Loading...
HomeMy WebLinkAboutDAQ-2024-004480DEPARTMENT OF THE ARMY TOOELE ARMY DEPOT'HEADQUARTERS 1 TOOELE ARMY DEPOT, BUILDING ,| TOOELE, UT 84074-s003 JANUARY 24,2024 Subject: Semiannual Periodic Startup, Shutdown, Malfunction, Permit number 4500006004 Bryce Bird Department of Environmental Quality Division of Air Quality ATTN: Compliance P.O. Box 144820 Salt Lake City, Utah 84114-4820 UTAH DEPARruENT OF E}.IVIRONMENTAL OUAUW JAN 2 I 2024 DIVISION OF AIR QUALTTY Dear Mr. Bird: Tooele Army Depot is providing the enclosed Semiannual Periodic Startup, Shutdown, Malfunction for the reporting period of June 1, 2023 through December 31 , 2023 and 2023 Annual Compliance Certifi cation. Should you have any questions regarding this matter, please contact Lonnie Brown of my staff at (435) 833-2526. I certify under penalty of law that this document and all attachments were prepared under my direction or supervision according to a system designed to assure that quality personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations. Sincerely, ft^ eXc e. Dennis Colonel, U.S. Army Commanding 2 Encls 1. Semiannual SSM Report 2. Annual Compliance Certification cc: USEPA Region 8 Eo sgs fE [i Er ri ai:E ;itB E$!t t $Ef IE E85S E t rge E. g_gi EEi i gBE: o o .tr troo o o oo o o troo o o tr5 oo 6 o tr oo o o oo o o a.E troo o o cu oo o a E troo a, .E E E.|lraaa sEgnt, a, 3EsJ TE gE o (dt.Jooo o koaov o o(,) rl)E ookooo\ adLo ov oELo() t)& o!Loo c)u o Looq) M o ko()o/ o Loo 0)v co o bor E (l,r o Eo A ta a,o 0)o (U q Eoo c ot!EH a)H QEOocoEo(!kk e&oooc).qt o_d Cd +.1 ='E tro ! ELe -c!o9 datr9 Buts€'E> EIo-Eo9taiooE EP 6 tr tr(! () iJ (! o. €)o 'E o-tl c)beArooxo€o o6 c E Ec E c Gq, G - o.c] €q(Eo oPEEo FHBH k'('443EoEeflg 8EF+ E; BE eE a: 6.X.!Jr =6HCl(!.9 6 Eo::t o.! oL()4} E€ g 6 c.) c.) oCIE!oeO EC d,8 orEq.E .Ebtre LOooQtrru 8tB - du'!otrLloO (\. =&'d q) to oooc aE "3ollo'iEbtrakc)lDortrcIiro =EOU o ko(.)o (d Eo-'4.ts 6E ilE E8E> &.o,E€! EE 36!0od BE6'i =odE C)qE oo- 9E d.EbH sE&fl-o) E E€trd>-ru o-oa'! -8Egs.E 3 i5.E s E a,h 4 c.)N g J Nj j q q c q b0 La Bo .o o +J -j,Io\o I lJ) + I f.-o (f) g, o ;EoO6,1rDN '.5 Nd LF{-ao !l Ak.=otrpHA -ts9H €ED9 E6r;troroO.Gt Fi j'!iH' t'8E.d-oCE4l{gE --i O'Ed &E.! rflE Euot IA .'a l+'E; IlV.r fllr +,ts8 ?,l1',5 q);8 a+, !-t (JBE foo .:oo HH8 ,gEH EUE 9.Iot+vdtr o)EE fl F J =o t LLoz aa o F J fa J Fz tu2Z LJu z[! I Ilul^l\JlrlzIU 2F M 0-l! O T alFtl tooloooootot+ +, El. 6'fr ke Eod+, G,(,!tHdd+,t -8gB sE C.ii?E E{ BEraog BEf T E iEBAtrN =OfrEIt{hX Eo rEs ri$t iEii gsii EigE g p;f s:;t5E E b HgE E.g EI Bagi ;E! ; o)o) .tl g oo o o trt, troo o o co :,) o o tr doo o o o oo oao cE troo o o a,t, oo o o tr oo o oa Eco U oao € tro(.) oc ELE.t.e, sE6nr!) a,iErrS EB E8 oEkoo G) oBkoa{)d o ko() ruu tro (d troo!o oEL oo& troE(6 e 0) tn o o€koo C)& o! oIo& oEko()ov E:o g dtoopo o!koo 0)d tro 6 L a)o!o otLooox o (gt 0)o Eo, Do A E a,A o Eo r (,aoo H"5nEI b cE f; E E€ si EilEBg AEgEf;E f lefiEE I.EE.E TH i EEE EI OenE ,hb'E o.o-trts BTAotd o.o sE t!^'2A',at 6+Et Ei-e E€ E.!.r9E i5E I >:!9etr YG E{t-.OrYOdf H€.E.E EEo 14 aeE g? r.- H.co I EB E EBE sgsc3€ E g.E o\oApdE EO'E3 ov EEotr(JC) ([(),4.hoe o 5-:o oElI kfrl'E.9 r,] H-O! &q IoEp-d it5I- 6(/) E FH -€ ;EgB:Ege $;iE E; EE e EgEBEEEBE Ef,EEEI *gE o do^gbt.Poa-6ctrro EE sEf $ E$iE tr Ld ai€ 8.pN IEi!i5 E.Ee: s; EEEE N+ Lo :lF o 0)o 6.co a) C) Eailo=ac 9E F,E oouc)oic olida ",! onbB e€ $Aoto o! Odtr d! 6EoSboE;i o B Ef s E ts€.8eI HE 6EE E t .tE4i.cQEoeo 8Eg€93 tst€: 6 -c hl'ESIHE"\.t _c al- 0., 5 HE EEtb o'E.H A-g€ E ,6EI [esotri EE€- >6 60...d (!.Y AJ O.QooEl 8Eb v, y; E&ErDa 6e= bOaOa6Et€g E {, F. q Nq q N n ? q tri p si; o m q i q) ca m bp i E?r<'E"i S f ?E<.r9 E868 I Fl / )(r (\ Eo E€t! 6HF6. EHEH F8.Ed Ed EE-o +rE c.r.Hh 8r EH 3E EE HE t+,l')tr l/) ,< +.H*E BEtr€ o.E SE '6 tu Eg XEHEIxC)6H'.Q -, Bg O.- .Id Efflts Pb.Hog idHbha.H !B'5s cl€ooccdo E Hgoq)()(.) L{ =HbH. SH E RE V I E W E D In i t i a l s : Da t e : F e b 1 , 2 0 2 4 Co m p l i a n c e S t a t u s : N o n - c o m p l i a n t Fi l e # : 1 1 5 9 4 ( B 2 ) Co m m e n t : R e v i s e - C o n d i t i o n I I . B . 1 . g ne e d s t o i n d i c a t e J a n 2 4 , 2 0 2 3 , d e v i a t i o n di s c o v e r y . S h o u l d r e a d I n t e r m i t t e n t . Semiannual Excess Emissions, Monitoring, and Periodic Statup, Shutdown, and Malfunction RePort The statup, shutdown, and maltunction report shall be delivered or postmarked by the 30th day following the end of each calendar half. Facility Name: Reporting Period: Tooele Army Depot tn accordance with 40 CFR 63.10(dX5Xi), the following report is being submitted to document compliance with the reporting requirements associated with the Maximum Achievable Control Technology (MACT) regulations identified in Subpart EEE. lf actions taken by the owner or operator during a startup, shutdown, or malfunction of an affected source (including actions taken to correct a malfunction) are consistent with the procedures specified in the source's Startup, Shutdown, and Malfunction Plan (SSMP), the owner or operator shall state such information in a startup, shutdown, and malfunction report. During the reporting period the facility was consistent with the operating procedures specified in the Startup, Shutdown, and Malfunction Plan. Based on the information and Belief formed after reasonable inquiry, ! certify that the statement and information in this document are true, accurate, and complete. ?t T^ r-l ERIC B. DENNIS COL, LG Commanding Print or type the name and title of the Responsible official 1-Jul-23 End: 31-Dec-23 Signature of a Responsible Official for the Source UTAH DEPARTMENT OF .Jlrll ? I 2024 DIVISION OF AIR QUALITY ENVIRONMENTAL QUALITYREVIEWEDInitials: Date: Feb 1, 2024Compliance Status: OKFile #: 11594 (B2) Summary Report Excess Emission and Continuous Monitoring System Performance Company name: Tooele Army Depot (TEAD) Mailing Address l Tooele Army Depot City, State & Zip: Tooele, Utah 84074 Unit Description in accordance with 40 CFR 53.10(eX3(viXDl: APE 1235 Deactivation Furnace: J,{ft 2 g 2024 TEAD.N Excess Emission Monitoring, CMS Periodic, and SSM System Performance Report The incinerator consists of an oil fired rotary kiln designed to demilitarize Army propellant, explosives and pyrotechnics (PEP) reactive waste muntions. Changes in Continuous Monitoring System (CMS), Process, or Controls since last Reporting in accordance with 40 CFR 63.10(el(3(viXK): Hazardous Air Pollutants (HAPs) Monltoring in Accordance wlth 40 CFR 63.1O(eX3(viXBl: Pollutants Monitored MonitorinS Method Dioxins/Furans CMS Operating Parameter Limits Low Volatile Metals (arsenic, Beryllium and Chromium) CMS Operating Parameter Limits Semi-Volatile Metals (Cadmium and Lead)CMS Operating Parameter Limits Chlorine CMS Operating Parameter Limits Particulate Matter CMS Operating Parameter Limits CO and O2 CEMS .#,IffiNilHfrfl DIVISION OFAIR QUALITY 1of6 REVIEWEDInitials: Date: Feb 1, 2024Compliance Status: OKFile #: 11594 (B2) Emissions and Operating Parameter Limitations in Accordance with 40 CFR 63.10(el(3(viXD): APE 1236 Deactivation Furnace Ippllcable imissions itandards Process Descrlption cMs/cEMs lnstrument Tag lD Ar.Gla E.a. MACTlimltCut Off Activation Basisl HU, UKt, DIF Min Afterburner Temp Ttc702 HRA <7607"F SVM, LVM Max Afternburner Temp Ttc702 HRA >1811"F HL, UKE, DIF,PM, SVM, IVM, HCL/CL,Max Stack Velocity FT1401 HRA >44 fps HC, DRt, D?F Max Propellant, Explosives and pyrotechnics feed Rate2 Calculated L32lblhr PM Max Particulate Matter Generation Ratez Calculated 55lb/hr SVM Max Semi volatile Metals Feed Ratez Calculated 14 lb/hr LVM Low Volatile Metals Feed Rate'Calculated 19 lblhr SVM, LVM, HCL/CL,Max Total Chlorine and Chloride Feed Rate2 Calculated 2.2lb/hr olF Min Baghouse lnlet Temp3 Tt1004 HRA <801'F )lF Max Baghouse lnlet Temp3 Tt1004 HRA >7042"F HC, DRE Max Stack Gas Carbon Monoxide Concentration3 Ar1300 HRA 100 ppmva 1 HRA refers to hourly Rolling Average 2 There is no averaging period associated with these OPLs. ln Lieu of continuously calculating the feed of this parameter, the US Army determines the feed rate of each item that will ensure compliance with all of the constituent feed rate limits and maintain the item feed rate below this oredetermined rate. 3 Determine form manufacturer's recommendations, designed specifications, or HWC NESHAP requirements, not CPT Determinations. 4 Dry basis, corrected to seven percent oxygen. TEAD.N Excess Emission Monitoring, CMS Periodic, and SSM System Performance Report2of 6 Relevant Standards per 40 CFR 63.1219(a): Operating Hours for Each Source in accordance with 40 CFR 63.10(eX3Xvi)(H): CMS Excess Emissions and Parameter Exceedance Data Summary in accordance with 40 CFR 53.1o(eX3l(viXl): Pollutant Performance Standard )estruction and Removal Efficiency (DRE)>99.99% >articulate Matter 0.013 grldscf @ 7%02 {ydrocarbons (HC}10 ppmv (dry) {vdroeen Chloride 32 parts per million by volume, combined emissions, expressed as a chloride larbon Monoxide (CO) 100 ppmv corrected to 7% oxygen over a one hour rolling average and shall not exceed 500 ppmv, dry basis, for more that one minute at a time. iemi-volatile Metals (SVMXlead and cadmium :ombined 230 ggldscm @ 7%02 Low volatile metals (LVM)(arsenic and beryllium and chromium combined)92 pgldscm @ 7%O2 Dioxin and Furans 1.20 ng TEQ/dscm @ 7%02 Mercury 130pg/dscm @7/oO2 Source Source Hazardous Waste Operatlng Hours in Reporting Periodr l2-Month Rollint Total of lnclnerator Operatlng Hours Hazardous Waste 12- Month Rollin8 Hours of Operation APE 1236 Deac Furnace 1071.91 1440.30 3340 Source A. Hazardous Waste Operating Time (Hr) B. HoursTotal Excess Emission (EEl or Parameter Exceedance {PEI C. Percent of Hazardous Waste Operating Time for EE and PE (100r8/Al APE 1236 Deac Furnace to7L.9t 0.00 0.0O/o Source D. Hours PE or EE due to startup or shutdown E. Hours PE or EE due to Control Equipment Problems F. Hours PE or EE due to Process Problems APE 1236 Deac Furnace 0 2.25 0.750 Source G. Hours PE or EE due to Other Problems H. Hours PE or EE due to Unknown Problems APE 1235 Deac Furnace 0.00 0.75 TEA},N Excess Emission Monitoring, CMS Periodic, and SSM System Performance Report3of5 CMS Performance Summary in accordance with 40 CFR 63.10(eX3XviXJl: lReporting Period is semiannually Residence time of the APE 1236 furnace at 1 RPM is approximately 10 minutes Model Number in accordance with 40 CFR Source A. Harardous Waste Operatlng Time (Hr) 8. Hourc - CMS Downtlme C. Percent of Operatlng Time for CMS downtime t100+B/Al APE 1236 Deac Furnace to7L.91 0 0 Source D. Hours Monitoring Equipment Malfunctlon E. nours lIOn' Monltorlng Equipment li rlfr r nr.+ian F. Hours Unknourn Cause APE 1236 Deac Furnace 0 0 0 Monitoring Equipment Manufacturer(s) al !d lnitrument D$crlptlon Alarm Llmlt Sp.n vlakG/ Mode Serial l{umber/ Ihermocouple ]D CelArdlt Freguency Cert/Audl Scheduled Cert/tudltnstrument Ttl number t valld Pdr-1003 Bagiouse Pressure Drop <3.5" W.C.0 to 15" w.C.Foxboro IDPlG D22411FM1B1 Annual 2l-Aua-22 tn complianc Aug-23 PT-1103 Rotary Kln Feed End Draft Plessure > Atmospheric (-2)to 2" w.C. ;oxboro/GP2 0 329152L Annual 23-AvB-22 ln :omplian(Aug-23 TT-505 Rotary Kiln Feed End femperature >580'r 0 to 2,200 'F Newport TNFCT{m1 Annual 23-Aug-72 ln :omplian(Aug-23 fi-702 Aft erburner Temperature <!607F 0 to 2,200 'F Newportfyp eK tNFCr-(mu Annual 23-AW-22 ln complianr Aug-23 TT-1002 Bag House lnletTemperature <Lo42'l 0 to 2,200 'F Newportfyp eK TNFCT-oq)U Annual 23-Aug-22 tn complianc Aug-23 rT-604 Rotary Kiln Burner End Temperature no limit 0 to 2,200 'F Newport rNFCT-0001 Annual 23-Auz-22 ln complianr Aug-23 TT-1401 Stack Temperature no limit 0 to 2,200 'F Kurzl454FT 756004-1 3-23-OC 000G13-14-01- 28-2G01-12 Annual 23-Aug-22 ln complian< e Aug-23 FT-11101 Stack Flow Rat€>44fps 0 to 100 linear tils Kunl454FT 7s@o/,-t3-23{X 0000-13-14-01- 28-2041-12 Annual 23-Aug-22 ln complianc e Aug-23 TEAD-N Excess Emission Monitoring, CMS Periodic, and SSM System Performance Report4of6 Monitoring Report tn accordance with Operating Permit provision t.S.2.a. and Utah Administrative Reporting Period:Start:1-Jul-23 End:31-Dec-23 ( X ) There were no deviations from any permit requirements Below is a list of permit requirements for which there were deviations. The list ( ) includes the information required by Operating Permit provision l.S.2.a and UAC R307- 415-6a(3)(cXi). See Periodic Startup, Shutdown, and Malfunction Report accordance 40 CFR 63.10(dX5Xi) on next page. ln lieu of attaching the above list, deviation reports submitted in accordance with permit provisions 1.S.2.c. and UAC R307-415-6a(3)@(ii) are referenced Below ln accordance with Operating Permit provision l.K and UAC R307-415-5d, and based on information and belief formed after reasonable inquiry, I certifo that the statements and information in this document are true, accurate, and complete. ? \ Anv L'l () ERIC B. DENNIS COL, LG Commanding Date TEADN Excess Emission Monitorin8, CMS Periodic, and SSM System Performance Report5of5 REVIEWEDInitials: Date: Feb 1, 2024Compliance Status: OKFile #: 11594 (B2) Periodic Startup, Shutdown, and Malfunction Report accordance 40 CFR 63.10(dX5l(il: lf actions taken by an owner or operator during a startup or shutdown (and the startup or shutdown causes the source to exceed any applicable emission limitiation in the relevant emission standards), or malfunction of an affected source (including actions taken to conect a malfunction) are consistent with the procedures specified in the source's startup, shutdown, and malfunction plan (see S 63.6(eX3)), the owner or operator shall state such information in a startup, shutdown, and malfunction report. The Startup, Shutdown and Malfunction investi8ation and evaluation in accordance with 40 CFR 63.1205(eX3Xii), 't() CFR 63.10(c) and 40 CFR 53.10(d)(sXi) Event Number Alarm Date and Time !n Alarm Date and Time Out Duratlon (hoursl Type Results of lnvestlgation Corrective Measures Taken 1 7l2ol2o23 6:17 7l2O/2O23 6:32 0.25 SSMP Flame Failure Afterburner. 2 712512023 6:31 712512023 6:46 0.2s SSMP Power Loss Restore Power 3 712712023 6t4t 712712023 5:56 0.25 SSMP DischarSe Converyor Jam Cleaned Converyor 4 8/312023 6:sL 813/20237:OG 0.2s SSMP Flame Failure Cleaned Thermocouple 5 8/a/2O236:47 814120237:O2 0.25 SSMP Flame Failure Replaced Thermocouple 6 9/6120236:46 9/6120237:Ot o.2s SSMP Discharge Converyor Jam Cleaned Converyor 7 thzl20238:O9 9/12/20238:24 0.25 SSMP Power Loss Restore Power 8 tOl2Ol2O23 t4:36 tOl2Ol2O23 L4:st o.25 SSMP DischarSe ConveryorJam Cleaned Converyor 9 LOl24l2O23 t4:59 L012a12023 1s:L4 o.2s SSMP Flame Failure Replaced Thermocoupl Wire 10 Ltlt4l2023 17:39 LLlL4l2O23 17154 0.25 SSMP Power Bump Power was restored 11 tUt7l2O237:32 Ltlt7120237:47 0.2s SSMP Dischar8e Converyor Jam Cleaned Thermocouple t2 ttl22l20237tt6 LU22120237:3r 0.25 SSMP Flame Failure Cleaned Thermocouple 13 L1'12712023 t7|17 1L12712023 t7:32 0.2s SSMP Fuel Pump Cleand Fuel Pump L4 Lt/2812023 Ls:07 7L12812O23 L5:16 0.25 SSMP Fuel Pump Replace Fuel Pump 15 12/7L/20238:59 L2lttl20239:L4 0.25 SSMP Discharge ConveryorJam Cleaned Thermocouple UTAH DEPARTMENT OF ENVIRONMENTAL OUALITY JAil 21 2024 DIVISION OF AIR OUALITY TEA},N Excess Emission Monitoring, CMS Periodic, and SSM System Performance Report5 of 5