Loading...
HomeMy WebLinkAboutDAQ-2024-005187 195 North 1950 West • Salt Lake City, UT Mailing Address: P.O. Box 144820 • Salt Lake City, UT 84114-4820 Telephone (801) 536-4000 • Fax (801) 536-4099 • T.D.D. (801) 903-3978 www.deq.utah.gov Printed on 100% recycled paper State of Utah Department of Environmental Quality Kimberly D. Shelley Executive Director DIVISION OF AIR QUALITY Bryce C. Bird Director SPENCER J. COX Governor DEIDRE HENDERSON Lieutenant Governor DAQC-203-24 Site 11941 (B1) Olivia Cramm Ames Construction, Inc. 3737 West 2100 South West Valley City, Utah 84120 Dear Ms. Cramm: Re: Ames Construction, Inc. – Temporary Relocation/Operation, Notice of Intent – Salt Lake County Your Notice of Intent dated February 29, 2024, to relocate portable concrete batch plant equipment to the temporary project for the Salt Lake City International Airport, located from Exit I-215 at 2100 North, west toward the airport, then north bound to 4000 West, turning west at the T in the road, then 1200 feet north, Salt Lake County, Utah, was received by the Utah Division of Air Quality (DAQ) and has been reviewed. The following equipment has been approved for operation for this temporary project: Erie MP-12CP concrete batch plant Caterpillar 825 kW diesel-fired generator Caterpillar 99 kW diesel-fired generator Two (2) HM1.7G plant boilers Miscellaneous belt feeder and other equipment Approval is subject to the conditions of the dust control plan submitted for this location and the current Ames Construction portable Approval Order (AO) DAQE-AN119410013-22 dated September 26, 2022. Approval is granted to relocate and operate this equipment at the new location for a period not to exceed 180 operational days. As per Utah Administrative Code (UAC) R307-401-17, the operation of equipment at this temporary site may be for up to 180 working days in any calendar year not to exceed 365 consecutive days, starting from the initial relocation date. The operational days per site cannot be extended beyond the stipulated 365 consecutive day period. Hours of operation shall be held to 16 hours per each 24-hour day. The maximum production rate shall be held to the requested 300 cubic yards per hour. The DAQ does not currently estimate emissions for temporary concrete batch plant operations. / % ß Û Ù Û Ý DAQC-203-24 Page 2 The owner/operator shall maintain records of the actual operation hours, days, and production rate, of the above referenced equipment at this relocation site and have the ability to submit the information to the DAQ upon the request of representatives of the director. Please make certain that the plant operator is aware of all the location specific requirements for this site and the conditions of the aforementioned AO. Utah Division of Water Quality Storm Water Permits and regulations may apply to this temporary project. Please refer to Utah DEQ Water Quality’s current Storm Water Construction requirements for additional information. This approval for relocation in no way releases the owner or operator from any liability for compliance with all other applicable federal, state, and local regulations including the UAC. If you have any questions regarding this relocation authorization or the temporary relocation process please contact Susan Weisenberg at (385) 306-6512. Sincerely, Jay P. Morris Assistant Director JPM:SW:rh Enclosure: Submitted Temporary Relocation Form cc: Salt Lake County Health Department 4 * - - $ . — - D v A ? A C @ A w D E ˜ 2/29/24, 5:01 PM State of Utah Mail - Portable/Temporary Relocation Form https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1792267492170156782%7Cmsg-f:1792267492170156782&…1/3 Susan Weisenberg <sweisenberg@utah.gov> Portable/Temporary Relocation Form 1 message noreply@qemailserver.com <noreply@qemailserver.com>Thu, Feb 29, 2024 at 1:44 PM Reply-To: trigger@qemailserver.com To: sweisenberg@utah.gov Susan/Chad: Site # -- Ames Construction has requested a Temporary Relocation. Please see the information below. Any attachments can be access by clicking on the links. Recipient Data: Time Finished: 2024-02-29 13:44:22 MST IP: 205.182.133.105 ResponseID: R_6CByqTRQpg5A1a5 Link to View Results: Click Here URL to View Results: https://utahgov.iad1.qualtrics.com/apps/single-response-reports/reports/Pfwa18fS9jrxJR1ikxW- seu3UYmzMY1WsKEFgmMezS%2EQVckNc5sbIfHdlHE1bkzGfh0zZUGWz9ik5N4UO9FKyIUBixh4JUpCi213K E0qXk5LMTXPWmvvAI2hKqyI7W-OyGmB3feDgz%2EbNzIAOdJ6RUk3LrhMgtW2UR9drla GVxIOG4YZ3fBPzPdJZr%2E56F%2EyvYz%2EYrjjcaDEhGEAlCqFk791Sxt0GHRi XFNwXWRzt2kYRiPEVVFyVN1jnQzk4dzoRxDuyIk76NZwHZLRg0bsCHHOv8FtNnYSL4lCK5hQG3O0XzuEb8wsdpNKvD QGiZ5Ra1wIWGakdgC85Fg-08MmsA Response Summary: Please fill out the information below: Contact Person: Olivia Cramm Company Name: Ames Construction Mailing Address: 3737 West 2100 South City: Salt Lake City Zip: 84120 Phone Number: 8019778012 Email: Oliviacramm@amesco.com Is the site located within a PM2.5 non-attainment and maintenance plan areas on cleared land grea... Yes All temporary relocation projects are required to submit a Fugitive Dust Control Plan (FDCP). Lo... 99CCB4984D Briefly give directions to the site and/or physical address: Exit I-215 at 2100 North, go West toward SLC-IA, follow road as turns into N 4000 W, turn West at T in road, about 1200FT turn north into construction project Proposed Relocation Information: Closest City Salt Lake City County Salt Lake UTM X Coordinates 416240.23 UTM Y Coordinates 4516604.78 Approximate distance to the nearest house/business 1490 UTM X Coordinates to nearest house/business 416701.40 UTM Y Coordinates to nearest house/business 4516408.01 2/29/24, 5:01 PM State of Utah Mail - Portable/Temporary Relocation Form https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1792267492170156782%7Cmsg-f:1792267492170156782&…2/3 Does this site currently have a permit with DAQ? No Please provide the permit ID for the equipment? (DAQE-XXXXXXXXX-XX) AN119410013-22 Please list all the Equipment on Site:Note: It is important to identify ALL diesel powered engine... 1 Equipment Type Mobile Concrete Batch Plant Make/Model Erie MP-12CP Serial or ID# 3620001 Manufactured Date 2020 Design Capacity 33 cy/hr 2 Equipment Type II.A.II Diesel-Fired Generator Make/Model Caterpillar Serial or ID# 3901001 Manufactured Date 2001 Design Capacity 825 kW 3 Equipment Type HM1.7G Plant Boiler Make/Model Sioux Serial or ID# 22-5700 Manufactured Date 2022 Design Capacity 1890 btu/hr 4 Equipment Type II.A.62 Diesel-Fired Generator Make/Model Caterpillar Serial or ID# 8412003 Manufactured Date 2012 Design Capacity 99 kW 5 Equipment Type II.A.19 Belt Feeder Make/Model Caterpillar Serial or ID# 3404001 Manufactured Date 2000 Design Capacity 600 tph 6 Equipment Type II.A.21 Misc. Equipment 7 Equipment Type HM1.7G Boiler Make/Model Sioux Serial or ID# 21-5482 Manufactured Date 2021 Design Capacity 1890 btu/hr Please attach a site diagram showing the equipment layout and general site dimensions for this re... https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_12i0QnosprpyK9z Have any other state or local regulatory agencies issued any other "Conditional Use Permits" for... No Operational Information: (Please note: Operating time over 16 hours in a 24 hour period will re... Total Hours of operation per 24 hr period 16 Starting time of operation (am/pm) 6:00 am Ending time of operation (am/pm) 4:30 pm Maximum hourly production rate for project 300 cy/hr Expected startup date 03/20/2024 Expected completion date 09/16/2024 What type of application is this for? New Application In accordance with the fee schedule approved by the Utah State Legislature, the Division of Air Q... https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_3qPOVgqs3yeOXUl 2/29/24, 5:01 PM State of Utah Mail - Portable/Temporary Relocation Form https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1792267492170156782%7Cmsg-f:1792267492170156782&…3/3 Owner/Operator Representative: https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_2f2seqK1oNZDMcr