HomeMy WebLinkAboutDAQ-2024-005211 1 DAQC-171-24 Site ID 10313 (B5) MEMORANDUM TO: FILE - GRAYMONT WESTERN US INC. THROUGH: Harold Burge, Major Source Compliance Section Manager FROM: Rob Leishman, Environmental Scientist DATE: February 26, 2024 SUBJECT: Graymont Western US Inc. (Graymont), Major, NSPS, Title V, Millard County, FRS # UT00000049002700005 INSPECTION TYPE: State Electronic Data Report (SEDR) Review REVIEW DATE: February 26, 2024 SOURCE LOCATION: Cricket Mountain/Millard County SOURCE CONTACT: Eric Bennett, (435) 864-5770 APPLICABLE REGULATIONS: Title V Operating Permit Permit Number: 2700005004 Date of Permit: September 13, 2021 Date of Last Revision: September 13, 2021 SOURCE REVIEW EVALUATION: Fourth Quarter 2023 % Monitor Availability (MA) Performance Test Dates (N/A to Opacity) Summary of Excess Emissions During Point Source Operation Point Source Op. hrs. Channel MA CGA Lin RATA Point Source Channel Hrs. Limitation Kiln 1 1888 Opacity 98% Kiln 1 Opacity 0.00 15 % - 6 min Kiln 2 381 Opacity 98% Kiln 2 Opacity 0.00 15 % - 6 min Kiln 3 1074 Opacity 99% Kiln 3 Opacity 0.00 15 % - 6 min Kiln 4 416 Opacity 99% Kiln 4 Opacity 0.00 15 % - 6 min Kiln 5 1680 Opacity 99% Kiln 5 Opacity 0.00 15 % - 6 min ' 1 8 O 2 Excess Emission Report - Hourly Summary Point Source Channel Startup & Shutdown Control Equipment Problems Process Problems Other Known Causes Unknown Causes Emission Limit Kiln 1 Opacity 0 0 0 0 0 15 % - 6 min Kiln 2 Opacity 0 0 0 0 0 15 % - 6 min Kiln 3 Opacity 0 0 0 0 0 15 % - 6 min Kiln 4 Opacity 0 0 0 0 0 15 % - 6 min Kiln 5 Opacity 0 0 0 0 0 15 % - 6 min CMS Performance Summary - Hourly Summary Point Source Channel Monitor Malfunction Non-monitor Malfunction QA Calibrations Other Known Causes Unknown Causes Kiln 1 Opacity 24 0 18 0 0 Kiln 2 Opacity 0 0 3 5 0 Kiln 3 Opacity 0 0 11 0 0 Kiln 4 Opacity 0 0 4 0 0 Kiln 5 Opacity 8 0 14 0 0 Type Code 280 (COMS Attenuator Filters) Procedure 3 Point Source & Location Attenuator I.D. Attenuator Certification Date Certified Attenuator Opacity OPLR, SECR, or PLCF, Corrected Opacity Value Range Low, Mid, & High Certification 1-year or 5- year Kiln 1 - Stack ZQ04 6/19/23 8.70 1.00 8.7 Low 1 year Kiln 1 - Stack ZQ05 6/19/23 15.70 1.00 15.7 Mid 1 year Kiln 1 - Stack ZQ06 6/19/23 36.30 1.00 36.3 High 1 year Kiln 2 - Stack ZQ04 6/19/23 8.70 1.00 8.7 Low 1 year Kiln 2 - Stack ZQ05 6/19/23 15.70 1.00 15.7 Mid 1 year Kiln 2 - Stack ZQ06 6/19/23 36.30 1.00 36.3 High 1 year Kiln 3 - Stack ZQ04 6/19/23 8.70 1.00 8.7 Low 1 year Kiln 3 - Stack ZQ05 6/19/23 15.70 1.00 15.7 Mid 1 year Kiln 3 - Stack ZQ06 6/19/23 36.30 1.00 36.3 High 1 year Kiln 4 - Stack ZQ04 6/19/23 8.70 0.89 7.8 Low 1 year Kiln 4 - Stack ZQ05 6/19/23 15.70 0.89 14.1 Mid 1 year Kiln 4 - Stack ZQ06 6/19/23 36.30 0.89 33.1 High 1 year Kiln 5 - Stack ZQ04 6/19/23 8.70 1.00 8.7 Low 1 year Kiln 5 - Stack ZQ05 6/19/23 15.70 1.00 15.7 Mid 1 year Kiln 5 - Stack ZQ06 6/19/23 36.30 1.00 36.3 High 1 year 3 Type Code 281 (Procedure 3 - COMS Filter Audit Calibration Error) Point Source Location Audit Date Opacity Monitor Response (Average of 5) Mean Difference Calibration Error (≤ 3%) Low Mid High Kiln 1 Stack 11/1/23 9 0.290 0.419 Kiln 1 Stack 11/1/23 16 0.660 0.694 Kiln 1 Stack 11/1/23 37 1.000 1.040 Kiln 2 Stack 11/14/23 9 0.470 0.690 Kiln 2 Stack 11/14/23 16 0.610 0.690 Kiln 2 Stack 11/14/23 37 0.810 0.969 Kiln 3 Stack 11/30/23 9 0.390 0.459 Kiln 3 Stack 11/30/23 16 0.390 0.495 Kiln 3 Stack 11/30/23 37 0.510 0.567 Kiln 4 Stack 12/14/23 8 0.360 0.501 Kiln 4 Stack 12/14/23 15 0.500 0.626 Kiln 4 Stack 12/14/23 34 0.490 0.589 Kiln 5 Stack 12/19/23 9 0.670 0.705 Kiln 5 Stack 12/19/23 16 0.720 0.775 Kiln 5 Stack 12/19/23 37 0.840 0.855 Type Code 282 (Annual Zero Alignment Audit) Procedure 3 Point Source Location Audit Date Alternative Zero Alignment (Yes or No) COM Clear Condition Zero Response (CCZR) COM Simulated Zero Response (CSZR) Zero Alignment Error Difference (CCZR)- (CSZR) Adjustment to COM Simulated Zero Response (CSZR) (Yes or No) Kiln 1 Stack 11/1/23 Yes 0.20 0.05 0 No Kiln 2 Stack 11/14/23 Yes 0.10 -0.16 0 No Kiln 3 Stack 11/30/23 Yes -0.10 -0.14 0 No Kiln 4 Stack 12/14/23 Yes 0.60 -0.27 1 No Kiln 5 Stack 12/19/23 Yes 0.20 -0.01 0 No Pollutant Concentration Exceeded Span of CEM Monitor Outage During Point Source Operation Alternate Sampling CEM Modifications 0 Hours 86 Hours 0 Hours 0 Events 4 SOURCE INSPECTION SUMMARY EVALUATION: Graymont is maintaining its COMS as required in R307-170 and 40 CFR 60.13. CURRENT RECOMMENDATIONS: All deviations appear to be a result of breakdown or process related problems that do not warrant issuing a violation. Periods of excess emissions that were recorded by the CMS in service on each point source during this reporting period are summarized in the SEDR and described in Pivot Table 400 “Excess Emissions Review.” Graymont was in compliance during this reporting period. No further enforcement actions should be taken. Graymont’s NSPS monitoring system meets the performance standards of 40 CFR 60, Appendix B Performance Specification 1. HPV: No RECOMMENDATION FOR NEXT INSPECTION: Check DAS for daily zero and span drift. Check the QC program to ensure that monitor drift is being tracked and that the source can identify excessive drift. ATTACHMENT: Excel spreadsheet review ;;;;; VVVVVEg GRAYMONT I,TAH DEPARTMENT OF ENVIRONMENTAL QUAI.JW FEB - 1 2A24 January 23,2024 DIVISION OF AIR QUAUTY Bryce Bird, Director Division of Air Quality P.O. Box 144820 Salt Lake City, UT 84114-4820 RE: Fourth Quarter 2023 SEDR and Data Assessment Report for Kilns 1, 2, 3,4, & 5 Dear Mr. Bird: Graymont's Cricket Mountain Lime Plant located in Millard County, Utah, has submitted for Kilns 1,2,3,4, and 5 the Fourth Quarter 2023 SEDR and the Data Assessment Report as required by the Utah Air Quality Rules, to Rob Leishman by e- mail (rleishman@utah.gov). Enclosed you will find the Fourth Quarter Excess Emission and Monitoring System Performance Summary Report that is to be included with the SEDR report. Graymont acknowledges under penalties of law that all information contained in the SEDR is truthful and accurate and is a complete record of all monitoring related events that occurred during the reporting period. !f you have any questions or comments, please contact Eric Bennett at (435) 864-5770. Sincerely, U,r/oW Colby Roberts Plant Manager BB/eb Email:Slater Johnson, Colby Roberts, Cade Nielson - Graymont, Rob Leishman - UDEQ P.O. Box 669 Delta, UT 84624 USA Summary Report Quarterly Excess Emission and Monitoring System Performance Pollutant: Opacity Reporting Period Oates: 101112023 to 1213112023 company: Graymont Western US lnc. - Cricket Mountain Plant Emission Limitation: 15o/o Address: P.O. Box 669, Delta, UT 84624 Process Unit Description: Kiln #1, Kiln *2, Kiln #3, Kiln #4, and Kiln #5 - -Lli ,r tr P rr,,q P, i V r. r.rT OF.-- E t j,,.r i ROhll\,lE NTAL Ql_lALlTy 1 ?024 IVISION OF AIR OUALITY Kiln #1 Kiln f2 Kitn #B Kiln #4 Kitn *5 Monitor Manufacturer: Monitor Model #: Date of Latest CEM Certification or Audit: Total Source Operatinq Time in Reportinq Period: Teledyne Monitor Labs Lighthawk 560 1111t2023 1 13310 minutes Teledyne Monitor Labs Lighthawk 560 11t1412023 22890 minutes Teledyne lvlonrtor Labs Lighthawk 560 11t30t2023 il440 minutes Teledyne Monitor Labs Lighthawk 560 12t14t2023 24990 minutes Teledyne Monitor Labs Lighthawk 560 12t1912023 1 00800 minutes Ef,t SSrOA, DATA SUM|ilARY Kiln #1 Kiln lt2 Kiln rAi Kiln #4 Kiln #5 Duration of excess emissions in period due to a. Starlup/shutdown 0 minutes 0 minutes U mrnutes 0 minutes 0 minutes b. Control equipment problems 0 minutes U minutes U minutes U minutes minutes c. Process problems 0 minutes minutes 0 minutes 0 mtnutes n minutes d. Other known causes 0 minutes U minutes 0 minutes 0 manutes U minutes e. Unknown causes 0 manutes 0 minutes 0 mtnutes 0 minutes 0 minutes Total duration of excess emission 0 minutes 0 minutes 0 minutes 0 minutes 0 minuies [Total duratiion of excess emissions] x 100 / lTotal Source Operatinq Timel 0.00 o/o 0.00 o/o 000 0 0.00 0/o 000 0h CMS PERFORMANCE SUMMARY Kiln #1 Kiln #2 Kiln #3 Kiln #4 Kiln rrS 1. CMS downtime in reporting period due to a. Monitor equipment malfunctions 1452 minutes 0 minutes 0 minutes 0 minutes 450 minutes b. Non-monitor equipment malfunctions 0 minutes 0 mrnutes 0 minutes 0 minutes 0 minutes c. Quality assurance calibration 1056 minutes 180 minutes 649 minutes m in utes a52 minutes d. Other known causes 0 minutes 294 mtnutes 0 minutes 0 minutes 0 minutes e. Unknown causes 0 minutes 0 minutes 0 minutes 0 minutes 0 minutes Total cMS downtime 2508 mrnutes 474 mtnutes 649 minutes 216 minutes 1302 minutes lTotal CMS downtimel x 100 / lTotal Source ODeratino Time]2.21 o/o 2.07 o/o 1.0'1 0/o 0.86 0k 1.29 o/o Graymont EER 4Q2023 Point Source Information Late Expired Cal. Gas Valid Cal. Gas Days Yes No 1 Type Code 100 (Company Information)Type Code Company Manager Company Name AIRS # Phone Number Environmental Contact 1 100 Blake Bills 02700005 435-864-5770 Eric Bennett 1 100 0 0 0 0 1 Type Code 110 (Point Source Identification)Type Code Point Source Quarter 1 - 4 Year Point Source Operating Hrs. in Quarter 1 110 4 2023 1888.5 1 110 4 2023 381.5 1 110 4 2023 1074 1 110 4 2023 416.5 1 110 4 2023 1680 1 110 0 0 0 1 Type Code 200 (Monitor Identification)Type Code Point Source Channel Manufacturer Model No. Monitor SN Low Span High Span Installation Date Monitor Location 1 200 Opacity Teledyne Monitor Labs Lighthawk 560 5601662 0 100 9/30/2008 Kiln 1 stack 1 200 Opacity Teledyne Monitor Labs Lighthawk 560 5600904 0 100 10/13/2005 Kiln 2 stack 1 200 Opacity Teledyne Monitor Labs Lighthawk 560 5600905 0 100 10/13/2005 Kiln 3 stack 1 200 Opacity Teledyne Monitor Labs Lighthawk 560 5600906 0 100 11/8/2005 Kiln 4 stack 1 200 Opacity Teledyne Monitor Labs Lighthawk 560 5602280 0 100 11/29/2011 Kiln 5 stack 1 200 0 0 0 0 0 0 1/0/1900 0 1 Type Code310 (Excess Emissions) SUMMARY REPORT Type Code Channel Total Hours of Excess Emissions Excess Emissions - % of Total Operating Hours RC 701 Hours - start up/Shutdown RC 702 Hours- Control Equipment Problems RC 703 Hours - Process Problems RC 704, 706, 707 Hours -Other Known Causes RC 705 Hours - Unknown Causes Emission Limitation Emission Limitation Units Emission Limitation Averaging Period 1 TRUE 310 Opacity 0 0.00% 0 0 0 0 0 15 % 6 min 1 TRUE 310 Opacity 0 0.00% 0 0 0 0 0 15 % 6 min 1 TRUE 310 Opacity 0 0.00% 0 0 0 0 0 15 % 6 min 1 TRUE 310 Opacity 0 0.00% 0 0 0 0 0 15 % 6 min 1 TRUE 310 Opacity 0 0.00% 0 0 0 0 0 15 % 6 min 1 310 0 0 0 0 0 0 0 0 0 1 Type Code 300 (CMS Performance Summary) Type Code Channel Point Source Operating Hours Downtime - % of Total Operating Hours Total CMS Downtime RC 721 Hours - Monitor Malfunction RC 722 Hours - Non-monitor Malfunction RC 723 Hours - QA Calibrations RC 724 Hours - Other Known Causes RC 725 Hours - Unknown Causes 1 TRUE 300 Opacity 1888.5 2.21% 41.8 24.2 0 17.6 0 0 1 TRUE 300 Opacity 381.5 2.07% 7.9 0 0 3 4.9 0 1 TRUE 300 Opacity 1074 1.01% 10.82 0 0 10.82 0 0 1 TRUE 300 Opacity 416.5 0.86% 3.6 0 0 3.6 0 0 1 TRUE 300 Opacity 1680 1.29% 21.7 7.5 0 14.2 0 0 1 300 0 0 0 0 0 0 1 Type Code 250 (Performance Specification RATA Results) Type Code Channel Date of Most Current RATA Date of Preceding RATA Months Between RATA's Units of Measurement CEM Value Reference Method Value Relative accuracy Pass/ Fail 1 0 Days 250 0 01/00/00 01/00/00 0 0 0 0 0.00% 0 1 Type Code 260 (CGA Results)Type Code Channel Date Audit Point No. Cylinder ID Cylinder Expiration Date Type of Certification Units of Measurement CEM Value Cylinder Value Precision %Pass/ Fail Range - High or Low 1 260 0 01/00/00 0 0 01/00/00 0 0 0 0 0.00% 0 0 1 Type Code 270 (Linearity Test Results)Type Code Channel Date Audit Point No. Cylinder ID Cylinder Expiration Date Type of Certification Units of Measurement CEM Value Cylinder Value Precision %Pass/ Fail Range - High or Low 1 270 0 01/00/00 0 0 01/00/00 0 0 0 0 0.00% 0 0 1 Type Code 210 (Pollutant Concentration Exceeded Span of CEM) Type Code Channel Start Date Start Time End Date End Time Hours 1 0 0 0 1/0/00 0:00 1/0/00 0:00 1 1 None Reported 1 0 TC 220 Hours 85.82 TC 220 Hours 0.00 TC 230 Hours 0.00 Events 0.00 Hours 0.00 Events 0.00 0.00 1 85.82 TC 300 Hours 0.00 TRUE None Reported None Reported None Reported None Reported None Reported None Reported Point Source Point Source Point Source Point Source Point Source Point Source Yes Kiln 1 Kiln 2 Kiln 3 Kiln 4 Kiln 5 0 0 Kiln 3 Kiln 4 Kiln 5 Kiln 4 Kiln 5 0 Kiln 1 Kiln 2 Kiln 3 Type Code 550 (Changes in Operation in Control Equipment When CEM Data Not Available) Type Code 500 (Boiler Operating Days w/o 18 Hours of Data) Graymont 0 Type Code 450 (Data Excluded) Kiln 1 Kiln 2 Kiln 3 Kiln 4 Kiln 5 0 0 Kiln 1 Kiln 2 Type Code 210 (Pollutant Concentration Exceeded Span of CEM) Type Code 220 (Monitor Outage During Point Source Operation) Type Code 230 (Manual Sample - Alternate Sampling During Monitor Outage) Type Code 240 (CEM Modifications) Type Code 530 (Excess Emissions During Emergency Conditions) 0 0 0 Graymont EER 4Q2023 * Type Code 280 (COMS Attenuator Filters) Procedure 3 Point Source Location Attenuator I.D. Attenuator Certification Date Certified Attenuator Opacity OPLR, SECR, or PLCF, Corrected Opacity Value Range Low, Mid, & High Certification 1-year or 5-year Kiln 1 Stack ZQ04 6/19/23 9 1 8.7 Low 1 year Kiln 1 Stack ZQ05 6/19/23 16 1 15.7 Mid 1 year Kiln 1 Stack ZQ06 6/19/23 36 1 36.3 High 1 year Kiln 2 Stack ZQ04 6/19/23 8.7 1 8.7 Low 1 year Kiln 2 Stack ZQ05 6/19/23 15.7 1 15.7 Mid 1 year Kiln 2 Stack ZQ06 6/19/23 36.3 1 36.3 High 1 year Kiln 3 Stack ZQ04 6/19/23 8.7 1 8.7 Low 1 year Kiln 3 Stack ZQ05 6/19/23 15.7 1 15.7 Mid 1 year Kiln 3 Stack ZQ06 6/19/23 36.3 1 36.3 High 1 year Kiln 4 Stack ZQ04 6/19/23 8.7 0.89 7.8 Low 1 year Kiln 4 Stack ZQ05 6/19/23 15.7 0.89 14.1 Mid 1 year Kiln 4 Stack ZQ06 6/19/23 36.3 0.89 33.1 High 1 year Kiln 5 Stack ZQ04 6/19/23 8.7 1 8.7 Low 1 year Kiln 5 Stack ZQ05 6/19/23 15.7 1 15.7 Mid 1 year Kiln 5 Stack ZQ06 6/19/23 36.3 1 36.3 High 1 year * Opacity Monitor Response (Average of 5) Low Range Mid Range High Range Kiln 1 Stack 11/1/23 9 0.290 0.107 0.133 0.419 Kiln 1 Stack 11/1/23 16 0.660 0.027 0.034 0.694 Kiln 1 Stack 11/1/23 37 1.000 0.030 0.038 1.040 Kiln 2 Stack 11/14/23 9 0.470 0.175 0.218 0.690 Kiln 2 Stack 11/14/23 16 0.610 0.068 0.084 0.690 Kiln 2 Stack 11/14/23 37 0.810 0.129 0.161 0.969 Kiln 3 Stack 11/30/23 9 0.390 0.054 0.067 0.459 Kiln 3 Stack 11/30/23 16 0.390 0.086 0.107 0.495 Kiln 3 Stack 11/30/23 37 0.510 0.044 0.055 0.567 Kiln 4 Stack 12/14/23 8 0.360 0.111 0.138 0.501 Kiln 4 Stack 12/14/23 15 0.500 0.101 0.125 0.626 Kiln 4 Stack 12/14/23 34 0.490 0.076 0.095 0.589 Kiln 5 Stack 12/19/23 9 0.670 0.027 0.033 0.705 Kiln 5 Stack 12/19/23 16 0.720 0.043 0.053 0.775 Kiln 5 Stack 12/19/23 37 0.840 0.009 0.011 0.855 * Point Source Location Audit Date Alternitive Zero Alignment (Yes or No) COM Clear Condition Zero Response (CCZR) COM Simulated Zero Response (CSZR) Zero Alignment Error Difference (CCZR)-(CSZR) Adjustment to COM Simulated Zero Response (CSZR) (Yes or No) Kiln 1 Stack 11/1/23 Yes 0.200 0.050 0.150 No Kiln 2 Stack 11/14/23 Yes 0.100 -0.160 0.260 No Kiln 3 Stack 11/30/23 Yes -0.100 -0.140 0.040 No Kiln 4 Stack 12/14/23 Yes 0.600 -0.270 0.870 No Kiln 5 Stack 12/19/23 Yes 0.200 -0.010 0.210 No Type Code 282 (Procedure 3 - Annual Zero Alignment Audit) Point Source Location Audit Date Mean Difference Standard Deviation Confidence Coefficient Calibration Error (≤ 3%) Type Code 281 (Procedure 3 - COMS Filter Audit Calibration Error) Graymont EER 4Q2023 Monitoring Information TC 210, 230, & 240 Type Code 210 (Pollutant Concentration Exceeded Span of CEM) - 500 (All) * Sum of Hours Column Labels Row Labels (blank) Grand Total (blank)0 0 Grand Total 0 0 * Type Code 230 (Manual Sample - Alternate Sampling During Monitor Outage) - 500 (All) * Sum of Hours Column Labels Row Labels (blank) Grand Total (blank)0 0 Grand Total 0 0 * Type Code 240 (CEM Modifications) - 100 (All) * Count of Channel Column Labels Row Labels (blank) Grand Total (blank) (blank) Grand Total Graymont EER 4Q2023 Type Code 220 (Monitor Outage During Point Source Operation) - 600 (All) * Sum of Hours Column Labels Row Labels 723 721 724 Grand Total Kiln 1 Opacity Automatic daily zero and span calibration check.15.40 15.40 Power supply, controller, light source or air purge equipment malfunction. Zero voltage out of range fault. Cleaned monitor, performed sets, returned to normal operation. Cal mechanism motor change caused the zero and upscale to not be aligned properly, causing results of cal to be over 4%. Aligned the zero and upscale, and performed sets to restore monitor back to proper operating status. 24.20 24.20 Audit and/or cleaning of monitor. Returned to normal operation as soon as audit was over.2.20 2.20 Kiln 2 Opacity Automatic daily zero and span calibration check.3.00 3.00 Excessive dust accumulation on lens and/or in stack ports resulting from improper air purge. Lens and stack ports cleaned and air purge system maintenance performed. 4.90 4.90 Kiln 3 Opacity Automatic daily zero and span calibration check.8.80 8.80 Audit and/or cleaning of monitor. Returned to normal operation as soon as audit was over.2.02 2.02 Kiln 4 Opacity Automatic daily zero and span calibration check.3.60 3.60 Kiln 5 Opacity Automatic daily zero and span calibration check.14.20 14.20 Power supply, controller, light source or air purge equipment malfunction. Zero voltage out of range fault. Cleaned monitor, performed sets, returned to normal operation. Cal mechanism motor change caused the zero and upscale to not be aligned properly, causing results of cal to be over 4%. Aligned the zero and upscale, and performed sets to restore monitor back to proper operating status. 7.50 7.50 Grand Total 49.22 31.70 4.90 85.82 Graymont EER 4Q2023 Opy * Opy Count of Magnitude of Emissions Column Labels Opy Row Labels Grand Total Opy Grand Total Graymont EER 4Q2023 Type Code 500 Before February 28, 2005 (Boiler Operating Days w/o 18 Hours of Data) After February 28, 2005 (90% Operating Hours For each 30 BOD) - 500 (All) * Count of Channel Column Labels Row Labels Grand Total Grand Total * Type Code 510 (F-factor, Equations & Conversion Factors) - 500 (All) Count of F-factor Column Labels Row Labels Grand Total Grand Total * Type Code 520 (Minimum Data Not Obtained <22/30 BODs) - 500 (All) Count of Channel Column Labels Row Labels Grand Total Grand Total * Type Code 530 (Excess Emissions During Emergency Conditions) - 500 (All) Count of Date Column Labels Row Labels Grand Total Grand Total * Type Code 540 (Fuel Pre-treatment Credit SO2) - 500 (All) Count of Date Column Labels Row Labels Grand Total Grand Total * TypeCode 550 (Changes in Operation in Control Equipment When CEM Data Not Available) - 500 (All) Column Labels Row Labels Grand Total Grand Total