Loading...
HomeMy WebLinkAboutDAQ-2024-007336January 3, 2023 Minor Source Compliance Section Utah Division of Air Quality Attn: Chad Gilgen P.O. Box 144820 Salt Lake City Utah 84114-4820 Dear Mr. Gilgen, The New Source Performance Standards for Small Industrial-Commercial-institutional Steam Generating Units (NSPS Boilers) 40 CFR 60 Subpart Dc reporting the quantity of fuel other than natural gas combusted during the reporting period for St. George Hospital Utah DAQ Site ID 12960. -Six month reporting period covered under this is from July 1, through December 31, 2023. -The 4-duel fuel boiler had a total of 12 hours of operation on diesel fuel for the reporting period. -A copy of the most recent diesel fuel analysis report is included as reference. In accordance with Utah Administrative Code R307-415-5d and based on information and belief formed after reasonable inquiry, I certify that the statements and information in this document are true, accurate, and complete. Sincerely, Jim Blankenau, P.G. Environmental Engineer Intermountain Health, Canyons 383 W. Vine Street (4th floor), Murray, UT 84124 801-484-6114 James.Blankenau@imail.org Attachments: St. George Fuel Analysis Report Initials: CG Date: 4-11-24 Compliance Status: In compliance - Subpart Dc Semi-Annual Notification File # 12960 (B2) Fuel Analysis Report North America:+1-877-808-3750 Based on ASTM D975 Standard Specification for Diesel Fuel. Decision rule based on simple acceptance. Account Information Account Number:ONLINE-2622-0000 Company Name:ST GEORGE REGIONAL HOSPITAL Contact:ALAN ROBERTS Address:1380 E. MEDICAL CENTER DR. ST.GEORGE, UT 84790 US Phone Number:435-703-0245 Component Information Component ID:FOT-1 423159 DF Secondary ID: Fuel Type:DIESEL FUEL Manufacturer: Model: Application:UNKNOWN Tank Capacity: Sample Information Tracking Number:23111M61733 Lab Number:S-978268 Lab Location:Salt Lake City Data Analyst:JUK Sampled:02-May-2023 Received:04-May-2023 Completed:15-May-2023 Filter Information Filter Change:Unknown Filter Type:Information Requested Micron Rating:0 Miscellaneous Information   Comments TEST RESULTS are within NORMAL PARAMETERS for this product. Test Results Test Method Test Name Result Min Max ASTM D7220 Sulfur (ppm)6.8 ASTM D2709 Water and Sediment (%)<0.01 mod. ASTM D6304 Water by Karl Fischer (%)0.001 mod. ASTM D6304 Water by Karl Fischer (ppm) Manufacturer Adenosine Triphosphate Content (pg ATP / mL) Manufacturer Aerobic Bacteria (Counts) Manufacturer Bacteria (Counts)0 Manufacturer Fungi (Counts)Negative Manufacturer Mold (Counts)0 mod. ASTM D6468 Thermal Stablity (%)98.1 mod. ASTM D445 Viscosity 40°C (cSt)2.47 mod. ASTM D445 Viscosity 100 °C (cSt) mod. ASTM D664 Acid Number (mg KOH / g) ASTM D7689 Cloud Point (°C)-16 ASTM D7346 Pour Point (°C)-27 ASTM D6371 Cold Filter Plug Point (°C) ASTM D3828 Closed Cup Flash Point (°C)70.5 ASTM D7345 "Predicted D86" Distillation Initial Boiling Point (°C)174.1 ASTM D7345 "Predicted D86"Distillation 10% Recovered (°C)200.8 ASTM D7345 "Predicted D86"Distillation 50% Recovered (°C)251.1 ASTM D7345 "Predicted D86"Distillation 90% Recovered (°C)316.1 ASTM D7345 "Predicted D86" Distillation Final Boiling Point (°C)345.5 ASTM D976 Cetane Index 45.2 ASTM D7777 API Gravity 36.0 ASTM D7777 Density (g / mL) Internal Method Specific Gravity ASTM D4868 BTU Per Gallon (BTU / gal) ASTM D4868 BTU Per Pound (BTU / lb) ASTM D6079 Lubricity (µm) ASTM D130 Copper Corrosion ASTM D482 Ash Content (mass %) ASTM D189 Carbon Residue (%) ASTM D7371 % Biodiesel - FAME (%)  Elemental Analysis mod. ASTM D5185 Result Min Max Iron (ppm)1 Chromium (ppm)0 Nickel (ppm)0 Aluminum (ppm)0 Copper (ppm)0 Lead (ppm)0 Tin (ppm)0 Cadmium (ppm)0 Silver (ppm)0 Vanadium (ppm)0 Silicon (ppm)1 Sodium (ppm)0 Potassium (ppm)0 Titanium (ppm)0 Molybdenum (ppm)0 Antimony (ppm)0 Manganese (ppm)0 Lithium (ppm)0 Boron (ppm)0 Magnesium (ppm)0 Calcium (ppm)0 Barium (ppm)0 Phosphorus (ppm)1 Zinc (ppm)1 Particle Count (particles / mL) ISO 4406 & mod. ISO 11500 Result Min Max ISO Cleanliness Code / / / / / / > 4μm > 6μm > 10μm > 14μm > 21μm > 38μm > 70μm > 100μm Comments are advisory only and are based on the assumption that the sample and data submitted are valid. Results relate only to the items tested. Missing fluid or component information limits the evaluation. No warranty is expressed or implied. Measurement uncertainty available upon request. 4/10/24, 4:38 PM State of Utah Mail - St. George Semi-Annual Diesel Reporting https://mail.google.com/mail/u/0/?ik=36f4379b4d&view=pt&search=all&permthid=thread-f:1787111598196266988&simpl=msg-f:1787111598196266988 1/1 Chad Gilgen <cgilgen@utah.gov> St. George Semi-Annual Diesel Reporting 1 message Jim Blankenau <James.Blankenau@imail.org>Wed, Jan 3, 2024 at 3:53 PM To: Chad Gilgen <cgilgen@utah.gov> Cc: George McGee <George.McGee@imail.org>, Alan Roberts <Alan.Roberts@imail.org> Chad, Please see the attached report for St. George Hospital to meet 40 CFR 60 Dc requirements. Thanks, Jim Jim Blankenau, P.G. Environmental Engineer Intermountain Health, Canyons 383 W. Vine Street (4th floor), Murray, UT 84124 Mobile: 801.484.6114 NOTICE: This e-mail is for the sole use of the intended recipient and may contain confidential and privileged information. If you are not the intended recipient, you are prohibited from reviewing, using, disclosing or distributing this e-mail or its contents. If you have received this e-mail in error, please contact the sender by reply e-mail and destroy all copies of this e-mail and its contents. July to Dec 23Boiler Diesel Fuel Compliance SubmissionSigned.pdf 266K 4/10/24, 4:43 PM State of Utah Mail - IHC Subpart Dc Reports Received https://mail.google.com/mail/u/0/?ik=36f4379b4d&view=pt&search=all&permthid=thread-a:r-1895129688206047432&simpl=msg-a:r-25975318004372…1/1 Chad Gilgen <cgilgen@utah.gov> IHC Subpart Dc Reports Received 1 message Chad Gilgen <cgilgen@utah.gov>Wed, Apr 10, 2024 at 4:42 PM To: James Blankenau <James.Blankenau@imail.org> Hello Jim, I apologize for the delay in responding. I wanted to let you know the DAQ is in receipt of the July 2023 - December 2023 Semi-Annual Subpart Dc reports for the following: IMC LDS Logan McKay Dee Primary Childrens Riverton St. George TOSH Utah Valley Thanks, Chad Chad Gilgen | Manager | Minor Source Compliance 385-306-6500 (cell) Emails to and from this email address may be considered public records and thus subject to Utah GRAMA requirements.