HomeMy WebLinkAboutDAQ-2024-0050111
DAQC-102-24
Site ID 12596 (B4)
MEMORANDUM
TO: STACK TEST FILE – KERN RIVER GAS TRANSMISSION COMPANY –
Salt Lake Compressor Station
THROUGH: Rik Ombach, Minor Source Oil and Gas Compliance Section Manager
FROM: Paul Bushman, Environmental Scientist
DATE: February 5, 2024
SUBJECT: Sources: Solar Mars 100-15000S Turbine Unit 2 (T-2)
Contact: Denise Kohtala: 801-937-6347
Location: 5051 West 150 South, Salt Lake City, Salt Lake County, UT
Test Contractor: TRC Environmental Corporation
Permit/AO#: DAQE-AN125960016-23 dated October 6, 2023
Action Code: TR
Subject: Review of stack test report received February 2, 2024
On February 2, 2024, Utah Division of Air Quality (DAQ) received a test report for a Solar Mars 100-
15000S Turbine Unit 2 (T-2) at Salt Lake Compressor Station, Salt Lake County, UT. Testing was
performed on December 6, 2023, to demonstrate compliance with the emission limits found in condition
II.B.2.a of Approval Order DAQE-AN125960016-23 and 40 CFR Part 60 Subpart GG. The calculated
test results are:
Source Test Date Unit
Load
Pollutant Method Tester Results DAQ Results Limits
Solar Mars
100-
15000S
Turbine
Unit 2
(T-2)
December
6, 2023
High
NOx 7E
7.14 lb/hr 7.148 lb/hr 9.48 lb/hr
18.04 ppmvd @ 15%
O2
18.040 ppmvd
@ 15% O2 25 ppmvd @ 15% O2
CO 10
0.27 lb/hr 0.271 lb/hr 10.38 lb/hr
1.13 ppmvd @ 15%
O2
1.127 ppmvd
@ 15% O2 50 ppmvd @ 15%O2
Med-
High
NOx 7E
6.12 lb/hr 6.116 lb/hr 9.48 lb/hr
16.66 ppmvd @ 15%
O2
16.657 ppmvd
@ 15% O2 25 ppmvd @ 15% O2
CO 10
0.23 lb/hr 0.222 lb/hr 10.38 lb/hr
1.03 ppmvd @ 15%
O2
0.997 ppmvd
@ 15% O2 50 ppmvd @ 15%O2
Med-
Low
NOx 7E
6.50 lb/hr 6.503 lb/hr 9.48 lb/hr
18.67 ppmvd @ 15%
O2
18.673 ppmvd
@ 15% O2 25 ppmvd @ 15% O2
CO 10
0.20 lb/hr 0.205 lb/hr 10.38 lb/hr
0.97 ppmvd @ 15%
O2
0.970 ppmvd
@ 15% O2 50 ppmvd @ 15%O2
2
Source Test Date Unit
Load
Pollutant Method Tester Results DAQ Results Limits
Low
NOx 7E
4.60 lb/hr 4.578 lb/hr 9.48 lb/hr
14.40 ppmvd @ 15%
O2
14.300 ppmvd
@ 15% O2 25 ppmvd @ 15% O2
CO 10
0.25 lb/hr 0.244 lb/hr 10.38 lb/hr
1.26 ppmvd @ 15%
O2
1.253 ppmvd
@ 15% O2 50 ppmvd @ 15%O2
DEVIATIONS: None.
CONCLUSION: The stack test report appears to be acceptable.
RECOMMENDATION: The emissions from Turbine Unit 2 (T-2) should be considered to have
been in compliance with the emission limits of condition II.B.2.a. of the
AO and 40 CFR Part 60 Subpart GG during testing.
ATTACHMENTS: DAQ stack test review excel spreadsheets, Kern River Gas Transmission
Company stack test report.
Unit 2 high $1_RM 2, 2F, 2G, 2H, 3A, 6C, 7E, 10, _ 19 - RA (B_W(Modified Feb. 27, 2018)
Reference Methods 2, 3A, 6C, 7E, 10, & 19
Source Information
Company Name Kern River Gas Transmission Company
Company Contact:Denise Kohtala
Contact Phone No.801-937-6347
Stack Designation:Salt Lake Compressor Station Turbine Unit 2 High
Test & Review Dates
Test Date:12/6/2023 &
Review Date: 2/5/2024
Observer:Not observed
Reviewer:Paul Bushman
Emission Limits Emission Rates
SO2 NOX CO SO2 NOX CO
lbs./MMBtu
lbs./hr. 9.5 10.4 7.148 0.271
ppm 25.0 50.00 18.040 1.127
ppm @ ISO
%O2 Correction as a whole #15.00 15.00
Test Information
Equivalent
Diameter (in.)As ft^2 Y Dl H @ Cp Pbar Pq (static)
Ps
Stack Pressure
90.00 56.250 0
10
Contractor Information
Contact:Jeffery Daniels
Contracting Company: TRC Environmental Corporation
Address: 400 Corporate Circle, Suite P, Golden CO 80401
Phone No.: 630-880-4754
Project No.:
8634
Division of Air Quality
Instrumental Reference Methods - Gaseous Measurements
Rectangular
Method 19 - F factors for Coal, Oil, and Gas
Fd Fw Fc
dscf/MMBtu wscf/MMBtu scf/MMBtu Diluent
F factor used
O2
CO2
Anthracite 2
Bituminous 2
Lignite
Natural
Propane
Butane
10100
COAL
OIL
GAS
9780
9860
9190
8710
8710
8710
10540
10640
11950
320
10610
10200
10390
1970
1800
1910
1420
1040
1190
1250
Wet CEM
Correct For O2
CO2 Interference w/CO
Yes
Yes
Yes
Unit 2 high $1_RM 2, 2F, 2G, 2H, 3A, 6C, 7E, 10, _ 19 - RA (B_W(Modified Feb. 27, 2018)
Calibration Error Test
Test Date December 6, 2023 O2
CS - Cal. Span 22.02
Units %
Cylinder No. Expiration
Date Cal. Gas CV- Certified
Concentration
CDir or CS -
Measured
Concentration
Difference
ACE Eq. 7E-1
Analyzer Cal.
Error
Status
Low-level 0.00 0.00 0.00 0.00%Passed Cal.
SG9166178BAL 07/18/31 Mid-level 10.21 10.43 0.22 0.98%Passed Cal.
CC58424 07/30/27 High-level 22.02 22.00 0.02 0.09%Passed Cal.
% of Span Sec. 8.2.1 Cal Gas Verification
0 to 20% of CS - Cal. Span Low-Level 0.00%
40 to 60% of Cal. Span Mid-level 46.37%
100% of Cal. Span High-level 100.00%
Test Date December 6, 2023 CO2
CS - Cal. Span 21.59
Units %
Cylinder
No.
Expiration
Date Cal. Gas CV- Certified
Concentration
CDir or CS -
Measured
Concentration
Difference
ACE Eq. 7E-1
Analyzer Cal.
Error
Status
Low-level 0.00 -0.03 0.03 0.116%Passed Cal.
SG9166178BAL 07/18/31 Mid-level 9.91 10.24 0.33 1.542%Passed Cal.
CC58424 07/30/27 High-level 21.59 21.57 0.02 0.097%Passed Cal.
% of Span Sec. 8.2.1 Cal Gas Verification
0 to 20% of Cal. Span Low-Level 0.00%
40 to 60% of Cal. Span Mid-level 45.90%
100% of Cal. Span High-level 100.00%
Test Date SO2
CS - Cal. Span
Units ppm
Cylinder
No.
Expiration
Date Cal. Gas CV- Certified
Concentration
CDir or CS -
Measured
Concentration
Difference
ACE Eq. 7E-1
Analyzer Cal.
Error
Status
Low-level
Mid-level
High-level
% of Span Sec. 8.2.1 Cal Gas Verification
0 to 20% of Cal. Span Low-Level
40 to 60% of Cal. Span Mid-level
100% of Cal. Span High-level
Test Date December 6, 2023 NOx
CS - Cal. Span 50.25
Units ppm
Cylinder
No.
Expiration
Date Cal. Gas CV- Certified
Concentration
CDir or CS -
Measured
Concentration
Difference
ACE Eq. 7E-1
Analyzer Cal.
Error
Status
Low-level 0.00 -0.03 0.03 0.062%Passed Cal.
CC365571 10/31/26 Mid-level 25.23 25.10 0.13 0.263%Passed Cal.
EB0119277 05/04/28 High-level 50.25 50.22 0.03 0.070%Passed Cal.
% of Span Sec. 8.2.1 Cal Gas Verification
0 to 20% of Cal. Span Low-Level 0.00%
40 to 60% of Cal. Span Mid-level 50.21%
100% of Cal. Span High-level 100.00%
Test Date December 6, 2023 CO
10.38 CS - Cal. Span 50.14
50 Units ppm
Cylinder
No.
Expiration
Date Cal. Gas CV- Certified
Concentration
CDir or CS -
Measured
Concentration
Difference
ACE Eq. 7E-1
Analyzer Cal.
Error
Status
Low-level 0.00 0.10 0.10 0.199%Passed Cal.
CC365571 10/31/26 Mid-level 25.32 25.00 0.32 0.638%Passed Cal.
EB0119277 05/04/28 High-level 50.14 49.98 0.16 0.313%Passed Cal.
% of Span Sec. 8.2.1 Cal Gas Verification
0 to 20% of Cal. Span Low-Level 0.00%
40 to 60% of Cal. Span Mid-level 50.50%
100% of Cal. Span High-level 100.00%
Valid Cal Gas
Valid Cal Gas
Valid Cal Gas
Valid Cal Gas
Valid Cal Gas
Valid Cal Gas
Valid Cal Gas
Valid Cal Gas
Unit 2 high $1_RM 2, 2F, 2G, 2H, 3A, 6C, 7E, 10, _ 19 - RA (B_W(Modified Feb. 27, 2018)
Division of Air Quality Stack Test Review of
Kern River Gas Transmission Company
SO2 NOX CO CO2 O2 Salt Lake Compressor Station Turbine Unit 2 High
CS Calibration Span 50.25 50.14 21.59 22.02
Units ppm ppm ppm %%Unprotected
CV - Cylinder Value: SO2 NOX CO CO2 O2
Low-Level 0.00 0.00 0.00 0.00
Mid-Level 25.23 25.32 9.91 10.21
High-Level 50.25 50.14 21.59 22.02
0 to 20% of Cal. Span 0.00%0.00%0.00%0.00%
40 to 60% of Cal. Span 50.2%50.5%45.9%46.4%
100% of Cal. Span 100.0%100.0%100.0%100.0%
Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration.
CDir CMA 25.23 25.32 9.91 10.21
Calibration Error Test
Cs - Measured Concentration SO2 NOX CO CO2 O2
Low-Level -0.03 0.10 -0.03 0.00
Mid-Level 25.10 25.00 10.24 10.43
High-Level 50.22 49.98 21.57 22.00
Enter Up-scale Analyzer Response to be used during testing.
ACE Eq. 7E-1 25.10 25.00 10.24 10.43
Low-Level 0.06%0.20%0.12%0.00%
ppmdv Difference 0.031 0.1 0.025 0
Status Passed Cal. Passed Cal. Passed Cal.Passed Cal.
Mid-Level 0.26%0.64%1.54%0.98%
ppmdv Difference 0.132 0.32 0.333 0.215
Status Passed Cal. Passed Cal. Passed Cal.Passed Cal.
High-Level 0.07%0.31%0.10%0.09%
ppmdv Difference 0.035 0.157 0.021 0.02
Status Passed Cal. Passed Cal. Passed Cal.Passed Cal.
Pre-Test Sampling System Bias
Initial Values SO2 NOX CO CO2 O2
CO - Low-Level 0.32 0.00 0.00 0.03 System Bias.
SBi - Zero Bias TRUE 0.70%0.20%0.12%0.11%± 5% of Span
Difference TRUE 0.35 0.1 0.025 0.025
Pass or Failed Invalid Run Passed Cal.Passed Cal.Passed Cal.Passed Cal.
CM - Up-scale Gas 24.75 24.70 9.93 10.45
SBi - Up-Scale Bias TRUE 0.70%0.60%1.47%0.11%
Difference TRUE 0.35 0.30 0.32 0.02
Pass or Failed Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal.
Raw Test Data Time Start Stop
Test Date:12/6/2023 SO2
SO2 NOX CO CO2 O2 NOX
16.3 1.13 3.1 15.8 CO
0.0% 32.4% 2.3% 14.5% 72.0% CO2/O2
Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100
Final Values SO2 NOX CO CO2 O2
CO - Low-Level 0.29 0.00 0.00 0.03 System Bias.
SBi - Zero Bias TRUE 0.64% 0.20% 0.12% 0.11%± 5% of Span
Difference TRUE 0.3 0.1 0.0 0.0
Pass or Invalid Run Passed Cal.Passed Cal.Passed Cal.Passed Cal.
CM - Up-scale Gas 24.89 24.72 9.83 10.30
SBi - Up-Scale Bias TRUE 0.42%0.55%1.89%0.57%
Difference TRUE 0.2 0.3 0.4 0.1
Pass or Invalid Run Passed Cal.Passed Cal.Passed Cal.Passed Cal.
Calibration Drift % of Span - D=ABS(SBf - SBi)
Low-Level Drift TRUE 0.06%0.00%0.00%0.00%Drift
Difference TRUE 0.0 0.0 0.0 0.0 3% of Span
Pass or Re-Calibrate Pass Pass Pass Pass
Up-scale Gas Drift TRUE 0.28% 0.04% 0.43% 0.45%
Difference TRUE 0.1 0.0 0.1 0.1
Pass or Re-Calibrate Pass Pass Pass Pass
Salt Lake Compressor Station Turbine Unit 2 High Flow & Moisture
As ft^2 Pbar Pq (static) Ps Avg. Ts F CO2 - FCO2 O2 N2+C Md Ms
56.250 25.78 0.00 25.78 3.10 15.61 81.29 29.12 29.12
Y Cp Vm cf Vlc AVG Tm F Vm std Vw std Bws S Bws #VALUE!
0.0000 0.00 0.999
Load - Megawatts
Avg. √∆P's Vs
(ft./sec.)Qsw scfh wet Qa acfm Qsd dscfh
Heat Input
Btu/hr.Low Mid High
108.7336011 Enter >X
3D Pitot #1 - Times
Date
Point No.∆P √∆P ts F tm F (in) tm F (out)
Final
Vf
Initial
Vi
1
2
3
4
5
6 Sum
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
NOTE
These cells scans for the appropriate
Cir. gas after the Cm
If this scan is incorrect change the
Cdir to the correct gas value.
Failed Bias Dialog
Failed Drift Dialog
Failed Cal Error Dialog
CO Calibration Gas
Failed Bias Dialog
Unit 2 high $1_RM 2, 2F, 2G, 2H, 3A, 6C, 7E, 10, _ 19 - RA (B_W(Modified Feb. 27, 2018)
Division of Air Quality Stack Test Review of
Kern River Gas Transmission Company
SO2 NOX CO CO2 O2 Salt Lake Compressor Station Turbine Unit 2 High
CS Calibration Span 50.25 50.14 21.59 22.02
Units ppm ppm ppm %%
CV - Cylinder Value:SO2 NOX CO CO2 O2
Low-Level 0.00 0.00 0.00 0.00
Mid-Level 25.23 25.32 9.91 10.21
High-Level 50.25 50.14 21.59 22.02
0 to 20% of Cal. Span 0.00%0.00%0.00%0.00%
40 to 60% of Cal. Span 50.2%50.5%45.9%46.4%
100% of Cal. Span 100.0%100.0%100.0%100.0%
Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration.
CMA 25.23 25.32 9.91 10.21
Calibration Error Test
Measured Concentration SO2 NOX CO CO2 O2
Low-Level -0.03 0.10 -0.03 0.00
Mid-Level 25.10 25.00 10.24 10.43
High-Level 50.22 49.98 21.57 22.00
Enter Up-scale Analyzer Response to be used during testing.
ACE Eq. 7E-1 25.10 25.00 10.24 10.43
Low-Level 0.06%0.20%0.12%0.00%
ppmdv Difference 0.031 0.1 0.025 0
Status Passed Cal. Passed Cal. Passed Cal.Passed Cal.
Mid-Level 0.26%0.64%1.54%0.98%
ppmdv Difference 0.132 0.32 0.333 0.215
Status Passed Cal. Passed Cal. Passed Cal.Passed Cal.
High-Level 0.07%0.31%0.10%0.09%
ppmdv Difference 0.035 0.157 0.021 0.02
Status Passed Cal. Passed Cal. Passed Cal.Passed Cal.
Pre-Test Sampling System Bias
Initial Values SO2 NOX CO CO2 O2
CO - Low-Level 0.29 0.00 0.00 0.03 System Bias.
SBi - Zero Bias TRUE 0.64%0.20%0.12%0.11%± 5% of Span
Difference TRUE 0.321 0.1 0.025 0.025
Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal.
CM - Up-scale Gas 24.89 24.72 9.83 10.30
SBi - Up-Scale Bias TRUE 0.42%0.55%1.89%0.57%
Difference TRUE 0.211 0.278 0.409 0.125
Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal.
Raw Test Data Time Start Stop
Test Date:12/6/2023 SO2
SO2 NOX CO CO2 O2 NOX
16.1 0.89 3.1 15.8 CO
0.0% 32.1% 1.8% 14.4% 71.6%CO2/O2
Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100
Final Values SO2 NOX CO CO2 O2
CO - Low-Level 0.17 0.00 0.00 0.03 System Bias.
SBi - Zero Bias TRUE 0.40% 0.20% 0.12% 0.11%± 5% of Span
Difference TRUE 0.2 0.1 0.0 0.0
Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal.
CM - Up-scale Gas 24.78 24.00 9.80 10.35
SBi - Up-Scale Bias TRUE 0.64%1.99%2.03%0.34%
Difference TRUE 0.3 1.0 0.4 0.1
Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal.
Calibration Drift % of Span - D=ABS(SBf - SBi)
Low-Level Drift TRUE 0.24%0.00%0.00%0.00%Response Spec.
Difference TRUE 0.1 0.0 0.0 0.0 3% of Span
Pass or Re-Calibrate Pass Pass Pass Pass
Up-scale Gas Drift TRUE 0.22% 1.44% 0.13% 0.23%
Difference TRUE 0.1 0.7 0.0 0.0
Pass or Re-Calibrate Pass Pass Pass Pass
Salt Lake Compressor Station Turbine Unit 2 High Flow & Moisture
As ft^2 Pbar Pq (static) Ps Avg. Ts F CO2 - FCO2 O2 N2+C Md Ms
56.25 25.78 0.00 25.78 3.10 15.59 81.31 29.12 29.12
Y Cp Vm cf Vlc AVG Tm F Vm std Vw std Bws S Bws
0.0000 #DIV/0!0.999
Load - Megawatts
Avg. √∆P's Vs Qsw scfh wet Qa acfm Qsd dscfh
Heat Input
Btu/hr.Low Mid High
108.7336011 Enter >X
3D Pitot #1 - Times
Date
Point No.∆P √∆P ts F tm F (in) tm F (out)
Final
Vf
Initial
Vi
1
2
3
4
5
6 Sum
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
Failed Bias Dialog
Failed Drift Dialog
Failed Cal Error Dialog
Failed Bias Dialog
Unit 2 high $1_RM 2, 2F, 2G, 2H, 3A, 6C, 7E, 10, _ 19 - RA (B_W(Modified Feb. 27, 2018)
Division of Air Quality Stack Test Review of
Kern River Gas Transmission Company
SO2 NOX CO CO2 O2 Salt Lake Compressor Station Turbine Unit 2 High
CS Calibration Span 50.25 50.14 21.59 22.02
Units ppm ppm ppm %%
CV - Cylinder Value:SO2 NOX CO CO2 O2
Low-Level 0.00 0.00 0.00 0.00
Mid-Level 25.23 25.32 9.91 10.21
High-Level 50.25 50.14 21.59 22.02
0 to 20% of Cal. Span 0.00%0.00%0.00%0.00%
40 to 60% of Cal. Span 50.2%50.5%45.9%46.4%
100% of Cal. Span 100.0%100.0%100.0%100.0%
Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration.
CMA 25.23 25.32 9.91 10.21
Calibration Error Test
Measured Concentration SO2 NOX CO CO2 O2
Low-Level -0.03 0.10 -0.03 0.00
Mid-Level 25.10 25.00 10.24 10.43
High-Level 50.22 49.98 21.57 22.00
Enter Up-scale Analyzer Response to be used during testing.
ACE Eq. 7E-1 25.10 25.00 10.24 10.43
Low-Level 0.06%0.20%0.12%0.00%
ppmv Difference 0.031 0.1 0.025 0
Status Passed Cal. Passed Cal. Passed Cal.Passed Cal.
Mid-Level 0.26%0.64%1.54%0.98%
ppmv Difference 0.132 0.32 0.333 0.215
Status Passed Cal. Passed Cal. Passed Cal.Passed Cal.
High-Level 0.07%0.31%0.10%0.09%
ppmv Difference 0.035 0.157 0.021 0.02
Status Passed Cal. Passed Cal. Passed Cal.Passed Cal.
Pre-Test Sampling System Bias
Initial Values SO2 NOX CO CO2 O2
CO - Low-Level 0.17 0.00 0.00 0.03 System Bias.
SBi - Zero Bias TRUE 0.40%0.20%0.12%0.11%± 5% of Span
Difference TRUE 0.201 0.1 0.025 0.025
Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal.
CM - Up-scale Gas 24.78 24.00 9.80 10.35
SBi - Up-Scale Bias TRUE 0.64%1.99%2.03%0.34%
Difference TRUE 0.321 1 0.438 0.075
Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal.
Raw Test Data Time Start Stop
Test Date:12/6/2023 SO2
SO2 NOX CO CO2 O2 NOX
16.0 0.88 3.1 15.7 CO
0.0% 31.8% 1.7% 14.4% 71.5%CO2/O2
Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100
Final Values SO2 NOX CO CO2 O2
CO - Low-Level 0.14 -0.10 0.00 0.03 System Bias.
SBi - Zero Bias TRUE 0.34% 0.40% 0.12% 0.11%± 5% of Span
Difference TRUE 0.2 0.2 0.0 0.0
Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal.
CM - Up-scale Gas 24.45 23.98 9.86 10.48
SBi - Up-Scale Bias TRUE 1.30%2.04%1.79%0.26%
Difference TRUE 0.7 1.0 0.4 0.1
Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal.
Calibration Drift % of Span - D=ABS(SBf - SBi)
Low-Level Drift TRUE 0.06%0.20%0.00%0.00%Response Spec.
Difference TRUE 0.0 0.1 0.0 0.0 3% of Span
Pass or Re-Calibrate Pass Pass Pass Pass
Up-scale Gas Drift TRUE 0.66% 0.04% 0.24% 0.08%
Difference TRUE 0.3 0.0 0.1 0.1
Pass or Re-Calibrate Pass Pass Pass Pass
Salt Lake Compressor Station Turbine Unit 2 High Flow & Moisture
As ft^2 Pbar Pq (static) Ps Avg. Ts F CO2 - FCO2 O2 N2+C Md Ms
56.25 25.77 0.00 25.77 3.10 15.45 81.45 29.11 29.11
Y Cp Vm cf Vlc AVG Tm F Vm std Vw std Bws S Bws
0.0000 #DIV/0!0.999
Load - Megawatts
Avg. √∆P's Vs Qsw scfh wet Qa acfm Qsd dscfh
Heat Input
Btu/hr.Low Mid High
107.8914789 Enter >X
3D Pitot #1 - Times
Date
Point No.∆P √∆P ts F tm F (in) tm F (out)
Final
Vf
Initial
Vi
1
2
3
4
5
6 Sum
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
Failed Bias Dialog
Failed Cal Error Dialog
Failed Drift Dialog
Failed Bias Dialog
Unit 2 mid high $1_RM 2, 2F, 2G, 2H, 3A, 6C, 7E, 10, _ 19 - RA (B_W(Modified Feb. 27, 2018)
Reference Methods 2, 3A, 6C, 7E, 10, & 19
Source Information
Company Name Kern River Gas Transmission Company
Company Contact:Denise Kohtala
Contact Phone No.801-937-6347
Stack Designation:Salt Lake Compressor Station Unit 2 Mid-High
Test & Review Dates
Test Date:12/6/2023 &
Review Date: 2/5/2024
Observer:Not observed
Reviewer:Paul Bushman
Emission Limits Emission Rates
SO2 NOX CO SO2 NOX CO
lbs./MMBtu
lbs./hr. 9.5 10.4 6.116 0.222
ppm 25.0 50.00 16.657 0.997
ppm @ ISO
%O2 Correction as a whole #15.00 15.00
Test Information
Equivalent
Diameter (in.)As ft^2 Y Dl H @ Cp Pbar Pq (static)
Ps
Stack Pressure
90.00 56.250 0
10
Contractor Information
Contact:Jeffery Daniels
Contracting Company: TRC Environmental Corporation
Address: 400 Corporate Circle, Suite P, Golden CO 80401
Phone No.: 630-880-4754
Project No.:
8634
Division of Air Quality
Instrumental Reference Methods - Gaseous Measurements
Rectangular
Method 19 - F factors for Coal, Oil, and Gas
Fd Fw Fc
dscf/MMBtu wscf/MMBtu scf/MMBtu Diluent
F factor used
O2
CO2
Anthracite 2
Bituminous 2
Lignite
Natural
Propane
Butane
10100
COAL
OIL
GAS
9780
9860
9190
8710
8710
8710
10540
10640
11950
320
10610
10200
10390
1970
1800
1910
1420
1040
1190
1250
Wet CEM
Correct For O2
CO2 Interference w/CO
Yes
Yes
Yes
Unit 2 mid high $1_RM 2, 2F, 2G, 2H, 3A, 6C, 7E, 10, _ 19 - RA (B_W(Modified Feb. 27, 2018)
Calibration Error Test
Test Date December 6, 2023 O2
CS - Cal. Span 22.02
Units %
Cylinder No. Expiration
Date Cal. Gas CV- Certified
Concentration
CDir or CS -
Measured
Concentration
Difference
ACE Eq. 7E-1
Analyzer Cal.
Error
Status
Low-level 0.00 0.00 0.00 0.00%Passed Cal.
SG9166178BAL 07/18/31 Mid-level 10.21 10.43 0.22 0.98%Passed Cal.
CC58424 07/30/27 High-level 22.02 22.00 0.02 0.09%Passed Cal.
% of Span Sec. 8.2.1 Cal Gas Verification
0 to 20% of CS - Cal. Span Low-Level 0.00%
40 to 60% of Cal. Span Mid-level 46.37%
100% of Cal. Span High-level 100.00%
Test Date December 6, 2023 CO2
CS - Cal. Span 21.59
Units %
Cylinder
No.
Expiration
Date Cal. Gas CV- Certified
Concentration
CDir or CS -
Measured
Concentration
Difference
ACE Eq. 7E-1
Analyzer Cal.
Error
Status
Low-level 0.00 -0.03 0.03 0.116%Passed Cal.
SG9166178BAL 07/18/31 Mid-level 9.91 10.24 0.33 1.542%Passed Cal.
CC58424 07/30/27 High-level 21.59 21.57 0.02 0.097%Passed Cal.
% of Span Sec. 8.2.1 Cal Gas Verification
0 to 20% of Cal. Span Low-Level 0.00%
40 to 60% of Cal. Span Mid-level 45.90%
100% of Cal. Span High-level 100.00%
Test Date SO2
CS - Cal. Span
Units ppm
Cylinder
No.
Expiration
Date Cal. Gas CV- Certified
Concentration
CDir or CS -
Measured
Concentration
Difference
ACE Eq. 7E-1
Analyzer Cal.
Error
Status
Low-level
Mid-level
High-level
% of Span Sec. 8.2.1 Cal Gas Verification
0 to 20% of Cal. Span Low-Level
40 to 60% of Cal. Span Mid-level
100% of Cal. Span High-level
Test Date December 6, 2023 NOx
CS - Cal. Span 50.25
Units ppm
Cylinder
No.
Expiration
Date Cal. Gas CV- Certified
Concentration
CDir or CS -
Measured
Concentration
Difference
ACE Eq. 7E-1
Analyzer Cal.
Error
Status
Low-level 0.00 -0.03 0.03 0.062%Passed Cal.
CC365571 10/31/26 Mid-level 25.23 25.10 0.13 0.263%Passed Cal.
EB0119277 05/04/28 High-level 50.25 50.22 0.03 0.070%Passed Cal.
% of Span Sec. 8.2.1 Cal Gas Verification
0 to 20% of Cal. Span Low-Level 0.00%
40 to 60% of Cal. Span Mid-level 50.21%
100% of Cal. Span High-level 100.00%
Test Date December 6, 2023 CO
10.38 CS - Cal. Span 50.14
50 Units ppm
Cylinder
No.
Expiration
Date Cal. Gas CV- Certified
Concentration
CDir or CS -
Measured
Concentration
Difference
ACE Eq. 7E-1
Analyzer Cal.
Error
Status
Low-level 0.00 0.10 0.10 0.199%Passed Cal.
CC365571 10/31/26 Mid-level 25.32 25.00 0.32 0.638%Passed Cal.
EB0119277 05/04/28 High-level 50.14 49.98 0.16 0.313%Passed Cal.
% of Span Sec. 8.2.1 Cal Gas Verification
0 to 20% of Cal. Span Low-Level 0.00%
40 to 60% of Cal. Span Mid-level 50.50%
100% of Cal. Span High-level 100.00%
Valid Cal Gas
Valid Cal Gas
Valid Cal Gas
Valid Cal Gas
Valid Cal Gas
Valid Cal Gas
Valid Cal Gas
Valid Cal Gas
Unit 2 mid high $1_RM 2, 2F, 2G, 2H, 3A, 6C, 7E, 10, _ 19 - RA (B_W(Modified Feb. 27, 2018)
Division of Air Quality Stack Test Review of
Kern River Gas Transmission Company
SO2 NOX CO CO2 O2 Salt Lake Compressor Station Unit 2 Mid-High
CS Calibration Span 50.25 50.14 21.59 22.02
Units ppm ppm ppm %%Unprotected
CV - Cylinder Value: SO2 NOX CO CO2 O2
Low-Level 0.00 0.00 0.00 0.00
Mid-Level 25.23 25.32 9.91 10.21
High-Level 50.25 50.14 21.59 22.02
0 to 20% of Cal. Span 0.00%0.00%0.00%0.00%
40 to 60% of Cal. Span 50.2%50.5%45.9%46.4%
100% of Cal. Span 100.0%100.0%100.0%100.0%
Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration.
CDir CMA 25.23 25.32 9.91 10.21
Calibration Error Test
Cs - Measured Concentration SO2 NOX CO CO2 O2
Low-Level -0.03 0.10 -0.03 0.00
Mid-Level 25.10 25.00 10.24 10.43
High-Level 50.22 49.98 21.57 22.00
Enter Up-scale Analyzer Response to be used during testing.
ACE Eq. 7E-1 25.10 25.00 10.24 10.43
Low-Level 0.06%0.20%0.12%0.00%
ppmdv Difference 0.031 0.1 0.025 0
Status Passed Cal. Passed Cal. Passed Cal.Passed Cal.
Mid-Level 0.26%0.64%1.54%0.98%
ppmdv Difference 0.132 0.32 0.333 0.215
Status Passed Cal. Passed Cal. Passed Cal.Passed Cal.
High-Level 0.07%0.31%0.10%0.09%
ppmdv Difference 0.035 0.157 0.021 0.02
Status Passed Cal. Passed Cal. Passed Cal.Passed Cal.
Pre-Test Sampling System Bias
Initial Values SO2 NOX CO CO2 O2
CO - Low-Level 0.14 0.10 -0.03 0.00 System Bias.
SBi - Zero Bias TRUE 0.34%0.00%0.00%0.00%± 5% of Span
Difference TRUE 0.171 0 0 0
Pass or Failed Invalid Run Passed Cal.Passed Cal.Passed Cal.Passed Cal.
CM - Up-scale Gas 24.45 24.14 9.86 10.48
SBi - Up-Scale Bias TRUE 1.30%1.72%1.79%0.26%
Difference TRUE 0.65 0.86 0.39 0.06
Pass or Failed Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal.
Raw Test Data Time Start Stop
Test Date:12/6/2023 SO2
SO2 NOX CO CO2 O2 NOX
12.5 0.74 3.0 16.2 CO
0.0% 24.8% 1.5% 13.9% 73.4% CO2/O2
Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100
Final Values SO2 NOX CO CO2 O2
CO - Low-Level 0.20 0.00 0.00 0.03 System Bias.
SBi - Zero Bias TRUE 0.46% 0.20% 0.12% 0.11%± 5% of Span
Difference TRUE 0.2 0.1 0.0 0.0
Pass or Invalid Run Passed Cal.Passed Cal.Passed Cal.Passed Cal.
CM - Up-scale Gas 24.42 24.14 9.68 10.28
SBi - Up-Scale Bias TRUE 1.36%1.71%2.63%0.68%
Difference TRUE 0.7 0.9 0.6 0.2
Pass or Invalid Run Passed Cal.Passed Cal.Passed Cal.Passed Cal.
Calibration Drift % of Span - D=ABS(SBf - SBi)
Low-Level Drift TRUE 0.12%0.20%0.12%0.11%Drift
Difference TRUE 0.1 0.1 0.0 0.0 3% of Span
Pass or Re-Calibrate Pass Pass Pass Pass
Up-scale Gas Drift TRUE 0.06% 0.00% 0.84% 0.42%
Difference TRUE 0.0 0.0 0.2 0.2
Pass or Re-Calibrate Pass Pass Pass Pass
Salt Lake Compressor Station Unit 2 Mid-High Flow & Moisture
As ft^2 Pbar Pq (static) Ps Avg. Ts F CO2 - FCO2 O2 N2+C Md Ms
56.250 25.78 0.00 25.78 3.01 15.90 81.10 29.12 29.12
Y Cp Vm cf Vlc AVG Tm F Vm std Vw std Bws S Bws #VALUE!
0.0000 0.00 0.999
Load - Megawatts
Avg. √∆P's Vs
(ft./sec.)Qsw scfh wet Qa acfm Qsd dscfh
Heat Input
Btu/hr.Low Mid High
97.36550021 Enter >X
3D Pitot #1 - Times
Date
Point No.∆P √∆P ts F tm F (in) tm F (out)
Final
Vf
Initial
Vi
1
2
3
4
5
6 Sum
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
NOTE
These cells scans for the appropriate
Cir. gas after the Cm
If this scan is incorrect change the
Cdir to the correct gas value.
Failed Bias Dialog
Failed Drift Dialog
Failed Cal Error Dialog
CO Calibration Gas
Failed Bias Dialog
Unit 2 mid high $1_RM 2, 2F, 2G, 2H, 3A, 6C, 7E, 10, _ 19 - RA (B_W(Modified Feb. 27, 2018)
Division of Air Quality Stack Test Review of
Kern River Gas Transmission Company
SO2 NOX CO CO2 O2 Salt Lake Compressor Station Unit 2 Mid-High
CS Calibration Span 50.25 50.14 21.59 22.02
Units ppm ppm ppm %%
CV - Cylinder Value:SO2 NOX CO CO2 O2
Low-Level 0.00 0.00 0.00 0.00
Mid-Level 25.23 25.32 9.91 10.21
High-Level 50.25 50.14 21.59 22.02
0 to 20% of Cal. Span 0.00%0.00%0.00%0.00%
40 to 60% of Cal. Span 50.2%50.5%45.9%46.4%
100% of Cal. Span 100.0%100.0%100.0%100.0%
Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration.
CMA 25.23 25.32 9.91 10.21
Calibration Error Test
Measured Concentration SO2 NOX CO CO2 O2
Low-Level -0.03 0.10 -0.03 0.00
Mid-Level 25.10 25.00 10.24 10.43
High-Level 50.22 49.98 21.57 22.00
Enter Up-scale Analyzer Response to be used during testing.
ACE Eq. 7E-1 25.10 25.00 10.24 10.43
Low-Level 0.06%0.20%0.12%0.00%
ppmdv Difference 0.031 0.1 0.025 0
Status Passed Cal. Passed Cal. Passed Cal.Passed Cal.
Mid-Level 0.26%0.64%1.54%0.98%
ppmdv Difference 0.132 0.32 0.333 0.215
Status Passed Cal. Passed Cal. Passed Cal.Passed Cal.
High-Level 0.07%0.31%0.10%0.09%
ppmdv Difference 0.035 0.157 0.021 0.02
Status Passed Cal. Passed Cal. Passed Cal.Passed Cal.
Pre-Test Sampling System Bias
Initial Values SO2 NOX CO CO2 O2
CO - Low-Level 0.14 -0.10 0.00 0.03 System Bias.
SBi - Zero Bias TRUE 0.34%0.40%0.12%0.11%± 5% of Span
Difference TRUE 0.171 0.2 0.025 0.025
Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal.
CM - Up-scale Gas 24.45 23.98 9.86 10.48
SBi - Up-Scale Bias TRUE 1.30%2.04%1.79%0.26%
Difference TRUE 0.651 1.022 0.386 0.058
Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal.
Raw Test Data Time Start Stop
Test Date:12/6/2023 SO2
SO2 NOX CO CO2 O2 NOX
14.2 0.78 3.0 16.5 CO
0.0% 28.2% 1.6% 14.0% 75.1%CO2/O2
Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100
Final Values SO2 NOX CO CO2 O2
CO - Low-Level 0.20 0.00 0.00 0.03 System Bias.
SBi - Zero Bias TRUE 0.46% 0.20% 0.12% 0.11%± 5% of Span
Difference TRUE 0.2 0.1 0.0 0.0
Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal.
CM - Up-scale Gas 24.42 24.14 9.68 10.28
SBi - Up-Scale Bias TRUE 1.36%1.71%2.63%0.68%
Difference TRUE 0.7 0.9 0.6 0.2
Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal.
Calibration Drift % of Span - D=ABS(SBf - SBi)
Low-Level Drift TRUE 0.12%0.20%0.00%0.00%Response Spec.
Difference TRUE 0.1 0.1 0.0 0.0 3% of Span
Pass or Re-Calibrate Pass Pass Pass Pass
Up-scale Gas Drift TRUE 0.06% 0.33% 0.84% 0.42%
Difference TRUE 0.0 0.2 0.2 0.2
Pass or Re-Calibrate Pass Pass Pass Pass
Salt Lake Compressor Station Unit 2 Mid-High Flow & Moisture
As ft^2 Pbar Pq (static) Ps Avg. Ts F CO2 - FCO2 O2 N2+C Md Ms
56.25 25.78 0.00 25.78 3.03 16.28 80.69 29.14 29.14
Y Cp Vm cf Vlc AVG Tm F Vm std Vw std Bws S Bws
0.0000 #DIV/0!0.999
Load - Megawatts
Avg. √∆P's Vs Qsw scfh wet Qa acfm Qsd dscfh
Heat Input
Btu/hr.Low Mid High
101.7864202 Enter >X
3D Pitot #1 - Times
Date
Point No.∆P √∆P ts F tm F (in) tm F (out)
Final
Vf
Initial
Vi
1
2
3
4
5
6 Sum
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
Failed Bias Dialog
Failed Drift Dialog
Failed Cal Error Dialog
Failed Bias Dialog
Unit 2 mid high $1_RM 2, 2F, 2G, 2H, 3A, 6C, 7E, 10, _ 19 - RA (B_W(Modified Feb. 27, 2018)
Division of Air Quality Stack Test Review of
Kern River Gas Transmission Company
SO2 NOX CO CO2 O2 Salt Lake Compressor Station Unit 2 Mid-High
CS Calibration Span 50.25 50.14 21.59 22.02
Units ppm ppm ppm %%
CV - Cylinder Value:SO2 NOX CO CO2 O2
Low-Level 0.00 0.00 0.00 0.00
Mid-Level 25.23 25.32 9.91 10.21
High-Level 50.25 50.14 21.59 22.02
0 to 20% of Cal. Span 0.00%0.00%0.00%0.00%
40 to 60% of Cal. Span 50.2%50.5%45.9%46.4%
100% of Cal. Span 100.0%100.0%100.0%100.0%
Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration.
CMA 25.23 25.32 9.91 10.21
Calibration Error Test
Measured Concentration SO2 NOX CO CO2 O2
Low-Level -0.03 0.10 -0.03 0.00
Mid-Level 25.10 25.00 10.24 10.43
High-Level 50.22 49.98 21.57 22.00
Enter Up-scale Analyzer Response to be used during testing.
ACE Eq. 7E-1 25.10 25.00 10.24 10.43
Low-Level 0.06%0.20%0.12%0.00%
ppmv Difference 0.031 0.1 0.025 15
Status Passed Cal. Passed Cal. Passed Cal.Passed Cal.
Mid-Level 0.26%0.64%1.54%0.98%
ppmv Difference 0.132 0.32 0.333 0.215
Status Passed Cal. Passed Cal. Passed Cal.Passed Cal.
High-Level 0.07%0.31%0.10%0.09%
ppmv Difference 0.035 0.157 0.021 0.02
Status Passed Cal. Passed Cal. Passed Cal.Passed Cal.
Pre-Test Sampling System Bias
Initial Values SO2 NOX CO CO2 O2
CO - Low-Level 0.14 -0.10 0.00 0.03 System Bias.
SBi - Zero Bias TRUE 0.34%0.40%0.12%0.11%± 5% of Span
Difference TRUE 0.171 0.2 0.025 0.025
Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal.
CM - Up-scale Gas 24.45 23.98 9.86 10.48
SBi - Up-Scale Bias TRUE 1.30%2.04%1.79%0.26%
Difference TRUE 0.651 1.022 0.386 0.058
Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal.
Raw Test Data Time Start Stop
Test Date:12/6/2023 SO2
SO2 NOX CO CO2 O2 NOX
14.2 0.81 3.0 15.9 CO
0.0% 28.2% 1.6% 13.9% 72.0%CO2/O2
Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100
Final Values SO2 NOX CO CO2 O2
CO - Low-Level 0.20 0.00 0.00 0.03 System Bias.
SBi - Zero Bias TRUE 0.46% 0.20% 0.12% 0.11%± 5% of Span
Difference TRUE 0.2 0.1 0.0 0.0
Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal.
CM - Up-scale Gas 24.42 24.14 9.68 10.28
SBi - Up-Scale Bias TRUE 1.36%1.71%2.63%0.68%
Difference TRUE 0.7 0.9 0.6 0.2
Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal.
Calibration Drift % of Span - D=ABS(SBf - SBi)
Low-Level Drift TRUE 0.12%0.20%0.00%0.00%Response Spec.
Difference TRUE 0.1 0.1 0.0 0.0 3% of Span
Pass or Re-Calibrate Pass Pass Pass Pass
Up-scale Gas Drift TRUE 0.06% 0.33% 0.84% 0.42%
Difference TRUE 0.0 0.2 0.2 0.2
Pass or Re-Calibrate Pass Pass Pass Pass
Salt Lake Compressor Station Unit 2 Mid-High Flow & Moisture
As ft^2 Pbar Pq (static) Ps Avg. Ts F CO2 - FCO2 O2 N2+C Md Ms
56.25 25.77 0.00 25.77 3.00 15.61 81.40 29.10 29.10
Y Cp Vm cf Vlc AVG Tm F Vm std Vw std Bws S Bws
0.0000 #DIV/0!0.999
Load - Megawatts
Avg. √∆P's Vs Qsw scfh wet Qa acfm Qsd dscfh
Heat Input
Btu/hr.Low Mid High
101.99694 Enter >X
3D Pitot #1 - Times
Date
Point No.∆P √∆P ts F tm F (in) tm F (out)
Final
Vf
Initial
Vi
1
2
3
4
5
6 Sum
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
Failed Bias Dialog
Failed Cal Error Dialog
Failed Drift Dialog
Failed Bias Dialog
Unit 2 mid low $1_RM 2, 2F, 2G, 2H, 3A, 6C, 7E, 10, _ 19 - RA (B_W(Modified Feb. 27, 2018)
Reference Methods 2, 3A, 6C, 7E, 10, & 19
Source Information
Company Name Kern River Gas Transmission Company
Company Contact:Denise Kohtala
Contact Phone No.801-937-6347
Stack Designation:Salt Lake Compressor Station Unit 2 Mid-Low
Test & Review Dates
Test Date:12/6/2023 &
Review Date: 2/5/2024
Observer:Not observed
Reviewer:Paul Bushman
Emission Limits Emission Rates
SO2 NOX CO SO2 NOX CO
lbs./MMBtu
lbs./hr. 9.5 10.4 6.503 0.205
ppm 25.0 50.00 18.673 0.970
ppm @ ISO
%O2 Correction as a whole #15.00 15.00
Test Information
Equivalent
Diameter (in.)As ft^2 Y Dl H @ Cp Pbar Pq (static)
Ps
Stack Pressure
90.00 56.250 0
10
Contractor Information
Contact:Jeffery Daniels
Contracting Company: TRC Environmental Corporation
Address: 400 Corporate Circle, Suite P, Golden CO 80401
Phone No.: 630-880-4754
Project No.:
8634
Division of Air Quality
Instrumental Reference Methods - Gaseous Measurements
Rectangular
Method 19 - F factors for Coal, Oil, and Gas
Fd Fw Fc
dscf/MMBtu wscf/MMBtu scf/MMBtu Diluent
F factor used
O2
CO2
Anthracite 2
Bituminous 2
Lignite
Natural
Propane
Butane
10100
COAL
OIL
GAS
9780
9860
9190
8710
8710
8710
10540
10640
11950
320
10610
10200
10390
1970
1800
1910
1420
1040
1190
1250
Wet CEM
Correct For O2
CO2 Interference w/CO
Yes
Yes
Yes
Unit 2 mid low $1_RM 2, 2F, 2G, 2H, 3A, 6C, 7E, 10, _ 19 - RA (B_W(Modified Feb. 27, 2018)
Calibration Error Test
Test Date December 6, 2023 O2
CS - Cal. Span 22.02
Units %
Cylinder No. Expiration
Date Cal. Gas CV- Certified
Concentration
CDir or CS -
Measured
Concentration
Difference
ACE Eq. 7E-1
Analyzer Cal.
Error
Status
Low-level 0.00 0.00 0.00 0.00%Passed Cal.
SG9166178BAL 07/18/31 Mid-level 10.21 10.43 0.22 0.98%Passed Cal.
CC58424 07/30/27 High-level 22.02 22.00 0.02 0.09%Passed Cal.
% of Span Sec. 8.2.1 Cal Gas Verification
0 to 20% of CS - Cal. Span Low-Level 0.00%
40 to 60% of Cal. Span Mid-level 46.37%
100% of Cal. Span High-level 100.00%
Test Date December 6, 2023 CO2
CS - Cal. Span 21.59
Units %
Cylinder
No.
Expiration
Date Cal. Gas CV- Certified
Concentration
CDir or CS -
Measured
Concentration
Difference
ACE Eq. 7E-1
Analyzer Cal.
Error
Status
Low-level 0.00 -0.03 0.03 0.116%Passed Cal.
SG9166178BAL 07/18/31 Mid-level 9.91 10.24 0.33 1.542%Passed Cal.
CC58424 07/30/27 High-level 21.59 21.57 0.02 0.097%Passed Cal.
% of Span Sec. 8.2.1 Cal Gas Verification
0 to 20% of Cal. Span Low-Level 0.00%
40 to 60% of Cal. Span Mid-level 45.90%
100% of Cal. Span High-level 100.00%
Test Date SO2
CS - Cal. Span
Units ppm
Cylinder
No.
Expiration
Date Cal. Gas CV- Certified
Concentration
CDir or CS -
Measured
Concentration
Difference
ACE Eq. 7E-1
Analyzer Cal.
Error
Status
Low-level
Mid-level
High-level
% of Span Sec. 8.2.1 Cal Gas Verification
0 to 20% of Cal. Span Low-Level
40 to 60% of Cal. Span Mid-level
100% of Cal. Span High-level
Test Date December 6, 2023 NOx
CS - Cal. Span 50.25
Units ppm
Cylinder
No.
Expiration
Date Cal. Gas CV- Certified
Concentration
CDir or CS -
Measured
Concentration
Difference
ACE Eq. 7E-1
Analyzer Cal.
Error
Status
Low-level 0.00 -0.03 0.03 0.062%Passed Cal.
CC365571 10/31/26 Mid-level 25.23 25.10 0.13 0.263%Passed Cal.
EB0119277 05/04/28 High-level 50.25 50.22 0.03 0.070%Passed Cal.
% of Span Sec. 8.2.1 Cal Gas Verification
0 to 20% of Cal. Span Low-Level 0.00%
40 to 60% of Cal. Span Mid-level 50.21%
100% of Cal. Span High-level 100.00%
Test Date December 6, 2023 CO
10.38 CS - Cal. Span 50.14
50 Units ppm
Cylinder
No.
Expiration
Date Cal. Gas CV- Certified
Concentration
CDir or CS -
Measured
Concentration
Difference
ACE Eq. 7E-1
Analyzer Cal.
Error
Status
Low-level 0.00 0.10 0.10 0.199%Passed Cal.
CC365571 10/31/26 Mid-level 25.32 25.00 0.32 0.638%Passed Cal.
EB0119277 05/04/28 High-level 50.14 49.98 0.16 0.313%Passed Cal.
% of Span Sec. 8.2.1 Cal Gas Verification
0 to 20% of Cal. Span Low-Level 0.00%
40 to 60% of Cal. Span Mid-level 50.50%
100% of Cal. Span High-level 100.00%
Valid Cal Gas
Valid Cal Gas
Valid Cal Gas
Valid Cal Gas
Valid Cal Gas
Valid Cal Gas
Valid Cal Gas
Valid Cal Gas
Unit 2 mid low $1_RM 2, 2F, 2G, 2H, 3A, 6C, 7E, 10, _ 19 - RA (B_W(Modified Feb. 27, 2018)
Division of Air Quality Stack Test Review of
Kern River Gas Transmission Company
SO2 NOX CO CO2 O2 Salt Lake Compressor Station Unit 2 Mid-Low
CS Calibration Span 50.25 50.14 21.59 22.02
Units ppm ppm ppm %%Unprotected
CV - Cylinder Value: SO2 NOX CO CO2 O2
Low-Level 0.00 0.00 0.00 0.00
Mid-Level 25.23 25.32 9.91 10.21
High-Level 50.25 50.14 21.59 22.02
0 to 20% of Cal. Span 0.00%0.00%0.00%0.00%
40 to 60% of Cal. Span 50.2%50.5%45.9%46.4%
100% of Cal. Span 100.0%100.0%100.0%100.0%
Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration.
CDir CMA 25.23 25.32 9.91 10.21
Calibration Error Test
Cs - Measured Concentration SO2 NOX CO CO2 O2
Low-Level -0.03 0.10 -0.03 0.00
Mid-Level 25.10 25.00 10.24 10.43
High-Level 50.22 49.98 21.57 22.00
Enter Up-scale Analyzer Response to be used during testing.
ACE Eq. 7E-1 25.10 25.00 10.24 10.43
Low-Level 0.06%0.20%0.12%0.00%
ppmdv Difference 0.031 0.1 0.025 0
Status Passed Cal. Passed Cal. Passed Cal.Passed Cal.
Mid-Level 0.26%0.64%1.54%0.98%
ppmdv Difference 0.132 0.32 0.333 0.215
Status Passed Cal. Passed Cal. Passed Cal.Passed Cal.
High-Level 0.07%0.31%0.10%0.09%
ppmdv Difference 0.035 0.157 0.021 0.02
Status Passed Cal. Passed Cal. Passed Cal.Passed Cal.
Pre-Test Sampling System Bias
Initial Values SO2 NOX CO CO2 O2
CO - Low-Level 0.20 0.00 0.00 0.03 System Bias.
SBi - Zero Bias TRUE 0.46%0.20%0.12%0.11%± 5% of Span
Difference TRUE 0.231 0.1 0.025 0.025
Pass or Failed Invalid Run Passed Cal.Passed Cal.Passed Cal.Passed Cal.
CM - Up-scale Gas 24.42 24.14 9.68 10.28
SBi - Up-Scale Bias TRUE 1.36%1.71%2.63%0.68%
Difference TRUE 0.68 0.86 0.57 0.15
Pass or Failed Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal.
Raw Test Data Time Start Stop
Test Date:12/6/2023 SO2
SO2 NOX CO CO2 O2 NOX
16.0 0.71 3.0 15.9 CO
0.0% 31.9% 1.4% 13.8% 72.0% CO2/O2
Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100
Final Values SO2 NOX CO CO2 O2
CO - Low-Level 0.41 -0.10 0.05 0.38 System Bias.
SBi - Zero Bias TRUE 0.88% 0.40% 0.35% 1.70%± 5% of Span
Difference TRUE 0.4 0.2 0.1 0.4
Pass or Invalid Run Passed Cal.Passed Cal.Passed Cal.Passed Cal.
CM - Up-scale Gas 24.57 24.04 9.28 10.45
SBi - Up-Scale Bias TRUE 1.06%1.92%4.47%0.11%
Difference TRUE 0.5 1.0 1.0 0.0
Pass or Invalid Run Passed Cal.Passed Cal.Passed Cal.Passed Cal.
Calibration Drift % of Span - D=ABS(SBf - SBi)
Low-Level Drift TRUE 0.42%0.20%0.23%1.59%Drift
Difference TRUE 0.2 0.1 0.1 0.4 3% of Span
Pass or Re-Calibrate Pass Pass Pass Pass
Up-scale Gas Drift TRUE 0.30% 0.21% 1.84% 0.57%
Difference TRUE 0.1 0.1 0.4 0.2
Pass or Re-Calibrate Pass Pass Pass Pass
Salt Lake Compressor Station Unit 2 Mid-Low Flow & Moisture
As ft^2 Pbar Pq (static) Ps Avg. Ts F CO2 - FCO2 O2 N2+C Md Ms
56.250 25.78 0.00 25.78 2.98 15.73 81.29 29.11 29.11
Y Cp Vm cf Vlc AVG Tm F Vm std Vw std Bws S Bws #VALUE!
0.0000 0.00 0.999
Load - Megawatts
Avg. √∆P's Vs
(ft./sec.)Qsw scfh wet Qa acfm Qsd dscfh
Heat Input
Btu/hr.Low Mid High
95.04978 Enter >X
3D Pitot #1 - Times
Date
Point No.∆P √∆P ts F tm F (in) tm F (out)
Final
Vf
Initial
Vi
1
2
3
4
5
6 Sum
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
NOTE
These cells scans for the appropriate
Cir. gas after the Cm
If this scan is incorrect change the
Cdir to the correct gas value.
Failed Bias Dialog
Failed Drift Dialog
Failed Cal Error Dialog
CO Calibration Gas
Failed Bias Dialog
Unit 2 mid low $1_RM 2, 2F, 2G, 2H, 3A, 6C, 7E, 10, _ 19 - RA (B_W(Modified Feb. 27, 2018)
Division of Air Quality Stack Test Review of
Kern River Gas Transmission Company
SO2 NOX CO CO2 O2 Salt Lake Compressor Station Unit 2 Mid-Low
CS Calibration Span 50.25 50.14 21.59 22.02
Units ppm ppm ppm %%
CV - Cylinder Value:SO2 NOX CO CO2 O2
Low-Level 0.00 0.00 0.00 0.00
Mid-Level 25.23 25.32 9.91 10.21
High-Level 50.25 50.14 21.59 22.02
0 to 20% of Cal. Span 0.00%0.00%0.00%0.00%
40 to 60% of Cal. Span 50.2%50.5%45.9%46.4%
100% of Cal. Span 100.0%100.0%100.0%100.0%
Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration.
CMA 25.23 25.32 9.91 10.21
Calibration Error Test
Measured Concentration SO2 NOX CO CO2 O2
Low-Level -0.03 0.10 -0.03 0.00
Mid-Level 25.10 25.00 10.24 10.43
High-Level 50.22 49.98 21.57 22.00
Enter Up-scale Analyzer Response to be used during testing.
ACE Eq. 7E-1 25.10 25.00 10.24 10.43
Low-Level 0.06%0.20%0.12%0.00%
ppmdv Difference 0.031 0.1 0.025 0
Status Passed Cal. Passed Cal. Passed Cal.Passed Cal.
Mid-Level 0.26%0.64%1.54%0.98%
ppmdv Difference 0.132 0.32 0.333 0.215
Status Passed Cal. Passed Cal. Passed Cal.Passed Cal.
High-Level 0.07%0.31%0.10%0.09%
ppmdv Difference 0.035 0.157 0.021 0.02
Status Passed Cal. Passed Cal. Passed Cal.Passed Cal.
Pre-Test Sampling System Bias
Initial Values SO2 NOX CO CO2 O2
CO - Low-Level 0.20 0.00 0.00 0.03 System Bias.
SBi - Zero Bias TRUE 0.46%0.20%0.12%0.11%± 5% of Span
Difference TRUE 0.231 0.1 0.025 0.025
Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal.
CM - Up-scale Gas 24.42 24.14 9.68 10.28
SBi - Up-Scale Bias TRUE 1.36%1.71%2.63%0.68%
Difference TRUE 0.681 0.858 0.567 0.15
Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal.
Raw Test Data Time Start Stop
Test Date:12/6/2023 SO2
SO2 NOX CO CO2 O2 NOX
16.1 0.90 3.0 15.8 CO
0.0% 32.1% 1.8% 13.9% 71.9%CO2/O2
Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100
Final Values SO2 NOX CO CO2 O2
CO - Low-Level 0.41 -0.10 0.05 0.38 System Bias.
SBi - Zero Bias TRUE 0.88% 0.40% 0.35% 1.70%± 5% of Span
Difference TRUE 0.4 0.2 0.1 0.4
Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal.
CM - Up-scale Gas 24.57 24.04 9.28 10.45
SBi - Up-Scale Bias TRUE 1.06%1.92%4.47%0.11%
Difference TRUE 0.5 1.0 1.0 0.0
Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal.
Calibration Drift % of Span - D=ABS(SBf - SBi)
Low-Level Drift TRUE 0.42%0.20%0.23%1.59%Response Spec.
Difference TRUE 0.2 0.1 0.1 0.4 3% of Span
Pass or Re-Calibrate Pass Pass Pass Pass
Up-scale Gas Drift TRUE 0.30% 0.21% 1.84% 0.57%
Difference TRUE 0.1 0.1 0.4 0.2
Pass or Re-Calibrate Pass Pass Pass Pass
Salt Lake Compressor Station Unit 2 Mid-Low Flow & Moisture
As ft^2 Pbar Pq (static) Ps Avg. Ts F CO2 - FCO2 O2 N2+C Md Ms
56.25 25.78 0.00 25.78 3.00 15.70 81.30 29.11 29.11
Y Cp Vm cf Vlc AVG Tm F Vm std Vw std Bws S Bws
0.0000 #DIV/0!0.999
Load - Megawatts
Avg. √∆P's Vs Qsw scfh wet Qa acfm Qsd dscfh
Heat Input
Btu/hr.Low Mid High
95.36556 Enter >X
3D Pitot #1 - Times
Date
Point No.∆P √∆P ts F tm F (in) tm F (out)
Final
Vf
Initial
Vi
1
2
3
4
5
6 Sum
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
Failed Bias Dialog
Failed Drift Dialog
Failed Cal Error Dialog
Failed Bias Dialog
Unit 2 mid low $1_RM 2, 2F, 2G, 2H, 3A, 6C, 7E, 10, _ 19 - RA (B_W(Modified Feb. 27, 2018)
Division of Air Quality Stack Test Review of
Kern River Gas Transmission Company
SO2 NOX CO CO2 O2 Salt Lake Compressor Station Unit 2 Mid-Low
CS Calibration Span 50.25 50.14 21.59 22.02
Units ppm ppm ppm %%
CV - Cylinder Value:SO2 NOX CO CO2 O2
Low-Level 0.00 0.00 0.00 0.00
Mid-Level 25.23 25.32 9.91 10.21
High-Level 50.25 50.14 21.59 22.02
0 to 20% of Cal. Span 0.00%0.00%0.00%0.00%
40 to 60% of Cal. Span 50.2%50.5%45.9%46.4%
100% of Cal. Span 100.0%100.0%100.0%100.0%
Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration.
CMA 25.23 25.32 9.91 10.21
Calibration Error Test
Measured Concentration SO2 NOX CO CO2 O2
Low-Level -0.03 0.10 -0.03 0.00
Mid-Level 25.10 25.00 10.24 10.43
High-Level 50.22 49.98 21.57 22.00
Enter Up-scale Analyzer Response to be used during testing.
ACE Eq. 7E-1 25.10 25.00 10.24 10.43
Low-Level 0.06%0.20%0.12%0.00%
ppmv Difference 0.031 0.1 0.025 15
Status Passed Cal. Passed Cal. Passed Cal.Passed Cal.
Mid-Level 0.26%0.64%1.54%0.98%
ppmv Difference 0.132 0.32 0.333 0.215
Status Passed Cal. Passed Cal. Passed Cal.Passed Cal.
High-Level 0.07%0.31%0.10%0.09%
ppmv Difference 0.035 0.157 0.021 0.02
Status Passed Cal. Passed Cal. Passed Cal.Passed Cal.
Pre-Test Sampling System Bias
Initial Values SO2 NOX CO CO2 O2
CO - Low-Level 0.20 0.00 0.00 0.03 System Bias.
SBi - Zero Bias TRUE 0.46%0.20%0.12%0.11%± 5% of Span
Difference TRUE 0.231 0.1 0.025 0.025
Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal.
CM - Up-scale Gas 24.42 24.14 9.68 10.28
SBi - Up-Scale Bias TRUE 1.36%1.71%2.63%0.68%
Difference TRUE 0.681 0.858 0.567 0.15
Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal.
Raw Test Data Time Start Stop
Test Date:12/6/2023 SO2
SO2 NOX CO CO2 O2 NOX
16.2 0.69 3.0 15.8 CO
0.0% 32.2% 1.4% 13.8% 71.6%CO2/O2
Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100
Final Values SO2 NOX CO CO2 O2
CO - Low-Level 0.41 -0.10 0.05 0.38 System Bias.
SBi - Zero Bias TRUE 0.88% 0.40% 0.35% 1.70%± 5% of Span
Difference TRUE 0.4 0.2 0.1 0.4
Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal.
CM - Up-scale Gas 24.57 24.04 10.24 10.45
SBi - Up-Scale Bias TRUE 1.06%1.92%0.00%0.11%
Difference TRUE 0.5 1.0 0.0 0.0
Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal.
Calibration Drift % of Span - D=ABS(SBf - SBi)
Low-Level Drift TRUE 0.42%0.20%0.23%1.59%Response Spec.
Difference TRUE 0.2 0.1 0.1 0.4 3% of Span
Pass or Re-Calibrate Pass Pass Pass Pass
Up-scale Gas Drift TRUE 0.30% 0.21% 2.63% 0.57%
Difference TRUE 0.1 0.1 0.6 0.2
Pass or Re-Calibrate Pass Pass Pass Pass
Salt Lake Compressor Station Unit 2 Mid-Low Flow & Moisture
As ft^2 Pbar Pq (static) Ps Avg. Ts F CO2 - FCO2 O2 N2+C Md Ms
56.25 25.77 0.00 25.77 2.98 15.64 81.38 29.10 29.10
Y Cp Vm cf Vlc AVG Tm F Vm std Vw std Bws S Bws
0.0000 #DIV/0!0.999
Load - Megawatts
Avg. √∆P's Vs Qsw scfh wet Qa acfm Qsd dscfh
Heat Input
Btu/hr.Low Mid High
95.36556 Enter >X
3D Pitot #1 - Times
Date
Point No.∆P √∆P ts F tm F (in) tm F (out)
Final
Vf
Initial
Vi
1
2
3
4
5
6 Sum
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
Failed Bias Dialog
Failed Cal Error Dialog
Failed Drift Dialog
Failed Bias Dialog
Unit 2 low $1_RM 2, 2F, 2G, 2H, 3A, 6C, 7E, 10, _ 19 - RA (B_W(Modified Feb. 27, 2018)
Reference Methods 2, 3A, 6C, 7E, 10, & 19
Source Information
Company Name Kern River Gas Transmission Company
Company Contact:Denise Kohtala
Contact Phone No.801-937-6347
Stack Designation:Salt Lake Compressor Station Turbine Unit 2 Low
Test & Review Dates
Test Date:12/6/2023 &
Review Date: 2/5/2024
Observer:Not observed
Reviewer:Paul Bushman
Emission Limits Emission Rates
SO2 NOX CO SO2 NOX CO
lbs./MMBtu
lbs./hr. 9.5 10.4 4.578 0.244
ppm 25.0 50.00 14.300 1.253
ppm @ ISO
%O2 Correction as a whole #15.00 15.00
Test Information
Equivalent
Diameter (in.)As ft^2 Y Dl H @ Cp Pbar Pq (static)
Ps
Stack Pressure
90.00 56.250 0
10
Contractor Information
Contact:Jeffery Daniels
Contracting Company: TRC Environmental Corporation
Address: 400 Corporate Circle, Suite P, Golden CO 80401
Phone No.: 630-880-4754
Project No.:
8634
Division of Air Quality
Instrumental Reference Methods - Gaseous Measurements
Rectangular
Method 19 - F factors for Coal, Oil, and Gas
Fd Fw Fc
dscf/MMBtu wscf/MMBtu scf/MMBtu Diluent
F factor used
O2
CO2
Anthracite 2
Bituminous 2
Lignite
Natural
Propane
Butane
10100
COAL
OIL
GAS
9780
9860
9190
8710
8710
8710
10540
10640
11950
320
10610
10200
10390
1970
1800
1910
1420
1040
1190
1250
Wet CEM
Correct For O2
CO2 Interference w/CO
Yes
Yes
Yes
Unit 2 low $1_RM 2, 2F, 2G, 2H, 3A, 6C, 7E, 10, _ 19 - RA (B_W(Modified Feb. 27, 2018)
Calibration Error Test
Test Date December 6, 2023 O2
CS - Cal. Span 22.02
Units %
Cylinder No. Expiration
Date Cal. Gas CV- Certified
Concentration
CDir or CS -
Measured
Concentration
Difference
ACE Eq. 7E-1
Analyzer Cal.
Error
Status
Low-level 0.00 0.00 0.00 0.00%Passed Cal.
SG9166178BAL 07/18/31 Mid-level 10.21 10.43 0.22 0.98%Passed Cal.
CC58424 07/30/27 High-level 22.02 22.00 0.02 0.09%Passed Cal.
% of Span Sec. 8.2.1 Cal Gas Verification
0 to 20% of CS - Cal. Span Low-Level 0.00%
40 to 60% of Cal. Span Mid-level 46.37%
100% of Cal. Span High-level 100.00%
Test Date December 6, 2023 CO2
CS - Cal. Span 21.59
Units %
Cylinder
No.
Expiration
Date Cal. Gas CV- Certified
Concentration
CDir or CS -
Measured
Concentration
Difference
ACE Eq. 7E-1
Analyzer Cal.
Error
Status
Low-level 0.00 -0.03 0.03 0.116%Passed Cal.
SG9166178BAL 07/18/31 Mid-level 9.91 10.24 0.33 1.542%Passed Cal.
CC58424 07/30/27 High-level 21.59 21.57 0.02 0.097%Passed Cal.
% of Span Sec. 8.2.1 Cal Gas Verification
0 to 20% of Cal. Span Low-Level 0.00%
40 to 60% of Cal. Span Mid-level 45.90%
100% of Cal. Span High-level 100.00%
Test Date SO2
CS - Cal. Span
Units ppm
Cylinder
No.
Expiration
Date Cal. Gas CV- Certified
Concentration
CDir or CS -
Measured
Concentration
Difference
ACE Eq. 7E-1
Analyzer Cal.
Error
Status
Low-level
Mid-level
High-level
% of Span Sec. 8.2.1 Cal Gas Verification
0 to 20% of Cal. Span Low-Level
40 to 60% of Cal. Span Mid-level
100% of Cal. Span High-level
Test Date December 6, 2023 NOx
CS - Cal. Span 50.25
Units ppm
Cylinder
No.
Expiration
Date Cal. Gas CV- Certified
Concentration
CDir or CS -
Measured
Concentration
Difference
ACE Eq. 7E-1
Analyzer Cal.
Error
Status
Low-level 0.00 -0.03 0.03 0.062%Passed Cal.
CC365571 10/31/26 Mid-level 25.23 25.10 0.13 0.263%Passed Cal.
EB0119277 05/04/28 High-level 50.25 50.22 0.03 0.070%Passed Cal.
% of Span Sec. 8.2.1 Cal Gas Verification
0 to 20% of Cal. Span Low-Level 0.00%
40 to 60% of Cal. Span Mid-level 50.21%
100% of Cal. Span High-level 100.00%
Test Date December 6, 2023 CO
10.38 CS - Cal. Span 50.14
50 Units ppm
Cylinder
No.
Expiration
Date Cal. Gas CV- Certified
Concentration
CDir or CS -
Measured
Concentration
Difference
ACE Eq. 7E-1
Analyzer Cal.
Error
Status
Low-level 0.00 0.10 0.10 0.199%Passed Cal.
CC365571 10/31/26 Mid-level 25.32 25.00 0.32 0.638%Passed Cal.
EB0119277 05/04/28 High-level 50.14 49.98 0.16 0.313%Passed Cal.
% of Span Sec. 8.2.1 Cal Gas Verification
0 to 20% of Cal. Span Low-Level 0.00%
40 to 60% of Cal. Span Mid-level 50.50%
100% of Cal. Span High-level 100.00%
Valid Cal Gas
Valid Cal Gas
Valid Cal Gas
Valid Cal Gas
Valid Cal Gas
Valid Cal Gas
Valid Cal Gas
Valid Cal Gas
Unit 2 low $1_RM 2, 2F, 2G, 2H, 3A, 6C, 7E, 10, _ 19 - RA (B_W(Modified Feb. 27, 2018)
Division of Air Quality Stack Test Review of
Kern River Gas Transmission Company
SO2 NOX CO CO2 O2 Salt Lake Compressor Station Turbine Unit 2 Low
CS Calibration Span 50.25 50.14 21.59 22.02
Units ppm ppm ppm %%Unprotected
CV - Cylinder Value: SO2 NOX CO CO2 O2
Low-Level 0.00 0.00 0.00 0.00
Mid-Level 25.23 25.32 9.91 10.21
High-Level 50.25 50.14 21.59 22.02
0 to 20% of Cal. Span 0.00%0.00%0.00%0.00%
40 to 60% of Cal. Span 50.2%50.5%45.9%46.4%
100% of Cal. Span 100.0%100.0%100.0%100.0%
Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration.
CDir CMA 25.23 25.32 9.91 10.21
Calibration Error Test
Cs - Measured Concentration SO2 NOX CO CO2 O2
Low-Level -0.03 0.10 -0.03 0.00
Mid-Level 25.10 25.00 10.24 10.43
High-Level 50.22 49.98 21.57 22.00
Enter Up-scale Analyzer Response to be used during testing.
ACE Eq. 7E-1 25.10 25.00 10.24 10.43
Low-Level 0.06%0.20%0.12%0.00%
ppmdv Difference 0.031 0.1 0.025 0
Status Passed Cal. Passed Cal. Passed Cal.Passed Cal.
Mid-Level 0.26%0.64%1.54%0.98%
ppmdv Difference 0.132 0.32 0.333 0.215
Status Passed Cal. Passed Cal. Passed Cal.Passed Cal.
High-Level 0.07%0.31%0.10%0.09%
ppmdv Difference 0.035 0.157 0.021 0.02
Status Passed Cal. Passed Cal. Passed Cal.Passed Cal.
Pre-Test Sampling System Bias
Initial Values SO2 NOX CO CO2 O2
CO - Low-Level 0.41 -0.10 0.05 0.38 System Bias.
SBi - Zero Bias TRUE 0.88%0.40%0.35%1.70%± 5% of Span
Difference TRUE 0.441 0.2 0.075 0.375
Pass or Failed Invalid Run Passed Cal.Passed Cal.Passed Cal.Passed Cal.
CM - Up-scale Gas 24.57 24.04 9.28 10.45
SBi - Up-Scale Bias TRUE 1.06%1.92%4.47%0.11%
Difference TRUE 0.53 0.96 0.97 0.02
Pass or Failed Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal.
Raw Test Data Time Start Stop
Test Date:12/6/2023 SO2
SO2 NOX CO CO2 O2 NOX
12.5 0.74 2.9 15.8 CO
0.0% 24.9% 1.5% 13.3% 71.8% CO2/O2
Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100
Final Values SO2 NOX CO CO2 O2
CO - Low-Level 0.47 -0.40 0.50 0.10 System Bias.
SBi - Zero Bias TRUE 1.00% 1.00% 2.43% 0.45%± 5% of Span
Difference TRUE 0.5 0.5 0.5 0.1
Pass or Invalid Run Passed Cal.Passed Cal.Passed Cal.Passed Cal.
CM - Up-scale Gas 24.63 24.16 9.30 10.53
SBi - Up-Scale Bias TRUE 0.94%1.68%4.36%0.47%
Difference TRUE 0.5 0.8 0.9 0.1
Pass or Invalid Run Passed Cal.Passed Cal.Passed Cal.Passed Cal.
Calibration Drift % of Span - D=ABS(SBf - SBi)
Low-Level Drift TRUE 0.12%0.60%2.08%1.25%Drift
Difference TRUE 0.1 0.3 0.5 0.3 3% of Span
Pass or Re-Calibrate Pass Pass Pass Pass
Up-scale Gas Drift TRUE 0.12% 0.24% 0.11% 0.35%
Difference TRUE 0.1 0.1 0.0 0.1
Pass or Re-Calibrate Pass Pass Pass Pass
Salt Lake Compressor Station Turbine Unit 2 Low Flow & Moisture
As ft^2 Pbar Pq (static) Ps Avg. Ts F CO2 - FCO2 O2 N2+C Md Ms
56.250 25.78 0.00 25.78 2.88 15.51 81.62 29.08 29.08
Y Cp Vm cf Vlc AVG Tm F Vm std Vw std Bws S Bws #VALUE!
0.0000 0.00 0.999
Load - Megawatts
Avg. √∆P's Vs
(ft./sec.)Qsw scfh wet Qa acfm Qsd dscfh
Heat Input
Btu/hr.Low Mid High
87.15528 Enter >X
3D Pitot #1 - Times
Date
Point No.∆P √∆P ts F tm F (in) tm F (out)
Final
Vf
Initial
Vi
1
2
3
4
5
6 Sum
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
NOTE
These cells scans for the appropriate
Cir. gas after the Cm
If this scan is incorrect change the
Cdir to the correct gas value.
Failed Bias Dialog
Failed Drift Dialog
Failed Cal Error Dialog
CO Calibration Gas
Failed Bias Dialog
Unit 2 low $1_RM 2, 2F, 2G, 2H, 3A, 6C, 7E, 10, _ 19 - RA (B_W(Modified Feb. 27, 2018)
Division of Air Quality Stack Test Review of
Kern River Gas Transmission Company
SO2 NOX CO CO2 O2 Salt Lake Compressor Station Turbine Unit 2 Low
CS Calibration Span 50.25 50.14 21.59 22.02
Units ppm ppm ppm %%
CV - Cylinder Value:SO2 NOX CO CO2 O2
Low-Level 0.00 0.00 0.00 0.00
Mid-Level 25.23 25.32 9.91 10.21
High-Level 50.25 50.14 21.59 22.02
0 to 20% of Cal. Span 0.00%0.00%0.00%0.00%
40 to 60% of Cal. Span 50.2%50.5%45.9%46.4%
100% of Cal. Span 100.0%100.0%100.0%100.0%
Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration.
CMA 25.23 25.32 9.91 10.21
Calibration Error Test
Measured Concentration SO2 NOX CO CO2 O2
Low-Level -0.03 0.10 -0.03 0.00
Mid-Level 25.10 25.00 10.24 10.43
High-Level 50.22 49.98 21.57 22.00
Enter Up-scale Analyzer Response to be used during testing.
ACE Eq. 7E-1 25.10 25.00 10.24 10.43
Low-Level 0.06%0.20%0.12%0.00%
ppmdv Difference 0.031 0.1 0.025 0
Status Passed Cal. Passed Cal. Passed Cal.Passed Cal.
Mid-Level 0.26%0.64%1.54%0.98%
ppmdv Difference 0.132 0.32 0.333 0.215
Status Passed Cal. Passed Cal. Passed Cal.Passed Cal.
High-Level 0.07%0.31%0.10%0.09%
ppmdv Difference 0.035 0.157 0.021 0.02
Status Passed Cal. Passed Cal. Passed Cal.Passed Cal.
Pre-Test Sampling System Bias
Initial Values SO2 NOX CO CO2 O2
CO - Low-Level 0.41 -0.10 0.05 0.38 System Bias.
SBi - Zero Bias TRUE 0.88%0.40%0.35%1.70%± 5% of Span
Difference TRUE 0.441 0.2 0.075 0.375
Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal.
CM - Up-scale Gas 24.57 24.04 9.28 10.45
SBi - Up-Scale Bias TRUE 1.06%1.92%4.47%0.11%
Difference TRUE 0.531 0.964 0.965 0.025
Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal.
Raw Test Data Time Start Stop
Test Date:12/6/2023 SO2
SO2 NOX CO CO2 O2 NOX
12.5 0.89 2.9 16.0 CO
0.0% 24.9% 1.8% 13.3% 72.5%CO2/O2
Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100
Final Values SO2 NOX CO CO2 O2
CO - Low-Level 0.47 -0.40 0.10 0.50 System Bias.
SBi - Zero Bias TRUE 1.00% 1.00% 0.58% 2.27%± 5% of Span
Difference TRUE 0.5 0.5 0.1 0.5
Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal.
CM - Up-scale Gas 24.63 24.16 9.30 10.53
SBi - Up-Scale Bias TRUE 0.94%1.68%4.36%0.47%
Difference TRUE 0.5 0.8 0.9 0.1
Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal.
Calibration Drift % of Span - D=ABS(SBf - SBi)
Low-Level Drift TRUE 0.12%0.60%0.23%0.57%Response Spec.
Difference TRUE 0.1 0.3 0.1 0.1 3% of Span
Pass or Re-Calibrate Pass Pass Pass Pass
Up-scale Gas Drift TRUE 0.12% 0.24% 0.11% 0.35%
Difference TRUE 0.1 0.1 0.0 0.1
Pass or Re-Calibrate Pass Pass Pass Pass
Salt Lake Compressor Station Turbine Unit 2 Low Flow & Moisture
As ft^2 Pbar Pq (static) Ps Avg. Ts F CO2 - FCO2 O2 N2+C Md Ms
56.25 25.78 0.00 25.78 2.88 15.77 81.35 29.09 29.09
Y Cp Vm cf Vlc AVG Tm F Vm std Vw std Bws S Bws
0.0000 #DIV/0!0.999
Load - Megawatts
Avg. √∆P's Vs Qsw scfh wet Qa acfm Qsd dscfh
Heat Input
Btu/hr.Low Mid High
87.78684 Enter >X
3D Pitot #1 - Times
Date
Point No.∆P √∆P ts F tm F (in) tm F (out)
Final
Vf
Initial
Vi
1
2
3
4
5
6 Sum
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
Failed Bias Dialog
Failed Drift Dialog
Failed Cal Error Dialog
Failed Bias Dialog
Unit 2 low $1_RM 2, 2F, 2G, 2H, 3A, 6C, 7E, 10, _ 19 - RA (B_W(Modified Feb. 27, 2018)
Division of Air Quality Stack Test Review of
Kern River Gas Transmission Company
SO2 NOX CO CO2 O2 Salt Lake Compressor Station Turbine Unit 2 Low
CS Calibration Span 50.25 50.14 21.59 22.02
Units ppm ppm ppm %%
CV - Cylinder Value:SO2 NOX CO CO2 O2
Low-Level 0.00 0.00 0.00 0.00
Mid-Level 25.23 25.32 9.91 10.21
High-Level 50.25 50.14 21.59 22.02
0 to 20% of Cal. Span 0.00%0.00%0.00%0.00%
40 to 60% of Cal. Span 50.2%50.5%45.9%46.4%
100% of Cal. Span 100.0%100.0%100.0%100.0%
Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration.
CMA 25.23 25.32 9.91 10.21
Calibration Error Test
Measured Concentration SO2 NOX CO CO2 O2
Low-Level -0.03 0.10 -0.03 0.00
Mid-Level 25.10 25.00 10.24 10.43
High-Level 50.22 49.98 21.57 22.00
Enter Up-scale Analyzer Response to be used during testing.
ACE Eq. 7E-1 25.10 25.00 10.24 10.43
Low-Level 0.06%0.20%0.12%0.00%
ppmv Difference 0.031 0.1 0.025 15
Status Passed Cal. Passed Cal. Passed Cal.Passed Cal.
Mid-Level 0.26%0.64%1.54%0.98%
ppmv Difference 0.132 0.32 0.333 0.215
Status Passed Cal. Passed Cal. Passed Cal.Passed Cal.
High-Level 0.07%0.31%0.10%0.09%
ppmv Difference 0.035 0.157 0.021 0.02
Status Passed Cal. Passed Cal. Passed Cal.Passed Cal.
Pre-Test Sampling System Bias
Initial Values SO2 NOX CO CO2 O2
CO - Low-Level 0.41 -0.10 0.05 0.38 System Bias.
SBi - Zero Bias TRUE 0.88%0.40%0.35%1.70%± 5% of Span
Difference TRUE 0.441 0.2 0.075 0.375
Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal.
CM - Up-scale Gas 24.57 24.04 9.28 10.45
SBi - Up-Scale Bias TRUE 1.06%1.92%4.47%0.11%
Difference TRUE 0.531 0.964 0.965 0.025
Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal.
Raw Test Data Time Start Stop
Test Date:12/6/2023 SO2
SO2 NOX CO CO2 O2 NOX
12.5 0.80 2.9 16.0 CO
0.0% 24.8% 1.6% 13.4% 72.8%CO2/O2
Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100
Final Values SO2 NOX CO CO2 O2
CO - Low-Level 0.47 -0.40 0.10 0.50 System Bias.
SBi - Zero Bias TRUE 1.00% 1.00% 0.58% 2.27%± 5% of Span
Difference TRUE 0.5 0.5 0.1 0.5
Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal.
CM - Up-scale Gas 24.63 24.16 9.30 10.53
SBi - Up-Scale Bias TRUE 0.94%1.68%4.36%0.47%
Difference TRUE 0.5 0.8 0.9 0.1
Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal.
Calibration Drift % of Span - D=ABS(SBf - SBi)
Low-Level Drift TRUE 0.12%0.60%0.23%0.57%Response Spec.
Difference TRUE 0.1 0.3 0.1 0.1 3% of Span
Pass or Re-Calibrate Pass Pass Pass Pass
Up-scale Gas Drift TRUE 0.12% 0.24% 0.11% 0.35%
Difference TRUE 0.1 0.1 0.0 0.1
Pass or Re-Calibrate Pass Pass Pass Pass
Salt Lake Compressor Station Turbine Unit 2 Low Flow & Moisture
As ft^2 Pbar Pq (static) Ps Avg. Ts F CO2 - FCO2 O2 N2+C Md Ms
56.25 25.77 0.00 25.77 2.89 15.83 81.28 29.10 29.10
Y Cp Vm cf Vlc AVG Tm F Vm std Vw std Bws S Bws
0.0000 #DIV/0!0.999
Load - Megawatts
Avg. √∆P's Vs Qsw scfh wet Qa acfm Qsd dscfh
Heat Input
Btu/hr.Low Mid High
87.89210021 Enter >X
3D Pitot #1 - Times
Date
Point No.∆P √∆P ts F tm F (in) tm F (out)
Final
Vf
Initial
Vi
1
2
3
4
5
6 Sum
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
Failed Bias Dialog
Failed Cal Error Dialog
Failed Drift Dialog
Failed Bias Dialog