DAQC-210-24
Site ID 13031 (B5)
MEMORANDUM
TO: FILE - PACIFICORP – Lake Side Plant
THROUGH: Harold Burge, Major Source Compliance Section Manager
FROM: Rob Leishman, Environmental Scientist
DATE: March 4, 2024
SUBJECT: PacifiCorp – Lake Side Plant (Lake Side), Major, Db, Dc, GG, NSPS, and Title V,
Utah County, FRS # UT00000049004900241
INSPECTION TYPE: State Electronic Data Report (SEDR) Review
REVIEW DATE: March 4, 2024
SOURCE LOCATION: Vineyard/Utah County
SOURCE CONTACT: Veronica Reyes - 801-796-1916
APPLICABLE
REGULATIONS: Title V Operating Permit No.: 4900241002
Issued: July 16, 2021
Last Revision: July 16, 2021
SOURCE INSPECTION
EVALUATION: Quarterly report memoranda will only address the findings of the
quarterly report. Approval Order and Title V permit conditions
addressing continuous emission monitoring requirements will be
addressed in Lake Side’s relative accuracy performance specification test
review memorandum.
SEDR Summary:
Fourth Quarter 2023
% Monitor Availability (MA) Performance Test Dates
(N/A to Opacity)
Summary of Excess Emissions During Point
Source Operation
Point
Source
Op.
hrs. Channel MA CGA Lin RATA Point
Source Channel Hrs. Limitation
CT01 2146 NOx 95% 11/07/23 05/18/23 CT01 NOx 0.00 2 ppmvd - 3
hour
CT01 2146 CO 95% 11/07/23 05/18/23 CT01 NOx 0.00 112 ppmvd - 4
hour
CT01 2146 O2 95% 11/07/23 05/18/23 CT01 NOx 0.00 14.9 lb/hr - 3
hour
1 8 2
2
Fourth Quarter 2023
% Monitor Availability (MA) Performance Test Dates
(N/A to Opacity)
Summary of Excess Emissions During Point
Source Operation
Point
Source
Op.
hrs. Channel MA CGA Lin RATA Point
Source Channel Hrs. Limitation
DB01 0 NOx
Point
source
not
operated
05/18/23 CT01 NOx 0.00
25 ppmvd -
short-term
excursions
CT02 1991 NOx 99% 11/08/23 05/19/23 DB01 NOx 0.00 0.2 lb/MMBTU
- 30 day
CT02 1991 CO 99% 11/08/23 05/19/23 CT01 CO 0.00 3 ppmvd - 3
hour
CT02 1991 O2 99% 11/08/23 05/19/23 CT01 CO 0.00 14.1 lb/hr - 3
hour
DB02 0 NOx 100% 11/08/23 05/19/23 CT01 CO 0.00
50 ppmvd -
short-term
excursions
CT03 1191 NOx 100% 11/17/23 05/16/23 CT02 NOx 0.00 2 ppmvd - 3
hour
CT03 1191 CO 100% 11/17/23 05/16/23 CT02 NOx 0.00 112 ppmvd - 4
hour
CT03 1191 O2 100% 11/17/23 05/16/23 CT02 NOx 0.00 14.9 lb/hr - 3
hour
CT04 1173 NOx 100% 11/15/23 05/17/23 CT02 NOx 0.00
25 ppmvd -
short-term
excursions
CT04 1173 CO 100% 11/15/23 05/17/23 DB02 NOx 0.00 0.2 lb/MMBTU
- 30 day
CT04 1173 O2 100% 11/15/23 05/17/23 CT02 CO 0.00 3 ppmvd - 3
hour
CT02 CO 0.00 14.1 lb/hr - 3
hour
CT02 CO 0.00
50 ppmvd -
short-term
excursions
CT03 NOx 0.00 2 ppmvd - 3
hour
CT03 NOx 0.00 15 ppmvd - 30
day
CT03 NOx 0.00 18.1 lb/hr - 3
hour
CT03 NOx 0.00
25 ppmvd -
short-term
excursions
CT03 NOx 0.00
130 lb/hr - 1
hour startup
shutdown
CT03 CO 3.00 3 ppmvd - 3
hour
CT03 CO 3.00 16.6 lb/hr - 3
hour
3
Fourth Quarter 2023
% Monitor Availability (MA) Performance Test Dates
(N/A to Opacity)
Summary of Excess Emissions During Point
Source Operation
Point
Source
Op.
hrs. Channel MA CGA Lin RATA Point
Source Channel Hrs. Limitation
CT03 CO 0.00
3000 lb/hr - 1
hour startup
shutdown
CT03 CO 0.00 950 lb/MW - 12
MRA
CT03 CO 0.00
50 ppmvd -
short-term
excursions
CT04 NOx 0.00 2 ppmvd - 3
hour
CT04 NOx 0.00 15 ppmvd - 30
day
CT04 NOx 0.00 18.1 lb/hr - 3
hour
CT04 NOx 0.00
25 ppmvd -
short-term
excursions
CT04 NOx 0.00
130 lb/hr - 1
hour startup
shutdown
CT04 CO 0.00 3 ppmvd - 3
hour
CT04 CO 0.00 16.6 lb/hr - 3
hour
CT04 CO 0.00
3000 lb/hr - 1
hour startup
shutdown
CT04 CO 0.00 950 lb/MW - 12
MRA
CT04 CO 0.00
50 ppmvd -
short-term
excursions
Excess Emission Report - Hourly Summary
Point
Source Channel
Startup
&
Shutdown
Control
Equipment
Problems
Process
Problems
Other
Known
Causes
Unknown
Causes
Emission
Limit
CT01 NOx 0 0 0 0 0 2 ppmvd - 3 hour
CT01 NOx 0 0 0 0 0 112 ppmvd - 4 hour
CT01 NOx 0 0 0 0 0 14.9 lb/hr - 3 hour
CT01 NOx 0 0 0 0 0 25 ppmvd - short-term excursions
DB01 NOx 0 0 0 0 0 0.2 lb/MMBTU - 30 day
CT01 CO 0 0 0 0 0 3 ppmvd - 3 hour
CT01 CO 0 0 0 0 0 14.1 lb/hr - 3 hour
4
Excess Emission Report - Hourly Summary
Point
Source Channel
Startup
&
Shutdown
Control
Equipment
Problems
Process
Problems
Other
Known
Causes
Unknown
Causes
Emission
Limit
CT01 CO 0 0 0 0 0 50 ppmvd - short-term excursions
CT02 NOx 0 0 0 0 0 2 ppmvd - 3 hour
CT02 NOx 0 0 0 0 0 112 ppmvd - 4 hour
CT02 NOx 0 0 0 0 0 14.9 lb/hr - 3 hour
CT02 NOx 0 0 0 0 0 25 ppmvd - short-term excursions
DB02 NOx 0 0 0 0 0 0.2 lb/MMBTU - 30 day
CT02 CO 0 0 0 0 0 3 ppmvd - 3 hour
CT02 CO 0 0 0 0 0 14.1 lb/hr - 3 hour
CT02 CO 0 0 0 0 0 50 ppmvd - short-term excursions
CT03 NOx 0 0 0 0 0 2 ppmvd - 3 hour
CT03 NOx 0 0 0 0 0 15 ppmvd - 30 day
CT03 NOx 0 0 0 0 0 18.1 lb/hr - 3 hour
CT03 NOx 0 0 0 0 0 25 ppmvd - short-term excursions
CT03 NOx 0 0 0 0 0 130 lb/hr - 1 hour startup shutdown
CT03 CO 0 0 0 3 0 3 ppmvd - 3 hour
CT03 CO 0 0 0 3 0 16.6 lb/hr - 3 hour
CT03 CO 0 0 0 0 0 3000 lb/hr - 1 hour startup shutdown
CT03 CO 0 0 0 0 0 950 lb/MW - 12 MRA
CT03 CO 0 0 0 0 0 50 ppmvd - short-term excursions
CT04 NOx 0 0 0 0 0 2 ppmvd - 3 hour
CT04 NOx 0 0 0 0 0 15 ppmvd - 30 day
CT04 NOx 0 0 0 0 0 18.1 lb/hr - 3 hour
CT04 NOx 0 0 0 0 0 25 ppmvd - short-term excursions
CT04 NOx 0 0 0 0 0 130 lb/hr - 1 hour startup shutdown
CT04 CO 0 0 0 0 0 3 ppmvd - 3 hour
CT04 CO 0 0 0 0 0 16.6 lb/hr - 3 hour
CT04 CO 0 0 0 0 0 3000 lb/hr - 1 hour startup shutdown
CT04 CO 0 0 0 0 0 950 lb/MW - 12 MRA
CT04 CO 0 0 0 0 0 50 ppmvd - short-term excursions
5
CMS Performance Summary - Hourly Summary
Point
Source Channel Monitor
Malfunction
Non-monitor
Malfunction
QA
Calibrations
Other
Known
Causes
Unknown
Causes
CT01 NOx 0 0 1 104 0
CT01 CO 0 0 0 100 0
CT01 O2 0 0 1 101 0
DB01 NOx 0 0 0 0 0
CT02 NOx 0 3 3 11 0
CT02 CO 0 2 3 12 0
CT02 O2 0 2 5 14 0
DB02 NOx 0 0 0 0 0
CT03 NOx 0 0 0 2 0
CT03 CO 0 0 0 2 0
CT03 O2 0 0 0 2 0
CT04 NOx 0 2 0 2 0
CT04 CO 0 2 0 2 0
CT04 O2 0 2 0 2 0
Pollutant Concentration
Exceeded Span of CEM
Monitor Outage During
Point Source Operation
Alternate
Sampling CEM Modifications
0 Hours 380 Hours 0 Hours 0 Events
DEVIATIONS: Periods of excess emissions that were recorded by the CMS in service on
each point source during this reporting period are summarized in the
SEDR and described in Pivot Table 400 “Excess Emissions Review.”
SUMMARY EVALUATION: Lake Side maintains its CEMS as required in R307-170 and 40 CFR
60.13.
RECOMMENDATIONS: All deviations appear to be a result of breakdown or process related
problems that do not warrant issuing a violation. Lake Side was in
compliance during this reporting period. No further enforcement actions
should be taken.
Lake Side’s NSPS monitoring system meets the performance standards
of 40 CFR 60, Appendix B Performance Specifications.
Lake Side’s acid rain monitoring system meets the performance
standards of 40 CFR 75 Acid Rain Performance Specifications.
HPV: No
6
RECOMMENDATION
FOR NEXT INSPECTION: Check DAS for daily zero and span drift.
Check the QC program to ensure that monitor drift is being tracked and
that the source can identify excessive drift.
ATTACHMENTS: Excel spreadsheet review
ROCKY MOUNTAIN
PolAIER
UTAH DEPARTMETIT OF
Lake Side power plant ENV|ROT,IMENTAL OUAL|TY
1825 North Pioneer Lane
Vineyard, UT 84042
January 30.2024
Mr. Bryce Bird, Director i)i\.'llilON OF AIR QUALITY
Utah Department of Environmental Quality
Division of Air Quality
P.O. Box 144820
Salt Lake city, utah 84114-4820
Dear Mr. Bird,
Re: USEPA Acid Rain Program Fourth Quarter 2023 Report for Lake Side Power Plant
The USEPA Acid Rain Program Fourth Quarter 2023 Federal Quarterly Report for PacifiCorp, Lake Side
Power Plant, ORIS Code 56237 for: CTOI, CT02, CT03 and CT04 was filed electronically. The following
table indicates the submittal dates and submission IDs:
Unit ID Date Submitted Quality Assurance
Submission ID
Em
Subm
sslons
ssion ID
Monitoring Plan
Submission ID
CTOl 712024 1647793 1647794 1647792
CT02 712024 1647799 1647800 NA
CTO3 712024 1647804 1647805 NA
CTO4 712024 1647809 t647810 NA
Enclosed is a CD with the submitted EDR.
Should you have any questions regarding this information, please contact Veronica Reyes, Lake Side Plant
Environmental Analyst, 801-796-1916 or Joshua Sewell, Environmental Engineer, PacifiCorp
Environmental Compliance Department, 80 I -220-20 I 0.
I certifu that all data submitted in this report were recorded in accordance with the applicable requirements
of 40 CFR Part75, and that all emission and quality control data are reported using component ID codes,
system ID codes, and formula ID codes which represent current operating conditions.
ROCKY MOUNTAIN
PO'I'ER
I am authorized to make this submission on behalf of the owners and operators of the affected source or
affected units for which the submission is made. I certiff under penalty of law that I have personally
examined, and am familiar with, the statements and information submitted in this document and all its
attachments. Based on my inqurry of those individuals with primary responsibility for obtaining the
information, I certifu that the statements and information are to the best of my knowledge and belief true,
accurate, and complete. I am aware that there are significant penalties for submitting false statements and
information, or omitting statements and information, including the possibility of fine or imprisonment.
Sincerelv.
,0k-)**
Dustian Weaver- Lake Side Plant Manager
Enclosures
cc: U.S. EPA Region VIII - (w/o CD)
Lake Side EER 4Q2023
Point Source Information Late Expired Cal. Gas Valid Cal. Gas Days Yes No
1 Type Code 100
(Company Information)Type Code Company Manager Company Name AIRS # Phone Number
Environmental
Contact
1 100 Dustian Weaver 04900241 801-796-1916 Veronica Reyes
1 100 0 . 0 0
1 Type Code 110
(Point Source Identification)Type Code Point Source
Quarter
1 - 4 Year
Point Source
Operating Hrs. in
Quarter
1 110 4 2023 2146.3
1 110 4 2023 1991.9
1 110 4 2023 1191.6
1 110 4 2023 1173.9
1 110 4 2023 0
1 110 4 2023 0.1
1 110 0 0 0
1 110 0 0 0
1 Type Code 200
(Monitor Identification)Type Code Point Source Channel Manufacturer Model No. Monitor SN Low Span High Span Installation Date
Monitor
Location
1 200 CO TECO 48i 611416457 10 3000 8/14/2007 Shelter
1 200 NOx TECO 42i 611416453 10 50 8/14/2007 Shelter
1 200 O2 Servomex 1440D 01440DIV02/37310 25 8/14/2007 Shelter
1 200 CO TECO 48i 611416458 10 3000 8/14/2007 Shelter
1 200 NOx TECO 42i 611416455 10 50 8/14/2007 Shelter
1 200 O2 Servomex 1440D 01440DIV02/37790 25 8/14/2007 Shelter
1 200 CO TECO 48i 1231355641 10 3000 4/29/2014 Shelter
1 200 NOx TECO 42i 1231355639 10 50 4/29/2014 Shelter
1 200 O2 Servomex 1440D 01440D1/4770 0 25 4/29/2014 Shelter
1 200 CO TECO 48i 1231355642 10 3000 4/29/2014 Shelter
1 200 NOx TECO 42i 1231355640 10 50 4/29/2014 Shelter
1 200 O2 Servomex 1440D 01440D1/4783 0 25 4/29/2014 Shelter
1 200 NOx TECO 42i 611416453 10 50 8/14/2007 Shelter
1 200 NOx TECO 42i 611416455 10 50 8/14/2007 Shelter
1 200 0 0 0 0 0 0 1/0/1900 0
1 200 0 0 0 0 0 0 1/0/1900 0
1
Type Code310
(Excess Emissions)
SUMMARY REPORT
Type Code Channel
Total Hours of Excess
Emissions
Excess Emissions -
% of Total
Operating Hours
RC 701 Hours -
start
up/Shutdown
RC 702 Hours-
Control Equipment
Problems
RC 703 Hours -
Process Problems
RC 704, 706, 707
Hours -Other Known
Causes
RC 705 Hours -
Unknown
Causes
Emission
Limitation
Emission
Limitation
Units
Emission
Limitation
Averaging
Period
1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 2 ppmvd 3 hour
1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 112 ppmvd 4 hour
1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 14.9 lb/hr 3 hour
1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 25 ppmvd short-term excursions
1 Point source not operated 310 NOx 0 0.00% 0 0 0 0 0 0.2 lb/MMBTU 30 day
1 TRUE 310 CO 0 0.00% 0 0 0 0 0 3 ppmvd 3 hour
1 TRUE 310 CO 0 0.00% 0 0 0 0 0 14.1 lb/hr 3 hour
1 TRUE 310 CO 0 0.00% 0 0 0 0 0 50 ppmvd short-term excursions
1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 2 ppmvd 3 hour
1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 112 ppmvd 4 hour
1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 14.9 lb/hr 3 hour
1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 25 ppmvd short-term excursions
1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 0.2 lb/MMBTU 30 day
1 TRUE 310 CO 0 0.00% 0 0 0 0 0 3 ppmvd 3 hour
1 TRUE 310 CO 0 0.00% 0 0 0 0 0 14.1 lb/hr 3 hour
1 TRUE 310 CO 0 0.00% 0 0 0 0 0 50 ppmvd short-term excursions
1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 2 ppmvd 3 hour
1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 15 ppmvd 30 day
1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 18.1 lb/hr 3 hour
1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 25 ppmvd short-term excursions
1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 130 lb/hr 1 hour startup shutdown
1 TRUE 310 CO 3 0.25% 0 0 0 3 0 3 ppmvd 3 hour
1 TRUE 310 CO 3 0.25% 0 0 0 3 0 16.6 lb/hr 3 hour
1 TRUE 310 CO 0 0.00% 0 0 0 0 0 3000 lb/hr 1 hour startup shutdown
1 TRUE 310 CO 0 0.00% 0 0 0 0 0 950 lb/MW 12 MRA
1 TRUE 310 CO 0 0.00% 0 0 0 0 0 50 ppmvd short-term excursions
1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 2 ppmvd 3 hour
1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 15 ppmvd 30 day
1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 18.1 lb/hr 3 hour
1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 25 ppmvd short-term excursions
1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 130 lb/hr 1 hour startup shutdown
1 TRUE 310 CO 0 0.00% 0 0 0 0 0 3 ppmvd 3 hour
1 TRUE 310 CO 0 0.00% 0 0 0 0 0 16.6 lb/hr 3 hour
1 TRUE 310 CO 0 0.00% 0 0 0 0 0 3000 lb/hr 1 hour startup shutdown
1 TRUE 310 CO 0 0.00% 0 0 0 0 0 950 lb/MW 12 MRA
1 TRUE 310 CO 0 0.00% 0 0 0 0 0 50 ppmvd short-term excursions
1 310 0 0 0 0 0 0 0 0 0
1 310 0 0 0 0 0 0 0 0 0
Point Source
CT01
CT02
CT03
CT04
DB01
DB02
0
0
CT01
CT01
DB01
CT02
CT02
CT04
CT04
CT04
0
0
CT04
CT04
DB01
DB02
0
0
PacifiCorp Lake Side Power Plant
0
CT01
CT01
CT01
CT02
CT02
CT02
CT03
CT03
CT03
CT04
CT04
CT04
CT04
CT01
CT01
CT01
CT02
CT02
CT01
CT01
DB02
CT02
CT02
CT02
CT03
CT03
CT03
CT03
CT03
CT03
CT03
CT03
CT03
CT03
CT04
CT04
CT04
CT04
Lake Side EER 4Q2023
1 Type Code 300 (CMS
Performance Summary) Type Code Channel
Point Source Operating
Hours
Downtime - % of
Total Operating
Hours
Total CMS
Downtime
RC 721 Hours -
Monitor
Malfunction
RC 722 Hours -
Non-monitor
Malfunction
RC 723 Hours -
QA Calibrations
RC 724 Hours -
Other Known
Causes
RC 725
Hours -
Unknown
Causes
1 TRUE 300 NOx 2146.3 4.91% 105.4 0 0 1.1 104.3 0
1 TRUE 300 CO 2146.3 4.65% 99.9 0 0 0.3 99.6 0
1 TRUE 300 O2 2146.3 4.75% 102 0 0 1.1 100.9 0
1 Point source not operated 300 NOx 0 0.00% 0 0 0 0 0 0
1 TRUE 300 NOx 1991.9 0.87% 17.3 0 2.7 3.2 11.4 0
1 TRUE 300 CO 1991.9 0.86% 17.1 0 1.5 3.2 12.4 0
1 TRUE 300 O2 1991.9 1.06% 21.2 0 1.5 5.3 14.4 0
1 TRUE 300 NOx 0.1 0.00% 0 0 0 0 0 0
1 TRUE 300 NOx 1191.6 0.19% 2.3 0 0 0 2.3 0
1 TRUE 300 CO 1191.6 0.19% 2.3 0 0 0 2.3 0
1 TRUE 300 O2 1191.6 0.19% 2.3 0 0 0 2.3 0
1 TRUE 300 NOx 1173.9 0.33% 3.9 0 2.1 0 1.8 0
1 TRUE 300 CO 1173.9 0.33% 3.9 0 2.1 0 1.8 0
1 TRUE 300 O2 1173.9 0.33% 3.9 0 2.1 0 1.8 0
1 300 0 0 0 0 0 0
1 300 0 0 0 0 0 0
1
Type Code 250
(Performance Specification
RATA Results)
Type Code Channel
Date of Most Current
RATA
Date of Preceding
RATA
Months Between
RATA's
Units of
Measurement CEM Value Reference Method
Value
Relative
accuracy Pass/ Fail
1 378 Days 250 NOx 05/18/23 05/05/22 12.4 ppm@15O2 1.8 1.8 2.10% pass
1 378 Days 250 NOx 05/18/23 05/05/22 12.4 #/MMBtu, O2dil. 0.007 0.007 0.00% pass
1 378 Days 250 O2 05/18/23 05/05/22 12.4 Percent 13.4 13.5 0.80% pass
1 378 Days 250 CO 05/18/23 05/05/22 12.4 ppm@15O2 0.3 0.4 10.00% pass
1 378 Days 250 NOx 05/18/23 05/05/22 12.4 ppm@15O2 1.8 1.8 2.10% pass
1 378 Days 250 NOx 05/18/23 05/05/22 12.4 #/MMBtu, O2dil. 0.007 0.007 0.00% pass
1 380 Days 250 NOx 05/19/23 05/04/22 12.5 ppm@15O2 1.8 1.8 3.90% pass
1 380 Days 250 NOx 05/19/23 05/04/22 12.5 #/MMBtu, O2dil. 0.007 0.007 0.00% pass
1 380 Days 250 O2 05/19/23 05/04/22 12.5 Percent 13.4 13.4 0.60% pass
1 380 Days 250 CO 05/19/23 05/04/22 12.5 ppm@15O2 1.3 1.4 10.00% pass
1 380 Days 250 NOx 05/19/23 05/04/22 12.5 ppm@15O2 1.8 1.8 3.90% pass
1 380 Days 250 NOx 05/19/23 05/04/22 12.5 #/MMBtu, O2dil. 0.007 0.007 0.00% pass
1 379 Days 250 NOx 05/16/23 05/02/22 12.5 ppm@15O2 1.7 1.7 5.10% pass
1 379 Days 250 NOx 05/16/23 05/02/22 12.5 #/MMBtu, O2dil. 0.006 0.006 0.00% pass
1 379 Days 250 O2 05/16/23 05/02/22 12.5 Percent 12 12.1 2.20% pass
1 379 Days 250 CO 05/16/23 05/02/22 12.5 ppm@15O2 0 0.1 10.00% pass
1 379 Days 250 NOx 05/17/23 05/03/22 12.5 ppm@15O2 1.7 1.6 5.20% pass
1 379 Days 250 NOx 05/17/23 05/03/22 12.5 #/MMBtu, O2dil. 0.006 0.006 0.00% pass
1 379 Days 250 O2 05/17/23 05/03/22 12.5 Percent 12.1 12.2 1.20% pass
1 379 Days 250 CO 05/17/23 05/03/22 12.5 ppm@15O2 0.1 0.1 0.00% pass
1 0 Days 250 0 01/00/00 01/00/00 0 0 0 0 0.00% 0
1 0 Days 250 0 01/00/00 01/00/00 0 0 0 0 0.00% 0
1 Type Code 260
(CGA Results)Type Code Channel Date Audit Point No. Cylinder ID
Cylinder
Expiration Date
Type of
Certification
Units of
Measurement CEM Value Cylinder
Value
Precision
%Pass/ Fail Range - High or
Low
1 Valid Cal. Gas 260 CO 11/07/23 Low EB0141740 04/21/24 P1 ppm 2.7 2.5 11.30% PASS Low
1 Valid Cal. Gas 260 CO 11/07/23 Mid EB0097216 03/08/24 P1 ppm 5.6 5.4 4.40% PASS Low
1 Valid Cal. Gas 260 CO 11/07/23 Low ALM048465 03/01/29 P1 ppm 735.9 748.5 -1.70% PASS High
1 Valid Cal. Gas 260 CO 11/07/23 Mid CC416517 03/01/29 P1 ppm 1655.6 1659 -0.20% PASS High
1 Valid Cal. Gas 260 CO 11/08/23 Low EB0141740 04/21/24 P1 ppm 1.7 2.5 -30.80% PASS Low
1 Valid Cal. Gas 260 CO 11/08/23 High EB0097216 03/08/24 P1 ppm 4.7 5.4 -13.50% PASS Low
1 Valid Cal. Gas 260 CO 11/08/23 Low ALM065527 03/01/29 P1 ppm 805.5 750.9 7.30% PASS High
1 Valid Cal. Gas 260 CO 11/08/23 High ALM029131 03/01/29 P1 ppm 1643.6 1653 -0.60% PASS High
1 Valid Cal. Gas 260 CO 11/17/23 Low EB141745 04/21/24 P1 ppm 2.7 2.45 8.80% PASS Low
1 Valid Cal. Gas 260 CO 11/17/23 High EB0134155 03/08/24 P1 ppm 5.5 5.4 2.20% PASS Low
1 Valid Cal. Gas 260 CO 11/17/23 Low ALM061648 03/01/29 P1 ppm 729.4 748.3 -2.50% PASS High
1 Valid Cal. Gas 260 CO 11/17/23 High CC741799 03/01/29 P1 ppm 1569.2 1676 -6.40% PASS High
1 Valid Cal. Gas 260 CO 11/15/23 Low EB0141915 04/21/24 P1 ppm 2.7 2.451 11.50% PASS Low
1 Valid Cal. Gas 260 CO 11/15/23 High EB0095857 03/08/24 P1 ppm 5.7 5.39 5.10% PASS Low
1 Valid Cal. Gas 260 CO 11/15/23 Low CC165866 03/01/29 P1 ppm 814.6 746.5 9.10% PASS High
1 Valid Cal. Gas 260 CO 11/15/23 High CC278204 3/1/29 P1 ppm 1,761 1,631 0 PASS High
1 260 0 1/0/00 0 0 1/0/00 0 0 0 0 0 0 0
1 260 0 1/0/00 0 0 1/0/00 0 0 0 0 0 0 0
Point Source
Point Source
Point Source
CT03
CT03
CT03
CT04
CT04
0
0
CT03
CT02
CT02
CT02
CT02
DB02
0
CT01
CT01
CT04
DB01
CT02
CT02
CT02
DB02
CT01
CT01
CT01
CT04
CT03
CT03
CT03
CT04
CT04
0
0
CT01
CT01
CT01
DB01
DB01
CT01
CT04
CT04
CT04
0
DB02
CT03
CT03
CT03
CT01
CT01
CT04
CT02
CT02
CT02
CT02
CT03
CT04
Lake Side EER 4Q2023
1 Type Code 270
(Linearity Test Results)Type Code Channel Date Audit Point No. Cylinder ID
Cylinder
Expiration Date
Type of
Certification
Units of
Measurement CEM Value Cylinder
Value
Precision
%Pass/ Fail Range - High or
Low
1 Valid Cal. Gas 270 NOx 11/07/23 Low EB0141740 04/21/24 P1 ppm 12.4 12.72 2.50% PASS High
1 Valid Cal. Gas 270 NOx 11/07/23 Mid EB0097216 03/08/24 P1 ppm 27.1 27.28 0.70% PASS High
1 Valid Cal. Gas 270 NOx 11/07/23 High CC340230 05/16/26 P1 ppm 45.4 45.24 0.40% PASS High
1 Valid Cal. Gas 270 O2 11/07/23 Low ALM048465 03/01/29 P1 Percent 6.1 6.267 3% PASS High
1 Valid Cal. Gas 270 O2 11/07/23 Mid CC416517 03/01/29 P1 Percent 13.6 13.79 1% PASS High
1 Valid Cal. Gas 270 O2 11/07/23 High ALM066447 06/30/30 P1 Percent 22.3 22.47 1% PASS High
1 Valid Cal. Gas 270 NOx 11/08/23 Low EB0141740 04/21/24 P1 ppm 12.5 12.72 1.70% PASS High
1 Valid Cal. Gas 270 NOx 11/08/23 Mid EB0097216 03/08/24 P1 ppm 27.2 27.28 0.30% PASS High
1 Valid Cal. Gas 270 NOx 11/08/23 High CC426905 01/04/26 P1 ppm 45.4 45.25 0.40% PASS High
1 Valid Cal. Gas 270 O2 11/08/23 Low ALM065527 03/01/29 P1 Percent 6.2 6.256 0.90% PASS High
1 Valid Cal. Gas 270 O2 11/08/23 Mid ALM029131 03/01/29 P1 Percent 13.7 13.83 0.70% PASS High
1 Valid Cal. Gas 270 O2 11/08/23 High ALM036368 07/31/31 P1 Percent 22.3 22.41 0.50% PASS High
1 Valid Cal. Gas 270 NOx 11/17/23 Low EB141745 04/21/24 P1 ppm 11.9 12.72 6.70% PASS High
1 Valid Cal. Gas 270 NOx 11/17/23 Mid EB0134155 03/08/24 P1 ppm 26.1 26.79 2.60% PASS High
1 Valid Cal. Gas 270 NOx 11/17/23 High CC419060 05/16/26 P1 ppm 45.6 45.59 0.10% PASS High
1 Valid Cal. Gas 270 O2 11/17/23 Low ALM061648 03/01/29 P1 Percent 6 6.272 4% PASS High
1 Valid Cal. Gas 270 O2 11/17/23 Mid CC741799 03/01/29 P1 Percent 13.2 13.84 4% PASS High
1 Valid Cal. Gas 270 O2 11/17/23 High EB0157342 07/31/31 P1 Percent 21.9 22.42 2% PASS High
1 Valid Cal. Gas 270 NOx 11/15/23 Low EB0141915 04/21/24 P1 ppm 12.2 12.75 4.30% PASS High
1 Valid Cal. Gas 270 NOx 11/15/23 Mid EB0095857 03/08/24 P1 ppm 26.5 27.1 2.20% PASS High
1 Valid Cal. Gas 270 NOx 11/15/23 High CC743650 10/24/25 P1 ppm 44.3 45.28 2.20% PASS High
1 Valid Cal. Gas 270 O2 11/15/23 Low CC165866 03/01/29 P1 Percent 6.3 6.28 0.30% PASS High
1 Valid Cal. Gas 270 O2 11/15/23 Mid CC278204 03/01/29 P1 Percent 13.8 13.9 0.70% PASS High
1 Valid Cal. Gas 270 O2 11/15/23 High CC401506 06/06/31 P1 Percent 22.3 22.48 0.80% PASS High
1 Valid Cal. Gas 270 NOx 11/07/23 Low EB0141740 04/21/24 P1 ppm 12.4 12.72 2.50% PASS High
1 Valid Cal. Gas 270 NOx 11/07/23 Mid EB0097216 03/08/24 P1 ppm 27.1 27.28 0.70% PASS High
1 Valid Cal. Gas 270 NOx 11/07/23 High CC340230 05/16/26 P1 ppm 45.4 45.24 0.40% PASS High
1 Valid Cal. Gas 270 NOx 11/08/23 Low EB0141740 04/21/24 P1 ppm 12.5 12.72 1.70% PASS High
1 Valid Cal. Gas 270 NOx 11/08/23 Mid EB0097216 03/08/24 P1 ppm 27.2 27.28 0.30% PASS High
1 Valid Cal. Gas 270 NOx 11/08/23 High CC426905 01/04/26 P1 ppm 45.4 45.25 0.40% PASS High
1 270 0 01/00/00 0 0 01/00/00 0 0 0 0 0.00% 0 0
1 270 0 01/00/00 0 0 01/00/00 0 0 0 0 0.00% 0 0
1
Type Code 210
(Pollutant Concentration
Exceeded Span of CEM)
Type Code Channel Start Date Start Time End Date End Time Hours
1 0 210 0 1/0/00 0:00 1/0/00 0:00
1
1 None Reported
1 0 TC 220 Hours 379.58 TC 220 Hours 0.00 TC 230 Hours 0.00 Events 0.00 Hours 0.00 Events 0.00 0.00
1 381.50 TC 300 Hours 1.92 FALSE
None Reported None Reported None Reported None Reported None Reported None Reported
CT03
CT03
CT03
CT04
CT04
CT04
CT04
DB01
DB01
DB01
DB02
DB02
DB02
0
0
Point Source
Point Source
Yes
Type Code 550
(Changes in Operation in
Control Equipment When
CEM Data Not Available)
Type Code 500
(Boiler Operating Days
w/o 18 Hours of Data)
Type Code 450
(Data Excluded)
Type Code 210
(Pollutant Concentration
Exceeded Span of CEM)
Type Code 220
(Monitor Outage
During Point Source Operation)
Type Code 230
(Manual Sample - Alternate
Sampling During Monitor
Outage)
Type Code 240
(CEM Modifications)
Type Code 530
(Excess Emissions During
Emergency Conditions)
CT03
CT04
CT04
CT01
CT02
CT02
CT02
CT02
CT01
CT01
CT01
CT01
CT01
CT03
CT03
CT02
CT02
0
Lake Side EER 4Q2023
Relative Accuracy Overview
Point Source Channel
Date of Most
Current
RATA
Date of
Preceding
RATA
Months Between
RATA's
Units
Measured CEM Value Reference Method
Value
Relative
Accuracy Pass/ Fail 2023
CT01 NOx 05/18/23 05/05/22 12.4 ppm@15O2 1.8 1.80 2.10% pass
CT01 NOx 05/18/23 05/05/22 12.4 #/MMBtu, O2dil. 0.007 0.01 0.00% pass
CT01 O2 05/18/23 05/05/22 12.4 Percent 13.4 13.50 0.80% pass
CT01 CO 05/18/23 05/05/22 12.4 ppm@15O2 0.3 0.40 10.00% pass
DB01 NOx 05/18/23 05/05/22 12.4 ppm@15O2 1.8 1.80 2.10% pass
DB01 NOx 05/18/23 05/05/22 12.4 #/MMBtu, O2dil. 0.007 0.01 0.00% pass
CT02 NOx 05/19/23 05/04/22 12.5 ppm@15O2 1.8 1.80 3.90% pass
CT02 NOx 05/19/23 05/04/22 12.5 #/MMBtu, O2dil. 0.007 0.01 0.00% pass
CT02 O2 05/19/23 05/04/22 12.5 Percent 13.4 13.40 0.60% pass
CT02 CO 05/19/23 05/04/22 12.5 ppm@15O2 1.3 1.40 10.00% pass
DB02 NOx 05/19/23 05/04/22 12.5 ppm@15O2 1.8 1.80 3.90% pass
DB02 NOx 05/19/23 05/04/22 12.5 #/MMBtu, O2dil. 0.007 0.01 0.00% pass
CT03 NOx 05/16/23 05/02/22 12.5 ppm@15O2 1.7 1.70 5.10% pass
CT03 NOx 05/16/23 05/02/22 12.5 #/MMBtu, O2dil. 0.006 0.01 0.00% pass
CT03 O2 05/16/23 05/02/22 12.5 Percent 12 12.10 2.20% pass
CT03 CO 05/16/23 05/02/22 12.5 ppm@15O2 0 0.10 10.00% pass
CT04 NOx 05/17/23 05/03/22 12.5 ppm@15O2 1.7 1.60 5.20% pass
CT04 NOx 05/17/23 05/03/22 12.5 #/MMBtu, O2dil. 0.006 0.01 0.00% pass
CT04 O2 05/17/23 05/03/22 12.5 Percent 12.1 12.20 1.20% pass
CT04 CO 05/17/23 05/03/22 12.5 ppm@15O2 0.1 0.10 0.00% pass
*
NSPS CGA Fourth 2023
Audit Gas Ranges Audit Gas Ranges
AP1 Low AP2 Low AP1 High AP2 High
CT01 CO 11/7/23 10 2.5 2 to 3
CT01 CO 11/7/23 10 5.4 5 to 6
CT01 CO 11/7/23 3000 748.5 600 to 900
CT01 CO 11/7/23 3000 1659 1500 to 1800
CT02 CO 11/8/23 10 2.5 2 to 3
CT02 CO 11/8/23 10 5.4 5 to 6
CT02 CO 11/8/23 3000 750.9 600 to 900
CT02 CO 11/8/23 3000 1653 1500 to 1800
CT03 CO 11/17/23 10 2.45 2 to 3
CT03 CO 11/17/23 10 5.4 5 to 6
CT03 CO 11/17/23 3000 748.3 600 to 900
CT03 CO 11/17/23 3000 1676 1500 to 1800
CT04 CO 11/15/23 10 2.451 2 to 3
CT04 CO 11/15/23 10 5.39 5 to 6
CT04 CO 11/15/23 3000 746.5 600 to 900
CT04 CO 11/15/23 3000 1631 1500 to 1800
*
Acid Rain Audit Linearity Fourth 2023
Low Span Gas Ranges High Span Gas Ranges
Low Mid High Low Mid High
CT01 NOx 11/7/23 50 12.72 10 to 15
CT01 NOx 11/7/23 50 27.28 25 to 30
CT01 NOx 11/7/23 50 45.24 40 to 50
CT01 O2 11/7/23 25 6.267 5 to 7.5
CT01 O2 11/7/23 25 13.79 12.5 to 15
CT01 O2 11/7/23 25 22.47 20 to 25
CT02 NOx 11/8/23 50 12.72 10 to 15
CT02 NOx 11/8/23 50 27.28 25 to 30
CT02 NOx 11/8/23 50 45.25 40 to 50
CT02 O2 11/8/23 25 6.256 5 to 7.5
CT02 O2 11/8/23 25 13.83 12.5 to 15
CT02 O2 11/8/23 25 22.41 20 to 25
CT03 NOx 11/17/23 50 12.72 10 to 15
CT03 NOx 11/17/23 50 26.79 25 to 30
CT03 NOx 11/17/23 50 45.59 40 to 50
CT03 O2 11/17/23 25 6.272 5 to 7.5
CT03 O2 11/17/23 25 13.84 12.5 to 15
CT03 O2 11/17/23 25 22.42 20 to 25
CT04 NOx 11/15/23 50 12.75 10 to 15
CT04 NOx 11/15/23 50 27.1 25 to 30
CT04 NOx 11/15/23 50 45.28 40 to 50
CT04 O2 11/15/23 25 6.28 5 to 7.5
CT04 O2 11/15/23 25 13.9 12.5 to 15
CT04 O2 11/15/23 25 22.48 20 to 25
DB01 NOx 11/7/23 50 12.72 10 to 15
DB01 NOx 11/7/23 50 27.28 25 to 30
DB01 NOx 11/7/23 50 45.24 40 to 50
DB02 NOx 11/8/23 50 12.72 10 to 15
DB02 NOx 11/8/23 50 27.28 25 to 30
DB02 NOx 11/8/23 50 45.25 40 to 50
Audit Gas Used
Point Source Channel Audit Date Low Span
Point Source Channel Audit Date Low Span
Audit Gas Used High Span Audit Gas Used
High SpanAudit Gas Used
Lake Side EER 4Q2023
Monitoring Information TC 210, 230, & 240
Type Code 210
(Pollutant Concentration Exceeded Span of CEM) - 500 (All)
*
Sum of Hours Column Labels
Row Labels (blank) Grand Total
(blank)0 0
Grand Total 0 0
*
Type Code 230
(Manual Sample - Alternate Sampling During Monitor Outage) - 500 (All)
*
Sum of Hours Column Labels
Row Labels (blank) Grand Total
(blank)0 0
Grand Total 0 0
*
Type Code 240
(CEM Modifications) - 100 (All)
*
Count of Channel Column Labels
Row Labels (blank) Grand Total
(blank)
(blank)
Grand Total
Lake Side EER 4Q2023
Type Code 220
(Monitor Outage During Point Source Operation) - 600 (All)
*
Sum of Hours Column Labels
Row Labels 724 723 722 Grand Total
CT02
O2
The monitoring system was placed in maintenance mode for general
maintenance and was returned to service after calibration.
0.58 0.58
The monitoring system was out of service for attempted CEMS
equipment replacement, but was returned to service after reinstalling
all original equipment.
13.83 13.83
QA/QC maintenance performed in preparation for and performance of
linearity-CGA testing.5.25 5.25
The monitoring system was placed in maintenance to replace Nox
vacuum pump, and was returned to service after performing a
calibration and abbreviated linearity.
1.48 1.48
NOx
The monitoring system was out of service for attempted CEMS
equipment replacement, but was returned to service after reinstalling
all original equipment.
11.37 11.37
QA/QC maintenance performed in preparation for and performance of
linearity-CGA testing.3.23 3.23
The monitoring system was placed in maintenance to replace Nox
vacuum pump, and was returned to service after performing a
calibration and abbreviated linearity.
2.68 2.68
CO
The monitoring system was out of service for attempted CEMS
equipment replacement, but was returned to service after reinstalling
all original equipment.
12.40 12.40
QA/QC maintenance performed in preparation for and performance of
linearity-CGA testing.3.23 3.23
The monitoring system was placed in maintenance to replace Nox
vacuum pump, and was returned to service after performing a
calibration and abbreviated linearity.
1.47 1.47
CT01
O2
The monitoring system was out of service for attempted CEMS
equipment replacement, but was returned to service after reinstalling
all original equipment.
96.23 96.23
The monitoring system was placed is maintenance to perform a cycle
response time test on a temporary like-kind NOx analyzer before
replacing with the original NOx analyzer.
1.45 1.45
The monitoring system was placed is maintenance to replace
permanent NOx analyzer.1.17 1.17
The monitoring system was placed is maintenance to perform a cycle
response time test on the original NOx analyzer.2.03 2.03
The unit shut down before calibration ended and did not have 2 valid
minutes separated by 15 minutes during the hour. 0.32 0.32
NOx
The monitoring system was out of service for attempted CEMS
equipment replacement, but was returned to service after reinstalling
all original equipment.
96.20 96.20
The monitoring system was placed is maintenance to perform a cycle
response time test on a temporary like-kind NOx analyzer before
replacing with the original NOx analyzer.
6.07 6.07
The monitoring system was placed is maintenance to perform a cycle
response time test on the original NOx analyzer.2.02 2.02
The unit shut down before calibration ended and did not have 2 valid
minutes separated by 15 minutes during the hour. 0.32 0.32
CO
The monitoring system was out of service for attempted CEMS
equipment replacement, but was returned to service after reinstalling
all original equipment.
96.20 96.20
The monitoring system was placed is maintenance to perform a cycle
response time test on a temporary like-kind NOx analyzer before
replacing with the original NOx analyzer.
1.42 1.42
The monitoring system was placed is maintenance to perform a cycle
response time test on the original NOx analyzer.2.02 2.02
The unit shut down before calibration ended and did not have 2 valid
minutes separated by 15 minutes during the hour. 0.32 0.32
CT04
O2
The monitoring system was placed is maintenance to perform a cycle
response time test on the original NOx analyzer.1.77 1.77
The monitoring system was placed in maintenance to troubleshoot
irratic CO readings, and was shutdown for repairs to a natural gas
vent.
2.05 2.05
NOx
The monitoring system was placed is maintenance to perform a cycle
response time test on the original NOx analyzer.1.77 1.77
The monitoring system was placed in maintenance to troubleshoot
irratic CO readings, and was shutdown for repairs to a natural gas
vent.
2.05 2.05
CO
The monitoring system was placed is maintenance to perform a cycle
response time test on the original NOx analyzer.1.77 1.77
The monitoring system was placed in maintenance to troubleshoot
irratic CO readings, and was shutdown for repairs to a natural gas
vent.
2.05 2.05
CT03
O2
The monitoring system was placed in maintenance mode for general
maintenance and was returned to service after calibration.
1.00 1.00
The monitoring system was placed is maintenance to perform a cycle
response time test on the original NOx analyzer.1.28 1.28
NOx
The monitoring system was placed in maintenance mode for general
maintenance and was returned to service after calibration.
1.00 1.00
The monitoring system was placed is maintenance to perform a cycle
response time test on the original NOx analyzer.1.28 1.28
CO
The monitoring system was placed in maintenance mode for general
maintenance and was returned to service after calibration.
1.00 1.00
The monitoring system was placed is maintenance to perform a cycle
response time test on the original NOx analyzer.1.28 1.28
Grand Total 355.13 12.67 11.78 379.58
Lake Side EER 4Q2023
NOx *
NOx Type Code 420 (NOx) - 6000 (All)
NOx *
NOx Count of Magnitude of Emissions Column Labels
NOx Row Labels Grand Total
NOx Grand Total
NOx d *
NOx d Type Code 421 (Daily NOx Emissions) - 500 (All)
NOx d *
NOx d Count of Reason Code Column Labels
NOx d Row Labels Grand Total
NOx d Grand Total
CO *
CO Type Code 440
(CO) - 6000 (All)
CO *
CO Count of Magnitude of Emissions Column Labels
CO Row Labels 704 Grand Total
CO CT03
CO A natural gas vent valve failed and opened, creating oxygen rich
burn, and resulting in CO instability.1 1
CO Grand Total 1 1
O2 *
O2 Type Code 470
(TRS as O2) - 6000 (All)
O2 *
O2 Count of Magnitude of Emissions Column Labels
O2 Row Labels Grand Total
O2 Grand Total
Lake Side EER 4Q2023
Type Code 500
Before February 28, 2005 (Boiler Operating Days w/o 18 Hours of
Data) After February 28, 2005 (90% Operating Hours For each 30 BOD)
- 500
(All)
*
Count of Channel Column Labels
Row Labels Grand Total
Grand Total
*
Type Code 510
(F-factor, Equations & Conversion Factors) - 500 (All)
Count of F-factor Column Labels
Row Labels Grand Total
Grand Total
*
Type Code 520
(Minimum Data Not
Obtained <22/30 BODs) - 500
(All)
Count of Channel Column Labels
Row Labels Grand Total
Grand Total
*
Type Code 530
(Excess Emissions During Emergency Conditions) - 500 (All)
Count of Date Column Labels
Row Labels Grand Total
Grand Total
*
Type Code 540
(Fuel Pre-treatment Credit SO2) - 500 (All)
Count of Date Column Labels
Row Labels Grand Total
Grand Total
*
TypeCode 550
(Changes in Operation in Control Equipment When CEM Data Not
Available) - 500
(All)
Column Labels
Row Labels Grand Total
Grand Total