HomeMy WebLinkAboutDAQ-2024-0079721 DAQC-443-24 Site ID 10364 (B1) MEMORANDUM TO: FILE – GRANITE SCHOOL DISTRICT – Cottonwood High School THROUGH: Chad Gilgen, Minor Source Compliance Section Manager FROM: Irene Tucker, Environmental Scientist DATE: March 7, 2024 SUBJECT: FULL COMPLIANCE EVALUATION, Minor, Salt Lake County INSPECTION DATE: January 3, 2024 and April 4, 2024 SOURCE LOCATION: 5715 South 1300 East, Salt Lake City SOURCE CONTACTS: Tim Hutchins, Head Custodian: 801-230-7544, tjhutchins@graniteschool.org Adam Sanderson, Assistant Custodian: 801-809-8941 ansanderson@graniteschool.org OPERATING STATUS: Operating PROCESS DESCRIPTION: The Granite School District operates five Weil-McClain 5M Btu/hr natural gas fired boilers to provide steam, comfort heat, and hot water for the school and to heat the swimming pool. One of the five boilers serves as backup. There is a 347 hp Caterpillar diesel emergency generator which provides electricity during power outages. There is a paint booth equipped with fabric filters in the wood shop. All the exhaust air from the paint booth is routed through two dust collectors before being vented to the atmosphere. APPLICABLE REGULATIONS: AO DAQE-066-02, dated January 22, 2002 40 CFR Part 63 Subpart ZZZZ—National Emissions Standards for Hazardous Air Pollutants for Stationary Reciprocating Internal Combustion Engines 40 CFR Part 63 Subpart JJJJJJ—National Emission Standards for Hazardous Air Pollutants for Industrial, Commercial, and Institutional Boilers Area Sources / : 2 SOURCE EVALUATION: 1. This AO applies to the following company: Site Office Corporate Office Location Cottonwood High School Granite School District 5715 South 1300 East 340 East 3545 South Salt Lake City, Utah 84121 Salt Lake City, Utah 84115 Phone Number: (801) 263-6272 (801) 263-6100 Fax Number: (801) 263-6291 (801) 263-6291 The equipment listed in this AO shall be operated at the following location: PLANT LOCATION: 5715 South 1300 East, Salt Lake City, Salt Lake County, Utah Universal Transverse Mercator (UTM) Coordinate System: UTM Datum NAD27 4,449.7 km. Northing, 427.8 km. Easting, Zone 12 Status: In Compliance. The “corporate” office phone number is now (385) 646-5000 and the address is 2500 South State Street, Salt Lake City, Utah 84115. All other information is correct. 2. All definitions, terms, abbreviations, and references used in this AO conform to those used in the Utah Administrative Code (UAC) Rule 307 (R307), and Title 40 of the Code of Federal Regulations (40 CFR). Unless noted otherwise, references cited in these AO conditions refer to those rules. Status: This is not a compliance issue. 3. The limits set forth in this AO shall not be exceeded without prior approval in accordance with R307-401. Status: In Compliance. Based on the records reviewed, the Granite School District did not exceed the limits set forth in this AO. 4. Modifications to the equipment or processes approved by this AO that could affect the emissions covered by this AO must be approved in accordance with R307-401-1. Status: In Compliance. The Granite School District indicated that there were no modifications to the equipment or the processes approved by this AO. 5. All records referenced in this AO which are required to be kept by the owner/operator, shall be made available to the Executive Secretary or Executive Secretary’s representative upon request, and the records shall include the two-year period prior to the date of the request. Records shall be kept for the following minimum periods: All other records Two years Status: In Compliance. The Granite School District indicated that the records are kept for at least two years. 3 6. Granite School District shall operate the five dual fuel boilers, each rated at 5 x 106 Btu/hr and one 347 bhp diesel fired generator in accordance with the terms and conditions of this AO, which was written pursuant to Granite School District’s Notice of Intent (NOI) submitted to the Division of Air Quality (DAQ) on August 23, 2001, and additional information submitted to the DAQ on November 16, 2001. Status: In Compliance. The Granite School District indicated that all approved boilers and generators were operated according to this AO Condition. 7. The approved installations shall consist of the following equipment or equivalent*: A. Five (5) Boilers with the following characteristics each: Fuel Type: Natural Gas with Diesel as a back-up Type of Burner: 70 ppm NOx Heating Capacity: 5.0 x 106 Btu/hr B. One (1) Emergency Generator Fuel Type: Diesel Rating: 347 bhp * Equivalency shall be determined by the Executive Secretary. Status: In Compliance. There were no new and unapproved equipment identified onsite. The five 5.124 MMBtu Weil-McClain boilers only use natural gas. See the boiler information in the attachment. 8. Granite School District shall notify the Executive Secretary in writing when the installation of the equipment listed in Condition #7 has been completed and is operational, as an initial compliance inspection is required. To insure proper credit when notifying the Executive Secretary, send your correspondence to the Executive Secretary, attn: Compliance Section. Status: Out of Compliance. According to DAQC-541-17, the equipment was installed and operational before notifying the DAQ. This AO was issued to include the unapproved equipment in this AO. No further action required. 9. Visible emissions from the following emission points shall not exceed the following values: A. All boilers when with natural gas fired - 10% opacity B. All diesel engines and boilers when fired with diesel fuel - 20% opacity Opacity observations of emissions from stationary sources shall be conducted according to 40 CFR 60, Appendix A, Method 9. Status: In Compliance. There were no visible emissions observed from the Boilers or the Emergency Generator. The opacity observations were conducted according to 40 CFR 60, Appendix A, Method 9. See the attachment for additional information. 4 10. The following hours of operation and consumption limits shall not be exceeded: A. 109 x 106 standard cubic feet of natural gas per year (all boilers combined) per rolling 12-month period B. Operation (including periods for testing/maintenance) shall not exceed 500 hours per boiler per rolling 12-month period when operated on the diesel fuel #2 To determine compliance with a rolling 12-month total the owner/operator shall calculate a new 12-month total by the twentieth day of each month using data from the previous 12 months. Records of consumption and hours of operation shall be kept for all periods when the plant is in operation. Consumption shall be determined by monthly billings. Hours of operation shall be determined by supervisor monitoring and maintaining of an operations log. Status: In Compliance. The natural gas consumption from December 2022- November 2023, indicated the following: A. 50,469,949 standard cubic feet - See the attachment for additional information. B. The Granite School District indicated that diesel is not used as fuel in the boilers. See the natural gas specification on the plate of boiler in the attachment. 11. Emergency generators shall be used for electricity producing operation only during the periods when electric power from the public utilities is interrupted, or maintenance of the generators. Records documenting generator usage shall be kept in a log and they shall show the date the generator was used, the duration in hours of the of generator usage, and the reason for each generator usage. Status: In compliance. The Granite School District indicated that the emergency generator runs weekly for 30 minutes, and it is only used during power outages and testing purposes. Records of Weekly Generator Run times from January to December 2023, indicated 21.0 hours. 12. The owner/operator shall use only natural gas as a primary fuel and #2 diesel fuel oil as a backup fuel in the four boilers. The owner/operator shall use only #2 fuel oil in the emergency generator. Status: In Compliance. Only natural gas is used as a primary fuel in the five boilers. Only #2 fuel oil is used in the emergency generator. 13. The sulfur content of diesel fuel oil burned shall not exceed: 0.5 percent by weight The sulfur content shall be determined by ASTM Method D-4294-89 or approved equivalent. Certification of fuel oil shall be either by Granite School District’s own testing or test reports from the fuel oil fuel marketer. Status: In Compliance. According to the Certificate of Analysis from Sinclair, the sulfur content of the diesel indicated 6.3 parts per million ( ppm). See the attachment for additional information. 5 14. At all times, including periods of startup, shutdown, and malfunction, owners and operators shall, to the extent practicable, maintain and operate any equipment approved under this AO including associated air pollution control equipment in a manner consistent with good air pollution control practice for minimizing emissions. Determination of whether acceptable operating and maintenance procedures are being used will be based on information available to the Executive Secretary which may include, but is not limited to, monitoring results, opacity observations, review of operating and maintenance procedures, and inspection of the source. All maintenance performed on equipment authorized by this AO shall be recorded, and the records shall be maintained for a period of two years. Status: In Compliance. The Granite School District maintains all maintenance records performed on approved equipment for at least two years. 15. The owner/operator shall comply with R307-107 (Attachment A). General Requirements: Unavoidable Breakdowns. Status: In Compliance. The Granite School District indicated that there have been no unavoidable breakdowns resulting in an emissions event. APPLICABLE FEDERAL RULES 40 CFR Part 63 Subpart ZZZZ—National Emissions Standards for Hazardous Air Pollutants for Stationary Reciprocating Internal Combustion Engines Status: In Compliance. The Granite School District operates a 1991, 347 hp diesel-fueled Caterpillar emergency generator weekly for 30 minutes for testing and maintenance purposes. Records reviewed of Generator Run times from January-December 2023, indicated 21.0 hours. According to the Certificate of Analysis from Sinclair, the sulfur content of the diesel indicated 6.3 parts per million ( ppm). See the attachment for additional information. 40 CFR Part 60 Subpart Dc—Standards of Performance for Small Industrial-Commercial-Institutional Steam Generating Units Status. Not Applicable. The Granite School District operates five 5.124 MMBtu/hr natural gasfired boilers to provide steam, comfort heat, and hot water for the school and to heat the swimming pool. One of the five boilers serves as backup. Only boilers equal to or greater than 10 MMBtu are subject to this rule. The rolling 12-month natural consumption from December 2022, to November 2023, indicated 50,482 decatherms. See the attachment for additional information. 40 CFR Part 63 Subpart JJJJJJ—National Emission Standards for Hazardous Air Pollutants for Industrial, Commercial, and Institutional Boilers Area Sources Status: Not applicable: All the boilers are natural gas-fueled, and therefore, not applicable to this subpart. See the attachment for additional information. 6 AREA SOURCE RULES R307-305. Nonattainment and Maintenance Areas for PM10: Emission Standards Status: In Compliance. There were no visible emissions observed from the boilers and the emergency generator during this inspection. R307-343 Wood Furniture Manufacturing Operations Status: In Compliance. The Granite School District operates a paint booth equipped with fabric filters at the wood shop. All the exhaust air from the paint booth is routed through two dust collectors before being vented to the atmosphere. The Granite School District uses the Variseal HS Pre-Cat Clear Sealer and the Vanicure Low Gloss coatings which are hand-rubbed on the wood furniture or sprayed from a can. See the SDSs in the attachments. EMISSION INVENTORY: Not applicable. The Granite School District is not required to submit an Emissions Inventory Report at this time. The calculated PTE emissions for this AO in tons/year include the following: PM10: 0.83, NOx: 9.60, SO2: 3.70, CO: 1.38, and VOC: 1.29 PREVIOUS ENFORCEMENT ACTIONS: No enforcement action in the last five years. COMPLIANCE STATUS & RECOMMENDATIONS: In compliance. Based on the records reviewed, Granite School District is in compliance with the requirements of AO DAQE-066-02 dated January 22, 2002. The source maintained good housekeeping practices. RECOMMENDATION FOR NEXT INSPECTION: Inspect as usual. RECOMMENDATION FOR NSR PERMITTING REVIEW: Consider updating the boiler ratings to 5.124 MMBtu/hr. Consider removing 40 CFR Part 60 Subpart Dc applicability for the boilers based on the size. Consider removing 40 CFR Part 63 Subpart JJJJJJ applicability for the boilers based on the sole usage of natural gas. Consider including the paint booth in the wood furniture shop. Consider including the two dust collectors that are tied to the wood furniture shop. ATTACHMENTS: Visible Emission Observation Form, Natural Gas Consumption Log, Fuel Certification, SDSs, Photos