HomeMy WebLinkAboutDAQ-2024-0081681
DAQC-506-24
Site ID 4705 (B4)
MEMORANDUM
TO: STACK TEST FILE – FINLEY RESOURCES INC. – Cabin Cruiser 14-3A-4-2
THROUGH: Rik Ombach, Minor Source Oil and Gas Compliance Section Manager
FROM: Paul Bushman, Environmental Scientist
DATE: May 23, 2024
SUBJECT: Sources: One (1) 40 hp Ajax E-565 engine; SN: 86584
Contact: Karen Pratt: (720) 990-9927
Location: Remote location in Uintah County, Utah
Test Contractor: Oasis Emissions Consultants, Inc.
Permit/AO#: Permit by Rule
Action Code: TR
Subject: Review of stack test report dated May 10, 2024
On May 15, 2024, Utah Division of Air Quality (DAQ) received a test report for one (1) 40 hp Ajax
E-565 engine at Cabin Cruiser 14-3A-4-2, Uintah County, Utah. Testing was performed April 24, 2024,
to demonstrate compliance with the emission limits found in 40 CFR Part 60, Subpart JJJJ. The calculated
test results are:
Source Test Date Test Method Pollutant Tester Results DAQ Results Limits
Ajax E-565;
SN: 86584
April 24,
2024
7E NOx 0.1 g/hp-hr 0.098 g/hp-hr 2.83 g/hp-hr
10 CO 2.91 g/hp-hr 2.894 g/hp-hr 4.85 g/hp-hr
25A HC 180.47 g/hp-hr 176.550 g/hp-hr
DEVIATIONS: None.
CONCLUSION: The stack test report appears to be acceptable.
RECOMMENDATION: The emissions from the Ajax E-565 engine should be considered to have
been in compliance with the emission limits of 40 CFR Part 60, Subpart
JJJJ during testing. It is recommended to use the empirical data of the
test results for the current reevaluation of UAC R307-510.
ATTACHMENTS: DAQ stack test review excel spreadsheets, Finley Resources Inc. stack
test report.
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59