Loading...
HomeMy WebLinkAboutDAQ-2024-004335 195 North 1950 West • Salt Lake City, UT Mailing Address: P.O. Box 144820 • Salt Lake City, UT 84114-4820 Telephone (801) 536-4000 • Fax (801) 536-4099 • T.D.D. (801) 903-3978 www.deq.utah.gov Printed on 100% recycled paper State of Utah Department of Environmental Quality Kimberly D. Shelley Executive Director DIVISION OF AIR QUALITY Bryce C. Bird Director SPENCER J. COX Governor DEIDRE HENDERSON Lieutenant Governor DAQC-1346-23 Site 12188 (B1) Christian Boudreau Staker Parson Companies 89 West 13490 South, Suite 100 Draper, Utah 84020-7209 Dear Mr. Boudreau: Re: Staker Parson Companies – Temporary Relocation/Operation, Notice of Intent – Washington County Your Notice of Intent dated December 7, 2023, to relocate portable aggregate equipment to the temporary project for Western Rock Products' Fort Pierce Pit, located two miles east of the Bloomington exit, near St. George, Utah, was received by the Utah Division of Air Quality (DAQ) and has been reviewed. The following equipment has been approved for operation for this temporary project: Three (3) diesel powered track mounted impact crushers Screen The State of Utah has permitted portable equipment for Staker Parson Companies on the Approval Order DAQE-AN115180014-15 dated July 6, 2015. The above location is a permitted aggregate facility with established production limits. All equipment operating at this site must be in accordance with the current Approval Order (AO) for this site DAQE-AN2188004-05 dated January 21, 2005. The production of aggregate and hours of operation from all temporary projects when combined with the permanent equipment’s production and hours of operation cannot exceed the 12-month rolling limits as per Condition 15.A and 15.B of this AO. Approval is granted to relocate and operate this equipment at the new location for a period not to exceed 180 operational days. As per Utah Administrative Code (UAC) R307-401-17, the operation of equipment at this temporary site may be for up to 180 working days in any calendar year not to exceed 365 consecutive days, starting from the initial relocation date. The operational days per site cannot be extended beyond the stipulated 365 consecutive day period. " " * " / Ú á Û Ù Û Ü DAQC-1346-23 Page 2 The owner/operator shall maintain records of the actual operation hours, days, and production rate, of the above referenced equipment at this relocation site and have the ability to submit the information to the DAQ upon the request of representatives of the director. Please make certain that the plant operator is aware of all the location specific requirements for this site and the conditions of the aforementioned AO. Federal New Source Performance Standards Subpart OOO requires that initial Method 9 observations be performed for all applicable portable crushers, screens and attached conveyors. Subpart OOO also mandates that all crushers constructed, modified, or reconstructed on or after April 22, 2008, which are not enclosed, must install spray bars on the equipment and keep maintenance records to ensure proper spray bar operations. Utah Division of Water Quality Storm Water Permits and regulations may apply to this temporary project. Please refer to Utah DEQ Water Quality’s current Storm Water Construction requirements for additional information. This approval for relocation in no way releases the owner or operator from any liability for compliance with all other applicable federal, state, and local regulations including the UAC. If you have any questions regarding this relocation authorization or the temporary relocation process please contact Susan Weisenberg at (385) 306-6512. Sincerely, Jay P. Morris Assistant Director JPM:SW:rh Enclosure: Submitted Temporary Relocation Form cc: Southwest Utah Public Health Department 4 * - - $ . — @ C v A ? A B @ E w C D ˜ 12/14/23, 11:28 AM State of Utah Mail - Portable/Temporary Relocation Form https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1784655169314454642%7Cmsg-f:1784655169314454642&…1/2 Susan Weisenberg <sweisenberg@utah.gov> Portable/Temporary Relocation Form 1 message noreply@qemailserver.com <noreply@qemailserver.com>Thu, Dec 7, 2023 at 1:09 PM Reply-To: trigger@qemailserver.com To: sweisenberg@utah.gov Susan/Chad: Site # -- Staker Parson has requested a Temporary Relocation. Please see the information below. Any attachments can be access by clicking on the links. Recipient Data: Time Finished: 2023-12-07 13:09:43 MST IP: 67.182.223.139 ResponseID: R_2Yc6dPyd9H4UEuR Link to View Results: Click Here URL to View Results: https://utahgov.iad1.qualtrics.com/apps/single-response-reports/reports/ oJhKgitmNrb1PuX6dNpFSjIFo3EzkGj3UMqvzQ%2E5GP5BcvW9q7%2EfZs-vvYA6iWM73VrvRC2P- CUaYwnCrGMGmb2CbbDS9w0UtXJb-GFqo5PsYw0n1y8QvKx6XMfEcTMoDJzMAQ3PhVfls1pN0pRIjHXuvJrhnzoD7 YDJLo%2E3IXDJIkhdhzirw0mOrBiu-kBJMJpjOUm6rzIfck4IkwiazA7SHVVtp1kPR8sc%2EVomVo-yBV- 4riwZXzsnRMTBBq%2EFh9zvzIcpgHuKptwqJmWJpc4eHhe1whgEgnZmer34NMaWiZZp-qD-V%2ExIBbpMavI0Z9Ai9d% 2Em8q5NspN40E%2ErgQ Response Summary: Please fill out the information below: Contact Person: Christian Boudreau Company Name: Staker Parson Mailing Address: 89 W 13490 S City: Draper Zip: 84020 Phone Number: 3853186938 Email: christian.boudreau@stakerparson.com Is the site located within a PM2.5 non-attainment and maintenance plan areas on cleared land grea... No All temporary relocation projects are required to submit a Fugitive Dust Control Plan (FDCP). Lo... 7372985DEA Briefly give directions to the site and/or physical address: 1834 4150 S, St. George, UT 84790 Proposed Relocation Information: Closest City St. George County Washington UTM X Coordinates 12 0273861 E UTM Y Coordinates 4101772 N Approximate distance to the nearest house/business 1200ft UTM X Coordinates to nearest house/business 12 0273536 E UTM Y Coordinates to nearest house/business 4101884 N Does this site currently have a permit with DAQ? 12/14/23, 11:28 AM State of Utah Mail - Portable/Temporary Relocation Form https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1784655169314454642%7Cmsg-f:1784655169314454642&…2/2 Yes If yes, what is the Permit (DAQ-AN) # ? DAQE-AN2188004-05 If yes, what is the Permit Holder's Name? Western Rock Products Please provide the permit ID for the equipment? (DAQE-XXXXXXXXX-XX) DAQE-AN115180014-15 Please list all the Equipment on Site:Note: It is important to identify ALL diesel powered engine... 1 Equipment Type Impact Crushers (3) Serial or ID# II.A.125 2 Equipment Type Screen Serial or ID# II.A.178 Please attach a site diagram showing the equipment layout and general site dimensions for this re... https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_2R1BnKGdC9WmO1Y Have any other state or local regulatory agencies issued any other "Conditional Use Permits" for... No Operational Information: (Please note: Operating time over 16 hours in a 24 hour period will re... Total Hours of operation per 24 hr period 16 Starting time of operation (am/pm) 8am Ending time of operation (am/pm) 10pm Maximum hourly production rate for project 500 TPH Expected startup date 12/08/2023 Expected completion date 12/08/2024 What type of application is this for? New Application In accordance with the fee schedule approved by the Utah State Legislature, the Division of Air Q... https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_1jNwIdY8xijLTC8 Owner/Operator Representative: https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_scmtazFCBs2C9YB 12/14/23, 11:26 AM State of Utah Mail - Re: [EXT] [WARNING: ATTACHMENT(S) MAY CONTAIN MALWARE][WARNING: MESSAGE ENCRYPTED… https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-a:r5411316024830785948%7Cmsg-f:1785192407185361972…1/2 Susan Weisenberg <sweisenberg@utah.gov> Re: [EXT] [WARNING: ATTACHMENT(S) MAY CONTAIN MALWARE][WARNING: MESSAGE ENCRYPTED]regarding new TRP submission to Fort Pierce 1 message Boudreau, Christian (Staker & Parson) <christian.boudreau@stakerparson.com>Wed, Dec 13, 2023 at 11:29 AM To: Susan Weisenberg <sweisenberg@utah.gov> Susan, I apologize for leaving that off, there is a track mounted generator for the crushers. Also, this will be in addition to our submittal from October. Thanks, Christian Get Outlook for iOS From: Boudreau, Christian (Staker & Parson) Sent: Friday, December 8, 2023 10:53:48 AM To: Waite, Glenn (Western Rock) <glenn.waite@westernrock.com> Subject: FW: [EXT] [WARNING: ATTACHMENT(S) MAY CONTAIN MALWARE][WARNING: MESSAGE ENCRYPTED]regarding new TRP submission to Fort Pierce Hey Glenn, Could you help me with some of this info? Thanks, Christian From: Susan Weisenberg <sweisenberg@utah.gov> Sent: Friday, December 8, 2023 10:26 AM To: Boudreau, Christian (Staker & Parson) <christian.boudreau@stakerparson.com> Subject: [EXT] [WARNING: ATTACHMENT(S) MAY CONTAIN MALWARE][WARNING: MESSAGE ENCRYPTED]regarding new TRP submission to Fort Pierce 12/14/23, 11:26 AM State of Utah Mail - Re: [EXT] [WARNING: ATTACHMENT(S) MAY CONTAIN MALWARE][WARNING: MESSAGE ENCRYPTED… https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-a:r5411316024830785948%7Cmsg-f:1785192407185361972…2/2 CAUTION: This email originated from outside of the organization. Do not click links or open attachments unless you are expecting this email and know the contents are safe. If you believe this email may be phishing or malicious, please use the Report Phish button. Hello - the current DAQ management requires a reference to diesel engines for relocated equipment, even on self- powered track equipment, unless the track engine is explicitly stated on the condition item on the AO equipment list. Will the submitted three impact crushers and screen be powered off of existing Fort Pierce engines or are additional engines being added? Also, will this relocation be in addition to the equipment granted on the October 27, 2023, Letter? Thanks Susan Weisenberg, Environmental Scientist Office: 385-306-6512 ATTENTION: Ce courriel vient de l'exterieur de l'entreprise. Ne cliquez pas sur les liens, et n'ouvrez pas les pièces jointes, à moins que vous ne connaissiez l'expéditeur du courriel et savez que le contenu est sécuritaire. Si vous pensez qu’il s’agit d’un courriel d’hameçonnage ou malveillant, veuillez cliquer sur le bouton Signaler une tentative d’hameçonnage.