HomeMy WebLinkAboutDAQ-2024-0082251
DAQC-501-24
Site ID 4704 (B4)
MEMORANDUM
TO: STACK TEST FILE – FINLEY RESOURCES INC. – Cabin Cruiser 11-13A-4-2
THROUGH: Rik Ombach, Minor Source Oil and Gas Compliance Section Manager
FROM: Paul Bushman, Environmental Scientist
DATE: May 23, 2024
SUBJECT: Sources: One (1) 40 hp Ajax E-565 engine; SN: 86612
Contact: Karen Pratt: (720) 990-9927
Location: Remote location in Uintah County, UT
Test Contractor: Oasis Emissions Consultants, Inc.
Permit/AO#: Permit by Rule
Action Code: TR
Subject: Review of stack test report dated May 10, 2024
On May 15, 2024, Utah Division of Air Quality (DAQ) received a test report for one (1) 40 hp Ajax
E-565 engine at Cabin Cruiser 11-13A-4-2, Uintah County, UT. Testing was performed April 24, 2024, to
demonstrate compliance with the emission limits found in 40 CFR Part 60, Subpart JJJJ. The calculated
test results are:
Source Test
Date
Test
Method Pollutant Tester Results DAQ Results Limits
Ajax E-565;
SN: 86612
April 24,
2024
7E NOx 0.37 g/hp-hr 0.368 g/hp-hr 2.83 g/hp-hr
10 CO 1.71 g/hp-hr 1.702 g/hp-hr 4.85 g/hp-hr
25A HC 13.11 g/hp-hr 18.254 g/hp-hr
DEVIATIONS: None.
CONCLUSION: The stack test report appears to be acceptable.
RECOMMENDATION: The emissions from the Ajax E-565 engine should be considered
to have been in compliance with the emission limits of 40 CFR
Part 60, Subpart JJJJ during testing. It is recommended to use the
empirical data of the test results for the current reevaluation of
UAC R307-510.
ATTACHMENTS: DAQ stack test review excel spreadsheets, Finley Resources Inc.
stack test report.
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59