DAQC-486-24
Site ID 11518 (B1)
Jeffery Cowlishaw
Staker Parson Companies
2350 South 1900 West
Ogden, Utah 84020
Dear Mr. Cowlishaw:
Re: Staker Parson Companies – Temporary Relocation/Operation, Notice of Intent – Rich
County
Your Notice of Intent dated May 15, 2024, to relocate portable aggregate equipment to the
temporary project located at 3637 Rocky Ridge Road, Laketown, Utah, was received by the Utah
Division of Air Quality (DAQ) and has been reviewed.
The following equipment has been approved for operation for this temporary project:
Cone crusher
Screen
Jaw crusher
795 kW generator
The above equipment has been permitted for operation in the State of Utah by the Staker & Parson
Companies portable Approval Order (AO) DAQE-AN115180014-15 dated July 6, 2015. Approval
is granted to relocate and operate this equipment at the new location for a period not to exceed 180
operational days. As per Utah Administrative Code (UAC) R307-401-17, the operation of
equipment at this temporary site may be for up to 180 working days in any calendar year not to
exceed 365 consecutive days, starting from the initial relocation date. Approval is subject to the
conditions of the dust control plan submitted for this location and the above referenced AO. Hours
of operation shall be held to 16 hours each day. The maximum production rate shall be held to the
requested 700 tons per hour.
6 Û Ü Û Ù Û Ý
DAQC-486-24
Page 2
Emissions for this project have been estimated at the following:
Pollutant gram/sec lbs/hr lbs/24 hr tons/yr
PM10 2.65 21.02 210.19 16.39
SOx 1.07 8.49 84.91 6.62
NOx 7.06 56.06 560.64 43.73
CO 1.84 14.58 145.83 11.37
VOC 0.29 2.27 22.68 1.77
The owner/operator shall maintain records of the actual operation hours, days, and production
rate, of the above referenced equipment at this relocation site and have the ability to submit the
information to the DAQ upon the request of representatives of the director. Please make certain
that the plant operator is aware of all the location specific requirements for this site and the
conditions of the aforementioned AO.
Federal New Source Performance Standards Subpart OOO requires that initial Method 9
observations be performed for all applicable portable crushers, screens, and attached conveyors.
Subpart OOO also mandates that all crushers constructed, modified, or reconstructed on or after
April 22, 2008, which are not enclosed, must install spray bars on the equipment and keep
maintenance records to ensure proper spray bar operations.
Utah Division of Water Quality Storm Water Permits and regulations may apply to this temporary
project. Please refer to Utah DEQ Water Quality’s current storm water construction requirements
for additional information.
This approval for relocation in no way releases the owner or operator from any liability for
compliance with all other applicable federal, state, and local regulations including the UAC.
If you have any questions regarding this relocation authorization or the temporary relocation
process please contact Susan Weisenberg at (385) 306-6512.
Sincerely,
Jay P. Morris
Assistant Director
JPM:SW:rh
Enclosure: Submitted Temporary Relocation Form
cc: Bear River Health Department
4 * - - $ . — 4 A A v A ? A C @ A w A @ ˜
Susan Weisenberg <sweisenberg@utah.gov>
Portable/Temporary Relocation Form
1 message
noreply@qemailserver.com <noreply@qemailserver.com>Wed, May 15, 2024 at 10:10 AM
Reply-To: trigger@qemailserver.com
To: sweisenberg@utah.gov
Susan/Chad:
Site # -- Staker Parson has requested a Temporary Relocation. Please see the information below. Any attachments can
be access by clicking on the links.
Recipient Data:
Time Finished: 2024-05-15 10:10:46 MDT
IP: 165.225.10.81
ResponseID: R_5mlNV2dIsnwHRBp
Link to View Results: Click Here
URL to View Results: https://utahgov.iad1.qualtrics.com/apps/single-response-reports/reports/
SABqWiAN8KoLTO%2EDSSUSxF-294UNhlghPmA%2EPVgaXqPa-X2LihM9iN9yew390dThvOTH0dVwRSP
1l7lJOvRG6ABX6uf6BD2wB5v4K7pscCL28jh9sXrLIOK43LGbbVsRHH1pH0j-VRlZv1qbyQz1q6xk5S0YweTRg59NAf
MQLKpx4PjGk2TMsGl1j4Sv6hcPLZhRc6JtqmGHhrBBjbd46yq74JYkT8Vsnc0e3dfxToWKSWO-%
2ESbdMDw3JmzNGImnNIUsGzgvIg5LsHCIZfvLpodJBsJY1JP%2EbLqEPgdvbkZ7FY9Wc6N5jD-
CUrR2eFuISp0ZfLADyc7h2s%2EliUJ4Rg
Response Summary:
Please fill out the information below:
Contact Person: Jeffery Cowlishaw
Company Name: Staker Parson
Mailing Address: 2350 S 1900 W
City: Ogden
Zip: 84401
Phone Number: 385-405-4315
Email: jeffery.cowlishaw@stakerparson.com
Is the site located within a PM2.5 non-attainment and maintenance plan areas on cleared land grea...
No
All temporary relocation projects are required to submit a Fugitive Dust Control Plan (FDCP). Lo...
64875DBE61
Briefly give directions to the site and/or physical address:
3637 Rocky Ridge Rd Laketown, UT 84028. Enter Bear Lake valley from US 89. Travel south to Rocky Ridge Road. Go
west on dirt road to Staker Parson sign. Turn right onto access road. Check in at scalehouse.
Proposed Relocation Information:
Closest City Laketown
County Rich
UTM X Coordinates 468894.64
UTM Y Coordinates 4635592.19
Approximate distance to the nearest house/business approximately 2796 feet
UTM X Coordinates to nearest house/business 469098.5
UTM Y Coordinates to nearest house/business 4634770.9
5/21/24, 11:29 AM State of Utah Mail - Portable/Temporary Relocation Form
https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1799135643332585868%7Cmsg-f:1799135643332585868&…1/2
Does this site currently have a permit with DAQ?
No
Please provide the permit ID for the equipment? (DAQE-XXXXXXXXX-XX)
DAQE-AN115180014-15
Please list all the Equipment on Site:Note: It is important to identify ALL diesel powered engine...
1
Equipment Type Cone Crusher
Serial or ID# II.A.124
Design Capacity 485tph
2
Equipment Type Screen
Make/Model
Serial or ID# II.A.186
Design Capacity 7x20
3
Equipment Type Jaw Crusher
Serial or ID# II.A.124
Design Capacity 560tph
4
Equipment Type Generator
Serial or ID# II.A.730
Design Capacity 795KW
Please attach a site diagram showing the equipment layout and general site dimensions for this re...
https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_1QJzDbPEHml8ehZ
Have any other state or local regulatory agencies issued any other "Conditional Use Permits" for...
No
Operational Information: (Please note: Operating time over 16 hours in a 24 hour period will re...
Total Hours of operation per 24 hr period 16
Starting time of operation (am/pm) 6am
Ending time of operation (am/pm) 10pm
Maximum hourly production rate for project 700tph
Expected startup date 05/30/2024
Expected completion date 05/29/2025
What type of application is this for?
New Application
In accordance with the fee schedule approved by the Utah State Legislature, the Division of Air Q...
https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_2B5ORoGliBJAKk3
Owner/Operator Representative:
https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_BzarvJXVvlCGgY9
5/21/24, 11:29 AM State of Utah Mail - Portable/Temporary Relocation Form
https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1799135643332585868%7Cmsg-f:1799135643332585868&…2/2