Loading...
HomeMy WebLinkAboutDAQ-2024-004630.L ". .*----.? i' i : I i---t 1251 Lumpkin Rd, Houston, TX 77043-4101- (713) 365-8500 December 12,2023 Sent via Federal Express Bryce Bird, Director Utah Division of Air Quality P.O. Box '144820 195 North 1950 West Salt Lake City, Utah 84116-3100 Environmental Protection Agency, Region Vlll Office of Enforcement, Compliance and Environmental Justice (mail code SENG-AT) 1595 Wynkoop Street Denver, CO80202-1129 Re: 40 CFR Part 60, Subpart OOOO, Annual Report July 01, 2022 through June 30,2023 Wapiti Operating, LLC, Sage Brush Flats Compressor Station, Carbon County, Utah Title V Operating Permit: #500101002, lssued June 14, 2019 Dear Mr. Bird and EPA Region Vlll, ln accordance with Title 40 of the Code of Federal Regulations, Part 60, Subpart OOOO (NSPS OOOO), enclosed is an annual report for the period of July 01, 2022 through June 30, 2023. The report is for three reciprocating compressors powered by engines ENG01, ENG02, and ENG03. There is no a) gas well, b) centrifugal compressor (w/ wet seals), c) pneumatic controller (>6 scf/hr), d) storage vessel (16 tpy), e) natural gas process unit, or other NSPS OOOO affected facility at Wapiti Operating, LLC's Sage Brush Compressor Station. lf you have any questions or need additional information, please contact me at (801) 597-0477 or CRhodes@WapitiEnergy.com. Sincerely, . ! "- r,.r_ Clyde ffhodes Environmental Specialist B-2-12929 General lnformation 560.5420(b)(1)(i) s60.5420(b)(1)(ii0 560.5a20@)(1)(iv) 40 CFR Part 60. Subpart OOOO Annual Report lncludinq Cer.tification of Truth, Accuracv. and Completeness July 01, 2022lhrough June 30,2023 The company name and address of the affected facility. WapitiOperatinq, LLC Saqe Brush Flat Compressor Station -30 miles South of Mvton Remote Location in Carbon County, UT Lat: 39.73611'N Lon: -110.11292"W An identification of each affected facility included in the annual report. Three Bl reciprocatinq compressors powered bv enoines ENG01, ENG02, and ENGO3. Beginning and ending dates of the reporting period. Beqin: Julv 01, 2022 and End: June 30, 2023. A certification by a certifying official of truth, accuracy, and completeness. See Below. s60.5420(b)(1)(i0 Reportinq for Reciprocating Compressors 560.5420(b)(4)(il Cumulative number of hours of operation or the number of months since initial staftup, since October 15,2012, or since the previous reciprocating compressor rod packing replacement, whichever is later. Compressor lD:ENGOl ENG02 ENGO3 Date of Last Packing Change 09t30t21 09t27t21 09t29t21 Hours of Operation w/ Current Packing 12,767 6,640 19,049 Threshold Hours or Months Later of 26,000 Hours or 36 Months s60.5420(b) (4)(ii)Records of deviations specified in paragraph (c)(3)(iii) of this section that occurred during the reporting period. Goinq fon/vard, submission of this NSPS OOOO Report will coincide with submission of the Title V Annual Compliance Certification due on or before March 01 of each calendar vear. Certificate of Truth. Accuracv. and Completeness ln accordance with Operating Permit provision l.K, UAC R307-415-5d, and 40CFRS60.5420(bX1)(iv), to the bestof myknowledge, and based on information and belief formed afterreasonable inquiry, lcertify that the statements and information in this document are true, accurate, and complete. esident & CEO Dae'/L-->cc Z-'L3 .10 CFR Part 60 Subpart OOOO - Standards of Performance for Crude Oil and Natural Gas Facilities for Which Construction, Modification, or Reconstruction Commenced After August 23, 2011, and on or Before September 18,2015 $ 60.5365 Am I subject to this subpart? You are subject to the applicable provisions of this subpart if you are the owner or operator olone or more of the onshore affected tacilities listed in paragraphs (a) through (g) of this section that is locared within the Cmde Oil and Natural Gas Production source category, as defined in g 60.5430 tbr which yoLr commence constntction, modification, or reconstruction zrfter August23,20l l. and on or befbre September 18, 2015. (c) Each reciprocating compressor affected facility, rvhich is a single reciprocating compressor. A reciprocating compressor located at a well site, or an adjacent r.vell site and sewicing more than one well site, is not an affected f'acility under this sLrbpart. $ 60.5385 What standards apply to reciprocating compressor affected facilities? You must comply with the standards in paragraphs (a) through (d) of this section tbr each reciprocating compressor affected facility. (a) You must replace the reciprocating compressor rod packing according to either paragraph (aX l) or (2) of this section or you must comply with paragraph (a)(3) of this sectiorr. (1) Before the compressor has operated for 26,000 hours. The number of hours of operation must be continuously monitored beginning upon initial startup of your reciprocating compressor affected facility, or October [5, 2012, or the date of tlie most recent reciprocating compressor rod packing replacement. whichever is later. (2) Prior to 36 months from the date of the most recent rod packing replacement, or 36 months tiom the date of starrup for a new reciprocating compressor for which the rod packing has not yet been replaced. (3) Collect the emissions tiom the rod packing using a rod packing emissions collection system which operates under negative pressure and route the rod packing emissions to a process throu-eh a closed vent system that mccts thc requirements of $ 60.54 I I (a). (b) You must demonstrate initial compliance with standards that apply to reciprocating compressor aff-ected facilities as required by $ 60.5410. (c) You must demonstrate continuous compliance with standards that apply to reciprocatint compressor aftbcted tacilities as required by $ 60.5a15. (d) You must perfonn the required notification, recordkeeping, and reporting as required by $ 60.5a20. $ 60.5410 How do I demonstrate initial compliance rvith the standards for my gas well affected facility, my centrifugal compressor affected facility, my reciprocating compressor affected facility, my pneumatic controller affected facility, my storage vessel affected facility, and my equipment leaks and sweetening unit at'l'ected lacilities at onshore natural gas processing plants l (c) To achieve initial compliance with the standards fbr each reciprocatins compressor attectetl tacility you must comply w'ith paragraphs (c)( l) through (4) of this section. ( I ) tf courplying with $ 60.5385(aX I ) or (2), during the initial compliance period, yoLr must continuously monitor the number of hours of operation or track the number of months since the last rod packing rcplaccmcnt. (3) You must submit tlic initial annual rcport fbr yoLrr rcciprocating compressor as recluired in $ 60.5420(b). (4) You must maintain the records as specit-red in $ 60.5420(c)(3) fbr each reciprocating corllpressor atl'ected f'acility. $ 60.5415 How do I demonstrate continuous compliance with the standards for my gas well affected facilitv, my centrifugal compressor affected facility, my stationary reciprocating compressor affected facility, my pneumatic controller affected facility, my storage vessel affected facilit_v, and my affected facilities at onshore natural gas processing plants? (c) For each reciprocating compressor aftbcted f'acility cornplying with $ 60.538-5(a)( I ) or (2), you must demonstrate continuous compliance according to paragraphs (c)( I ) through (3) of this section. ( I ) You must continuously monitor the number of hours of operation fbr each reciprocating compressoraff'ected facility ortrack the numberof months since initial startup, orOctober 15,2012, or the date of the most recent reciprocating compressor rod packing replacement, whichever is [ater. (2) You must submit the annual report as required in $ 60.5420(b) and maintain records as required in $ 60.5420(c)(3). (3) You must replace the reciprocating compressor rod packing befbre the total number of hours of operation reaches 26,000 hours or the number of rnonths since the most recent rod packing replacement reaches 36 months. $ 60.5420 What are my notification, reporting, and recordkeeping requirements? (b) Reporting requirements. You must submit annual repofts containing the information specified in paragraphs (b)( I ) through (6) of this section to the Administrator and perfonnance test reports as specified in paragraph (b)(7) or (8) of this section. The initial annual report is due no later than 90 days after the end of the initial compliance period as determined according to $ 60.5410. Subsequent annual reports are due no later than same date each year as the initial annual report. If you o\,vn or operate more than one affected facility, you may submit one report for multiple affected facilities provided the report contains all of the infonlation required as specit-red in paragraphs (bXl)through (6) of this section. Annual reports may coincide with title V reports as long as all the required elements of the annual report are included. You may arrange with the Administrator a common schedule on which reports required by this part may be submitted as long as the schedule does not extend the reporting period. ( I ) The general information specified in paragraphs (bX I )(i) through (iv) of this section. (i) The company name and address of the affected facility. (ii) An identification of each aftected thcility being included in the annual report. (iii) Beginning and ending dates of the reporting periocl. (iv) A certification by a certifying official of tmth. accrrracy. and completeness. This certitlcation shallstate that, based on infbnnation and belief tbnned afier reasonable inquiry, the statenlents and intbrmation in the document are truc, accuratc, and complctc. (4) For each reciprocating compressor affectcd facility. thc inlonnation spccified in paragraphs (bX4Xi) through (ii) of this section. (i) The cumulative number of hours of operation or the number of months since initial startup, since October 15,2012, or since the previous reciprocating compressor rod packing replacement. whichever is later. (ii) Records of deviations specified in paragraph (cX3)(iii) of this section that occurrcd dr"rring the reporting period. (c) Recordkeeping requirements. You must maintain the records identified as specitied in $ 60.7(t) and in paragraphs (cXl) through (14) of this section. All records required by this subpart must be maintained either onsite or at the nearest local treld otllce tbr at least -5 years. (3) For each reciprocatin-q compressors aft'ected tacility, you must maintain the records in paragraphs (c)(3Xi) through (iii) of this section. (i) Records of the cumulative number of hours of operation or number of months since initial startup or October | 5. 2012, or the previous replacement of the reciprocating compressor rod packing, whichever is later. (ii) Records of the date and time of each reciprocating compressor rod packing replacement, or date of installation of a rod packing emissions collection system and closed vent system as specified in $ 60.5385(aX3) (iii) Records of deviations in cases r,vhere the reciprocating compressor was not operated in compliance with the requirements specified in $ 60.5385.