist Report View Mon May 20 2024 12:09:29 PDT Reference Number Form Name Device Entry Time ServiceDate Facility EngineStatus MakeMod EngMake EngModel SerialCorrect SerialNumber ManufDateCorrect DateManufacture Power Band Air Filters Belts Carburetor Clutch Crank Case Engine Mounts Fuel System Grease Unit Grease Trace Grease Clutch Grease Fanhub GreaseJackShaft Hoses Leaks Lube Box Condition Oil & Filters Oil Level Regulator Radiator Reeds Safety Shutdowns Scavenger Port Spark Plug Wires Spark Plugs Starter Timing Trace System Unit Wiring Water Filters Wiring Condition 20221213- 18282658745 Engine Maintenance 2022-12-13T14:34:10- 07:00 12/09/2022 Kendall State 14-4-3-1E -WS Yes/No - Source?NA Cleaned Checked, Good Checked, Good Checked, Good Checked, Good Checked, Good Checked, Good No Yes Yes Yes Yes Checked, Good Checked, Good Checked, Good Checked, Good Checked, Good Checked, Replaced Checked, Good Checked, Good Checked, Replaced Checked, Replaced N/A Checked, Good Checked, Good Checked, Good N/A Checked, Good 20230825- 18327445200 Engine Maintenance 2023-08-25T08:32:41- 06:00 08/24/2023 Kendall State 14-4-3-1E -WS Running under load / Pumping Yes/No - Source?NA Cleaned Checked, Good Checked, Good Checked, Good Checked, Good Checked, Good Checked, Good No Yes Yes Yes Yes Checked, Good Checked, Good Checked, Good Checked, Good Checked, Good Checked, Replaced Checked, Good Checked, Good Checked, Replaced Checked, Replaced N/A Checked, Good Checked, Good Checked, Good N/A Checked, Good 20230526- 18311136941 Engine Maintenance 2023-05-26T08:33:14- 06:00 05/25/2023 Kendall State 14-4-3-1E -WS Running under load / Pumping Yes/No - Source?NA Cleaned Checked, Good Checked, Good Checked, Good Checked, Good Checked, Good Checked, Good No Yes Yes Yes Yes Checked, Good Checked, Good Checked, Good Checked, Good Checked, Good Checked, Replaced Checked, Good Checked, Good Checked, Replaced Checked, Replaced N/A Checked, Good Checked, Good Checked, Good N/A Checked, Good 20231222- 18348579778 Engine Maintenance 2023-12-22T07:55:11- 07:00 12/21/2023 Kendall State 14-4-3-1E -WS Running under load / Pumping Yes/No - Source?NA Cleaned Checked, Good Checked, Good Checked, Good Checked, Good Checked, Good Checked, Good No Yes Yes Yes Yes Checked, Good Checked, Good Checked, Good Checked, Good Checked, Good Checked, Replaced Checked, Good Checked, Good Checked, Replaced Checked, Replaced N/A Checked, Good Checked, Good Checked, Good N/A Checked, Good 20220825- 18264359193 Engine Maintenance 2022-08-25T09:48:36- 06:00 08/23/2022 Kendall State 14-4-3-1E -WS Yes/No - Source?NA Cleaned Checked, Good Checked, Good Checked, Good Checked, Good Checked, Good Checked, Good No Yes Yes Yes Checked, Good Checked, Good Checked, Good Checked, Good Checked, Good Checked, Replaced Checked, Good Checked, Good Checked, Replaced Checked, Replaced N/A Checked, Good Checked, Good Checked, Good N/A Checked, Good Page 1