HomeMy WebLinkAboutDAQ-2024-0082251 DAQC-501-24 Site ID 4704 (B4) MEMORANDUM TO: STACK TEST FILE – FINLEY RESOURCES INC. – Cabin Cruiser 11-13A-4-2 THROUGH: Rik Ombach, Minor Source Oil and Gas Compliance Section Manager FROM: Paul Bushman, Environmental Scientist DATE: May 23, 2024 SUBJECT: Sources: One (1) 40 hp Ajax E-565 engine; SN: 86612 Contact: Karen Pratt: (720) 990-9927 Location: Remote location in Uintah County, UT Test Contractor: Oasis Emissions Consultants, Inc. Permit/AO#: Permit by Rule Action Code: TR Subject: Review of stack test report dated May 10, 2024 On May 15, 2024, Utah Division of Air Quality (DAQ) received a test report for one (1) 40 hp Ajax E-565 engine at Cabin Cruiser 11-13A-4-2, Uintah County, UT. Testing was performed April 24, 2024, to demonstrate compliance with the emission limits found in 40 CFR Part 60, Subpart JJJJ. The calculated test results are: Source Test Date Test Method Pollutant Tester Results DAQ Results Limits Ajax E-565; SN: 86612 April 24, 2024 7E NOx 0.37 g/hp-hr 0.368 g/hp-hr 2.83 g/hp-hr 10 CO 1.71 g/hp-hr 1.702 g/hp-hr 4.85 g/hp-hr 25A HC 13.11 g/hp-hr 18.254 g/hp-hr DEVIATIONS: None. CONCLUSION: The stack test report appears to be acceptable. RECOMMENDATION: The emissions from the Ajax E-565 engine should be considered to have been in compliance with the emission limits of 40 CFR Part 60, Subpart JJJJ during testing. It is recommended to use the empirical data of the test results for the current reevaluation of UAC R307-510. ATTACHMENTS: DAQ stack test review excel spreadsheets, Finley Resources Inc. stack test report. 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59