HomeMy WebLinkAboutDAQ-2024-0051591 DAQC-201-24 Site ID 10354 (B4) MEMORANDUM TO: STACK TEST FILE – UNIVERSITY OF UTAH THROUGH: Harold Burge, Major Source Compliance Section Manager FROM: Paul Morris, Environmental Scientist DATE: February 29, 2024 SUBJECT: Location: High Temp Water Plant, Bldg. 303, University of Utah, Salt Lake City, Salt Lake County, UT Contact: Bryan Cracroft (801) 585-1617 Tester: Alliance Technical Group Sources: Cogen Turbine, Boiler 6, Boiler 7, and Boiler 9 FRS Site ID#: UT0000004903500063 Action Code: TR Permit# Title V operating permit 3500063004 dated August 25, 2023 Subject: Review of Stack Test Report received February 23, 2024 On February 23, 2024, by email, the DAQ received a test report for the University of Utah Solar Taurus 70 CO Gen, Boiler 6, Boiler 7, and Boiler 9 at the High Temperature Water Plant, Building 303 located at the University of Utah, in Salt Lake City, UT. Testing was performed January 8-10, 2024, to demonstrate compliance with the emission limits found in Title V operating permit Conditions II.B.3.a and II.B.4.a. The DAQ-calculated test results are: Source Test Date RM/Pollutant DAQ Result Test Result Limit Turbine 1/9/2024 7E/NOX 1.0 lbs/hr 1.1 lbs/hr 2.65 lbs/hr 4 ppmdv** 4 ppmdv** 9 ppmdv** 10/CO 0.16 lbs/hr 0.17 lbs/hr 4.48 lbs/hr 1 ppmdv** 1 ppmdv** 25 ppmdv** Combined 1/8/2024 7E/NOX 2.6 lbs/hr 2.6 lbs/hr 8.97 lbs/hr 8 ppmdv** 8 ppmdv** 15 ppmdv** 10/CO 1.8 lbs/hr 1.8 lbs/hr 10.84 lbs/hr 9 ppmdv** 9 ppmdv** 30 ppmdv** Boiler 6 1/10/2024 7E/NOX 0.19 lbs/hr 0.19 lbs/hr 0.54 lbs/hr 8 ppmdv* 8 ppmdv* 9 ppmdv* Boiler 7 1/10/2024 7E/NOX 0.20 lbs/hr 0.19 lbs/hr 0.54 lbs/hr 8 ppmdv* 8 ppmdv* 9 ppmdv* Boiler 9 1/9/2024 7E/NOX 0.28 lbs/hr 0.27 lbs/hr 0.79 lbs/hr 8 ppmdv* 8 ppmdv* 9 ppmdv* * ppmdv @ 3% O2 ** ppmdv @ 15% O2 6 , 3 2 DEVIATIONS: None. CONCLUSION: The overall stack test report appears to be acceptable. RECOMMENDATION: The emissions appear to have been in compliance with the applicable limits at the time of testing. ATTACHMENTS: DAQ generated Excel spreadsheets Stack test report received February 23, 2024 Source Test Report University of Utah 200 S. University Avenue Salt Lake City, UT 84112 Sources Tested: Building 303 – One (1) Solar Taurus 70 CoGen, One (1) Rentech Waste Heat Recovery Unit, One (1) Gen 9 Boiler & Two (2) NSPS Boilers Test Dates: January 8-10, 2024 Project No. AST-2024-0023 Prepared By Alliance Technical Group, LLC 3683 W 2270 S, Suite E West Valley City, UT 84120 Source Test Report Test Program Summary AST-2024-0023 University of Utah – Salt Lake City, UT Page i Regulatory Information Permit Nos. Regulatory Citation Utah Department of Environmental Quality (UDEQ) Title V Permit No. 3500063004 DAQE-AN103540028-20 40 CFR 60, Subpart Dc 40 CFR 60, Subpart KKKK Source Information Source Name Source ID Target Parameters Solar Taurus 70 CoGen Bldg. 303 - Unit 1 NOx & CO Rentech Waste Heat Recovery Bldg. 303 - Unit 1 NOx & CO Gen 9 Boiler LCHTWP Boiler 9 NOx Two (2) NSPS Boilers Units 6 & 7 NOx Contact Information Test Location Test Company University of Utah 200 S. University Avenue Salt Lake City, UT 84112 Facility Contact Bryan Cracroft bryan.cracroft@fm.utah.edu (801) 585-1617 David Quinlivan david.quinlivan@fm.utah.edu (801) 550-3989 Alliance Technical Group, LLC 3683 W 2270 S, Suite E West Valley City, UT 84120 Project Manager / Field Team Leader Charles Horton charles.horton@alliancetg.com (352) 663-7568 QA/QC Manager Kathleen Shonk katie.shonk@alliancetg.com (812) 452-4785 Report Coordinator Delaine Spangler delaine.spangler@gmail.com 2 of 97 CERTIFICATION In accordance with operating permit provision I.K. and UAC R307-415-5d, and based on information and belief formed after reasonable inquiry, I certify that the statements and information in this document are true, accurate and complete. _______________________________________________________________ Signature of Responsible Official for the Source Ms. Robin Burr, Chief Facilities Officer Office of the Chief Financial Officer 02/23/2024 Source Test Report Certification Statement AST-2024-0023 University of Utah – Salt Lake City, UT Page ii Alliance Technical Group, LLC (Alliance) has completed the source testing as described in this report. Results apply only to the source(s) tested and operating condition(s) for the specific test date(s) and time(s) identified within this report. All results are intended to be considered in their entirety, and Alliance is not responsible for use of less than the complete test report without written consent. This report shall not be reproduced in full or in part without written approval from the customer. To the best of my knowledge and abilities, all information, facts and test data are correct. Data presented in this report has been checked for completeness and is accurate, error-free and legible. Onsite testing was conducted in accordance with approved internal Standard Operating Procedures. Any deviations or problems are detailed in the relevant sections in the test report. This report is only considered valid once an authorized representative of Alliance has signed in the space provided below; any other version is considered draft. This document was prepared in portable document format (.pdf) and contains pages as identified in the bottom footer of this document. Charles Horton, QSTI Alliance Technical Group, LLC Date 2/5/2024 3 of 97 Source Test Report Table of Contents AST-2024-0023 University of Utah – Salt Lake City, UT Page iii TABLE OF CONTENTS 1.0 Introduction .................................................................................................................................................. 1-1 1.1 Process/Control System Descriptions ...................................................................................................... 1-1 1.2 Project Team ............................................................................................................................................ 1-1 1.3 Site Specific Test Plan & Notification ..................................................................................................... 1-1 2.0 Summary of Results ..................................................................................................................................... 2-1 3.0 Testing Methodology .................................................................................................................................... 3-1 3.1 U.S. EPA Reference Test Method 3A – Oxygen/Carbon Dioxide ........................................................... 3-1 3.2 U.S. EPA Reference Test Method 7E – Nitrogen Oxides ........................................................................ 3-1 3.3 U.S. EPA Reference Test Method 10 – Carbon Monoxide ...................................................................... 3-1 3.4 U.S. EPA Reference Test Method 19 – Volumetric Flow Rate / Mass Emission Factors ....................... 3-1 3.5 U.S. EPA Reference Test Method 205 – Gas Dilution System Certification ........................................... 3-2 3.6 Quality Assurance/Quality Control – U.S. EPA Reference Test Methods 3A, 7E, and 10 ...................... 3-2 LIST OF TABLES Table 1-1: Project Team ........................................................................................................................................... 1-1 Table 2-1: Summary of Results – Unit 1 – Solar Taurus 70 CoGen (Turbine Only) ............................................... 2-1 Table 2-2: Summary of Results – Unit 1 – Solar Taurus 70 CoGen (Turbine and WHRU Duct Burner) ................ 2-2 Table 2-3: Summary of Results – Unit 6 .................................................................................................................. 2-2 Table 2-4: Summary of Results – Unit 7 .................................................................................................................. 2-3 Table 2-5: Summary of Results – Gen 9 Boiler ........................................................................................................ 2-3 Table 3-1: Source Testing Methodology .................................................................................................................. 3-1 APPENDICES Appendix A Sample Calculations Appendix B Field Data Appendix C Quality Assurance/Quality Control Data Appendix D Process Operating/Control System Data 4 of 97 Introduction 5 of 97 Source Test Report Introduction AST-2024-0023 University of Utah – Salt Lake City, UT Page 1-1 1.0 Introduction Alliance Technical Group, LLC (Alliance) was retained by University of Utah to conduct compliance testing at the Salt Lake City, Utah facility. Portions of the facility are subject to 40 CFR 60, Subparts Dc and KKKK. The facility operates under Utah Department of Environmental Quality (UDEQ) Title V Permit No. 3500063004. Testing was conducted to determine the emission rates of nitrogen oxides (NOx) and carbon monoxide (CO) at the exhausts of one (1) Solar Taurus 70 CoGen and one (1) Rentech Waste Heat Recovery Unit. Testing also included determining the emission rate of NOx at the exhaust of the two (2) NSPS Boilers (Unit 6 and 7) and Gen 9 Boiler. 1.1 Process/Control System Descriptions The High Temperature Water (HTW) Plant 303 produces electricity and heating water. The plant provides electricity, heating water, and steam to multiple building on Campus. One (1) natural gas fired Solar Taurus 70 T7800S (Solar's SoLoNox TM) turbine with one WHRU with duct burner rated at 85 MMBtu/hr are operated at the HTW Plant 303. Natural gas turbine is site rated at 7.23 MW with heat input of 72.78 MMBtu/hr. Gas turbine and duct burner are Subject to NSPS, 40 CFR, Part 60, Subpart KKKK. The Superior boiler is a 72 MMBtu/hr boiler designed to burn natural gas only. It is located at the Central HTW Plant, Building 303 on the Salt Lake City Campus 1.2 Project Team Personnel involved in this project are identified in the following table. Table 1-1: Project Team University of Utah Personnel Bryan Cracroft Alliance Personnel Ryan Lyons Supilani Mailei Andrew Crosby 1.3 Site Specific Test Plan & Notification Testing was conducted in accordance with the Site Specific Test Plan (SSTP) submitted to UDAQ by University of Utah. 6 of 97 Summary of Results 7 of 97 Source Test Report Summary of Results AST-2024-0023 University of Utah – Salt Lake City, UT Page 2-1 2.0 Summary of Results Alliance conducted compliance testing at the Salt Lake City, Utah facility on January 8 – 10, 2024. Testing consisted of determining the emission rates of NOx and CO at the exhausts of one (1) Solar Taurus 70 CoGen and one (1) Rentech Waste Heat Recovery Unit. Testing also included determining the emission rate of NOx at the exhaust of the two (2) NSPS Boilers (Unit 6 and 7) and Gen 9 Boiler. Tables 2-1 through 2-5 provide a summary of the emission testing results with comparisons to the applicable UDAQ permit limits. Any difference between the summary results listed in the following tables and the detailed results contained in appendices is due to rounding for presentation. Table 2-1: Summary of Results – Unit 1 – Solar Taurus 70 CoGen (Turbine Only) Run Number Run 1 Run 2 Run 3 Average Date 1/9/24 1/9/24 1/9/24 Nitrogen Oxides Data Concentration, ppmvd @ 15% O2 3.43 3.85 4.32 3.87 Permit Limit, ppmvd @ 15% O2 -- -- -- 9 Percent of Limit, % -- -- -- 43 Emission Rate, lb/hr 0.91 1.2 1.2 1.1 Permit Limit, lb/hr -- -- -- 2.65 Percent of Limit, % -- -- -- 41 Carbon Monoxide Data Concentration, ppmvd @ 15% O2 1.05 0.99 1.02 1.02 Permit Limit, ppmvd @ 15% O2 -- -- -- 25 Percent of Limit, % -- -- -- 4 Emission Rate, lb/hr 0.17 0.18 0.17 0.17 Permit Limit, lb/hr -- -- -- 4.48 Percent of Limit, % -- -- -- 4 8 of 97 Source Test Report Summary of Results AST-2024-0023 University of Utah – Salt Lake City, UT Page 2-2 Table 2-2: Summary of Results – Unit 1 – Solar Taurus 70 CoGen (Turbine and WHRU Duct Burner) Run Number Run 1 Run 2 Run 3 Average Date 1/8/24 1/8/24 1/8/24 Nitrogen Oxides Data Concentration, ppmvd @ 15% O2 7.51 7.70 7.73 7.65 Permit Limit, ppmvd @ 15% O2 -- -- -- 15 Percent of Limit, % -- -- -- 51 Emission Rate, lb/hr 2.6 2.6 2.6 2.6 Permit Limit, lb/hr -- -- -- 8.97 Percent of Limit, % -- -- -- 29 Carbon Monoxide Data Concentration, ppmvd @ 15% O2 8.71 8.65 8.82 8.73 Permit Limit, ppmvd @ 15% O2 -- -- -- 30 Percent of Limit, % -- -- -- 29 Emission Rate, lb/hr 1.8 1.8 1.8 1.8 Permit Limit, lb/hr -- -- -- 10.84 Percent of Limit, % -- -- -- 17 Table 2-3: Summary of Results – Unit 6 Run Number Run 1 Run 2 Run 3 Average Date 1/10/24 1/10/24 1/10/24 Nitrogen Oxides Data Concentration, ppmvd @ 3% O2 8.30 8.42 7.63 8.12 Permit Limit, ppmvd @ 3% O2 -- -- -- 9 Percent of Limit, % -- -- -- 90 Emission Rate, lb/hr 0.20 0.18 0.19 0.19 Permit Limit, lb/hr -- -- -- 0.54 Percent of Limit, % -- -- -- 35 9 of 97 Source Test Report Summary of Results AST-2024-0023 University of Utah – Salt Lake City, UT Page 2-3 Table 2-4: Summary of Results – Unit 7 Run Number Run 1 Run 2 Run 3 Average Date 1/10/24 1/10/24 1/10/24 Nitrogen Oxides Data Concentration, ppmvd @ 3% O2 8.33 8.47 7.93 8.24 Permit Limit, ppmvd @ 3% O2 -- -- -- 9 Percent of Limit, % -- -- -- 92 Emission Rate, lb/hr 0.19 0.19 0.20 0.19 Permit Limit, lb/hr -- -- -- 0.54 Percent of Limit, % -- -- -- 36 Table 2-5: Summary of Results – Gen 9 Boiler Run Number Run 1 Run 2 Run 3 Average Date 1/9/24 1/9/24 1/9/24 Nitrogen Oxides Data Concentration, ppmvd @ 3% O2 8.04 8.31 8.35 8.23 Permit Limit, ppmvd @ 3% O2 -- -- -- 9 Percent of Limit, % -- -- -- 91 Emission Rate, lb/hr 0.29 0.27 0.25 0.27 Permit Limit, lb/hr -- -- -- 0.79 Percent of Limit, % -- -- -- 34 10 of 97 Testing Methodology 11 of 97 Source Test Report Testing Methodology AST-2024-0023 University of Utah – Salt Lake City, UT Page 3-1 3.0 Testing Methodology The emission testing program was conducted in accordance with the test methods listed in Table 3-1. Method descriptions are provided below while quality assurance/quality control data is provided in Appendix C. Table 3-1: Source Testing Methodology Parameter U.S. EPA Reference Test Methods Notes/Remarks Oxygen 3A Instrumental Analysis Nitrogen Oxides 7E Instrumental Analysis Carbon Monoxide 10 Instrumental Analysis Volumetric Flow Rate / Mass Emission Factors 19 Fuel Factors/Heat Inputs Gas Dilution System Certification 205 -- 3.1 U.S. EPA Reference Test Method 3A – Oxygen/Carbon Dioxide The oxygen (O2) and carbon dioxide (CO2) testing was conducted in accordance with U.S. EPA Reference Test Method 3A. Data was collected online and reported in one-minute averages. The sampling system consisted of a stainless-steel probe, Teflon sample line(s), gas conditioning system and the identified gas analyzer. The gas conditioning system was a non-contact condenser used to remove moisture from the stack gas. If an unheated Teflon sample line was used, then a portable non-contact condenser was placed in the system directly after the probe. Otherwise, a heated Teflon sample line was used. The quality control measures are described in Section 3.6. 3.2 U.S. EPA Reference Test Method 7E – Nitrogen Oxides The nitrogen oxides (NOx) testing was conducted in accordance with U.S. EPA Reference Test Method 7E. Data was collected online and reported in one-minute averages. The sampling system consisted of a stainless-steel probe, Teflon sample line(s), gas conditioning system and the identified gas analyzer. The gas conditioning system was a non-contact condenser used to remove moisture from the stack gas. If an unheated Teflon sample line was used, then a portable non-contact condenser was placed in the system directly after the probe. Otherwise, a heated Teflon sample line was used. The quality control measures are described in Section 3.6. 3.3 U.S. EPA Reference Test Method 10 – Carbon Monoxide The carbon monoxide (CO) testing was conducted in accordance with U.S. EPA Reference Test Method 10. Data was collected online and reported in one-minute averages. The sampling system consisted of a stainless-steel probe, Teflon sample line(s), gas conditioning system, and the identified gas analyzer. The gas conditioning system was a non-contact condenser used to remove moisture from the gas. If an unheated Teflon sample line was used, then a portable non-contact condenser was placed in the system directly after the probe. Otherwise, a heated Teflon sample line was used. The quality control measures are described in Section 3.6. 3.4 U.S. EPA Reference Test Method 19 – Volumetric Flow Rate / Mass Emission Factors The gas volumetric flow rate was determined in accordance with U.S. EPA Reference Test Method 19 using the measured oxygen concentration, the published fuel factor, a calibrated gas meter and the fuel heating value. 12 of 97 Source Test Report Testing Methodology AST-2024-0023 University of Utah – Salt Lake City, UT Page 3-2 The pollutant concentrations were converted to mass emission factors (lb/MMBtu) using procedures outlined in U.S. EPA Reference Test Method 19. The published dry O2 based fuel factor (F-Factor) of 8,710 dscf/MMBtu for natural gas was used in the calculations. 3.5 U.S. EPA Reference Test Method 205 – Gas Dilution System Certification A calibration gas dilution system field check was conducted in accordance with U.S. EPA Reference Method 205. Multiple dilution rates and total gas flow rates were utilized to force the dilution system to perform two dilutions on each mass flow controller. The diluted calibration gases were sent directly to the analyzer, and the analyzer response recorded in an electronic field data sheet. The analyzer response agreed within 2% of the actual diluted gas concentration. A second Protocol 1 calibration gas, with a cylinder concentration within 10% of one of the gas divider settings described above, was introduced directly to the analyzer, and the analyzer response recorded in an electronic field data sheet. The cylinder concentration and the analyzer response agreed within 2%. These steps were repeated three (3) times. Copies of the Method 205 data can be found in the Quality Assurance/Quality Control Appendix. 3.6 Quality Assurance/Quality Control – U.S. EPA Reference Test Methods 3A, 7E, and 10 Cylinder calibration gases used met EPA Protocol 1 (+/- 2%) standards. Copies of all calibration gas certificates can be found in the Quality Assurance/Quality Control Appendix. Low Level gas was introduced directly to the analyzer. After adjusting the analyzer to the Low-Level gas concentration and once the analyzer reading was stable, the analyzer value was recorded. This process was repeated for the High-Level gas. For the Calibration Error Test, Low, Mid, and High Level calibration gases were sequentially introduced directly to the analyzer. All values were within 2.0 percent of the Calibration Span or 0.5 ppmv/% absolute difference. High or Mid Level gas (whichever was closer to the stack gas concentration) was introduced at the probe and the time required for the analyzer reading to reach 95 percent or 0.5 ppmv/% (whichever was less restrictive) of the gas concentration was recorded. The analyzer reading was observed until it reached a stable value, and this value was recorded. Next, Low Level gas was introduced at the probe and the time required for the analyzer reading to decrease to a value within 5.0 percent or 0.5 ppmv/% (whichever was less restrictive) was recorded. If the Low- Level gas was zero gas, the response was 0.5 ppmv/% or 5.0 percent of the upscale gas concentration (whichever was less restrictive). The analyzer reading was observed until it reached a stable value and this value was recorded. The measurement system response time and initial system bias were determined from these data. The System Bias was within 5.0 percent of the Calibration Span or 0.5 ppmv/% absolute difference. High or Mid Level gas (whichever was closer to the stack gas concentration) was introduced at the probe. After the analyzer response was stable, the value was recorded. Next, Low Level gas was introduced at the probe, and the analyzer value recorded once it reached a stable response. The System Bias was within 5.0 percent of the Calibration Span or 0.5 ppmv/% absolute difference or the data was invalidated and the Calibration Error Test and System Bias were repeated. Drift between pre- and post-run System Bias was within 3 percent of the Calibration Span or 0.5 ppmv/% absolute difference. If the drift exceeded 3 percent or 0.5 ppmv/%, the Calibration Error Test and System Bias were repeated. 13 of 97 Source Test Report Testing Methodology AST-2024-0023 University of Utah – Salt Lake City, UT Page 3-3 To determine the number of sampling points, a gas stratification check was conducted prior to initiating testing. The pollutant concentrations were measured at three and twelve traverse points (as described in Method 1). Each traverse point was sampled for a minimum of twice the system response time. If the pollutant concentration at each traverse point did not differ more than 5 percent or 0.5 ppmv/0.3% (whichever was less restrictive) of the average pollutant concentration, then single point sampling was conducted during the test runs. If the pollutant concentration did not meet these specifications but differed less than 10 percent or 1.0 ppmv/0.5% from the average concentration, then three (3) point sampling was conducted (stacks less than 7.8 feet in diameter - 16.7, 50.0 and 83.3 percent of the measurement line; stacks greater than 7.8 feet in diameter – 0.4, 1.0, and 2.0 meters from the stack wall). If the pollutant concentration differed by more than 10 percent or 1.0 ppmv/0.5% from the average concentration, then sampling was conducted at a minimum of twelve (12) traverse points. Copies of stratification check data can be found in the Quality Assurance/Quality Control Appendix. An NO2 – NO converter check was performed on the analyzer prior to initiating testing. An approximately 50 ppm nitrogen dioxide cylinder gas was introduced directly to the NOx analyzer and the instrument response was recorded in an electronic data sheet. The instrument response was within +/- 10 percent of the cylinder concentration. A Data Acquisition System with battery backup was used to record the instrument response in one (1) minute averages. The data was continuously stored as a *.CSV file in Excel format on the hard drive of a computer. At the completion of testing, the data was also saved to the Alliance server. All data was reviewed by the Field Team Leader before leaving the facility. Once arriving at Alliance’s office, all written and electronic data was relinquished to the report coordinator and then a final review was performed by the Project Manager. 14 of 97 Appendix A 15 of 97 Location: Source: Project No.: Run No. /Method Stack Gas Volumetric Flow Rate (Qs), dscfm 20.9 20.9 - CO2 where, HI 72.1 = Heat Input, MMBtu/hr FFactor 8,710 = fuel factor, dscf/MMBtu CO2 15.5 = oxygen concentration, % Qs 40,241 = dscfm O₂ - Outlet Concentration (C O₂), % dry CMA ( CM - C0 ) where, Cobs 15.47 = average analyzer value during test, % dry Co 0.01 = average of pretest & posttest zero responses, % dry CMA 10.00 = actual concentration of calibration gas, % dry CM 10.01 = average of pretest & posttest calibration responses, % dry CO₂15.46 = O₂ Concentration, % dry University of Utah - Salt Lake City, UT Unit 1 - Solar Taurus 70 CoGen (Turbine Only) AST-2024-0023 Run 1 / Method 3A HI x Fd x Qs = 60 CO₂ = ( Cobs - C0 ) x CO₂ - Outlet Concentration (C CO₂), % dry C M A ( CM - C 0 ) where, Cobs 3.18 Co 0.04 CMA 10.00 CM 9.93 CCO₂3.17 = average analyzer value during test, % dry = average of pretest & posttest zero responses, % dry = actual concentration of calibration gas, % dry = average of pretest & posttest calibration responses, % dry = CO₂ Concentration, % dry CCO₂ = ( Cobs - C0 ) x Example Calculations 16 of 97 Location: Source: Project No.: Run No. /Method CO - Outlet Concentration (C CO), ppmvd CMA ( CM - C0 ) where, Cobs 0.90 = average analyzer value during test, ppmvd Co -0.07 = average of pretest & posttest zero responses, ppmvd CMA 25.00 = actual concentration of calibration gas, ppmvd CM 24.91 = average of pretest & posttest calibration responses, ppmvd CCO 0.97 = CO Concentration, ppmvd CO - Outlet Concentration (C COc15), ppmvd @ 15% O₂ 20.9 - 15 20.9 - O₂ where, CCO 0.97 = CO - Outlet Concentration, ppmvd CO₂15.46 = oxygen concentration, % CCOc15 1.05 = ppmvd @15% O₂ CO - Outlet Emission Rate (ERCO), lb/hr where, CCO 0.97 = CO - Outlet Concentration, ppmvd MW 28.01 = CO molecular weight, g/g-mole Qs 40,241 = stack gas volumetric flow rate at standard conditions, dscfm ERCO 0.17 = lb/hr CO - Outlet Emission Factor (EFCOHI), lb/MMBtu ERCO HI where, ERCO 0.17 = CO - Outlet Emission Rate, lb/hr HI 72.10 = Heat Input, MMBtu/hr EFCOHI 0.0024 = lb/MMBtu University of Utah - Salt Lake City, UT Unit 1 - Solar Taurus 70 CoGen (Turbine Only) AST-2024-0023 Run 1 / Method 10 CCOc15 = CCO x CCO = ( Cobs - C0 ) x ERCO =CCO x MW x Qs x 60 x 28.32 24.04 x 1.0E06 x 453.592 EFCOHI = 𝑚𝑖𝑛 ℎ𝑟 𝐿 𝑓𝑡ଷ 𝐿 𝑔െ𝑚𝑜𝑙𝑒 𝑔 𝑙𝑏 Example Calculations 17 of 97 Location: Source: Project No.: Run No. /Method NOx - Outlet Concentration (C NOx), ppmvd CMA ( CM - C0 ) where, Cobs 3.22 = average analyzer value during test, ppmvd Co 0.06 = average of pretest & posttest zero responses, ppmvd CMA 25.00 = actual concentration of calibration gas, ppmvd CM 25.02 = average of pretest & posttest calibration responses, ppmvd CNOx 3.16 = NOx Concentration, ppmvd NOx - Outlet Concentration (C NOxc15), ppmvd @ 15% O₂ 20.9 - 15 20.9 - O₂ where, CNOx 3.16 = NOx - Outlet Concentration, ppmvd CO₂15.46 = oxygen concentration, % CNOxc15 3.43 = ppmvd @15% O₂ NOx - Outlet Emission Rate (ERNOx), lb/hr where, CNOx 3.16 = NOx - Outlet Concentration, ppmvd MW 46.0055 = NOx molecular weight, g/g-mole Qs 40,241 = stack gas volumetric flow rate at standard conditions, dscfm ERNOx 0.91 = lb/hr NOx - Outlet Emission Factor (EFNOxHI), lb/MMBtu ERNOx HI where, ERNOx 0.91 = NOx - Outlet Emission Rate, lb/hr HI 72.10 = Heat Input, MMBtu/hr EFNOxHI 0.013 = lb/MMBtu University of Utah - Salt Lake City, UT Unit 1 - Solar Taurus 70 CoGen (Turbine Only) AST-2024-0023 Run 1 / Method 7E CNOxc15 = CNOx x CNOx = ( Cobs - C0 ) x ERNOx =CNOx x MW x Qs x 60 x 28.32 24.04 x 1.0E06 x 453.592 EFNOxHI = 𝑚𝑖𝑛 ℎ𝑟 𝐿 𝑓𝑡ଷ 𝐿 𝑔െ𝑚𝑜𝑙𝑒 𝑔 𝑙𝑏 Example Calculations 18 of 97 Location: Source: Project No.: Run No. /Method Stack Gas Volumetric Flow Rate (Qs), dscfm 20.9 20.9 - CO2 where, HI 92.4 = Heat Input, MMBtu/hr FFactor 8,710 = fuel factor, dscf/MMBtu CO2 12.5 = oxygen concentration, % Qs 33,184 = dscfm O₂ - Outlet Concentration (C O₂), % dry CMA ( CM - C0 ) where, Cobs 12.53 = average analyzer value during test, % dry Co 0.06 = average of pretest & posttest zero responses, % dry CMA 10.00 = actual concentration of calibration gas, % dry CM 10.08 = average of pretest & posttest calibration responses, % dry CO₂12.45 = O₂ Concentration, % dry University of Utah - Salt Lake City, UT Unit 1 - Solar Taurus 70 CoGen (Turbine and WHRU Du AST-2024-0023 Run 1 / Method 3A HI x Fd x Qs = 60 CO₂ = ( Cobs - C0 ) x CO₂ - Outlet Concentration (C CO₂), % dry C M A ( CM - C 0 ) where, Cobs 4.88 Co 0.07 CMA 10.00 CM 9.96 CCO₂4.87 = average analyzer value during test, % dry = average of pretest & posttest zero responses, % dry = actual concentration of calibration gas, % dry = average of pretest & posttest calibration responses, % dry = CO₂ Concentration, % dry CCO₂ = ( Cobs - C0 ) x Example Calculations 19 of 97 Location: Source: Project No.: Run No. /Method CO - Outlet Concentration (C CO), ppmvd CMA ( CM - C0 ) where, Cobs 12.47 = average analyzer value during test, ppmvd Co -0.25 = average of pretest & posttest zero responses, ppmvd CMA 25.00 = actual concentration of calibration gas, ppmvd CM 25.25 = average of pretest & posttest calibration responses, ppmvd CCO 12.47 = CO Concentration, ppmvd CO - Outlet Concentration (C COc15), ppmvd @ 15% O₂ 20.9 - 15 20.9 - O₂ where, CCO 12.47 = CO - Outlet Concentration, ppmvd CO₂12.45 = oxygen concentration, % CCOc15 8.71 = ppmvd @15% O₂ CO - Outlet Emission Rate (ERCO), lb/hr where, CCO 12.47 = CO - Outlet Concentration, ppmvd MW 28.01 = CO molecular weight, g/g-mole Qs 33,184 = stack gas volumetric flow rate at standard conditions, dscfm ERCO 1.81 = lb/hr CO - Outlet Emission Factor (EFCOHI), lb/MMBtu ERCO HI where, ERCO 1.81 = CO - Outlet Emission Rate, lb/hr HI 92.42 = Heat Input, MMBtu/hr EFCOHI 0.020 = lb/MMBtu University of Utah - Salt Lake City, UT Unit 1 - Solar Taurus 70 CoGen (Turbine and WHRU Du AST-2024-0023 Run 1 / Method 10 CCOc15 = CCO x CCO = ( Cobs - C0 ) x ERCO =CCO x MW x Qs x 60 x 28.32 24.04 x 1.0E06 x 453.592 EFCOHI = 𝑚𝑖𝑛 ℎ𝑟 𝐿 𝑓𝑡ଷ 𝐿 𝑔െ𝑚𝑜𝑙𝑒 𝑔 𝑙𝑏 Example Calculations 20 of 97 Location: Source: Project No.: Run No. /Method NOx - Outlet Concentration (C NOx), ppmvd CMA ( CM - C0 ) where, Cobs 10.85 = average analyzer value during test, ppmvd Co 0.17 = average of pretest & posttest zero responses, ppmvd CMA 25.00 = actual concentration of calibration gas, ppmvd CM 25.02 = average of pretest & posttest calibration responses, ppmvd CNOx 10.75 = NOx Concentration, ppmvd NOx - Outlet Concentration (C NOxc15), ppmvd @ 15% O₂ 20.9 - 15 20.9 - O₂ where, CNOx 10.75 = NOx - Outlet Concentration, ppmvd CO₂12.45 = oxygen concentration, % CNOxc15 7.51 = ppmvd @15% O₂ NOx - Outlet Emission Rate (ERNOx), lb/hr where, CNOx 10.75 = NOx - Outlet Concentration, ppmvd MW 46.0055 = NOx molecular weight, g/g-mole Qs 33,184 = stack gas volumetric flow rate at standard conditions, dscfm ERNOx 2.56 = lb/hr NOx - Outlet Emission Factor (EFNOxHI), lb/MMBtu ERNOx HI where, ERNOx 2.56 = NOx - Outlet Emission Rate, lb/hr HI 92.42 = Heat Input, MMBtu/hr EFNOxHI 0.028 = lb/MMBtu University of Utah - Salt Lake City, UT Unit 1 - Solar Taurus 70 CoGen (Turbine and WHRU Du AST-2024-0023 Run 1 / Method 7E CNOxc15 = CNOx x CNOx = ( Cobs - C0 ) x ERNOx =CNOx x MW x Qs x 60 x 28.32 24.04 x 1.0E06 x 453.592 EFNOxHI = 𝑚𝑖𝑛 ℎ𝑟 𝐿 𝑓𝑡ଷ 𝐿 𝑔െ𝑚𝑜𝑙𝑒 𝑔 𝑙𝑏 Example Calculations 21 of 97 Location: Source: Project No.: Run No. /Method Stack Gas Volumetric Flow Rate (Qs), dscfm 20.9 20.9 - CO2 where, HI 20.1 = Heat Input, MMBtu/hr FFactor 8,710 = fuel factor, dscf/MMBtu CO2 12.5 = oxygen concentration, % Qs 7,256 = dscfm O₂ - Outlet Concentration (C O₂), % dry CMA ( CM - C0 ) where, Cobs 12.46 = average analyzer value during test, % dry Co 0.01 = average of pretest & posttest zero responses, % dry CMA 10.00 = actual concentration of calibration gas, % dry CM 9.98 = average of pretest & posttest calibration responses, % dry CO₂12.50 = O₂ Concentration, % dry University of Utah - Salt Lake City, UT Unit 6 AST-2024-0023 Run 1 / Method 3A HI x Fd x Qs = 60 CO₂ = ( Cobs - C0 ) x CO₂ - Outlet Concentration (C CO₂), % dry C M A ( CM - C 0 ) where, Cobs 4.83 Co 0.03 CMA 10.00 CM 9.87 CCO₂4.88 = average analyzer value during test, % dry = average of pretest & posttest zero responses, % dry = actual concentration of calibration gas, % dry = average of pretest & posttest calibration responses, % dry = CO₂ Concentration, % dry CCO₂ = ( Cobs - C0 ) x Example Calculations 22 of 97 Location: Source: Project No.: Run No. /Method NOx - Outlet Concentration (C NOx), ppmvd CMA ( CM - C0 ) where, Cobs 3.93 = average analyzer value during test, ppmvd Co 0.05 = average of pretest & posttest zero responses, ppmvd CMA 15.00 = actual concentration of calibration gas, ppmvd CM 15.01 = average of pretest & posttest calibration responses, ppmvd CNOx 3.90 = NOx Concentration, ppmvd NOx - Outlet Concentration (C NOxc3), ppmvd @ 3% O₂ 20.9 - 3 20.9 - O₂ where, CNOx 3.90 = NOx - Outlet Concentration, ppmvd CO₂12.50 = oxygen concentration, % CNOxc3 8.30 = ppmvd @3% O₂ NOx - Outlet Emission Rate (ERNOx), lb/hr where, CNOx 3.90 = NOx - Outlet Concentration, ppmvd MW 46.0055 = NOx molecular weight, g/g-mole Qs 7,256 = stack gas volumetric flow rate at standard conditions, dscfm ERNOx 0.20 = lb/hr NOx - Outlet Emission Factor (EFNOxHI), lb/MMBtu ERNOx HI where, ERNOx 0.20 = NOx - Outlet Emission Rate, lb/hr HI 20 = Heat Input, MMBtu/hr EFNOxHI 0.0101 = lb/MMBtu University of Utah - Salt Lake City, UT Unit 6 AST-2024-0023 Run 1 / Method 7E CNOxc3 = CNOx x CNOx = ( Cobs - C0 ) x ERNOx =CNOx x MW x Qs x 60 x 28.32 24.04 x 1.0E06 x 453.592 EFNOxHI = 𝑚𝑖𝑛 ℎ𝑟 𝐿 𝑓𝑡ଷ 𝐿 𝑔െ𝑚𝑜𝑙𝑒 𝑔 𝑙𝑏 Example Calculations 23 of 97 Location: Source: Project No.: Run No. /Method Stack Gas Volumetric Flow Rate (Qs), dscfm 20.9 20.9 - CO2 where, HI 18.9 = Heat Input, MMBtu/hr FFactor 8,710 = fuel factor, dscf/MMBtu CO2 11.6 = oxygen concentration, % Qs 6,176 = dscfm O₂ - Outlet Concentration (C O₂), % dry CMA ( CM - C0 ) where, Cobs 11.62 = average analyzer value during test, % dry Co 0.01 = average of pretest & posttest zero responses, % dry CMA 10.00 = actual concentration of calibration gas, % dry CM 10.01 = average of pretest & posttest calibration responses, % dry CO₂11.62 = O₂ Concentration, % dry University of Utah - Salt Lake City, UT Unit 7 AST-2024-0023 Run 1 / Method 3A HI x Fd x Qs = 60 CO₂ = ( Cobs - C0 ) x CO₂ - Outlet Concentration (C CO₂), % dry C M A ( CM - C 0 ) where, Cobs 5.32 Co 0.05 CMA 10.00 CM 9.93 CCO₂5.34 = average analyzer value during test, % dry = average of pretest & posttest zero responses, % dry = actual concentration of calibration gas, % dry = average of pretest & posttest calibration responses, % dry = CO₂ Concentration, % dry CCO₂ = ( Cobs - C0 ) x Example Calculations 24 of 97 Location: Source: Project No.: Run No. /Method NOx - Outlet Concentration (C NOx), ppmvd CMA ( CM - C0 ) where, Cobs 4.34 = average analyzer value during test, ppmvd Co 0.03 = average of pretest & posttest zero responses, ppmvd CMA 15.00 = actual concentration of calibration gas, ppmvd CM 15.00 = average of pretest & posttest calibration responses, ppmvd CNOx 4.32 = NOx Concentration, ppmvd NOx - Outlet Concentration (C NOxc3), ppmvd @ 3% O₂ 20.9 - 3 20.9 - O₂ where, CNOx 4.32 = NOx - Outlet Concentration, ppmvd CO₂11.62 = oxygen concentration, % CNOxc3 8.33 = ppmvd @3% O₂ NOx - Outlet Emission Rate (ERNOx), lb/hr where, CNOx 4.32 = NOx - Outlet Concentration, ppmvd MW 46.0055 = NOx molecular weight, g/g-mole Qs 6,176 = stack gas volumetric flow rate at standard conditions, dscfm ERNOx 0.19 = lb/hr NOx - Outlet Emission Factor (EFNOxHI), lb/MMBtu ERNOx HI where, ERNOx 0.19 = NOx - Outlet Emission Rate, lb/hr HI 19 = Heat Input, MMBtu/hr EFNOxHI 0.0101 = lb/MMBtu University of Utah - Salt Lake City, UT Unit 7 AST-2024-0023 Run 1 / Method 7E CNOxc3 = CNOx x CNOx = ( Cobs - C0 ) x ERNOx =CNOx x MW x Qs x 60 x 28.32 24.04 x 1.0E06 x 453.592 EFNOxHI = 𝑚𝑖𝑛 ℎ𝑟 𝐿 𝑓𝑡ଷ 𝐿 𝑔െ𝑚𝑜𝑙𝑒 𝑔 𝑙𝑏 Example Calculations 25 of 97 Location: Source: Project No.: Run No. /Method Stack Gas Volumetric Flow Rate (Qs), dscfm 20.9 20.9 - CO2 where, HI 29.54 = Heat Input, MMBtu/hr FFactor 8,710 = fuel factor, dscf/MMBtu CO2 11.8 = oxygen concentration, % Qs 9,797 = dscfm O₂ - Outlet Concentration (C O₂), % dry CMA ( CM - C0 ) where, Cobs 11.73 = average analyzer value during test, % dry Co 0.00 = average of pretest & posttest zero responses, % dry CMA 10.00 = actual concentration of calibration gas, % dry CM 9.99 = average of pretest & posttest calibration responses, % dry CO₂11.75 = O₂ Concentration, % dry University of Utah - Salt Lake City, UT Gen 9 Boiler AST-2024-0023 Run 1 / Method 3A HI x Fd x Qs = 60 CO₂ = ( Cobs - C0 ) x CO₂ - Outlet Concentration (C CO₂), % dry C M A ( CM - C 0 ) where, Cobs 5.32 Co 0.05 CMA 10.00 CM 9.93 CCO₂5.34 = average analyzer value during test, % dry = average of pretest & posttest zero responses, % dry = actual concentration of calibration gas, % dry = average of pretest & posttest calibration responses, % dry = CO₂ Concentration, % dry CCO₂ = ( Cobs - C0 ) x Example Calculations 26 of 97 Location: Source: Project No.: Run No. /Method NOx - Outlet Concentration (C NOx), ppmvd CMA ( CM - C0 ) where, Cobs 4.13 = average analyzer value during test, ppmvd Co 0.01 = average of pretest & posttest zero responses, ppmvd CMA 15.00 = actual concentration of calibration gas, ppmvd CM 15.06 = average of pretest & posttest calibration responses, ppmvd CNOx 4.11 = NOx Concentration, ppmvd NOx - Outlet Concentration (C NOxc3), ppmvd @ 3% O₂ 20.9 - 3 20.9 - O₂ where, CNOx 4.11 = NOx - Outlet Concentration, ppmvd CO₂11.75 = oxygen concentration, % CNOxc3 8.04 = ppmvd @3% O₂ NOx - Outlet Emission Rate (ERNOx), lb/hr where, CNOx 4.11 = NOx - Outlet Concentration, ppmvd MW 46.0055 = NOx molecular weight, g/g-mole Qs 9,797 = stack gas volumetric flow rate at standard conditions, dscfm ERNOx 0.29 = lb/hr NOx - Outlet Emission Factor (EFNOxHI), lb/MMBtu ERNOx HI where, ERNOx 0.29 = NOx - Outlet Emission Rate, lb/hr HI 30 = Heat Input, MMBtu/hr EFNOxHI 0.0098 = lb/MMBtu University of Utah - Salt Lake City, UT Gen 9 Boiler AST-2024-0023 Run 1 / Method 7E CNOxc3 = CNOx x CNOx = ( Cobs - C0 ) x ERNOx =CNOx x MW x Qs x 60 x 28.32 24.04 x 1.0E06 x 453.592 EFNOxHI = 𝑚𝑖𝑛 ℎ𝑟 𝐿 𝑓𝑡ଷ 𝐿 𝑔െ𝑚𝑜𝑙𝑒 𝑔 𝑙𝑏 Example Calculations 27 of 97 Appendix B 28 of 97 Solar Taurus 70 CoGen 29 of 97 Emissions Calculations Location Source Project No. Run Number Run 1 Run 2 Run 3 Average Date 1/9/24 1/9/24 1/9/24 -- Start Time 8:44 9:58 11:09 -- Stop Time 9:44 10:58 12:09 -- Turbine Manufacturer Turbine Model Turbine Serial Number Turbine Hour Meter Reading EMR Fuel Factor (O2 dry), dscf/MMBtu Fd 8,710 8,710 8,710 8,710 Heat Input, MMBtu/hr HI 72.1 82.3 72.3 75.6 Ambient Temperature TAmb 24 25 27 25 Relative Humidity, % RH 62 62 62 62 Barometric Pressure, in. Hg Pb 25.12 25.12 25.15 25.13 Volumetric Flow Rate (M19), dscfm Qs 40,241 45,769 40,002 42,004 O₂ Concentration, % dry CO₂15.46 15.44 15.42 15.44 CO₂ Concentration, % dry CCO₂3.17 3.18 3.19 3.18 CO Concentration, ppmvd CCO 0.97 0.92 0.95 0.95 CO Concentration, ppmvd @ 15 % O₂CCOc15 1.05 0.99 1.02 1.02 CO Emission Rate, lb/hr ERCO 0.17 0.18 0.17 0.17 CO Emission Factor, lb/MMBtu (HI)EFCO HI 0.0024 0.0022 0.0023 0.0023 NOx Concentration, ppmvd CNOx 3.16 3.56 4.01 3.58 NOx Concentration, ppmvd @ 15 % O₂CNOxc15 3.43 3.85 4.32 3.87 NOx Emission Rate, lb/hr ERNOx 0.91 1.2 1.2 1.1 NOx Emission Factor, lb/MMBtu (HI)EFNOx HI 0.013 0.014 0.016 0.014 Turbine Data -- Input Data - Outlet Calculated Data - Outlet University of Utah - Salt Lake City, UT Unit 1 - Solar Taurus 70 CoGen (Turbine Only) AST-2024-0023 Solar Taurus 70 T7800S 8290 30 of 97 Method 1 Data Location Source Project No. Date: Vertical Circular 59.00 in 6.00 in 53.00 in 15.32 ft2 2 1 14.0 ft 3.2 (must be ≥ 0.5) 30.0 ft 6.8 (must be ≥ 2) 12 12 Measurer (Initial and Date):SPR 1/8/24 Reviewer (Initial and Date):RJL 1/8/24 23456789101112 1 14.6 -- 6.7 -- 4.4 -- 3.2 -- 2.6 -- 2.1 1 4.4 2.33 8.33 2 85.4 -- 25.0 -- 14.6 -- 10.5 -- 8.2 -- 6.7 2 14.6 7.74 13.74 3 -- -- 75.0 -- 29.6 -- 19.4 -- 14.6 -- 11.8 3 29.6 15.69 21.69 4 -- -- 93.3 -- 70.4 -- 32.3 -- 22.6 -- 17.7 4 70.4 37.31 43.31 5 -- -- -- -- 85.4 -- 67.7 -- 34.2 -- 25.0 5 85.4 45.26 51.26 6 -- -- -- -- 95.6 -- 80.6 -- 65.8 -- 35.6 6 95.6 50.67 56.67 7 -- -- -- -- -- -- 89.5 -- 77.4 -- 64.4 7 -- -- -- 8 -- -- -- -- -- -- 96.8 -- 85.4 -- 75.0 8 -- -- -- 9 -- -- -- -- -- -- -- -- 91.8 -- 82.3 9 -- -- -- 10 -- -- -- -- -- -- -- -- 97.4 -- 88.2 10 -- -- -- 11 -- -- -- -- -- -- -- -- -- -- 93.3 11 -- -- -- 12 -- -- -- -- -- -- -- -- -- -- 97.9 12 -- -- -- *Percent of stack diameter from inside wall to traverse point. A = 14 ft. B = 30 ft. Depth of Duct = 53 in. Number of traverse points on a diameter Stack Diagram Cross Sectional Area Distance from outside of port LOCATION OF TRAVERSE POINTS Traverse Point % of Diameter Distance from inside wall No. of Test Ports: Number of Readings per Point: Distance A: Distance A Duct Diameters: Distance B: Distance B Duct Diameters: Minimum Number of Traverse Points: Actual Number of Traverse Points: CIRCULAR DUCT Cross Sectional Area of Duct: University of Utah - Salt Lake City, UT Unit 1 - Solar Taurus 70 CoGen (Turbine Only) AST-2024-0023 01/09/24 Stack Parameters Duct Orientation: Duct Design: Distance from Far Wall to Outside of Port: Nipple Length: Depth of Duct: Upstream Disturbance Downstream Disturbance B A 31 of 97 Run 1 - RM Data Location: Source: Project No.: Date: Time O₂ - Outlet CO₂ - Outlet CO - Outlet NOx - Outlet Unit % dry % dry ppmvd ppmvd Status Valid Valid Valid Valid Uncorrected Run Average (Cobs)15.47 3.18 0.90 3.22 Cal Gas Concentration (CMA)10.00 10.00 25.00 25.00 Pretest System Zero Response 0.00 0.04 -0.05 0.05 Posttest System Zero Response 0.01 0.04 -0.08 0.06 Average Zero Response (Co)0.01 0.04 -0.07 0.06 Pretest System Cal Response 10.00 9.93 24.98 25.03 Posttest System Cal Response 10.01 9.93 24.84 25.01 Average Cal Response (CM)10.01 9.93 24.91 25.02 Corrected Run Average (Corr)15.46 3.17 0.97 3.16 8:44 15.49 3.18 1.02 2.90 8:45 15.48 3.18 0.90 2.86 8:46 15.48 3.17 0.93 2.89 8:47 15.48 3.17 0.99 2.91 8:48 15.48 3.17 1.00 2.94 8:49 15.48 3.18 0.98 2.96 8:50 15.48 3.18 0.96 3.00 8:51 15.48 3.17 0.97 2.99 8:52 15.48 3.18 0.93 3.04 8:53 15.47 3.18 0.94 3.06 8:54 15.47 3.18 0.97 3.08 8:55 15.47 3.18 0.94 3.07 8:56 15.48 3.18 0.96 3.06 8:57 15.47 3.18 0.94 3.11 8:58 15.47 3.18 0.94 3.16 8:59 15.47 3.18 0.96 3.11 9:00 15.46 3.18 0.96 3.15 9:01 15.47 3.18 1.00 3.13 9:02 15.48 3.17 0.96 3.12 9:03 15.48 3.17 0.92 3.12 9:04 15.47 3.17 0.93 3.17 9:05 15.47 3.17 0.96 3.20 9:06 15.47 3.17 0.95 3.17 9:07 15.47 3.17 0.94 3.12 9:08 15.47 3.17 0.96 3.18 9:09 15.47 3.18 0.96 3.19 9:10 15.47 3.18 0.92 3.21 9:11 15.47 3.17 0.86 3.18 9:12 15.47 3.17 0.86 3.19 9:13 15.47 3.17 0.91 3.24 9:14 15.47 3.18 0.97 3.22 9:15 15.47 3.17 0.89 3.20 9:16 15.46 3.17 0.90 3.27 9:17 15.47 3.17 0.91 3.23 9:18 15.47 3.17 0.95 3.23 9:19 15.47 3.18 0.88 3.24 9:20 15.47 3.17 0.86 3.23 9:21 15.47 3.18 0.93 3.25 9:22 15.46 3.18 0.94 3.31 9:23 15.47 3.18 0.90 3.33 9:24 15.46 3.18 0.86 3.34 9:25 15.46 3.18 0.83 3.38 9:26 15.46 3.18 0.84 3.37 9:27 15.46 3.18 0.89 3.44 9:28 15.46 3.18 0.89 3.43 9:29 15.46 3.18 0.81 3.41 9:30 15.47 3.18 0.81 3.40 9:31 15.46 3.18 0.81 3.36 9:32 15.46 3.17 0.82 3.36 9:33 15.47 3.18 0.82 3.34 9:34 15.46 3.18 0.84 3.40 9:35 15.46 3.18 0.83 3.45 9:36 15.46 3.18 0.84 3.42 9:37 15.46 3.18 0.82 3.44 9:38 15.46 3.18 0.81 3.42 9:39 15.46 3.18 0.83 3.44 9:40 15.47 3.17 0.80 3.40 9:41 15.47 3.18 0.83 3.37 9:42 15.46 3.17 0.82 3.34 9:43 15.46 3.17 0.81 3.39 University of Utah - Salt Lake City, UT Unit 1 - Solar Taurus 70 CoGen (Turbine Only) AST-2024-0023 1/9/24 32 of 97 Run 2 - RM Data Location: Source: Project No.: Date: Time O₂ - Outlet CO₂ - Outlet CO - Outlet NOx - Outlet Unit % dry % dry ppmvd ppmvd Status Valid Valid Valid Valid Uncorrected Run Average (Cobs)15.45 3.18 0.81 3.60 Cal Gas Concentration (CMA)10.00 10.00 25.00 25.00 Pretest System Zero Response 0.01 0.04 -0.08 0.06 Posttest System Zero Response 0.02 0.05 -0.13 0.07 Average Zero Response (Co)0.02 0.05 -0.11 0.07 Pretest System Cal Response 10.01 9.93 24.84 25.01 Posttest System Cal Response 10.01 9.93 24.85 24.77 Average Cal Response (CM)10.01 9.93 24.85 24.89 Corrected Run Average (Corr)15.44 3.18 0.92 3.56 9:58 15.46 3.18 0.84 3.28 9:59 15.47 3.18 0.82 3.28 10:00 15.46 3.18 0.86 3.42 10:01 15.46 3.18 0.82 3.40 10:02 15.46 3.18 0.84 3.43 10:03 15.46 3.18 0.83 3.47 10:04 15.46 3.18 0.83 3.48 10:05 15.47 3.18 0.81 3.49 10:06 15.46 3.18 0.81 3.49 10:07 15.46 3.18 0.79 3.51 10:08 15.46 3.18 0.80 3.52 10:09 15.47 3.18 0.80 3.52 10:10 15.47 3.18 0.81 3.48 10:11 15.46 3.18 0.80 3.48 10:12 15.46 3.18 0.80 3.48 10:13 15.46 3.18 0.81 3.51 10:14 15.47 3.18 0.82 3.51 10:15 15.46 3.18 0.82 3.49 10:16 15.46 3.18 0.82 3.55 10:17 15.46 3.18 0.83 3.53 10:18 15.46 3.18 0.84 3.49 10:19 15.47 3.18 0.80 3.49 10:20 15.47 3.18 0.81 3.49 10:21 15.47 3.18 0.80 3.41 10:22 15.46 3.18 0.81 3.48 10:23 15.46 3.18 0.87 3.52 10:24 15.46 3.18 0.84 3.51 10:25 15.46 3.18 0.87 3.48 10:26 15.46 3.18 0.81 3.51 10:27 15.46 3.18 0.80 3.48 10:28 15.46 3.18 0.80 3.45 10:29 15.46 3.18 0.82 3.51 10:30 15.46 3.18 0.81 3.50 10:31 15.46 3.18 0.79 3.49 10:32 15.46 3.18 0.80 3.48 10:33 15.46 3.18 0.82 3.52 10:34 15.45 3.19 0.88 3.62 10:35 15.44 3.19 0.80 3.64 10:36 15.44 3.19 0.84 3.69 10:37 15.44 3.19 0.78 3.67 10:38 15.44 3.19 0.76 3.80 10:39 15.44 3.19 0.83 3.68 10:40 15.44 3.18 0.80 3.75 10:41 15.44 3.18 0.76 3.71 10:42 15.44 3.19 0.80 3.75 10:43 15.44 3.18 0.81 3.74 10:44 15.42 3.20 0.88 3.84 10:45 15.43 3.19 0.79 3.86 10:46 15.44 3.18 0.74 3.75 10:47 15.44 3.19 0.81 3.79 10:48 15.44 3.19 0.77 3.78 10:49 15.43 3.19 0.78 3.79 10:50 15.43 3.20 0.79 3.85 10:51 15.44 3.19 0.76 3.82 10:52 15.44 3.19 0.76 3.82 10:53 15.43 3.19 0.79 3.83 10:54 15.44 3.19 0.74 3.82 10:55 15.42 3.20 0.83 3.89 10:56 15.42 3.20 0.80 3.91 10:57 15.43 3.19 0.75 3.93 University of Utah - Salt Lake City, UT Unit 1 - Solar Taurus 70 CoGen (Turbine Only) AST-2024-0023 1/9/24 33 of 97 Run 3 - RM Data Location: Source: Project No.: Date: Time O₂ - Outlet CO₂ - Outlet CO - Outlet NOx - Outlet Unit % dry % dry ppmvd ppmvd Status Valid Valid Valid Valid Uncorrected Run Average (Cobs)15.41 3.18 0.80 4.05 Cal Gas Concentration (CMA)10.00 10.00 25.00 25.00 Pretest System Zero Response 0.02 0.05 -0.13 0.07 Posttest System Zero Response 0.03 0.03 -0.17 0.09 Average Zero Response (Co)0.03 0.04 -0.15 0.08 Pretest System Cal Response 10.01 9.93 24.85 24.77 Posttest System Cal Response 10.00 9.89 24.77 24.78 Average Cal Response (CM)10.01 9.91 24.81 24.78 Corrected Run Average (Corr)15.42 3.19 0.95 4.01 11:09 15.40 3.18 1.10 3.99 11:10 15.41 3.19 0.69 3.85 11:11 15.40 3.19 0.74 3.89 11:12 15.41 3.19 0.78 3.96 11:13 15.41 3.19 0.72 4.07 11:14 15.41 3.19 0.72 4.06 11:15 15.41 3.19 0.73 4.07 11:16 15.41 3.19 0.76 4.05 11:17 15.42 3.19 0.75 4.03 11:18 15.42 3.19 0.78 4.07 11:19 15.42 3.19 0.79 3.98 11:20 15.42 3.18 0.82 4.02 11:21 15.42 3.18 0.82 4.06 11:22 15.42 3.18 0.81 4.02 11:23 15.42 3.18 0.77 3.98 11:24 15.42 3.19 0.78 3.96 11:25 15.42 3.18 0.76 3.98 11:26 15.42 3.18 0.76 3.95 11:27 15.42 3.18 0.74 3.96 11:28 15.43 3.18 0.73 3.91 11:29 15.42 3.18 0.74 3.97 11:30 15.42 3.18 0.73 3.99 11:31 15.42 3.19 0.72 3.95 11:32 15.41 3.19 0.74 4.02 11:33 15.42 3.18 0.72 3.98 11:34 15.42 3.18 0.73 3.98 11:35 15.41 3.19 0.73 3.98 11:36 15.41 3.19 0.73 4.00 11:37 15.41 3.19 0.73 3.99 11:38 15.41 3.18 0.73 4.00 11:39 15.41 3.18 0.74 4.07 11:40 15.40 3.19 0.82 4.11 11:41 15.40 3.19 0.80 4.10 11:42 15.41 3.18 0.81 4.09 11:43 15.41 3.19 0.84 4.08 11:44 15.41 3.18 0.79 4.05 11:45 15.41 3.19 0.79 4.04 11:46 15.40 3.19 0.83 4.06 11:47 15.40 3.19 0.77 4.10 11:48 15.41 3.18 0.75 4.11 11:49 15.41 3.18 0.72 4.02 11:50 15.41 3.19 0.85 4.03 11:51 15.40 3.19 0.85 4.14 11:52 15.40 3.19 0.77 4.08 11:53 15.41 3.19 0.74 4.03 11:54 15.41 3.19 0.84 4.00 11:55 15.41 3.18 0.77 3.97 11:56 15.41 3.19 0.80 4.00 11:57 15.41 3.18 0.80 4.03 11:58 15.41 3.18 0.81 4.05 11:59 15.41 3.18 0.79 4.00 12:00 15.40 3.18 0.84 4.09 12:01 15.40 3.18 0.86 4.13 12:02 15.40 3.19 0.90 4.11 12:03 15.40 3.18 0.91 4.15 12:04 15.40 3.18 0.91 4.19 12:05 15.40 3.18 0.96 4.25 12:06 15.41 3.18 0.98 4.26 12:07 15.41 3.17 1.03 4.31 12:08 15.40 3.18 1.09 4.37 University of Utah - Salt Lake City, UT Unit 1 - Solar Taurus 70 CoGen (Turbine Only) AST-2024-0023 1/9/24 34 of 97 Rentech Waste Heat Recovery 35 of 97 Emissions Calculations Location Source Project No. Run Number Run 1 Run 2 Run 3 Average Date 1/8/24 1/8/24 1/8/24 -- Start Time 12:48 14:03 15:14 -- Stop Time 13:48 15:03 16:14 -- Turbine Manufacturer Turbine Model Turbine Serial Number Turbine Hour Meter Reading EMR Fuel Factor (O2 dry), dscf/MMBtu Fd 8,710 8,710 8,710 8,710 Heat Input, MMBtu/hr HI 92.42 92.52 90.83 92 Ambient Temperature TAmb 28 30 31 30 Relative Humidity, % RH 62 62 62 62 Barometric Pressure, in. Hg Pb 25.14 25.14 25.15 25.14 Volumetric Flow Rate (M19), dscfm Qs 33,184 33,064 32,888 33,045 O₂ Concentration, % dry CO₂12.45 12.41 12.52 12.46 CO₂ Concentration, % dry CCO₂4.87 4.89 4.84 4.87 CO Concentration, ppmvd CCO 12.47 12.44 12.53 12.48 CO Concentration, ppmvd @ 15 % O₂CCOc15 8.71 8.65 8.82 8.73 CO Emission Rate, lb/hr ERCO 1.8 1.8 1.8 1.8 CO Emission Factor, lb/MMBtu (HI)EFCO HI 0.020 0.019 0.020 0.020 NOx Concentration, ppmvd CNOx 10.75 11.09 10.99 10.94 NOx Concentration, ppmvd @ 15 % O₂CNOxc15 7.51 7.70 7.73 7.65 NOx Emission Rate, lb/hr ERNOx 2.6 2.6 2.6 2.6 NOx Emission Factor, lb/MMBtu (HI)EFNOx HI 0.028 0.028 0.029 0.028 Turbine Data 3,133 Input Data - Outlet Calculated Data - Outlet University of Utah - Salt Lake City, UT Unit 1 - Solar Taurus 70 CoGen (Turbine and WHRU Duct Burner) AST-2024-0023 Solar Taurus 70 T7800S 8290 36 of 97 Method 1 Data Location Source Project No. Date: Vertical Circular 59.00 in 6.00 in 53.00 in 15.32 ft2 2 1 14.0 ft 3.2 (must be ≥ 0.5) 30.0 ft 6.8 (must be ≥ 2) 12 12 Measurer (Initial and Date):SPR 1/8/24 Reviewer (Initial and Date):RJL 1/8/24 23456789101112 1 14.6 -- 6.7 -- 4.4 -- 3.2 -- 2.6 -- 2.1 1 4.4 2.33 8.33 2 85.4 -- 25.0 -- 14.6 -- 10.5 -- 8.2 -- 6.7 2 14.6 7.74 13.74 3 -- -- 75.0 -- 29.6 -- 19.4 -- 14.6 -- 11.8 3 29.6 15.69 21.69 4 -- -- 93.3 -- 70.4 -- 32.3 -- 22.6 -- 17.7 4 70.4 37.31 43.31 5 -- -- -- -- 85.4 -- 67.7 -- 34.2 -- 25.0 5 85.4 45.26 51.26 6 -- -- -- -- 95.6 -- 80.6 -- 65.8 -- 35.6 6 95.6 50.67 56.67 7 -- -- -- -- -- -- 89.5 -- 77.4 -- 64.4 7 -- -- -- 8 -- -- -- -- -- -- 96.8 -- 85.4 -- 75.0 8 -- -- -- 9 -- -- -- -- -- -- -- -- 91.8 -- 82.3 9 -- -- -- 10 -- -- -- -- -- -- -- -- 97.4 -- 88.2 10 -- -- -- 11 -- -- -- -- -- -- -- -- -- -- 93.3 11 -- -- -- 12 -- -- -- -- -- -- -- -- -- -- 97.9 12 -- -- -- *Percent of stack diameter from inside wall to traverse point. A = 14 ft. B = 30 ft. Depth of Duct = 53 in. Number of traverse points on a diameter Stack Diagram Cross Sectional Area Distance from outside of port LOCATION OF TRAVERSE POINTS Traverse Point % of Diameter Distance from inside wall No. of Test Ports: Number of Readings per Point: Distance A: Distance A Duct Diameters: Distance B: Distance B Duct Diameters: Minimum Number of Traverse Points: Actual Number of Traverse Points: CIRCULAR DUCT Cross Sectional Area of Duct: University of Utah - Salt Lake City, UT Unit 1 - Solar Taurus 70 CoGen (Turbine and WHRU Duct Burner) AST-2024-0023 01/08/24 Stack Parameters Duct Orientation: Duct Design: Distance from Far Wall to Outside of Port: Nipple Length: Depth of Duct: Upstream Disturbance Downstream Disturbance B A 37 of 97 Run 1 - RM Data Location: Source: Project No.: Date: Time O₂ - Outlet CO₂ - Outlet CO - Outlet NOx - Outlet Unit % dry % dry ppmvd ppmvd Status Valid Valid Valid Valid Uncorrected Run Average (Cobs)12.53 4.88 12.47 10.85 Cal Gas Concentration (CMA)10.00 10.00 25.00 25.00 Pretest System Zero Response 0.03 0.05 -0.17 0.24 Posttest System Zero Response 0.08 0.09 -0.32 0.09 Average Zero Response (Co)0.06 0.07 -0.25 0.17 Pretest System Cal Response 10.05 9.94 25.52 25.05 Posttest System Cal Response 10.10 9.98 24.97 24.98 Average Cal Response (CM)10.08 9.96 25.25 25.02 Corrected Run Average (Corr)12.45 4.87 12.47 10.75 12:48 12.55 4.87 12.70 10.43 12:49 12.56 4.87 12.50 10.51 12:50 12.60 4.83 12.59 10.40 12:51 12.61 4.83 12.52 10.36 12:52 12.60 4.83 12.57 10.43 12:53 12.58 4.84 12.54 10.49 12:54 12.61 4.82 12.33 10.50 12:55 12.66 4.80 12.37 10.31 12:56 12.67 4.80 12.33 10.26 12:57 12.63 4.81 12.33 10.38 12:58 12.59 4.85 12.42 10.53 12:59 12.56 4.86 12.51 10.65 13:00 12.59 4.84 12.44 10.58 13:01 12.61 4.83 12.36 10.48 13:02 12.59 4.84 12.49 10.60 13:03 12.53 4.88 12.59 10.79 13:04 12.47 4.91 12.61 10.95 13:05 12.50 4.89 12.72 10.94 13:06 12.53 4.88 12.71 10.82 13:07 12.48 4.91 12.64 10.92 13:08 12.46 4.92 12.45 11.09 13:09 12.43 4.93 12.59 11.13 13:10 12.43 4.93 12.92 11.17 13:11 12.47 4.91 12.42 11.14 13:12 12.52 4.88 12.41 10.94 13:13 12.56 4.87 12.32 10.87 13:14 12.56 4.87 12.21 10.87 13:15 12.50 4.90 12.44 11.01 13:16 12.46 4.92 12.53 11.15 13:17 12.48 4.91 12.50 11.13 13:18 12.54 4.88 12.41 10.93 13:19 12.58 4.86 12.31 10.82 13:20 12.62 4.84 12.05 10.71 13:21 12.63 4.84 12.04 10.67 13:22 12.64 4.83 12.03 10.64 13:23 12.64 4.85 12.13 10.67 13:24 12.60 4.87 12.28 10.73 13:25 12.53 4.90 12.58 10.92 13:26 12.48 4.92 12.45 11.14 13:27 12.46 4.93 12.79 11.20 13:28 12.44 4.94 12.80 11.27 13:29 12.37 4.98 12.91 11.44 13:30 12.30 5.01 13.14 11.68 13:31 12.17 5.08 14.24 11.97 13:32 12.13 5.09 12.79 11.84 13:33 12.34 4.98 12.21 11.25 13:34 12.45 4.93 11.96 10.88 13:35 12.56 4.86 11.89 10.58 13:36 12.66 4.81 12.99 10.21 13:37 12.62 4.85 12.58 10.62 13:38 12.55 4.88 12.31 10.89 13:39 12.56 4.88 12.40 10.92 13:40 12.60 4.85 12.22 10.86 13:41 12.67 4.81 11.97 10.56 13:42 12.68 4.82 12.01 10.49 13:43 12.63 4.85 12.21 10.67 13:44 12.53 4.90 12.37 11.01 13:45 12.45 4.94 12.38 11.33 13:46 12.46 4.93 12.48 11.30 13:47 12.52 4.90 12.34 11.16 University of Utah - Salt Lake City, UT Unit 1 - Solar Taurus 70 CoGen (Turbine and WHRU Duct Burner) AST-2024-0023 1/8/24 38 of 97 Run 2 - RM Data Location: Source: Project No.: Date: Time O₂ - Outlet CO₂ - Outlet CO - Outlet NOx - Outlet Unit % dry % dry ppmvd ppmvd Status Valid Valid Valid Valid Uncorrected Run Average (Cobs)12.51 4.95 12.18 11.10 Cal Gas Concentration (CMA)10.00 10.00 25.00 25.00 Pretest System Zero Response 0.08 0.09 -0.32 0.09 Posttest System Zero Response 0.09 0.13 -0.41 0.08 Average Zero Response (Co)0.09 0.11 -0.37 0.09 Pretest System Cal Response 10.10 9.98 24.97 24.98 Posttest System Cal Response 10.09 10.03 24.71 24.89 Average Cal Response (CM)10.10 10.01 24.84 24.94 Corrected Run Average (Corr)12.41 4.89 12.44 11.09 14:03 12.31 5.02 11.94 11.20 14:04 12.36 5.00 11.83 11.05 14:05 12.33 5.01 11.79 11.11 14:06 12.28 5.04 11.84 11.33 14:07 12.30 5.03 11.72 11.39 14:08 12.43 4.96 11.78 10.99 14:09 12.57 4.89 11.69 10.57 14:10 12.60 4.88 11.62 10.44 14:11 12.57 4.90 11.53 10.60 14:12 12.54 4.91 11.63 10.69 14:13 12.60 4.88 11.48 10.58 14:14 12.66 4.85 11.53 10.37 14:15 12.69 4.84 12.12 10.34 14:16 12.65 4.86 12.85 10.62 14:17 12.61 4.88 12.19 10.89 14:18 12.65 4.86 11.98 10.83 14:19 12.63 4.87 11.96 10.79 14:20 12.55 4.91 12.23 11.00 14:21 12.48 4.95 12.53 11.29 14:22 12.47 4.96 12.56 11.41 14:23 12.47 4.96 12.51 11.38 14:24 12.41 4.99 12.50 11.46 14:25 12.33 5.04 12.84 11.83 14:26 12.28 5.06 12.88 11.98 14:27 12.29 5.05 13.15 11.97 14:28 12.28 5.06 13.04 12.01 14:29 12.22 5.09 13.31 12.07 14:30 12.13 5.13 12.95 12.09 14:31 12.40 4.99 11.99 11.32 14:32 12.65 4.86 12.19 10.51 14:33 12.65 4.87 13.31 10.64 14:34 12.56 4.92 12.41 11.03 14:35 12.55 4.92 12.41 11.21 14:36 12.60 4.89 12.23 10.98 14:37 12.68 4.85 12.13 10.73 14:38 12.71 4.84 11.98 10.61 14:39 12.71 4.83 11.87 10.63 14:40 12.72 4.83 11.77 10.58 14:41 12.69 4.85 11.88 10.58 14:42 12.64 4.88 11.97 10.82 14:43 12.60 4.90 12.28 10.92 14:44 12.64 4.88 11.96 10.93 14:45 12.74 4.83 11.76 10.69 14:46 12.81 4.79 11.54 10.44 14:47 12.78 4.82 11.58 10.44 14:48 12.67 4.89 11.81 10.77 14:49 12.56 4.94 12.06 11.05 14:50 12.53 4.96 12.41 11.24 14:51 12.60 4.92 12.14 11.01 14:52 12.64 4.90 11.97 10.87 14:53 12.61 4.92 12.07 10.89 14:54 12.51 4.97 12.16 11.24 14:55 12.44 5.01 12.42 11.50 14:56 12.41 5.02 12.35 11.50 14:57 12.34 5.07 12.86 11.76 14:58 12.17 5.16 13.64 12.26 14:59 12.07 5.20 12.43 12.32 15:00 12.28 5.09 11.84 11.82 15:01 12.40 5.04 11.71 11.40 15:02 12.41 5.03 11.70 11.30 University of Utah - Salt Lake City, UT Unit 1 - Solar Taurus 70 CoGen (Turbine and WHRU Duct Burner) AST-2024-0023 1/8/24 39 of 97 Run 3 - RM Data Location: Source: Project No.: Date: Time O₂ - Outlet CO₂ - Outlet CO - Outlet NOx - Outlet Unit % dry % dry ppmvd ppmvd Status Valid Valid Valid Valid Uncorrected Run Average (Cobs)12.61 4.96 12.15 11.01 Cal Gas Concentration (CMA)10.00 10.00 25.00 25.00 Pretest System Zero Response 0.09 0.13 -0.41 0.08 Posttest System Zero Response 0.10 0.18 -0.50 0.08 Average Zero Response (Co)0.10 0.16 -0.46 0.08 Pretest System Cal Response 10.09 10.03 24.71 24.89 Posttest System Cal Response 10.09 10.10 24.71 25.04 Average Cal Response (CM)10.09 10.07 24.71 24.97 Corrected Run Average (Corr)12.52 4.84 12.53 10.99 15:14 12.67 4.89 12.01 10.33 15:15 12.65 4.91 12.14 10.44 15:16 12.59 4.94 12.14 10.67 15:17 12.51 4.98 12.22 11.12 15:18 12.49 5.00 12.24 11.21 15:19 12.49 5.00 12.32 11.25 15:20 12.45 5.02 12.42 11.36 15:21 12.42 5.04 12.58 11.53 15:22 12.40 5.05 12.57 11.67 15:23 12.39 5.05 12.72 11.69 15:24 12.39 5.05 12.77 11.71 15:25 12.41 5.04 12.63 11.76 15:26 12.47 5.00 12.28 11.53 15:27 12.54 4.97 12.26 11.26 15:28 12.60 4.94 12.01 11.19 15:29 12.65 4.92 11.93 11.01 15:30 12.71 4.89 11.75 10.85 15:31 12.83 4.83 11.40 10.50 15:32 12.93 4.77 11.20 10.20 15:33 12.95 4.77 11.04 10.01 15:34 12.89 4.81 11.31 10.15 15:35 12.85 4.83 11.20 10.32 15:36 12.85 4.83 11.31 10.34 15:37 12.85 4.83 11.60 10.25 15:38 12.77 4.87 11.66 10.46 15:39 12.69 4.92 12.01 10.74 15:40 12.66 4.93 12.07 10.90 15:41 12.66 4.93 12.06 10.90 15:42 12.70 4.91 11.93 10.78 15:43 12.69 4.92 11.98 10.73 15:44 12.60 4.97 12.29 11.00 15:45 12.55 5.00 12.30 11.18 15:46 12.56 4.99 12.37 11.19 15:47 12.58 4.98 12.13 11.14 15:48 12.55 4.99 12.39 11.21 15:49 12.51 5.01 12.53 11.32 15:50 12.44 5.05 12.45 11.55 15:51 12.42 5.06 12.73 11.64 15:52 12.40 5.07 12.66 11.70 15:53 12.39 5.07 13.00 11.71 15:54 12.49 5.02 12.80 11.48 15:55 12.62 4.96 12.31 11.09 15:56 12.66 4.94 12.14 10.94 15:57 12.63 4.96 12.26 10.90 15:58 12.55 5.00 12.36 11.16 15:59 12.54 5.00 12.51 11.21 16:00 12.62 4.96 12.30 11.00 16:01 12.70 4.92 12.22 10.79 16:02 12.68 4.94 11.96 10.84 16:03 12.67 4.94 12.07 10.89 16:04 12.70 4.92 11.95 10.81 16:05 12.78 4.89 11.69 10.55 16:06 12.78 4.89 11.83 10.50 16:07 12.77 4.90 11.74 10.54 16:08 12.69 4.94 11.94 10.84 16:09 12.65 4.96 12.01 10.92 16:10 12.55 5.01 12.48 11.14 16:11 12.44 5.07 12.62 11.52 16:12 12.42 5.08 12.78 11.71 16:13 12.48 5.05 12.64 11.54 University of Utah - Salt Lake City, UT Unit 1 - Solar Taurus 70 CoGen (Turbine and WHRU Duct Burner) AST-2024-0023 1/8/24 40 of 97 Unit 6 41 of 97 Emissions Calculations Location Source Project No. Run Number Run 1 Run 2 Run 3 Average Date 1/10/24 1/10/24 1/10/24 -- Start Time 12:13 13:26 14:37 -- Stop Time 13:13 14:26 15:37 -- Fuel Factor (O2 dry), dscf/MMBtu Fd 8,710 8,710 8,710 8,710 Heat Input, MMBtu/hr HI 20.1 17.5 20.0 19.2 Volumetric Flow Rate (M19), dscfm Qs 7,256 6,397 7,279 6,977 O₂ Concentration, % dry CO₂12.50 12.60 12.56 12.55 CO₂ Concentration, % dry CCO₂4.88 4.80 4.79 4.83 NOx Concentration, ppmvd CNOx 3.90 3.91 3.55 3.78 NOx Concentration, ppmvd @ 3 % O₂CNOxc3 8.30 8.42 7.63 8.12 NOx Emission Rate, lb/hr ERNOx 0.20 0.18 0.19 0.19 NOx Emission Factor, lb/MMBtu (HI)EFNOx HI 0.010 0.010 0.0093 0.0099 Source Data Input Data - Outlet Calculated Data - Outlet University of Utah - Salt Lake City, UT Unit 6 AST-2024-0023 42 of 97 Method 1 Data Location Source Project No. Date: Vertical Circular 36.00 in 4.00 in 32.00 in 5.59 ft2 2 1 13.0 ft 4.9 (must be ≥ 0.5) 28.0 ft 10.5 (must be ≥ 2) 12 3 Measurer (Initial and Date):AJC 1/10/24 Reviewer (Initial and Date):RJL 1/10/24 23456789101112 1 14.6 16.7 6.7 -- 4.4 -- 3.2 -- 2.6 -- 2.1 1 16.75.349.34 2 85.4 50.0 25.0 -- 14.6 -- 10.5 -- 8.2 -- 6.7 2 50.0 16.00 20.00 3 -- 83.3 75.0 -- 29.6 -- 19.4 -- 14.6 -- 11.8 3 83.3 26.66 30.66 4 -- -- 93.3 -- 70.4 -- 32.3 -- 22.6 -- 17.7 4 -- -- -- 5 -- -- -- -- 85.4 -- 67.7 -- 34.2 -- 25.0 5 -- -- -- 6 -- -- -- -- 95.6 -- 80.6 -- 65.8 -- 35.6 6 -- -- -- 7 -- -- -- -- -- -- 89.5 -- 77.4 -- 64.4 7 -- -- -- 8 -- -- -- -- -- -- 96.8 -- 85.4 -- 75.0 8 -- -- -- 9 -- -- -- -- -- -- -- -- 91.8 -- 82.3 9 -- -- -- 10 -- -- -- -- -- -- -- -- 97.4 -- 88.2 10 -- -- -- 11 -- -- -- -- -- -- -- -- -- -- 93.3 11 -- -- -- 12 -- -- -- -- -- -- -- -- -- -- 97.9 12 -- -- -- *Percent of stack diameter from inside wall to traverse point. A = 13 ft. B = 28 ft. Depth of Duct = 32 in. Cross Sectional Area of Duct: University of Utah - Salt Lake City, UT Unit 6 AST-2024-0023 01/10/24 Stack Parameters Duct Orientation: Duct Design: Distance from Far Wall to Outside of Port: Nipple Length: Depth of Duct: No. of Test Ports: Number of Readings per Point: Distance A: Distance A Duct Diameters: Distance B: Distance B Duct Diameters: Minimum Number of Traverse Points: Actual Number of Traverse Points: CIRCULAR DUCT LOCATION OF TRAVERSE POINTS Traverse Point % of Diameter Distance from inside wall Number of traverse points on a diameter Stack Diagram Cross Sectional Area Distance from outside of port Upstream Disturbance Downstream Disturbance B A 43 of 97 Run 1 - RM Data Location: Source: Project No.: Date: Time O₂ - Outlet CO₂ - Outlet NOx - Outlet Unit % dry % dry ppmvd Status Valid Valid Valid Uncorrected Run Average (Cobs)12.46 4.83 3.93 Cal Gas Concentration (CMA)10.00 10.00 15.00 Pretest System Zero Response 0.00 0.03 0.05 Posttest System Zero Response 0.01 0.03 0.05 Average Zero Response (Co)0.01 0.03 0.05 Pretest System Cal Response 9.98 9.89 15.01 Posttest System Cal Response 9.97 9.85 15.00 Average Cal Response (CM)9.98 9.87 15.01 Corrected Run Average (Corr)12.50 4.88 3.90 12:13 11.82 5.17 4.22 12:14 11.97 5.10 4.21 12:15 12.09 5.05 4.23 12:16 12.11 5.03 4.26 12:17 12.19 4.99 4.22 12:18 12.17 5.00 4.22 12:19 12.32 4.92 4.24 12:20 12.29 4.93 4.23 12:21 12.29 4.94 4.14 12:22 12.28 4.95 4.19 12:23 12.28 4.95 4.21 12:24 12.28 4.94 4.15 12:25 12.31 4.93 4.15 12:26 12.32 4.92 4.18 12:27 12.31 4.92 4.15 12:28 12.30 4.92 4.12 12:29 12.33 4.91 4.07 12:30 12.34 4.90 4.07 12:31 12.42 4.86 3.94 12:32 12.44 4.85 3.95 12:33 12.46 4.83 3.94 12:34 12.48 4.83 3.94 12:35 12.48 4.82 3.94 12:36 12.48 4.82 3.97 12:37 12.51 4.81 3.85 12:38 12.46 4.84 3.90 12:39 12.50 4.81 3.91 12:40 12.51 4.81 3.96 12:41 12.51 4.81 3.97 12:42 12.54 4.79 3.98 12:43 12.57 4.79 3.95 12:44 12.65 4.73 3.83 12:45 12.65 4.73 3.88 12:46 12.66 4.73 3.91 12:47 12.61 4.75 3.83 12:48 12.62 4.75 3.87 12:49 12.60 4.76 3.85 12:50 12.60 4.76 3.79 12:51 12.62 4.74 3.75 12:52 12.61 4.75 3.83 12:53 12.60 4.75 3.79 12:54 12.62 4.74 3.71 12:55 12.62 4.75 3.75 12:56 12.61 4.75 3.73 12:57 12.62 4.74 3.69 12:58 12.63 4.74 3.64 12:59 12.60 4.76 3.71 13:00 12.57 4.77 3.72 13:01 12.58 4.77 3.74 13:02 12.57 4.77 3.81 13:03 12.57 4.78 3.76 13:04 12.56 4.79 3.82 13:05 12.56 4.78 3.79 13:06 12.55 4.79 3.70 13:07 12.57 4.77 3.68 13:08 12.60 4.75 3.67 13:09 12.58 4.77 3.77 13:10 12.62 4.75 3.78 13:11 12.59 4.77 3.90 13:12 12.60 4.75 3.84 University of Utah - Salt Lake City, UT Unit 6 AST-2024-0023 1/10/24 44 of 97 Run 2 - RM Data Location: Source: Project No.: Date: Time O₂ - Outlet CO₂ - Outlet NOx - Outlet Unit % dry % dry ppmvd Status Valid Valid Valid Uncorrected Run Average (Cobs)12.55 4.76 3.94 Cal Gas Concentration (CMA)10.00 10.00 15.00 Pretest System Zero Response 0.01 0.03 0.05 Posttest System Zero Response 0.02 0.03 0.05 Average Zero Response (Co)0.02 0.03 0.05 Pretest System Cal Response 9.97 9.85 15.00 Posttest System Cal Response 9.95 9.93 15.00 Average Cal Response (CM)9.96 9.89 15.00 Corrected Run Average (Corr)12.60 4.80 3.91 13:26 12.47 4.80 3.74 13:27 12.57 4.75 3.69 13:28 12.60 4.73 3.73 13:29 12.63 4.72 3.73 13:30 12.64 4.73 3.70 13:31 12.64 4.72 3.77 13:32 12.68 4.70 3.76 13:33 12.66 4.71 3.81 13:34 12.67 4.70 3.76 13:35 12.70 4.69 3.81 13:36 12.67 4.71 3.81 13:37 12.66 4.71 3.78 13:38 12.66 4.72 3.78 13:39 12.68 4.70 3.78 13:40 12.66 4.71 3.79 13:41 12.67 4.71 3.79 13:42 12.67 4.70 3.77 13:43 12.68 4.69 3.72 13:44 12.68 4.69 3.74 13:45 12.67 4.70 3.76 13:46 12.69 4.70 3.74 13:47 12.72 4.67 3.87 13:48 12.67 4.70 4.08 13:49 12.52 4.78 4.26 13:50 12.43 4.82 3.99 13:51 12.47 4.80 3.90 13:52 12.54 4.76 3.99 13:53 12.46 4.81 4.09 13:54 12.41 4.84 4.12 13:55 12.40 4.84 4.11 13:56 12.39 4.85 4.09 13:57 12.40 4.84 4.14 13:58 12.44 4.82 4.11 13:59 12.42 4.84 4.14 14:00 12.38 4.85 4.15 14:01 12.40 4.83 4.09 14:02 12.45 4.81 4.11 14:03 12.44 4.81 4.11 14:04 12.45 4.81 4.05 14:05 12.47 4.80 4.06 14:06 12.47 4.79 4.05 14:07 12.49 4.79 4.04 14:08 12.49 4.79 4.09 14:09 12.49 4.80 4.07 14:10 12.50 4.78 3.99 14:11 12.50 4.78 4.03 14:12 12.46 4.80 4.00 14:13 12.47 4.79 4.00 14:14 12.48 4.79 4.06 14:15 12.50 4.78 3.99 14:16 12.52 4.76 3.99 14:17 12.52 4.77 4.03 14:18 12.52 4.77 3.98 14:19 12.52 4.76 4.02 14:20 12.54 4.76 3.94 14:21 12.54 4.76 3.94 14:22 12.55 4.75 3.93 14:23 12.56 4.75 3.96 14:24 12.55 4.76 4.02 14:25 12.54 4.76 4.01 University of Utah - Salt Lake City, UT Unit 6 AST-2024-0023 1/10/24 45 of 97 Run 3 - RM Data Location: Source: Project No.: Date: Time O₂ - Outlet CO₂ - Outlet NOx - Outlet Unit % dry % dry ppmvd Status Valid Valid Valid Uncorrected Run Average (Cobs)12.50 4.78 3.59 Cal Gas Concentration (CMA)10.00 10.00 15.00 Pretest System Zero Response 0.02 0.03 0.05 Posttest System Zero Response 0.02 0.02 0.05 Average Zero Response (Co)0.02 0.03 0.05 Pretest System Cal Response 9.95 9.93 15.00 Posttest System Cal Response 9.95 9.97 15.02 Average Cal Response (CM)9.95 9.95 15.01 Corrected Run Average (Corr)12.56 4.79 3.55 14:37 12.35 4.85 3.83 14:38 12.48 4.79 3.73 14:39 12.45 4.81 3.78 14:40 12.48 4.79 3.77 14:41 12.49 4.78 3.81 14:42 12.48 4.79 3.81 14:43 12.46 4.79 3.77 14:44 12.53 4.77 3.65 14:45 12.54 4.76 3.71 14:46 12.57 4.75 3.61 14:47 12.58 4.73 3.50 14:48 12.54 4.76 3.56 14:49 12.48 4.79 3.53 14:50 12.44 4.81 3.58 14:51 12.40 4.83 3.57 14:52 12.42 4.83 3.55 14:53 12.42 4.83 3.52 14:54 12.43 4.82 3.50 14:55 12.43 4.83 3.52 14:56 12.45 4.81 3.52 14:57 12.46 4.81 3.49 14:58 12.61 4.72 3.49 14:59 12.60 4.74 3.47 15:00 12.53 4.77 3.48 15:01 12.49 4.79 3.48 15:02 12.47 4.80 3.50 15:03 12.49 4.79 3.51 15:04 12.45 4.81 3.59 15:05 12.46 4.81 3.57 15:06 12.51 4.78 3.59 15:07 12.48 4.80 3.59 15:08 12.49 4.79 3.55 15:09 12.48 4.80 3.58 15:10 12.53 4.77 3.58 15:11 12.57 4.74 3.57 15:12 12.55 4.75 3.58 15:13 12.55 4.75 3.54 15:14 12.54 4.75 3.59 15:15 12.53 4.77 3.63 15:16 12.50 4.78 3.58 15:17 12.50 4.78 3.60 15:18 12.51 4.78 3.62 15:19 12.50 4.78 3.68 15:20 12.50 4.77 3.61 15:21 12.53 4.76 3.51 15:22 12.51 4.77 3.63 15:23 12.52 4.77 3.60 15:24 12.53 4.77 3.59 15:25 12.53 4.77 3.58 15:26 12.58 4.73 3.53 15:27 12.54 4.76 3.60 15:28 12.46 4.80 3.60 15:29 12.49 4.77 3.56 15:30 12.51 4.77 3.59 15:31 12.53 4.76 3.58 15:32 12.48 4.79 3.56 15:33 12.45 4.80 3.61 15:34 12.44 4.81 3.60 15:35 12.45 4.80 3.61 15:36 12.50 4.78 3.50 University of Utah - Salt Lake City, UT Unit 6 AST-2024-0023 1/10/24 46 of 97 Unit 7 47 of 97 Emissions Calculations Location Source Project No. Run Number Run 1 Run 2 Run 3 Average Date 1/10/24 1/10/24 1/10/24 -- Start Time 8:31 9:44 11:01 -- Stop Time 9:31 10:44 12:01 -- Fuel Factor (O2 dry), dscf/MMBtu Fd 8,710 8,710 8,710 8,710 Heat Input, MMBtu/hr HI 18.9 18.4 20.5 19.3 Volumetric Flow Rate (M19), dscfm Qs 6,176 6,026 6,638 6,280 O₂ Concentration, % dry CO₂11.62 11.64 11.53 11.59 CO₂ Concentration, % dry CCO₂5.34 5.32 5.38 5.35 NOx Concentration, ppmvd CNOx 4.32 4.38 4.15 4.28 NOx Concentration, ppmvd @ 3 % O₂CNOxc3 8.33 8.47 7.93 8.24 NOx Emission Rate, lb/hr ERNOx 0.19 0.19 0.20 0.19 NOx Emission Factor, lb/MMBtu (HI)EFNOx HI 0.010 0.010 0.0096 0.010 Source Data Input Data - Outlet Calculated Data - Outlet University of Utah - Salt Lake City, UT Unit 7 AST-2024-0023 48 of 97 Method 1 Data Location Source Project No. Date: Vertical Circular 36.00 in 4.00 in 32.00 in 5.59 ft2 2 1 13.0 ft 4.9 (must be ≥ 0.5) 27.0 ft 10.1 (must be ≥ 2) 12 3 Measurer (Initial and Date):AJC 1/10/24 Reviewer (Initial and Date):RJL 1/10/24 23456789101112 1 14.6 16.7 6.7 -- 4.4 -- 3.2 -- 2.6 -- 2.1 1 16.75.349.34 2 85.4 50.0 25.0 -- 14.6 -- 10.5 -- 8.2 -- 6.7 2 50.0 16.00 20.00 3 -- 83.3 75.0 -- 29.6 -- 19.4 -- 14.6 -- 11.8 3 83.3 26.66 30.66 4 -- -- 93.3 -- 70.4 -- 32.3 -- 22.6 -- 17.7 4 -- -- -- 5 -- -- -- -- 85.4 -- 67.7 -- 34.2 -- 25.0 5 -- -- -- 6 -- -- -- -- 95.6 -- 80.6 -- 65.8 -- 35.6 6 -- -- -- 7 -- -- -- -- -- -- 89.5 -- 77.4 -- 64.4 7 -- -- -- 8 -- -- -- -- -- -- 96.8 -- 85.4 -- 75.0 8 -- -- -- 9 -- -- -- -- -- -- -- -- 91.8 -- 82.3 9 -- -- -- 10 -- -- -- -- -- -- -- -- 97.4 -- 88.2 10 -- -- -- 11 -- -- -- -- -- -- -- -- -- -- 93.3 11 -- -- -- 12 -- -- -- -- -- -- -- -- -- -- 97.9 12 -- -- -- *Percent of stack diameter from inside wall to traverse point. A = 13 ft. B = 27 ft. Depth of Duct = 32 in. Cross Sectional Area of Duct: University of Utah - Salt Lake City, UT Unit 7 AST-2024-0023 01/10/24 Stack Parameters Duct Orientation: Duct Design: Distance from Far Wall to Outside of Port: Nipple Length: Depth of Duct: No. of Test Ports: Number of Readings per Point: Distance A: Distance A Duct Diameters: Distance B: Distance B Duct Diameters: Minimum Number of Traverse Points: Actual Number of Traverse Points: CIRCULAR DUCT LOCATION OF TRAVERSE POINTS Traverse Point % of Diameter Distance from inside wall Number of traverse points on a diameter Stack Diagram Cross Sectional Area Distance from outside of port Upstream Disturbance Downstream Disturbance B A 49 of 97 Run 1 - RM Data Location: Source: Project No.: Date: Time O₂ - Outlet CO₂ - Outlet NOx - Outlet Unit % dry % dry ppmvd Status Valid Valid Valid Uncorrected Run Average (Cobs)11.62 5.32 4.34 Cal Gas Concentration (CMA)10.00 10.00 15.00 Pretest System Zero Response 0.00 0.04 0.02 Posttest System Zero Response 0.01 0.05 0.04 Average Zero Response (Co)0.01 0.05 0.03 Pretest System Cal Response 9.99 9.92 14.98 Posttest System Cal Response 10.02 9.93 15.02 Average Cal Response (CM)10.01 9.93 15.00 Corrected Run Average (Corr)11.62 5.34 4.32 8:31 11.54 5.35 4.28 8:32 11.62 5.32 4.23 8:33 11.58 5.34 4.26 8:34 11.75 5.24 4.20 8:35 11.64 5.31 4.24 8:36 11.61 5.32 4.27 8:37 11.61 5.32 4.24 8:38 11.64 5.31 4.22 8:39 11.59 5.33 4.28 8:40 11.58 5.34 4.24 8:41 11.59 5.33 4.25 8:42 11.59 5.33 4.26 8:43 11.60 5.33 4.24 8:44 11.57 5.34 4.26 8:45 11.60 5.32 4.29 8:46 11.55 5.35 4.33 8:47 11.55 5.35 4.33 8:48 11.54 5.36 4.29 8:49 11.56 5.34 4.30 8:50 11.59 5.33 4.30 8:51 11.63 5.31 4.33 8:52 11.61 5.32 4.34 8:53 11.58 5.34 4.33 8:54 11.55 5.35 4.35 8:55 11.59 5.33 4.35 8:56 11.56 5.35 4.41 8:57 11.58 5.34 4.44 8:58 11.55 5.35 4.43 8:59 11.59 5.33 4.40 9:00 11.62 5.32 4.39 9:01 11.68 5.29 4.38 9:02 11.63 5.32 4.40 9:03 11.65 5.31 4.40 9:04 11.67 5.30 4.41 9:05 11.67 5.31 4.34 9:06 11.67 5.31 4.40 9:07 11.62 5.33 4.41 9:08 11.65 5.32 4.34 9:09 11.65 5.32 4.32 9:10 11.67 5.30 4.37 9:11 11.67 5.30 4.39 9:12 11.64 5.31 4.41 9:13 11.59 5.35 4.42 9:14 11.64 5.31 4.45 9:15 11.63 5.32 4.43 9:16 11.61 5.32 4.36 9:17 11.62 5.32 4.36 9:18 11.68 5.29 4.31 9:19 11.66 5.30 4.36 9:20 11.66 5.30 4.35 9:21 11.65 5.31 4.37 9:22 11.62 5.32 4.32 9:23 11.66 5.30 4.34 9:24 11.64 5.31 4.33 9:25 11.68 5.29 4.34 9:26 11.69 5.29 4.36 9:27 11.67 5.30 4.50 9:28 11.62 5.33 4.49 9:29 11.63 5.33 4.46 9:30 11.64 5.32 4.48 University of Utah - Salt Lake City, UT Unit 7 AST-2024-0023 1/10/24 50 of 97 Run 2 - RM Data Location: Source: Project No.: Date: Time O₂ - Outlet CO₂ - Outlet NOx - Outlet Unit % dry % dry ppmvd Status Valid Valid Valid Uncorrected Run Average (Cobs)11.66 5.30 4.41 Cal Gas Concentration (CMA)10.00 10.00 15.00 Pretest System Zero Response 0.01 0.05 0.04 Posttest System Zero Response 0.01 0.04 0.05 Average Zero Response (Co)0.01 0.05 0.05 Pretest System Cal Response 10.02 9.93 15.02 Posttest System Cal Response 10.02 9.90 14.98 Average Cal Response (CM)10.02 9.92 15.00 Corrected Run Average (Corr)11.64 5.32 4.38 9:44 11.58 5.33 4.45 9:45 11.59 5.34 4.38 9:46 11.64 5.31 4.44 9:47 11.64 5.31 4.37 9:48 11.68 5.29 4.42 9:49 11.62 5.33 4.49 9:50 11.59 5.33 4.46 9:51 11.65 5.30 4.45 9:52 11.66 5.30 4.45 9:53 11.68 5.29 4.40 9:54 11.68 5.28 4.45 9:55 11.70 5.28 4.38 9:56 11.67 5.29 4.43 9:57 11.67 5.29 4.35 9:58 11.71 5.28 4.40 9:59 11.68 5.29 4.47 10:00 11.66 5.30 4.44 10:01 11.72 5.27 4.40 10:02 11.70 5.28 4.45 10:03 11.69 5.29 4.47 10:04 11.61 5.33 4.52 10:05 11.65 5.31 4.52 10:06 11.66 5.30 4.52 10:07 11.66 5.30 4.47 10:08 11.63 5.32 4.47 10:09 11.64 5.32 4.39 10:10 11.63 5.32 4.38 10:11 11.62 5.33 4.43 10:12 11.65 5.31 4.39 10:13 11.68 5.29 4.41 10:14 11.64 5.30 4.50 10:15 11.66 5.29 4.51 10:16 11.65 5.29 4.49 10:17 11.63 5.31 4.51 10:18 11.64 5.30 4.43 10:19 11.66 5.29 4.38 10:20 11.69 5.27 4.40 10:21 11.69 5.27 4.39 10:22 11.67 5.28 4.39 10:23 11.68 5.28 4.37 10:24 11.65 5.30 4.42 10:25 11.69 5.27 4.34 10:26 11.69 5.28 4.44 10:27 11.67 5.29 4.48 10:28 11.63 5.31 4.52 10:29 11.62 5.31 4.51 10:30 11.62 5.31 4.45 10:31 11.63 5.31 4.46 10:32 11.66 5.29 4.33 10:33 11.66 5.29 4.37 10:34 11.70 5.26 4.37 10:35 11.70 5.27 4.37 10:36 11.68 5.28 4.32 10:37 11.67 5.28 4.30 10:38 11.66 5.29 4.34 10:39 11.65 5.29 4.34 10:40 11.63 5.29 4.31 10:41 11.65 5.29 4.22 10:42 11.67 5.27 4.22 10:43 11.69 5.27 4.29 University of Utah - Salt Lake City, UT Unit 7 AST-2024-0023 1/10/24 51 of 97 Run 3 - RM Data Location: Source: Project No.: Date: Time O₂ - Outlet CO₂ - Outlet NOx - Outlet Unit % dry % dry ppmvd Status Valid Valid Valid Uncorrected Run Average (Cobs)11.53 5.34 4.18 Cal Gas Concentration (CMA)10.00 10.00 15.00 Pretest System Zero Response 0.01 0.04 0.05 Posttest System Zero Response 0.00 0.03 0.05 Average Zero Response (Co)0.01 0.04 0.05 Pretest System Cal Response 10.02 9.90 14.98 Posttest System Cal Response 9.98 9.89 15.01 Average Cal Response (CM)10.00 9.90 15.00 Corrected Run Average (Corr)11.53 5.38 4.15 11:01 11.63 5.29 4.06 11:02 11.61 5.29 4.12 11:03 11.80 5.21 4.02 11:04 11.69 5.26 4.09 11:05 11.71 5.25 4.07 11:06 11.71 5.25 4.06 11:07 11.68 5.27 4.11 11:08 11.68 5.27 4.07 11:09 11.68 5.27 4.12 11:10 11.67 5.28 4.16 11:11 11.67 5.29 4.18 11:12 11.63 5.31 4.20 11:13 11.63 5.31 4.21 11:14 11.66 5.29 4.12 11:15 11.66 5.29 4.09 11:16 11.64 5.30 4.15 11:17 11.64 5.30 4.13 11:18 11.64 5.30 4.16 11:19 11.41 5.40 4.24 11:20 11.40 5.40 4.27 11:21 11.42 5.39 4.21 11:22 11.42 5.39 4.18 11:23 11.42 5.39 4.15 11:24 11.41 5.40 4.24 11:25 11.38 5.41 4.31 11:26 11.37 5.42 4.27 11:27 11.38 5.41 4.27 11:28 11.33 5.44 4.34 11:29 11.31 5.45 4.35 11:30 11.38 5.42 4.30 11:31 11.35 5.43 4.24 11:32 11.32 5.45 4.25 11:33 11.35 5.43 4.24 11:34 11.37 5.42 4.23 11:35 11.35 5.43 4.19 11:36 11.37 5.43 4.24 11:37 11.33 5.44 4.30 11:38 11.33 5.44 4.27 11:39 11.35 5.42 4.25 11:40 11.33 5.44 4.29 11:41 11.33 5.43 4.26 11:42 11.35 5.43 4.22 11:43 11.36 5.43 4.24 11:44 11.36 5.43 4.22 11:45 11.37 5.42 4.15 11:46 11.37 5.42 4.25 11:47 11.36 5.43 4.27 11:48 11.39 5.41 4.24 11:49 11.36 5.43 4.24 11:50 11.32 5.45 4.24 11:51 11.34 5.43 4.31 11:52 11.37 5.41 4.26 11:53 11.37 5.41 4.32 11:54 11.38 5.40 4.30 11:55 11.36 5.42 4.29 11:56 11.38 5.40 4.24 11:57 11.40 5.39 4.25 11:58 11.37 5.41 4.25 11:59 12.68 4.62 3.86 12:00 14.45 3.75 2.86 University of Utah - Salt Lake City, UT Unit 7 AST-2024-0023 1/10/24 52 of 97 Gen 9 Boiler 53 of 97 Emissions Calculations Location Source Project No. Run Number Run 1 Run 2 Run 3 Average Date 1/9/24 1/9/24 1/9/24 -- Start Time 12:50 14:02 15:13 -- Stop Time 13:50 15:02 16:13 -- Fuel Factor (O2 dry), dscf/MMBtu Fd 8,710 8,710 8,710 8,710 Heat Input, MMBtu/hr HI 29.54 26.66 24.96 27.05 Volumetric Flow Rate (M19), dscfm Qs 9,797 8,947 8,472 9,072 O₂ Concentration, % dry CO₂11.75 11.86 11.96 11.86 CO₂ Concentration, % dry CCO₂5.27 5.20 5.15 5.21 NOx Concentration, ppmvd CNOx 4.11 4.20 4.17 4.16 NOx Concentration, ppmvd @ 3 % O₂CNOxc3 8.04 8.31 8.35 8.23 NOx Emission Rate, lb/hr ERNOx 0.29 0.27 0.25 0.27 NOx Emission Factor, lb/MMBtu (HI)EFNOx HI 0.0098 0.010 0.010 0.010 Source Data Input Data - Outlet Calculated Data - Outlet University of Utah - Salt Lake City, UT Gen 9 Boiler AST-2024-0023 54 of 97 Method 1 Data Location Source Project No. Date: Vertical Circular 42.00 in 7.00 in 35.00 in 6.68 ft2 2 1 12.5 ft 4.3 (must be ≥ 0.5) 25.0 ft 8.6 (must be ≥ 2) 12 3 Measurer (Initial and Date):AJC 1/9/24 Reviewer (Initial and Date):RJL 1/9/24 23456789101112 1 14.6 16.7 6.7 -- 4.4 -- 3.2 -- 2.6 -- 2.1 1 16.7 5.85 12.85 2 85.4 50.0 25.0 -- 14.6 -- 10.5 -- 8.2 -- 6.7 2 50.0 17.50 24.50 3 -- 83.3 75.0 -- 29.6 -- 19.4 -- 14.6 -- 11.8 3 83.3 29.16 36.16 4 -- -- 93.3 -- 70.4 -- 32.3 -- 22.6 -- 17.7 4 -- -- -- 5 -- -- -- -- 85.4 -- 67.7 -- 34.2 -- 25.0 5 -- -- -- 6 -- -- -- -- 95.6 -- 80.6 -- 65.8 -- 35.6 6 -- -- -- 7 -- -- -- -- -- -- 89.5 -- 77.4 -- 64.4 7 -- -- -- 8 -- -- -- -- -- -- 96.8 -- 85.4 -- 75.0 8 -- -- -- 9 -- -- -- -- -- -- -- -- 91.8 -- 82.3 9 -- -- -- 10 -- -- -- -- -- -- -- -- 97.4 -- 88.2 10 -- -- -- 11 -- -- -- -- -- -- -- -- -- -- 93.3 11 -- -- -- 12 -- -- -- -- -- -- -- -- -- -- 97.9 12 -- -- -- *Percent of stack diameter from inside wall to traverse point. A = 12.5 ft. B = 25 ft. Depth of Duct = 35 in. Cross Sectional Area of Duct: University of Utah - Salt Lake City, UT Gen 9 Boiler AST-2024-0023 01/09/24 Stack Parameters Duct Orientation: Duct Design: Distance from Far Wall to Outside of Port: Nipple Length: Depth of Duct: No. of Test Ports: Number of Readings per Point: Distance A: Distance A Duct Diameters: Distance B: Distance B Duct Diameters: Minimum Number of Traverse Points: Actual Number of Traverse Points: CIRCULAR DUCT LOCATION OF TRAVERSE POINTS Traverse Point % of Diameter Distance from inside wall Number of traverse points on a diameter Stack Diagram Cross Sectional Area Distance from outside of port Upstream Disturbance Downstream Disturbance B A 55 of 97 Run 1 - RM Data Location: Source: Project No.: Date: Time O₂ - Outlet CO₂ - Outlet NOx - Outlet Unit % dry % dry ppmvd Status Valid Valid Valid Uncorrected Run Average (Cobs)11.73 5.24 4.13 Cal Gas Concentration (CMA)10.00 10.00 15.00 Pretest System Zero Response 0.00 0.04 0.01 Posttest System Zero Response 0.00 0.05 0.00 Average Zero Response (Co)0.00 0.05 0.01 Pretest System Cal Response 9.99 9.90 15.08 Posttest System Cal Response 9.98 9.88 15.04 Average Cal Response (CM)9.99 9.89 15.06 Corrected Run Average (Corr)11.75 5.27 4.11 12:50 11.85 5.19 4.08 12:51 11.95 5.14 3.89 12:52 12.74 4.71 3.48 12:53 11.96 5.13 3.99 12:54 11.95 5.13 4.16 12:55 11.98 5.12 4.19 12:56 12.01 5.10 4.19 12:57 12.04 5.09 4.25 12:58 12.05 5.08 4.28 12:59 12.08 5.07 4.32 13:00 12.11 5.05 4.33 13:01 12.16 5.02 4.36 13:02 12.17 5.02 4.35 13:03 12.20 5.00 4.37 13:04 12.21 5.00 4.41 13:05 12.22 4.99 4.40 13:06 12.24 4.98 4.41 13:07 12.27 4.97 4.40 13:08 12.22 5.00 4.34 13:09 12.12 5.05 4.19 13:10 12.04 5.09 4.17 13:11 11.96 5.13 4.06 13:12 11.90 5.17 4.10 13:13 11.84 5.20 4.05 13:14 11.81 5.21 4.04 13:15 11.75 5.24 4.08 13:16 11.64 5.30 4.10 13:17 11.56 5.33 4.14 13:18 11.57 5.33 4.04 13:19 11.52 5.36 4.03 13:20 11.49 5.37 4.06 13:21 11.49 5.37 3.98 13:22 11.43 5.40 4.07 13:23 11.42 5.40 4.09 13:24 11.43 5.40 4.13 13:25 11.41 5.40 4.12 13:26 11.43 5.39 4.07 13:27 11.44 5.38 4.03 13:28 11.44 5.38 4.05 13:29 11.46 5.37 4.02 13:30 11.47 5.36 4.02 13:31 11.50 5.35 3.97 13:32 11.50 5.35 4.02 13:33 11.50 5.35 4.04 13:34 11.45 5.37 4.09 13:35 11.44 5.38 4.07 13:36 11.46 5.37 4.08 13:37 11.46 5.37 4.17 13:38 11.47 5.37 4.16 13:39 11.47 5.37 4.17 13:40 11.47 5.36 4.20 13:41 11.47 5.36 4.18 13:42 11.44 5.37 4.21 13:43 11.38 5.41 4.21 13:44 11.38 5.40 4.18 13:45 11.42 5.38 4.12 13:46 11.46 5.36 4.08 13:47 11.50 5.34 4.02 13:48 11.58 5.30 3.98 13:49 11.67 5.25 3.90 University of Utah - Salt Lake City, UT Gen 9 Boiler AST-2024-0023 1/9/24 56 of 97 Run 2 - RM Data Location: Source: Project No.: Date: Time O₂ - Outlet CO₂ - Outlet NOx - Outlet Unit % dry % dry ppmvd Status Valid Valid Valid Uncorrected Run Average (Cobs)11.83 5.16 4.21 Cal Gas Concentration (CMA)10.00 10.00 15.00 Pretest System Zero Response 0.00 0.05 0.00 Posttest System Zero Response 0.00 0.04 0.00 Average Zero Response (Co)0.00 0.05 0.00 Pretest System Cal Response 9.98 9.88 15.04 Posttest System Cal Response 9.97 9.87 15.04 Average Cal Response (CM)9.98 9.88 15.04 Corrected Run Average (Corr)11.86 5.20 4.20 14:02 12.19 4.97 4.23 14:03 12.25 4.94 4.25 14:04 12.26 4.94 4.21 14:05 12.19 4.98 4.24 14:06 12.11 5.02 4.23 14:07 12.00 5.08 4.26 14:08 11.93 5.12 4.23 14:09 11.84 5.16 4.22 14:10 11.80 5.18 4.18 14:11 11.75 5.21 4.22 14:12 11.72 5.22 4.18 14:13 11.63 5.26 4.16 14:14 11.62 5.27 4.10 14:15 11.63 5.26 4.10 14:16 11.62 5.28 4.18 14:17 11.57 5.29 4.16 14:18 11.58 5.29 4.17 14:19 11.62 5.27 4.18 14:20 11.61 5.28 4.27 14:21 11.64 5.26 4.22 14:22 11.65 5.25 4.19 14:23 11.66 5.25 4.20 14:24 11.66 5.25 4.19 14:25 11.65 5.25 4.23 14:26 11.62 5.27 4.24 14:27 11.63 5.27 4.25 14:28 11.65 5.25 4.25 14:29 11.65 5.25 4.19 14:30 11.61 5.27 4.18 14:31 11.59 5.28 4.20 14:32 11.60 5.27 4.23 14:33 11.59 5.28 4.27 14:34 11.58 5.28 4.32 14:35 11.61 5.27 4.39 14:36 11.55 5.30 4.37 14:37 11.60 5.27 4.27 14:38 11.64 5.25 4.26 14:39 11.62 5.26 4.34 14:40 11.67 5.24 4.27 14:41 11.64 5.25 4.28 14:42 11.59 5.28 4.37 14:43 11.60 5.27 4.29 14:44 11.69 5.23 4.21 14:45 11.82 5.16 4.08 14:46 11.87 5.14 4.13 14:47 11.95 5.10 4.10 14:48 11.99 5.07 4.10 14:49 12.07 5.03 4.11 14:50 12.12 5.01 4.18 14:51 12.17 4.98 4.13 14:52 12.18 4.98 4.19 14:53 12.19 4.97 4.19 14:54 12.24 4.94 4.24 14:55 12.30 4.91 4.22 14:56 12.31 4.91 4.21 14:57 12.27 4.93 4.19 14:58 12.20 4.97 4.19 14:59 12.14 5.00 4.19 15:00 12.07 5.03 4.13 15:01 12.01 5.07 4.05 University of Utah - Salt Lake City, UT Gen 9 Boiler AST-2024-0023 1/9/24 57 of 97 Run 3 - RM Data Location: Source: Project No.: Date: Time O₂ - Outlet CO₂ - Outlet NOx - Outlet Unit % dry % dry ppmvd Status Valid Valid Valid Uncorrected Run Average (Cobs)11.92 5.10 4.18 Cal Gas Concentration (CMA)10.00 10.00 15.00 Pretest System Zero Response 0.00 0.04 0.00 Posttest System Zero Response 0.01 0.04 0.01 Average Zero Response (Co)0.01 0.04 0.01 Pretest System Cal Response 9.97 9.87 15.04 Posttest System Cal Response 9.96 9.84 15.02 Average Cal Response (CM)9.97 9.86 15.03 Corrected Run Average (Corr)11.96 5.15 4.17 15:13 11.56 5.29 4.23 15:14 11.64 5.25 4.19 15:15 11.60 5.28 4.27 15:16 11.63 5.26 4.23 15:17 11.67 5.25 4.20 15:18 11.62 5.26 4.22 15:19 11.67 5.23 4.19 15:20 11.67 5.23 4.12 15:21 11.81 5.16 4.03 15:22 11.87 5.14 4.15 15:23 11.92 5.10 4.19 15:24 11.99 5.07 4.13 15:25 12.03 5.05 4.11 15:26 12.07 5.04 4.15 15:27 12.11 5.01 4.15 15:28 12.15 4.99 4.18 15:29 12.20 4.97 4.20 15:30 12.22 4.96 4.17 15:31 12.23 4.95 4.18 15:32 12.31 4.91 4.15 15:33 12.33 4.89 4.19 15:34 12.33 4.90 4.15 15:35 12.20 4.96 4.11 15:36 12.20 4.96 4.06 15:37 12.19 4.96 4.11 15:38 12.09 5.02 4.23 15:39 12.04 5.04 4.28 15:40 11.98 5.07 4.27 15:41 11.94 5.09 4.23 15:42 11.87 5.12 4.25 15:43 11.83 5.14 4.20 15:44 11.82 5.15 4.18 15:45 11.76 5.18 4.21 15:46 11.75 5.18 4.24 15:47 11.73 5.19 4.22 15:48 11.74 5.18 4.23 15:49 11.70 5.20 4.31 15:50 11.69 5.21 4.36 15:51 11.74 5.18 4.37 15:52 11.79 5.16 4.26 15:53 11.80 5.15 4.31 15:54 11.82 5.14 4.25 15:55 11.84 5.13 4.26 15:56 11.86 5.11 4.20 15:57 11.85 5.12 4.26 15:58 11.79 5.15 4.25 15:59 11.78 5.16 4.18 16:00 11.74 5.18 4.17 16:01 11.76 5.16 4.14 16:02 11.77 5.16 4.09 16:03 11.79 5.15 4.05 16:04 11.80 5.14 4.09 16:05 11.88 5.10 4.09 16:06 11.94 5.07 4.16 16:07 12.01 5.04 4.19 16:08 12.05 5.01 4.11 16:09 12.14 4.97 4.10 16:10 12.21 4.93 4.06 16:11 12.29 4.89 4.04 16:12 12.31 4.88 4.03 University of Utah - Salt Lake City, UT Gen 9 Boiler AST-2024-0023 1/9/24 58 of 97 Appendix C 59 of 97 QA Data Location Source Project No. O₂ - Outlet CO₂ - Outlet CO - Outlet NOx - Outlet Make SERVOMEX SERVOMEX THERMO THERMO Model 4900 4900 48i 42iQ S/N 100269 100269 208845 123277305521 Operating Range 25 100 100 100 Cylinder ID Zero NA NA NA NA Low NA NA NA NA Mid RR03384 RR03384 CC723464 CC723464 High RR03384 RR03384 CC723464 CC723464 Cylinder Certifed Values Zero NA NA NA NA Low NA NA NA NA Mid 24 23.7 205.1 203 High 24 23.7 205.1 203 Cylinder Expiration Date Zero NA NA NA NA Low NA NA NA NA Mid 10/19/29 10/19/29 5/17/29 5/17/29 High 10/19/29 10/19/29 5/17/29 5/17/29 Type of Sample Line Heated Sample Line Parameter University of Utah - Salt Lake City, UT Unit 1 - Solar Taurus 70 CoGen (Turbine Only) AST-2024-0023 60 of 97 Response Times Location: Source: Project No.: O₂ - Outlet CO₂ - Outlet CO - Outlet NOx - Outlet Zero 35 35 40 43 Low NA NA NA NA Mid 40 40 52 55 High -------- Average 37.5 37.5 46.0 49.0 University of Utah - Salt Lake City, UT Unit 1 - Solar Taurus 70 CoGen (Turbine Only) AST-2024-0023 Parameter Response Times, seconds 61 of 97 Calibration Data Location: Source: Project No.: Date: O₂ - Outlet CO₂ - Outlet CO - Outlet NOx - Outlet Expected Average Concentration 10.00 10.00 20.00 20.00 Span Between Low 10.00 10.00 20.00 20.00 High 50.00 50.00 100.00 100.00 Desired Span 24.00 23.70 50.00 50.00 Low Range Gas Low NA NA NA NA High NA NA NA NA Mid Range Gas Low 9.60 9.48 20.00 20.00 High 14.40 14.22 30.00 30.00 High Range Gas Low NA NA NA NA High NA NA NA NA Actual Concentration (% or ppm) Zero 0.00 0.00 0.00 0.00 Low NA NA NA NA Mid 10.00 10.00 25.00 25.00 High 24.00 23.70 50.00 50.00 Response Time (seconds)45.00 45.00 52.00 57.00 Upscale Calibration Gas (CMA)Mid Mid Mid Mid Instrument Response (% or ppm) Zero 0.00 0.04 -0.02 0.00 Low NA NA NA NA Mid 10.10 10.04 25.01 24.99 High 24.03 23.75 50.02 50.01 Performance (% of Span or Cal. Gas Conc.) Zero 0.00 0.17 0.04 0.00 Low NA NA NA NA Mid 0.42 0.17 0.02 0.02 High 0.13 0.21 0.04 0.02 Status Zero PASS PASS PASS PASS Low NA NA NA NA Mid PASS PASS PASS PASS High PASS PASS PASS PASS Unit 1 - Solar Taurus 70 CoGen (Turbine Only) University of Utah - Salt Lake City, UT Parameter 1/9/24 AST-2024-0023 62 of 97 Bias/Drift Determinations Location: Source: Project No.: O₂ - Outlet CO₂ - Outlet CO - Outlet NOx - Outlet Run 1 Date 1/9/24 Span Value 24.00 23.70 50.00 50.00 Initial Instrument Zero Cal Response 0.00 0.04 -0.02 0.00 Initial Instrument Upscale Cal Response 10.10 10.04 25.01 24.99 Pretest System Zero Response 0.00 0.04 -0.05 0.05 Posttest System Zero Response 0.01 0.04 -0.08 0.06 Pretest System Upscale Response 10.00 9.93 24.98 25.03 Posttest System Upscale Response 10.01 9.93 24.84 25.01 Bias (%) Pretest Zero 0.00 0.00 -0.06 0.10 Posttest Zero 0.04 0.00 -0.12 0.12 Pretest Span -0.42 -0.46 -0.06 0.08 Posttest Span -0.37 -0.46 -0.34 0.04 Drift (%) Zero 0.04 0.00 -0.06 0.02 Mid 0.04 0.00 -0.28 -0.04 Run 2 Date 1/9/24 Span Value 24.00 23.70 50.00 50.00 Instrument Zero Cal Response 0.00 0.04 -0.02 0.00 Instrument Upscale Cal Response 10.10 10.04 25.01 24.99 Pretest System Zero Response 0.01 0.04 -0.08 0.06 Posttest System Zero Response 0.02 0.05 -0.13 0.07 Pretest System Upscale Response 10.01 9.93 24.84 25.01 Posttest System Upscale Response 10.01 9.93 24.85 24.77 Bias (%) Pretest Zero 0.04 0.00 -0.12 0.12 Posttest Zero 0.08 0.04 -0.22 0.14 Pretest Span -0.37 -0.46 -0.34 0.04 Posttest Span -0.37 -0.46 -0.32 -0.44 Drift (%) Zero 0.04 0.04 -0.10 0.02 Mid 0.00 0.00 0.02 -0.48 Run 3 Date 1/9/24 Span Value 24.00 23.70 50.00 50.00 Instrument Zero Cal Response 0.00 0.04 -0.02 0.00 Instrument Upscale Cal Response 10.10 10.04 25.01 24.99 Pretest System Zero Response 0.02 0.05 -0.13 0.07 Posttest System Zero Response 0.03 0.03 -0.17 0.09 Pretest System Upscale Response 10.01 9.93 24.85 24.77 Posttest System Upscale Response 10.00 9.89 24.77 24.78 Bias (%) Pretest Zero 0.08 0.04 -0.22 0.14 Posttest Zero 0.13 -0.04 -0.30 0.18 Pretest Span -0.37 -0.46 -0.32 -0.44 Posttest Span -0.42 -0.63 -0.48 -0.42 Drift (%) Zero 0.04 -0.08 -0.08 0.04 Mid -0.04 -0.17 -0.16 0.02 Parameter University of Utah - Salt Lake City, UT Unit 1 - Solar Taurus 70 CoGen (Turbine Only) AST-2024-0023 63 of 97 QA Data Location Source Project No. O₂ - Outlet CO₂ - Outlet CO - Outlet NOx - Outlet Make SERVOMEX SERVOMEX THERMO THERMO Model 4900 4900 48i 42iQ S/N 100269 100269 208845 123277305521 Operating Range 25 100 100 100 Cylinder ID Zero NA NA NA NA Low NA NA NA NA Mid RR03384 RR03384 CC723464 CC723464 High RR03384 RR03384 CC723464 CC723464 Cylinder Certifed Values Zero NA NA NA NA Low NA NA NA NA Mid 24 23.7 205.1 203 High 24 23.7 205.1 203 Cylinder Expiration Date Zero NA NA NA NA Low NA NA NA NA Mid 10/19/29 10/19/29 5/17/29 5/17/29 High 10/19/29 10/19/29 5/17/29 5/17/29 Type of Sample Line Heated Sample Line Parameter University of Utah - Salt Lake City, UT Unit 1 - Solar Taurus 70 CoGen (Turbine and WHRU Duct Burner) AST-2024-0023 64 of 97 Response Times Location: Source: Project No.: O₂ - Outlet CO₂ - Outlet CO - Outlet NOx - Outlet Zero 45 45 45 45 Low NA NA NA NA Mid 40 40 55 60 High -------- Average 42.5 42.5 50.0 52.5 University of Utah - Salt Lake City, UT Unit 1 - Solar Taurus 70 CoGen (Turbine and WHRU Duct Burner) AST-2024-0023 Parameter Response Times, seconds 65 of 97 Calibration Data Location: Source: Project No.: Date: O₂ - Outlet CO₂ - Outlet CO - Outlet NOx - Outlet Expected Average Concentration 12.00 10.00 20.00 20.00 Span Between Low 12.00 10.00 20.00 20.00 High 60.00 50.00 100.00 100.00 Desired Span 24.00 23.70 50.00 50.00 Low Range Gas Low NA NA NA NA High NA NA NA NA Mid Range Gas Low 9.60 9.48 20.00 20.00 High 14.40 14.22 30.00 30.00 High Range Gas Low NA NA NA NA High NA NA NA NA Actual Concentration (% or ppm) Zero 0.00 0.00 0.00 0.00 Low NA NA NA NA Mid 10.00 10.00 25.00 25.00 High 24.00 23.70 50.00 50.00 Response Time (seconds)43.00 47.00 52.00 55.00 Upscale Calibration Gas (CMA)Mid Mid Mid Mid Instrument Response (% or ppm) Zero 0.00 0.03 -0.02 0.00 Low NA NA NA NA Mid 10.12 10.03 25.02 24.99 High 24.01 23.74 50.05 49.76 Performance (% of Span or Cal. Gas Conc.) Zero 0.00 0.13 0.04 0.00 Low NA NA NA NA Mid 0.50 0.13 0.04 0.02 High 0.04 0.17 0.10 0.48 Status Zero PASS PASS PASS PASS Low NA NA NA NA Mid PASS PASS PASS PASS High PASS PASS PASS PASS Unit 1 - Solar Taurus 70 CoGen (Turbine and WHRU Duct Burner) University of Utah - Salt Lake City, UT Parameter 1/8/24 AST-2024-0023 66 of 97 Bias/Drift Determinations Location: Source: Project No.: O₂ - Outlet CO₂ - Outlet CO - Outlet NOx - Outlet Run 1 Date 1/8/24 Span Value 24.00 23.70 50.00 50.00 Initial Instrument Zero Cal Response 0.00 0.03 -0.02 0.00 Initial Instrument Upscale Cal Response 10.12 10.03 25.02 24.99 Pretest System Zero Response 0.03 0.05 -0.17 0.24 Posttest System Zero Response 0.08 0.09 -0.32 0.09 Pretest System Upscale Response 10.05 9.94 25.52 25.05 Posttest System Upscale Response 10.10 9.98 24.97 24.98 Bias (%) Pretest Zero 0.13 0.08 -0.30 0.48 Posttest Zero 0.33 0.25 -0.60 0.18 Pretest Span -0.29 -0.38 1.00 0.12 Posttest Span -0.08 -0.21 -0.10 -0.02 Drift (%) Zero 0.21 0.17 -0.30 -0.30 Mid 0.21 0.17 -1.10 -0.14 Run 2 Date 1/8/24 Span Value 24.00 23.70 50.00 50.00 Instrument Zero Cal Response 0.00 0.03 -0.02 0.00 Instrument Upscale Cal Response 10.12 10.03 25.02 24.99 Pretest System Zero Response 0.08 0.09 -0.32 0.09 Posttest System Zero Response 0.09 0.13 -0.41 0.08 Pretest System Upscale Response 10.10 9.98 24.97 24.98 Posttest System Upscale Response 10.09 10.03 24.71 24.89 Bias (%) Pretest Zero 0.33 0.25 -0.60 0.18 Posttest Zero 0.38 0.42 -0.78 0.16 Pretest Span -0.08 -0.21 -0.10 -0.02 Posttest Span -0.12 0.00 -0.62 -0.20 Drift (%) Zero 0.04 0.17 -0.18 -0.02 Mid -0.04 0.21 -0.52 -0.18 Run 3 Date 1/8/24 Span Value 24.00 23.70 50.00 50.00 Instrument Zero Cal Response 0.00 0.03 -0.02 0.00 Instrument Upscale Cal Response 10.12 10.03 25.02 24.99 Pretest System Zero Response 0.09 0.13 -0.41 0.08 Posttest System Zero Response 0.10 0.18 -0.50 0.08 Pretest System Upscale Response 10.09 10.03 24.71 24.89 Posttest System Upscale Response 10.09 10.10 24.71 25.04 Bias (%) Pretest Zero 0.38 0.42 -0.78 0.16 Posttest Zero 0.42 0.63 -0.96 0.16 Pretest Span -0.12 0.00 -0.62 -0.20 Posttest Span -0.12 0.30 -0.62 0.10 Drift (%) Zero 0.04 0.21 -0.18 0.00 Mid 0.00 0.30 0.00 0.30 Parameter University of Utah - Salt Lake City, UT Unit 1 - Solar Taurus 70 CoGen (Turbine and WHRU Duct Burner) AST-2024-0023 67 of 97 QA Data Location Source Project No. O₂ - Outlet CO₂ - Outlet NOx - Outlet Make SERVOMEX SERVOMEX THERMO Model 4900 4900 42iQ S/N 100269 100269 123277305521 Operating Range 25 100 100 Cylinder ID Zero NA NA NA Low NA NA NA Mid RR03384 RR03384 CC723464 High RR03384 RR03384 CC723464 Cylinder Certifed Values Zero NA NA NA Low NA NA NA Mid 24 23.7 203 High 24 23.7 203 Cylinder Expiration Date Zero NA NA NA Low NA NA NA Mid 10/19/29 10/19/29 5/17/29 High 10/19/29 10/19/29 5/17/29 Type of Sample Line Heated Sample Line Parameter University of Utah - Salt Lake City, UT Unit 6 AST-2024-0023 68 of 97 Response Times Location: Source: Project No.: O₂ - Outlet CO₂ - Outlet NOx - Outlet Zero 35 35 35 Low NA NA NA Mid 40 40 55 High 45 50 60 Average 40.0 41.7 50.0 University of Utah - Salt Lake City, UT Unit 6 AST-2024-0023 Parameter Response Times, seconds 69 of 97 Calibration Data Location: Source: Project No.: Date: O₂ - Outlet CO₂ - Outlet NOx - Outlet Expected Average Concentration 5.00 5.00 10.00 Span Between Low 5.00 5.00 10.00 High 25.00 25.00 50.00 Desired Span 24.00 23.70 30.00 Low Range Gas Low NA NA NA High NA NA NA Mid Range Gas Low 9.60 9.48 12.00 High 14.40 14.22 18.00 High Range Gas Low NA NA NA High NA NA NA Actual Concentration (% or ppm) Zero 0.00 0.00 0.00 Low NA NA NA Mid 10.00 10.00 15.00 High 24.00 23.70 30.00 Response Time (seconds)40.00 41.67 50.00 Upscale Calibration Gas (CMA)Mid Mid Mid Instrument Response (% or ppm) Zero 0.00 0.04 0.00 Low NA NA NA Mid 10.10 10.04 15.01 High 24.00 23.73 29.98 Performance (% of Span or Cal. Gas Conc.) Zero 0.00 0.17 0.00 Low NA NA NA Mid 0.42 0.17 0.03 High 0.00 0.13 0.07 Status Zero PASS PASS PASS Low NA NA NA Mid PASS PASS PASS High PASS PASS PASS Unit 6 University of Utah - Salt Lake City, UT Parameter 1/10/24 AST-2024-0023 70 of 97 Bias/Drift Determinations Location: Source: Project No.: O₂ - Outlet CO₂ - Outlet NOx - Outlet Run 1 Date 1/10/24 Span Value 24.00 23.70 30.00 Initial Instrument Zero Cal Response 0.00 0.04 0.00 Initial Instrument Upscale Cal Response 10.10 10.04 15.01 Pretest System Zero Response 0.00 0.03 0.05 Posttest System Zero Response 0.01 0.03 0.05 Pretest System Upscale Response 9.98 9.89 15.01 Posttest System Upscale Response 9.97 9.85 15.00 Bias (%) Pretest Zero 0.00 -0.04 0.17 Posttest Zero 0.04 -0.04 0.17 Pretest Span -0.50 -0.63 0.00 Posttest Span -0.54 -0.80 -0.03 Drift (%) Zero 0.04 0.00 0.00 Mid -0.04 -0.17 -0.03 Run 2 Date 1/10/24 Span Value 24.00 23.70 30.00 Instrument Zero Cal Response 0.00 0.04 0.00 Instrument Upscale Cal Response 10.10 10.04 15.01 Pretest System Zero Response 0.01 0.03 0.05 Posttest System Zero Response 0.02 0.03 0.05 Pretest System Upscale Response 9.97 9.85 15.00 Posttest System Upscale Response 9.95 9.93 15.00 Bias (%) Pretest Zero 0.04 -0.04 0.17 Posttest Zero 0.08 -0.04 0.17 Pretest Span -0.54 -0.80 -0.03 Posttest Span -0.63 -0.46 -0.03 Drift (%) Zero 0.04 0.00 0.00 Mid -0.08 0.34 0.00 Run 3 Date 1/10/24 Span Value 24.00 23.70 30.00 Instrument Zero Cal Response 0.00 0.04 0.00 Instrument Upscale Cal Response 10.10 10.04 15.01 Pretest System Zero Response 0.02 0.03 0.05 Posttest System Zero Response 0.02 0.02 0.05 Pretest System Upscale Response 9.95 9.93 15.00 Posttest System Upscale Response 9.95 9.97 15.02 Bias (%) Pretest Zero 0.08 -0.04 0.17 Posttest Zero 0.08 -0.08 0.17 Pretest Span -0.63 -0.46 -0.03 Posttest Span -0.63 -0.30 0.03 Drift (%) Zero 0.00 -0.04 0.00 Mid 0.00 0.17 0.07 Parameter University of Utah - Salt Lake City, UT Unit 6 AST-2024-0023 71 of 97 QA Data Location Source Project No. O₂ - Outlet CO₂ - Outlet NOx - Outlet Make SERVOMEX SERVOMEX THERMO Model 4900 4900 42iQ S/N 100269 100269 123277305521 Operating Range 25 100 100 Cylinder ID Zero NA NA NA Low NA NA NA Mid RR03384 RR03384 CC723464 High RR03384 RR03384 CC723464 Cylinder Certifed Values Zero NA NA NA Low NA NA NA Mid 24 23.7 203 High 24 23.7 203 Cylinder Expiration Date Zero NA NA NA Low NA NA NA Mid 10/19/29 10/19/29 5/17/29 High 10/19/29 10/19/29 5/17/29 Type of Sample Line Heated Sample Line Parameter University of Utah - Salt Lake City, UT Unit 7 AST-2024-0023 72 of 97 Response Times Location: Source: Project No.: O₂ - Outlet CO₂ - Outlet NOx - Outlet Zero 35 35 35 Low NA NA NA Mid 40 40 55 High ------ Average 37.5 37.5 45.0 University of Utah - Salt Lake City, UT Unit 7 AST-2024-0023 Parameter Response Times, seconds 73 of 97 Calibration Data Location: Source: Project No.: Date: O₂ - Outlet CO₂ - Outlet NOx - Outlet Expected Average Concentration 5.00 5.00 10.00 Span Between Low 5.00 5.00 10.00 High 25.00 25.00 50.00 Desired Span 24.00 23.70 30.00 Low Range Gas Low NA NA NA High NA NA NA Mid Range Gas Low 9.60 9.48 12.00 High 14.40 14.22 18.00 High Range Gas Low NA NA NA High NA NA NA Actual Concentration (% or ppm) Zero 0.00 0.00 0.00 Low NA NA NA Mid 10.00 10.00 15.00 High 24.00 23.70 30.00 Response Time (seconds)40.00 41.00 61.00 Upscale Calibration Gas (CMA)Mid Mid Mid Instrument Response (% or ppm) Zero 0.00 0.04 0.00 Low NA NA NA Mid 10.10 10.04 15.01 High 24.00 23.73 29.98 Performance (% of Span or Cal. Gas Conc.) Zero 0.00 0.17 0.00 Low NA NA NA Mid 0.42 0.17 0.03 High 0.00 0.13 0.07 Status Zero PASS PASS PASS Low NA NA NA Mid PASS PASS PASS High PASS PASS PASS Unit 7 University of Utah - Salt Lake City, UT Parameter 1/10/24 AST-2024-0023 74 of 97 Bias/Drift Determinations Location: Source: Project No.: O₂ - Outlet CO₂ - Outlet NOx - Outlet Run 1 Date 1/10/24 Span Value 24.00 23.70 30.00 Initial Instrument Zero Cal Response 0.00 0.04 0.00 Initial Instrument Upscale Cal Response 10.10 10.04 15.01 Pretest System Zero Response 0.00 0.04 0.02 Posttest System Zero Response 0.01 0.05 0.04 Pretest System Upscale Response 9.99 9.92 14.98 Posttest System Upscale Response 10.02 9.93 15.02 Bias (%) Pretest Zero 0.00 0.00 0.07 Posttest Zero 0.04 0.04 0.13 Pretest Span -0.46 -0.51 -0.10 Posttest Span -0.33 -0.46 0.03 Drift (%) Zero 0.04 0.04 0.07 Mid 0.12 0.04 0.13 Run 2 Date 1/10/24 Span Value 24.00 23.70 30.00 Instrument Zero Cal Response 0.00 0.04 0.00 Instrument Upscale Cal Response 10.10 10.04 15.01 Pretest System Zero Response 0.01 0.05 0.04 Posttest System Zero Response 0.01 0.04 0.05 Pretest System Upscale Response 10.02 9.93 15.02 Posttest System Upscale Response 10.02 9.90 14.98 Bias (%) Pretest Zero 0.04 0.04 0.13 Posttest Zero 0.04 0.00 0.17 Pretest Span -0.33 -0.46 0.03 Posttest Span -0.33 -0.59 -0.10 Drift (%) Zero 0.00 -0.04 0.03 Mid 0.00 -0.13 -0.13 Run 3 Date 1/10/24 Span Value 24.00 23.70 30.00 Instrument Zero Cal Response 0.00 0.04 0.00 Instrument Upscale Cal Response 10.10 10.04 15.01 Pretest System Zero Response 0.01 0.04 0.05 Posttest System Zero Response 0.00 0.03 0.05 Pretest System Upscale Response 10.02 9.90 14.98 Posttest System Upscale Response 9.98 9.89 15.01 Bias (%) Pretest Zero 0.04 0.00 0.17 Posttest Zero 0.00 -0.04 0.17 Pretest Span -0.33 -0.59 -0.10 Posttest Span -0.50 -0.63 0.00 Drift (%) Zero -0.04 -0.04 0.00 Mid -0.17 -0.04 0.10 Parameter University of Utah - Salt Lake City, UT Unit 7 AST-2024-0023 75 of 97 QA Data Location Source Project No. O₂ - Outlet CO₂ - Outlet NOx - Outlet Make SERVOMEX SERVOMEX THERMO Model 4900 4900 42iQ S/N 100269 100269 123277305521 Operating Range 25 100 100 Cylinder ID Zero NA NA NA Low NA NA NA Mid RR03384 RR03384 CC723464 High RR03384 RR03384 CC723464 Cylinder Certifed Values Zero NA NA NA Low NA NA NA Mid 24 23.7 203 High 24 23.7 203 Cylinder Expiration Date Zero NA NA NA Low NA NA NA Mid 10/19/29 10/19/29 5/17/29 High 10/19/29 10/19/29 5/17/29 Type of Sample Line Heated Sample Line Parameter University of Utah - Salt Lake City, UT Gen 9 Boiler AST-2024-0023 76 of 97 Response Times Location: Source: Project No.: O₂ - Outlet CO₂ - Outlet NOx - Outlet Zero 40 40 50 Low NA NA NA Mid 45 44 62 High ------ Average 42.5 42.0 56.0 University of Utah - Salt Lake City, UT Gen 9 Boiler AST-2024-0023 Parameter Response Times, seconds 77 of 97 Calibration Data Location: Source: Project No.: Date: O₂ - Outlet CO₂ - Outlet NOx - Outlet Expected Average Concentration 6.00 6.00 10.00 Span Between Low 6.00 6.00 10.00 High 30.00 30.00 50.00 Desired Span 24.00 23.70 30.00 Low Range Gas Low NA NA NA High NA NA NA Mid Range Gas Low 9.60 9.48 12.00 High 14.40 14.22 18.00 High Range Gas Low NA NA NA High NA NA NA Actual Concentration (% or ppm) Zero 0.00 0.00 0.00 Low NA NA NA Mid 10.00 10.00 15.00 High 24.00 23.70 30.00 Response Time (seconds)42.50 42.00 56.00 Upscale Calibration Gas (CMA)Mid Mid Mid Instrument Response (% or ppm) Zero 0.00 0.03 0.01 Low NA NA NA Mid 10.10 10.05 15.03 High 24.02 23.75 30.20 Performance (% of Span or Cal. Gas Conc.) Zero 0.00 0.13 0.03 Low NA NA NA Mid 0.42 0.21 0.10 High 0.08 0.21 0.67 Status Zero PASS PASS PASS Low NA NA NA Mid PASS PASS PASS High PASS PASS PASS Gen 9 Boiler University of Utah - Salt Lake City, UT Parameter 1/9/24 AST-2024-0023 78 of 97 Bias/Drift Determinations Location: Source: Project No.: O₂ - Outlet CO₂ - Outlet NOx - Outlet Run 1 Date 1/9/24 Span Value 24.00 23.70 30.00 Initial Instrument Zero Cal Response 0.00 0.03 0.01 Initial Instrument Upscale Cal Response 10.10 10.05 15.03 Pretest System Zero Response 0.00 0.04 0.01 Posttest System Zero Response 0.00 0.05 0.00 Pretest System Upscale Response 9.99 9.90 15.08 Posttest System Upscale Response 9.98 9.88 15.04 Bias (%) Pretest Zero 0.00 0.04 0.00 Posttest Zero 0.00 0.08 -0.03 Pretest Span -0.46 -0.63 0.17 Posttest Span -0.50 -0.72 0.03 Drift (%) Zero 0.00 0.04 -0.03 Mid -0.04 -0.08 -0.13 Run 2 Date 1/9/24 Span Value 24.00 23.70 30.00 Instrument Zero Cal Response 0.00 0.03 0.01 Instrument Upscale Cal Response 10.10 10.05 15.03 Pretest System Zero Response 0.00 0.05 0.00 Posttest System Zero Response 0.00 0.04 0.00 Pretest System Upscale Response 9.98 9.88 15.04 Posttest System Upscale Response 9.97 9.87 15.04 Bias (%) Pretest Zero 0.00 0.08 -0.03 Posttest Zero 0.00 0.04 -0.03 Pretest Span -0.50 -0.72 0.03 Posttest Span -0.54 -0.76 0.03 Drift (%) Zero 0.00 -0.04 0.00 Mid -0.04 -0.04 0.00 Run 3 Date 1/9/24 Span Value 24.00 23.70 30.00 Instrument Zero Cal Response 0.00 0.03 0.01 Instrument Upscale Cal Response 10.10 10.05 15.03 Pretest System Zero Response 0.00 0.04 0.00 Posttest System Zero Response 0.01 0.04 0.01 Pretest System Upscale Response 9.97 9.87 15.04 Posttest System Upscale Response 9.96 9.84 15.02 Bias (%) Pretest Zero 0.00 0.04 -0.03 Posttest Zero 0.04 0.04 0.00 Pretest Span -0.54 -0.76 0.03 Posttest Span -0.58 -0.89 -0.03 Drift (%) Zero 0.04 0.00 0.03 Mid -0.04 -0.13 -0.07 Parameter University of Utah - Salt Lake City, UT Gen 9 Boiler AST-2024-0023 79 of 97 Balance Red Ball Technical Gas Service 555 Craig Kennedy Way Shreveport, LA 71107 800-551-8150 Accreditation #62754 PGVP Vendor ID # G12021 EPA PROTOCOL GAS CERTIFICATE OF ANALYSIS Cylinder Number:RR03384 Certification Date:10/21/2021 Product ID Number:127907 Expiration Date:10/19/2029 Cylinder Pressure:1900 PSIG MFG Facility: - Shreveport - LA COA #RR03384.20211012-0 Lot Number:RR03384.20211012 Customer PO. NO.:Tracking Number:103923781 Customer:Previous Certification Dates: This calibration standard has been certified per the May 2012 EPA Traceability Protocol, Document EPA-600/R-12/531, using procedure G2. Do Not Use This Cylinder Below 100 psig (0.7 Megapascal). Certified Concentration(s) Component Concentration Uncertainty Analytical Principle Assayed On Carbon Dioxide 23.7 %±0.18 %NDIR 10/21/2021 Oxygen 24.0 %±0.13 %MPA 10/20/2021 Nitrogen Analytical Measurement Data Available Online. Reference Standard(s) Serial Number Lot Expiration Type Balance Component Concentration Uncertainty(%)NIST Reference CC727782 CC727782.20201022 04/06/2029 GMIS N2 O2 20.03 %0.115 SRM 2659a EB0039149 EB0039149.20190610 11/24/2027 GMIS N2 CO2 24.75 %0.274 C1579010.02 EB0078072 EB0078072.20180504 07/21/2026 GMIS N2 O2 24 %0.497 071001 EB0100923 EB0100923.20201022 05/19/2029 GMIS N2 CO2 19.47 %0.171 C1847810.03 Analytical Instrumentation SMART-CERT Component Principle Make MPC Date O2 MPA Thermo 10/01/2021 CO2 NDIR Thermo 10/19/2021 Serial 1162980025 1162980025 This is to certify the gases referenced have been calibrated/tested, and verified to meet the defined specifications. This calibration/test was performed using Gases or Scales that are traceable through National Institute of Standards and Technology (NIST) to the International System of Units (SI). The basis of compliance stated is a comparison of the measurement parameters to the specified or required calibration/testing process. The expanded uncertainties use a coverage factor of k=2 to approximate the 95% confidence level of the measurement, unless otherwise noted. This calibration certificate applies only to the item described and shall not be reproduced other than in full, without written approval from Red Ball Technical Gas Services. If not included, the uncertainty of calibrations are available upon request and were taken into account when determining pass or fail. Brittany Johnson Analytical Chemist Assay Laboratory: Red Ball TGS Version 02-J, Revised on 2018-09-17 Model 410i 410i 80 of 97 Balance Red Ball Technical Gas Service 555 Craig Kennedy Way Shreveport, LA 71107 800-551-8150 Accreditation #62754 PGVP Vendor ID # G12021 EPA PROTOCOL GAS CERTIFICATE OF ANALYSIS Cylinder Number:CC723464 Certification Date:05/19/2021 Product ID Number:125724 Expiration Date:05/17/2029 Cylinder Pressure:1750 PSIG MFG Facility: - Shreveport - LA COA #CC723464.20210430-0 Lot Number:CC723464.20210430 Customer PO. NO.:Tracking Number:098502019 Customer:Previous Certification Dates: This calibration standard has been certified per the May 2012 EPA Traceability Protocol, Document EPA-600/R-12/531, using procedure G1. Do Not Use This Cylinder Below 100 psig (0.7 Megapascal). Certified Concentration(s) Component Concentration Uncertainty Analytical Principle Assayed On Carbon Monoxide 205.1 PPM ±0.8 PPM FTIR 05/05/2021 Nitric Oxide 203 PPM ±1.5 PPM Chemiluminescence 05/12/2021, 05/19/2021 Sulfur Dioxide 199 PPM ±1.4 PPM NDIR 05/05/2021, 05/18/2021 Total Oxides of Nitrogen 204 PPM Nitrogen Analytical Measurement Data Available Online. Reference Standard(s) Serial Number Lot Expiration Type Balance Component Concentration Uncertainty(%)NIST Reference AAL046966 AAL046966.20191115 04/22/2028 GMIS N2 NO 964 PPM 0.489 SRM 2630 CC712935 CC712935.20201221 04/27/2029 GMIS N2 NO 284 PPM 0.518 SRM 1687b EB0003515 EB0003515.20191025 04/28/2028 GMIS N2 CO 346 PPM 0.345 SRM 1680b EB0038537 EB0038537.20170428 09/06/2025 GMIS N2 SO2 299 PPM 0.502 1662a EB0078147 EB0078147.20191115 04/21/2028 GMIS N2 NO 595 PPM 0.503 SRM 2630 EB0078766 EB0078766.20190205 04/28/2028 GMIS N2 CO 200.4 PPM 0.421 SRM 1680b EB0081035 EB0081035.20170428 09/06/2025 GMIS N2 SO2 925 PPM 0.428 1662a Analytical Instrumentation SMART-CERT Component Principle Make MPC Date CO FTIR MKS 04/21/2021 SO2 NDIR Horiba 04/23/2021 NO Chemiluminescence Thermo 04/23/2021 NO Chemiluminescence Thermo 04/26/20211192604297 SO2 FTIR MKS 05/10/2021017146467 Serial 017146467 G000G2A 1192604297 This is to certify the gases referenced have been calibrated/tested, and verified to meet the defined specifications. This calibration/test was performed using Gases or Scales that are traceable through National Institute of Standards and Technology (NIST) to the International System of Units (SI). The basis of compliance stated is a comparison of the measurement parameters to the specified or required calibration/testing process. The expanded uncertainties use a coverage factor of k=2 to approximate the 95% confidence level of the measurement, unless otherwise noted. This calibration certificate applies only to the item described and shall not be reproduced other than in full, without written approval from Red Ball Technical Gas Services. If not included, the uncertainty of calibrations are available upon request and were taken into account when determining pass or fail. Jasmine Godfrey Analytical Chemist Assay Laboratory: Red Ball TGS Version 02-J, Revised on 2018-09-17 Model MKS 2031DJG2EKVS13T VIA-510 SO2 42iQ-HL MKS 2031DJG2EKVS13T 42iQ-HL 81 of 97 Location: Project No.: Analyzer Make THERMO Pre-Test Date 1/8/24 Time 12:28 Analyzer Model 42iQ Pre-Test Concentration, ppm 43.08 Serial Number 1.233E+11 Pre-Test Efficiency, %90 Cylinder ID Number CC509482 Post-Test Date --Time -- Cylinder Exp. Date 3/20/26 Post-Test Concentration, ppm -- Cylinder Concentration, ppm 47.8 Post-Test Efficiency, %- *Required Efficiency is ≥ 90 %. University of Utah - Salt Lake City, UT 2024-0023 NO2 Converter Check - Outlet 82 of 97 CERTIFICATE OF ANALYSIS Grade of Product: EPA PROTOCOL STANDARD Part Number: E03NI94E15W0005 Reference Number: 153-402667045-1 Cylinder Number: CC509482 Cylinder Volume: 145.0 CF Laboratory: 124 - Tooele (SAP) - UT Cylinder Pressure: 2015 PSIG PGVP Number: B72023 Valve Outlet: 660 Gas Code:NO2,O2,BALN Certification Date: Mar 20, 2023 Expiration Date:Mar 20, 2026 Certification performed in accordance with “EPA Traceability Protocol for Assay and Certification of Gaseous Calibration Standards (May 2012)” document EPA 600/R-12/531, using the assay procedures listed. Analytical Methodology does not require correction for analytical interference. This cylinder has a total analytical uncertainty as stated below with a confidence level of 95%. There are no significant impurities which affect the use of this calibration mixture. All concentrations are on a mole/mole basis unless otherwise noted. The results relate only to the items tested. The report shall not be reproduced except in full without approval of the laboratory. Do Not Use This Cylinder below 100 psig, i.e. 0.7 megapascals. ANALYTICAL RESULTS Component Requested Actual Protocol Total Relative Assay Concentration Concentration Method Uncertainty Dates NITROGEN DIOXIDE 50.00 PPM 47.80 PPM G1 +/- 2.0% NIST Traceable 03/13/2023, 03/20/2023 OXYGEN 5.000 %5.004 %G1 +/- 0.7% NIST Traceable 03/13/2023 NITROGEN Balance CALIBRATION STANDARDS Type Lot ID Cylinder No Concentration Uncertainty Expiration Date GMIS 12397 CC511358 59.32 PPM NITROGEN DIOXIDE/NITROGEN +/- 1.4%Dec 17, 2024 NTRM 14060629 CC436987 4.794 % OXYGEN/NITROGEN 0.4%Oct 29, 2025 ANALYTICAL EQUIPMENT Instrument/Make/Model Analytical Principle Last Multipoint Calibration MKS FTIR NO2 018143349 FTIR Mar 09, 2023 Horiba MPA-510 W603MM58 O2 O2 Paramagnetic (Mason)Mar 09, 2023 Triad Data Available Upon Request Airgas Specialty Gases Airgas USA LLC 525 North Industrial Loop Road Tooele, UT 84074 Airgas.com Signature on file Approved for Release Page 1 of 1 83 of 97 Location: Source: Project No.: Date EPA O2 SERVOMEX 4900 100269 25.0 Cylinder Number ID Zero NA Mid RR03686 High RR03384 Cylinder Certified Values Zero 0.0 Mid 10.98 High 24 Instrument Response (% or ppm) Zero 0.0 Mid 11.0 High 23.9 Calibration Gas Selection (% of Span) Mid 43.9 High 96.0 Calibration Error Performance (% of Span) Zero 0.0 Mid 0.0 High -0.2 Linearity (% of Range) 0.1 (%) lpm (%)(%)(%)(%)(%)(%)(%)( ± 2 %) 10L/5L 80.0 5.0 19.2 19.2 19.3 19.3 19.1 19.23 0.03 0.1% 10L/5L 50.0 5.0 12.0 12.0 12.1 12.1 12.1 12.10 0.10 0.9% 10L/1L 20.0 4.0 4.8 4.8 4.9 4.8 4.8 4.84 0.04 0.9% 10L/1L 10.0 4.0 2.4 2.4 2.5 2.4 2.5 2.45 0.05 1.9% (%)( ± 2 %)( ± 2 %)( ± 2 %) 19.23 0.2%0.3% -0.5% 12.10 0.1%0.3% -0.4% 4.84 1.0% -0.9% -0.1% 2.45 0.5% -0.7% 0.1% Mid-Level Supply Gas Calibration Direct to Analyzer Calibration Injection 1 Injection 2 Injection 3 Average Gas Analyzer Analyzer Analyzer Analyzer Concentration Concentration Concentration Concentration Concentration (%) (%) (%) (%) (%) (%)( ± 2 %) 10.98 11.0 11.0 11.0 10.99 0.01 0.1% Analyzer Make: SERVOMEX University of Utah - Salt Lake City, UT Unit 1 - Solar Taurus 70 CoGen (Turbine and WHRU Duct Burner) 2024-0023 1/1/83 Parameter Make Model S/N Span Method Criteria Analyzer Model: 4900 Analyzer SN: 100269 Environics ID: 8027 Component/Balance Gas: O2/N2 Cylinder Gas ID (Dilution): RR03384 Cylinder Gas Concentration (Dilution), %: 24 *Not all AST Environics Units have 2-10L Mass Flow Controllers. For these units the 90% @ 7lpm and 80% @ 7lpm injections will not be conducted. Cylinder Gas ID (Mid-Level): RR03686 Cylinder Gas Concentration (Mid-Level), %: 10.98 Target Mass Flow Contollers Target Dilution Target Flow Rate Target Concentration Actual Concentration Injection 1 Analyzer Concentration Injection 2 Analyzer Concentration Injection 3 Analyzer Concentration Average Analyzer Concentration Difference Average Error Average Analyzer Concentration Injection 1 Error Injection 2 Error Injection 3 Error Difference Average Error 84 of 97 Issuing Department Dilution System Make: Dilution System Model: Dilution System S/N: Calibration Equipment Make: Calibration Equipment Model: Calibration Equipment S/N: Flow Cell S/N: Flow Cell S/N: Calibration Gas: Barometric Pressure, mmHg: Ambient Temperature, °F: Mass Flow Controller ID Size, ccm: Make: Model: S/N: Set Flow True Flow Difference Set Flow True Flow Difference Set Flow True Flow Difference cc/min cc/min cc/min cc/min cc/min cc/min 5%500 508 1.6%500 504 0.8%50 50 0.6% 10%1,000 1,024 2.4%1,000 1,020 2.0%100 101 0.7% 20%2,000 2,057 2.8%2,000 2,048 2.4%200 203 1.6% 30%3,000 3,079 2.6%3,000 3,073 2.4%300 305 1.8% 40%4,000 4,104 2.6%4,000 4,094 2.4%400 407 1.6% 50%5,000 5,113 2.3%5,000 5,107 2.1%500 507 1.4% 60%6,000 6,129 2.1%6,000 6,120 2.0%600 609 1.5% 70%7,000 7,136 1.9%7,000 7,134 1.9%700 711 1.6% 80%8,000 8,145 1.8%8,000 8,152 1.9%800 813 1.7% 90%9,000 9,162 1.8%9,000 9,171 1.9%900 917 1.9% 100%10,000 10,193 1.9%10,000 10,189 1.9%1,000 1,022 2.2% Date: Document ID Revision Effective Date Page 620.009 22.0 12/16/22 1 of 1 Mass Flow Controller Calibration Tech Services 8027 Alicat Scientific M-10SLPD/5MM-D/5M, M-1SLPM-D/5M 127208/127206 127208 127206 Nitrogen Calibration Performed By:RJL 3/31/2023 0455242007 Note: The mass flow controller's calibration values are used by the dilution system's operating software to improve accuracy. These calibrations are not necessarily indicative of the systems overall performance. Performance is verified by conducting a Method 205 prior to each field use. 0455242008 0455238004 Environics EFC 202 10,000 # 2 # 3 Environics 1,000 Environics EFC 202 EFC 202 #1 10,000 Environics 25.76 66 4040 85 of 97 Balance Red Ball Technical Gas Service 555 Craig Kennedy Way Shreveport, LA 71107 800-551-8150 Accreditation #62754 PGVP Vendor ID # G12023 EPA PROTOCOL GAS CERTIFICATE OF ANALYSIS Cylinder Number:RR03686 Certification Date:09/21/2023 Product ID Number:125371 Expiration Date:09/19/2031 Cylinder Pressure:1900 PSIG MFG Facility: - Shreveport - LA COA #RR03686.20230831-0 Lot Number:RR03686.20230831 Customer PO. NO.:Tracking Number:107553544 Customer:Previous Certification Dates: This calibration standard has been certified per the May 2012 EPA Traceability Protocol, Document EPA-600/R-12/531, using procedure G1. Do Not Use This Cylinder Below 100 psig (0.7 Megapascal). Certified Concentration(s) Component Concentration Uncertainty Analytical Principle Assayed On Carbon Dioxide 10.9 %±0.11 %FTIR 09/21/2023 Oxygen 10.98 %±0.03 %MPA 09/18/2023 Nitrogen Analytical Measurement Data Available Online. Reference Standard(s) Serial Number Lot Expiration Type Balance Component Concentration Uncertainty(%)NIST Reference CC737012 CC737012.20230228 07/09/2031 GMIS N2 O2 20 %0.112 SRM 2659a EB0022021 EB0022021.20180323 07/15/2026 GMIS N2 CO2 14.9 %0.777 101001 Analytical Instrumentation SMART-CERT Component Principle Make MPC Date O2 MPA Thermo 09/18/2023 CO2 FTIR MKS 09/21/2023 Serial 1162980025 017146467 This is to certify the gases referenced have been calibrated/tested, and verified to meet the defined specifications. This calibration/test was performed using Gases or Scales that are traceable through National Institute of Standards and Technology (NIST) to the International System of Units (SI). The basis of compliance stated is a comparison of the measurement parameters to the specified or required calibration/testing process. The expanded uncertainties use a coverage factor of k=2 to approximate the 95% confidence level of the measurement, unless otherwise noted. This calibration certificate applies only to the item described and shall not be reproduced other than in full, without written approval from Red Ball Technical Gas Services. If not included, the uncertainty of calibrations are available upon request and were taken into account when determining pass or fail. Jasmine Godfrey Analytical Chemist Assay Laboratory: Red Ball TGS Version 02-J, Revised on 2018-09-17 Model 410i MKS 2031DJG2EKVS13T 86 of 97 Location: Source: Project No.: Date: Time O2 CO2 CO NOx (%) (%) (ppm) (ppm) A-1 12:48 12.55 4.87 12.70 10.43 2 12:50 12.60 4.83 12.59 10.40 3 12:52 12.60 4.83 12.57 10.43 4 12:54 12.61 4.82 12.33 10.50 5 12:56 12.67 4.80 12.33 10.26 6 12:58 12.59 4.85 12.42 10.53 B-1 13:00 12.59 4.84 12.44 10.58 2 13:02 12.59 4.84 12.49 10.60 3 13:04 12.47 4.91 12.61 10.95 4 13:06 12.53 4.88 12.71 10.82 5 13:08 12.46 4.92 12.45 11.09 6 13:10 12.43 4.93 12.92 .11.17 12.6 4.9 12.5 10.6 Single Point Single Point Single Point Single Point University of Utah - Salt Lake City, UT Unit 1 - Solar Taurus 70 CoGen (Turbine and WHRU Duct Burner) AST-2024-0023 1/8/2024 Average Criteria Met Traverse Point 87 of 97 Location: Source: Project No.: Date: Time O2 CO2 NOx (%) (%) (ppm) A-1 12:13 11.82 5.17 4.22 2 12:15 12.09 5.05 4.23 3 12:17 12.19 4.99 4.22 12.0 5.1 4.2 Single Point Single Point Single Point University of Utah - Salt Lake City, UT Unit 6 AST-2024-0023 1/10/2024 Average Criteria Met Traverse Point 88 of 97 Location: Source: Project No.: Date: Time O2 CO2 NOx (%) (%) (ppm) A-1 8:31 11.54 5.35 4.28 2 8:34 11.75 5.24 4.20 3 8:37 11.61 5.32 4.24 11.6 5.3 4.2 Single Point Single Point Single Point University of Utah - Salt Lake City, UT Unit 7 AST-2024-0023 1/10/2024 Average Criteria Met Traverse Point 89 of 97 Location: Source: Project No.: Date: Time O2 CO2 NOx (%) (%) (ppm) A-1 12:50 11.85 5.19 4.08 2 12:52 12.74 4.71 3.48 3 12:54 11.95 5.13 4.16 12.2 5.0 3.9 Single Point Single Point Single Point University of Utah - Salt Lake City, UT Gen 9 Boiler AST-2024-0023 1/9/2024 Average Criteria Met Traverse Point 90 of 97 Appendix D 91 of 97 Attachment A University of Utah - High Temperature Water Plant 2024 Stack Testing Observation Data Burns & McDonnell Field Measurements - Monday January 8 2024 Time (hrs) Total (scf / hour) BTU/scf Input (MMBtu/hr) Total (scf / hour) BTU/scf Input (MMBtu/hr) 12:45 PM --68,756 1,045 72 14,383 1,042 15 1:00 PM 0.25 68,728 1,048 72 19,700 1,048 21 1:15 PM 0.25 66,402 1,044 69 19,632 1,047 21 1:30 PM 0.25 69,113 1,047 72 17,913 1,042 19 1:45 PM 0.25 69,072 1,043 72 28,487 1,044 30 2:00 PM 0.25 66,361 1,045 69 21,313 1,043 22 2:15 PM 0.25 68,921 1,042 72 19,440 1,043 20 2:30 PM 0.25 68,897 1,045 72 24,600 1,044 26 2:45 PM 0.25 68,865 1,042 72 15,700 1,041 16 3:00 PM 0.25 68,841 1,041 72 20,672 1,042 22 3:15 PM 0.25 68,964 1,044 72 18,838 1,046 20 3:30 PM 0.25 68,948 1,041 72 18,768 1,048 20 3:45 PM 0.25 68,980 1,040 72 18,754 1,043 20 4:00 PM 0.25 68,993 1,046 72 18,947 1,044 20 4:15 PM 0.25 68,725 1,041 72 15,697 1,047 16 Average Run Values - Turbine Average Run Values - Duct Burner Summary Average Fuel Use (SCF/hr) Average Fuel Use (MMBtu) Average Fuel Use (SCF/hr) Average Fuel Use (MMBtu/hr) Run 1 68414.2 71.5 1,044 20.92 Run 2 68376.9 71.3 20,345 21.22 Run 3 68922.0 71.8 1,046 19.03 Run 3 - 3:14 PM Time Duct Burner Meter Reading Run 1 - 12:48 PM Run 2 - 2:03 PM 92 of 97 Attachment A University of Utah - High Temperature Water Plant 2024 Stack Testing Observation Data Burns & McDonnell Field Measurements - Tuesday, January 9, 2024 Time (hrs) Total (scf/hour) BTU/scf Input (MMBtu/hr) 8:45 AM --66,437 1,047 69.56 9:00 AM 0.25 69,094 1,041 71.91 9:15 AM 0.25 69,045 1,044 72.08 9:30 AM 0.25 69,037 1,045 72.12 9:45 AM 0.25 69,036 1,044 72.09 10:00 AM 0.25 69,053 1,043 72.03 10:15 AM 0.25 69,028 1,045 72.13 10:30 AM 0.25 69,048 1,046 72.21 10:45 AM 0.25 69,035 1,047 72.26 11:00 AM 0.25 69,039 1,047 72.25 11:15 AM 0.25 69,040 1,047 72.26 11:30 AM 0.25 69,047 1,044 72.11 11:45 AM 0.25 69,054 1,046 72.24 12:00 PM 0.25 69,057 1,045 72.16 12:15 PM 0.25 68,998 1,048 72.31 Average Run Values Summary Average Fuel Use (SCF/hour) Average Fuel Use (MMBtu/hr) Run 1 68,530 72.1 Run 2 69,041 72.3 Run 3 69,039 72.3 Time Run 1 - 8:44 AM Run 2 - 9:58 PM Run 3 - 11:09 AM 93 of 97 Attachment A University of Utah - High Temperature Water Plant 2024 Stack Testing Observation Data Burns & McDonnell Field Measurements - Tuesday, January 9, 2023 Use (lb/hr) USE (SCF/hr) Heat Input (MMBtu/hr)*Load (%) Load MMBtu/hr 12:50 PM 1,360 29,525 30.12 42.09 26.39 1:05 PM 1,331 28,900 29.48 39.95 24.94 1:20 PM 1,363 29,594 30.19 41.60 25.81 1:35 PM 1,345 29,204 29.79 40.90 24.25 1:55 PM 1,271 27,597 28.15 38.70 26.28 2:05 PM 1,299 28,205 28.77 39.40 24.51 2:20 PM 1,216 26,403 26.93 37.10 23.10 2:35 PM 1,144 24,839 25.34 34.90 21.74 2:50 PM 1,102 23,927 24.41 33.60 20.99 3:05 PM 1,190 25,838 26.35 36.40 21.74 3:20 PM 1,138 24,709 25.20 34.60 22.99 3:35 PM 1,118 24,275 24.76 33.80 20.84 3:50 PM 1,020 22,147 22.59 31.10 19.63 4:05 PM 1,105 23,993 24.47 33.80 20.01 4:15 PM 1,191 25,860 26.38 33.20 21.00 Average Run Values Summary Average Fuel Use (lb/hr) Average Fuel Use (Scf/hr) Average Heat Input (MMBtu/hr)* Average Load (%) Average Load (Btu) Run 1 1,328 28,824 29.54 40.65 25.53 Run 2 1,190 25,843 26.66 36.68 23.06 Run 3 1,114 24,197 24.96 33.82 21.04 *Operators expressed uncertainty with system viewer values expressing they may not be reporting the correct fuel usageuse. Time Generator 9 Load Run 1 - 12:50 PM Run 2 - 2:02 PM Run 3 - 2:403:13 PM 94 of 97 Attachment A University of Utah - High Temperature Water Plant 2024 Stack Testing Observation Data Burns & McDonnell Field Measurements - Wednesday, January 10, 2024 Use (scfh)Heat Input (MMBtu/hr)Load (%) Load MMBtu/hr 8:30 AM 18,528 18.90 41.30 15.00 8:45 AM 18,682 19.06 41.40 14.61 9:00 AM 17,709 18.06 39.10 15.50 9:15 AM 18,321 18.69 40.40 15.56 9:30 AM 17,844 18.20 39.10 15.27 9:45 AM 18,249 18.61 39.80 15.22 10:00 AM 17,501 17.85 38.40 14.81 10:15 AM 18,065 18.43 39.80 15.02 10:30 AM 18,244 18.61 40.40 14.85 10:45 AM 19,184 19.57 42.40 16.40 11:00 AM 19,940 20.34 43.90 16.79 11:15 AM 20,769 21.18 45.90 17.25 11:30 AM 20,847 21.26 46.00 17.43 11:45 AM 20,914 21.33 46.10 17.96 12:00 AM 20,606 21.02 45.30 17.13 Average Run Values Summary Average Fuel Use (SCF) Average Heat Input (MMBtu/hr) Average Load (%) Average Load (Btu) Run 1 18,217 18.9 41.30 15.00 Run 2 18,249 18.4 39.50 15.18 Run 3 20,615 20.5 44.29 16.83 Time Boiler Unit 7 Load Run 2 - 9:44 AM Run 3 - 11:01 AM Run 1 - 8:31 AM 95 of 97 Attachment A University of Utah - High Temperature Water Plant 2024 Stack Testing Observation Data Burns & McDonnell Field Measurements - Wednesday, January 10, 2023 Use (scfh)Heat Input (MMBtu/hr)Load (%)Load (MMBtu) 12:15 PM 17,897 18.3 38.60% 17.38 12:30 PM 18,008 28.0 38.60% 17.72 12:45 PM 17,790 18.1 38.40% 17.13 1:00 PM 18,314 18.7 39.50% 17.32 1:15 PM 17,620 18.0 37.90% 17.36 1:30 PM 17,150 17.5 37.00% 17.10 1:45 PM 17,368 17.7 37.50% 16.62 2:00 PM 17,232 17.6 37.20% 16.17 2:15 PM 17,295 17.6 37.00% 16.50 2:30 PM 15,399 15.7 33.10% 15.80 2:45 PM 18,595 19.0 40.60% 17.73 3:00 PM 20,283 20.7 43.70% 18.55 3:15 PM 19,206 19.6 41.30% 18.37 3:30 PM 19,259 19.6 41.50% 18.12 3:45 PM 20,611 21.0 45.10% 19.65 Average Run Values Summary Average Fuel Use (SCF) Average Heat Input (MMBtu/hr) Average Load (%) Average Load (Btu) Run 1 17,926 20.1 38.28% 17.33 Run 2 16,889 17.5 37.08% 16.56 Run 3 19,591 20.0 42.44% 18.48 Time Boiler Unit 6 Load Run 1 - 12:13 PM Run 2 - 1:26 PM Run 3 - 2:37 PM 96 of 97 Last Page of Report 97 of 97 NOx & CO CoGen Combined 2024 Reference Methods 2, 3A, 6C, 7E, 10, & 19 Source Information Company Name University of Utah Company Contact:Bryan Cracroft Contact Phone No.(801) 585-1617 Stack Designation:Solar Taurus 70 CoGen (Combined) Test & Review Dates Test Date:1/8/2024 & Review Date: 2/29/2024 Observer:unobserved Reviewer:Paul Morris Emission Limits Emission Rates SO2 NOX CO SO2 NOX CO lbs./MMBtu lbs./hr. 9.0 10.8 2.586 1.796 ppm 15.0 30.00 7.647 8.727 Percent %O2 Correction as a whole #15.00 15.00 Test Information Heat Input Stack I.D. inches As ft^2 Y Dl H @ Cp Pbar Pq (static) fuel flow rate (Btu/hr.) Heat Input (Btu/hr.) 53.00 15.321 Contractor Information Contact: Charles Horton Contracting Company: Alliance Technical Group, LLC Address: 3683 W 2270 S, Suite E West Valley City, UT 84120 Phone No.: (464) 352-7568 Project No.: 8710 Division of Air Quality Instrumental Reference Methods - Gaseous Measurements Round Method 19 - F factors for Coal, Oil, and Gas Fd Fw Fc scf/MMBtu scf/MMBtu scf/MMBtu Diluent F factor used O2 CO2 Anthrocite 2 Bituminous 2 Lignite Natural Propane Butane 10100 COAL OIL GAS 9780 9860 9190 8710 8710 8710 10540 10640 11950 320 10610 10200 10390 1970 1800 1910 1420 1040 1190 1250 Wet CEM Correct For O2 CO2 Interference w/CO Yes Yes Yes NOx & CO CoGen Combined 2024 Division of Air Quality NSPS Relative Accuracy Performance Specification Test - CEMS Certification University of Utah Solar Taurus 70 CoGen (Combined) Average Emission Dry SO2 NOX CO lbs./MMbtu 0.028 0.020 Average % concentration lbs./hr.2.59 1.80 CO2 O2 ppm corrected for %O2 7.65 8.73 4.87 12.46 Run 1 Enter O2 or CO2 Dry SO2 NOX CO CO2 O2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)2.77E-02 1.95E-02 E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft 1.284E-06 9.067E-07 lbs./hr.2.55 1.80 4.86 12.45 ppm corrected for %O2 7.51 8.71 4.88 12.53 Run 2 Dry SO2 NOX CO CO2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)2.84E-02 1.94E-02 E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft 1.324E-06 9.047E-07 lbs./hr.2.62 1.79 4.89 12.41 ppm corrected for %O2 7.70 8.65 4.88 12.51 Raw Value Run 3 Dry SO2 NOX CO CO2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)2.85E-02 1.98E-02 E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft 1.312E-06 9.105E-07 lbs./hr.2.58 1.79 4.85 12.52 ppm corrected for %O2 7.73 8.818 4.96 12.61 Raw Value Run 4 Dry SO2 NOX CO CO2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft lbs./hr. ppm corrected for %O2 Raw Value Run 5 Dry SO2 NOX CO CO2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft lbs./hr. ppm corrected for %O2 Raw Value C For Cal Drift Raw Value C For Cal Drift C For Cal Drift C For Cal Drift C For Cal Drift O2 CO2 Clear lbs./MMBTU NOx & CO CoGen Combined 2024 Calibration Error Test Test Date January 8, 2024 O2 CS - Cal. Span 24.00 Units % Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 0.00 0.00 0.00% Passed Cal. RR03384 10/19/29 Mid-level 10.00 10.12 0.12 0.50% Passed Cal. High-level 24.00 24.01 0.01 0.04% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of CS - Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 41.67% 100% of Cal. Span High-level 100.00% Test Date January 8, 2024 CO2 CS - Cal. Span 23.70 Units % Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 0.03 0.03 0.127% Passed Cal. RR03384 10/19/29 Mid-level 10.00 10.03 0.03 0.127% Passed Cal. High-level 23.70 23.74 0.04 0.169% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 42.19% 100% of Cal. Span High-level 100.00% Test Date SO2 CS - Cal. Span Units ppm Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level Mid-level High-level % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 40 to 60% of Cal. Span Mid-level 100% of Cal. Span High-level Test Date January 8, 2024 NOx CS - Cal. Span 50.00 Units ppm Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 0.00 0.00 0.000% Passed Cal. CC723464 05/17/29 Mid-level 25.00 24.99 0.01 0.020% Passed Cal. High-level 50.00 49.76 0.24 0.480% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 50.00% 100% of Cal. Span High-level 100.00% Test Date January 8, 2024 CO 10.84 CS - Cal. Span 50.00 30 Units ppm Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 -0.02 0.02 0.040% Passed Cal. CC723464 05/17/29 Mid-level 25.00 25.02 0.02 0.040% Passed Cal. High-level 50.00 50.05 0.05 0.100% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 50.00% 100% of Cal. Span High-level 100.00% Valid Cal Gas Valid Cal Gas Valid Cal Gas Valid Cal Gas NOx & CO CoGen Combined 2024 Division of Air Quality Stack Test Review of University of Utah SO2 NOX CO CO2 O2 Solar Taurus 70 CoGen (Combined) CS Calibration Span 50.00 50.00 23.70 24.00 Units ppm ppm ppm % % Unprotected CV - Cylinder Value: SO2 NOX CO CO2 O2 Low-Level 0.00 0.00 0.00 0.00 Mid-Level 25.00 25.00 10.00 10.00 High-Level 50.00 50.00 23.70 24.00 0 to 20% of Cal. Span 0.00% 0.00% 0.00% 0.00% 40 to 60% of Cal. Span 50.0% 50.0% 42.2% 41.7% 100% of Cal. Span 100.0% 100.0% 100.0% 100.0% Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration. CDir CMA 25.00 25.00 10.00 10.00 Calibration Error Test Cs - Measured Concentration SO2 NOX CO CO2 O2 Low-Level 0.00 -0.02 0.03 0.00 Mid-Level 24.99 25.02 10.03 10.12 High-Level 49.76 50.05 23.74 24.01 Enter Up-scale Analyzer Response to be used during testing. ACE Eq. 7E-1 24.99 25.02 10.03 10.12 Low-Level 0.00% 0.04% 0.13% 0.00% ppmdv Difference 0 0.02 0.03 0 Status Passed Cal. Passed Cal. Passed Cal.Passed Cal. Mid-Level 0.02% 0.04% 0.13% 0.50% ppmdv Difference 0.01 0.02 0.03 0.12 Status Passed Cal. Passed Cal. Passed Cal.Passed Cal. High-Level 0.48% 0.10% 0.17% 0.04% ppmdv Difference 0.24 0.05 0.04 0.01 Status Passed Cal. Passed Cal. Passed Cal.Passed Cal. Pre-Test Sampling System Bias Initial Values SO2 NOX CO CO2 O2 CO - Low-Level 0.24 -0.17 0.05 0.03 System Bias. SBi - Zero Bias TRUE 0.48% 0.30% 0.08% 0.13%± 5% of Span Difference TRUE 0.24 0.15 0.02 0.03 Pass or Failed Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 25.05 25.52 9.94 10.05 SBi - Up-Scale Bias TRUE 0.12% 1.00% 0.38% 0.29% Difference TRUE 0.06 0.50 0.09 0.07 Pass or Failed Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. Raw Test Data Time Start Stop Test Date:1/8/2024 SO2 SO2 NOX CO CO2 O2 NOX 10.9 12.47 4.9 12.5 CO 0.0% 21.7% 24.9% 20.6% 52.2% CO2/O2 Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100 Final Values SO2 NOX CO CO2 O2 CO - Low-Level 0.09 -0.32 0.09 0.08 System Bias. SBi - Zero Bias TRUE 0.18% 0.60% 0.25% 0.33%± 5% of Span Difference TRUE 0.1 0.3 0.1 0.1 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 24.98 24.97 9.98 10.10 SBi - Up-Scale Bias TRUE 0.02% 0.10% 0.21% 0.08% Difference TRUE 0.0 0.1 0.0 0.0 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. Calibration Drift % of Span - D=ABS(SBf - SBi) Low-Level Drift TRUE 0.30% 0.30% 0.17% 0.21% Drift Difference TRUE 0.2 0.2 0.0 0.1 3% of Span Pass or Re-Calibrate Pass Pass Pass Pass Up-scale Gas Drift TRUE 0.10% 0.90% 0.17% 0.21% Difference TRUE 0.1 0.6 0.0 0.0 Pass or Re-Calibrate Pass Pass Pass Pass Solar Taurus 70 CoGen (Combined) Flow & Moisture As ft^2 Pbar Pq (static) Ps Avg Ts F CO2 - FCO2 O2 N2+C Md Ms 15.321 0.00 0.00 0.00 4.86 12.45 82.69 29.28 29.28 Y Cp Vm cf Vlc AVG Tm F Vm std Vw std Bws S Bws #NUM! 0.0000 #DIV/0! 0.999 Load - Megawatts Avg. √∆P's Vs (ft/sec.)Qsw scfh wet Qa acfm Qsd dscfh Heat Input Btu/hr Low Mid High 92.2399996 Enert > #1 - Times Date Point No.∆P √∆P ts F tm F (in) tm F (out) Final Vf Initial Vi 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Failed Bias Dialog Failed Drift Dialog Failed Cal Error Dialog CO Calibration Gas Failed Bias Dialog NOx & CO CoGen Combined 2024 Division of Air Quality Stack Test Review of University of Utah SO2 NOX CO CO2 O2 Solar Taurus 70 CoGen (Combined) CS Calibration Span 50.00 50.00 23.70 24.00 Units ppm ppm ppm % % CV - Cylinder Value:SO2 NOX CO CO2 O2 Low-Level 0.00 0.00 0.00 0.00 Mid-Level 25.00 25.00 10.00 10.00 High-Level 50.00 50.00 23.70 24.00 0 to 20% of Cal. Span 0.00% 0.00% 0.00% 0.00% 40 to 60% of Cal. Span 50.0% 50.0% 42.2% 41.7% 100% of Cal. Span 100.0% 100.0% 100.0% 100.0% Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration. CMA 25.00 25.00 10.00 10.00 Calibration Error Test Measured Concentration SO2 NOX CO CO2 O2 Low-Level 0.00 -0.02 0.03 0.00 Mid-Level 24.99 25.02 10.03 10.12 High-Level 49.76 50.05 23.74 24.01 Enter Up-scale Analyzer Response to be used during testing. ACE Eq. 7E-1 24.99 25.02 10.03 10.12 Low-Level 0.00% 0.04% 0.13% 0.00% ppmdv Difference 0 0.02 0.03 0 Status Passed Cal. Passed Cal. Passed Cal.Passed Cal. Mid-Level 0.02% 0.04% 0.13% 0.50% ppmdv Difference 0.01 0.02 0.03 0.12 Status Passed Cal. Passed Cal. Passed Cal.Passed Cal. High-Level 0.48% 0.10% 0.17% 0.04% ppmdv Difference 0.24 0.05 0.04 0.01 Status Passed Cal. Passed Cal. Passed Cal.Passed Cal. Pre-Test Sampling System Bias Initial Values SO2 NOX CO CO2 O2 CO - Low-Level 0.09 -0.32 0.09 0.08 System Bias. SBi - Zero Bias TRUE 0.18% 0.60% 0.25% 0.33%± 5% of Span Difference TRUE 0.09 0.3 0.06 0.08 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 24.98 24.97 9.98 10.10 SBi - Up-Scale Bias TRUE 0.02% 0.10% 0.21% 0.08% Difference TRUE 0.01 0.05 0.05 0.02 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. Raw Test Data Time Start Stop Test Date:1/8/2024 SO2 SO2 NOX CO CO2 O2 NOX 11.1 12.18 5.0 12.5 CO 0.0% 22.2% 24.4% 20.9% 52.1% CO2/O2 Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100 Final Values SO2 NOX CO CO2 O2 CO - Low-Level 0.08 -0.41 0.13 0.09 System Bias. SBi - Zero Bias TRUE 0.16% 0.78% 0.42% 0.38%± 5% of Span Difference TRUE 0.1 0.4 0.1 0.1 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 24.89 24.71 10.03 10.09 SBi - Up-Scale Bias TRUE 0.20% 0.62% 0.00% 0.12% Difference TRUE 0.1 0.3 0.0 0.0 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. Calibration Drift % of Span - D=ABS(SBf - SBi) Low-Level Drift TRUE 0.02% 0.18% 0.17% 0.04% Response Spec. Difference TRUE 0.0 0.1 0.0 0.0 3% of Span Pass or Re-Calibrate Pass Pass Pass Pass Up-scale Gas Drift TRUE 0.18% 0.52% 0.21% 0.04% Difference TRUE 0.1 0.3 0.0 0.0 Pass or Re-Calibrate Pass Pass Pass Pass Solar Taurus 70 CoGen (Combined) Flow & Moisture As ft^2 Pbar Pq (static) Ps Avg Ts F CO2 - FCO2 O2 N2+C Md Ms 15.32 0.00 0.00 0.00 4.89 12.41 82.70 29.28 29.28 Y Cp Vm cf Vlc AVG Tm F Vm std Vw std Bws S Bws 0.0000 #DIV/0! 0.999 Load - Megawatts Avg. √∆P's Vs Qsw scfh wet Qa acfm Qsd dscfh Heat Input Btu/hr Low Mid High 92.3594979 Enert > #1 - Times Date Point No.∆P √∆P ts F tm F (in) tm F (out) Final Vf Initial Vi 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Failed Bias Dialog Failed Drift Dialog Failed Cal Error Dialog Failed Bias Dialog NOx & CO CoGen Combined 2024 Division of Air Quality Stack Test Review of University of Utah SO2 NOX CO CO2 O2 Solar Taurus 70 CoGen (Combined) CS Calibration Span 50.00 50.00 23.70 24.00 Units ppm ppm ppm % % CV - Cylinder Value:SO2 NOX CO CO2 O2 Low-Level 0.00 0.00 0.00 0.00 Mid-Level 25.00 25.00 10.00 10.00 High-Level 50.00 50.00 23.70 24.00 0 to 20% of Cal. Span 0.00% 0.00% 0.00% 0.00% 40 to 60% of Cal. Span 50.0% 50.0% 42.2% 41.7% 100% of Cal. Span 100.0% 100.0% 100.0% 100.0% Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration. CMA 25.00 25.00 10.00 10.00 Calibration Error Test Measured Concentration SO2 NOX CO CO2 O2 Low-Level 0.00 -0.02 0.03 0.00 Mid-Level 24.99 25.02 10.03 10.12 High-Level 49.76 50.05 23.74 24.01 Enter Up-scale Analyzer Response to be used during testing. ACE Eq. 7E-1 24.99 25.02 10.03 10.12 Low-Level 0.00% 0.04% 0.13% 0.00% ppmv Difference 0 0.02 0.03 0 Status Passed Cal. Passed Cal. Passed Cal.Passed Cal. Mid-Level 0.02% 0.04% 0.13% 0.50% ppmv Difference 0.01 0.02 0.03 0.12 Status Passed Cal. Passed Cal. Passed Cal.Passed Cal. High-Level 0.48% 0.10% 0.17% 0.04% ppmv Difference 0.24 0.05 0.04 0.01 Status Passed Cal. Passed Cal. Passed Cal.Passed Cal. Pre-Test Sampling System Bias Initial Values SO2 NOX CO CO2 O2 CO - Low-Level 0.08 -0.41 0.13 0.09 System Bias. SBi - Zero Bias TRUE 0.16% 0.78% 0.42% 0.38%± 5% of Span Difference TRUE 0.08 0.39 0.1 0.09 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 24.89 24.71 10.03 10.09 SBi - Up-Scale Bias TRUE 0.20% 0.62% 0.00% 0.12% Difference TRUE 0.1 0.31 0 0.03 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. Raw Test Data Time Start Stop Test Date:1/8/2024 SO2 SO2 NOX CO CO2 O2 NOX 11.0 12.15 5.0 12.6 CO 0.0% 22.0% 24.3% 20.9% 52.5% CO2/O2 Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100 Final Values SO2 NOX CO CO2 O2 CO - Low-Level 0.08 -0.50 0.18 0.10 System Bias. SBi - Zero Bias TRUE 0.16% 0.96% 0.63% 0.42%± 5% of Span Difference TRUE 0.1 0.5 0.2 0.1 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 25.04 24.71 10.10 10.09 SBi - Up-Scale Bias TRUE 0.10% 0.62% 0.30% 0.12% Difference TRUE 0.1 0.3 0.1 0.0 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. Calibration Drift % of Span - D=ABS(SBf - SBi) Low-Level Drift TRUE 0.00% 0.18% 0.21% 0.04% Response Spec. Difference TRUE 0.0 0.1 0.1 0.0 3% of Span Pass or Re-Calibrate Pass Pass Pass Pass Up-scale Gas Drift TRUE 0.10% 0.00% 0.30% 0.00% Difference TRUE 0.1 0.0 0.1 0.0 Pass or Re-Calibrate Pass Pass Pass Pass Solar Taurus 70 CoGen (Combined) Flow & Moisture As ft^2 Pbar Pq (static) Ps Avg Ts F CO2 - FCO2 O2 N2+C Md Ms 15.32 0.00 0.00 0.00 4.85 12.52 82.63 29.28 29.28 Y Cp Vm cf Vlc AVG Tm F Vm std Vw std Bws S Bws 0.0000 #DIV/0! 0.999 Load - Megawatts Avg. √∆P's Vs Qsw scfh wet Qa acfm Qsd dscfh Heat Input Btu/hr Low Mid High 90.6948348 Enert > #1 - Times Date Point No.∆P √∆P ts F tm F (in) tm F (out) Final Vf Initial Vi 1 2 3 4 5 6 FT``` 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Failed Bias Dialog Failed Cal Error Dialog Failed Drift Dialog Failed Bias Dialog NOx & CO CoGen Turbine 2024 Reference Methods 2, 3A, 6C, 7E, 10, & 19 Source Information Company Name University of Utah Company Contact:Bryan Cracroft Contact Phone No.(801) 585-1617 Stack Designation:Solar Taurus 70 CoGen (Turbine only) Test & Review Dates Test Date:1/9/2024 & Review Date: 2/28/2024 Observer:unobserved Reviewer:Paul Morris Emission Limits Emission Rates SO2 NOX CO SO2 NOX CO lbs./MMBtu lbs./hr. 2.7 4.5 1.024 0.164 ppm 9.0 25.00 3.870 1.020 Percent %O2 Correction as a whole #15.00 15.00 Test Information Heat Input Stack I.D. inches As ft^2 Y Dl H @ Cp Pbar Pq (static) fuel flow rate (Btu/hr.) Heat Input (Btu/hr.) 53.00 15.321 Contractor Information Contact: Charles Horton Contracting Company: Alliance Technical Group, LLC Address: 3683 W 2270 S, Suite E West Valley City, UT 84120 Phone No.: (464) 352-7568 Project No.: 8710 Division of Air Quality Instrumental Reference Methods - Gaseous Measurements Round Method 19 - F factors for Coal, Oil, and Gas Fd Fw Fc scf/MMBtu scf/MMBtu scf/MMBtu Diluent F factor used O2 CO2 Anthrocite 2 Bituminous 2 Lignite Natural Propane Butane 10100 COAL OIL GAS 9780 9860 9190 8710 8710 8710 10540 10640 11950 320 10610 10200 10390 1970 1800 1910 1420 1040 1190 1250 Wet CEM Correct For O2 CO2 Interference w/CO Yes Yes Yes NOx & CO CoGen Turbine 2024 Division of Air Quality NSPS Relative Accuracy Performance Specification Test - CEMS Certification University of Utah Solar Taurus 70 CoGen (Turbine only) Average Emission Dry SO2 NOX CO lbs./MMbtu 0.014 0.002 Average % concentration lbs./hr.1.02 0.16 CO2 O2 ppm corrected for %O2 3.87 1.02 3.18 15.44 Run 1 Enter O2 or CO2 Dry SO2 NOX CO CO2 O2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)1.27E-02 2.35E-03 E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft 3.785E-07 7.023E-08 lbs./hr.0.91 0.17 3.18 15.47 ppm corrected for %O2 3.44 1.05 3.18 15.47 Run 2 Dry SO2 NOX CO CO2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)1.42E-02 2.22E-03 E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft 4.252E-07 6.666E-08 lbs./hr.1.02 0.16 3.17 15.44 ppm corrected for %O2 3.85 0.99 3.18 15.45 Raw Value Run 3 Dry SO2 NOX CO CO2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)1.59E-02 2.30E-03 E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft 4.801E-07 6.918E-08 lbs./hr.1.15 0.17 3.18 15.42 ppm corrected for %O2 4.32 1.024 3.18 15.41 Raw Value Run 4 Dry SO2 NOX CO CO2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft lbs./hr. ppm corrected for %O2 Raw Value Run 5 Dry SO2 NOX CO CO2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft lbs./hr. ppm corrected for %O2 Raw Value C For Cal Drift Raw Value C For Cal Drift C For Cal Drift C For Cal Drift C For Cal Drift O2 CO2 Clear lbs./MMBTU NOx & CO CoGen Turbine 2024 Calibration Error Test Test Date January 9, 2024 O2 CS - Cal. Span 24.00 Units % Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 0.00 0.00 0.00% Passed Cal. RR03384 10/19/29 Mid-level 10.00 10.10 0.10 0.42% Passed Cal. High-level 24.00 24.03 0.03 0.13% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of CS - Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 41.67% 100% of Cal. Span High-level 100.00% Test Date January 9, 2024 CO2 CS - Cal. Span 23.70 Units % Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 0.04 0.04 0.169% Passed Cal. RR03384 10/19/29 Mid-level 10.00 10.04 0.04 0.169% Passed Cal. High-level 23.70 23.75 0.05 0.211% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 42.19% 100% of Cal. Span High-level 100.00% Test Date SO2 CS - Cal. Span Units ppm Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level Mid-level High-level % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 40 to 60% of Cal. Span Mid-level 100% of Cal. Span High-level Test Date January 9, 2024 NOx CS - Cal. Span 50.00 Units ppm Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 0.00 0.00 0.000% Passed Cal. CC723464 05/17/29 Mid-level 25.00 24.99 0.01 0.020% Passed Cal. High-level 50.00 50.01 0.01 0.020% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 50.00% 100% of Cal. Span High-level 100.00% Test Date January 9, 2024 CO 4.48 CS - Cal. Span 50.00 25 Units ppm Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 -0.02 0.02 0.040% Passed Cal. CC723464 05/17/29 Mid-level 25.00 25.01 0.01 0.020% Passed Cal. High-level 50.00 50.02 0.02 0.040% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 50.00% 100% of Cal. Span High-level 100.00% Valid Cal Gas Valid Cal Gas Valid Cal Gas Valid Cal Gas NOx & CO CoGen Turbine 2024 Division of Air Quality Stack Test Review of University of Utah SO2 NOX CO CO2 O2 Solar Taurus 70 CoGen (Turbine only) CS Calibration Span 50.00 50.00 23.70 24.00 Units ppm ppm ppm % % Unprotected CV - Cylinder Value: SO2 NOX CO CO2 O2 Low-Level 0.00 0.00 0.00 0.00 Mid-Level 25.00 25.00 10.00 10.00 High-Level 50.00 50.00 23.70 24.00 0 to 20% of Cal. Span 0.00% 0.00% 0.00% 0.00% 40 to 60% of Cal. Span 50.0% 50.0% 42.2% 41.7% 100% of Cal. Span 100.0% 100.0% 100.0% 100.0% Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration. CDir CMA 25.00 25.00 10.00 10.00 Calibration Error Test Cs - Measured Concentration SO2 NOX CO CO2 O2 Low-Level 0.00 -0.02 0.04 0.00 Mid-Level 24.99 25.01 10.04 10.10 High-Level 50.01 50.02 23.75 24.03 Enter Up-scale Analyzer Response to be used during testing. ACE Eq. 7E-1 24.99 25.01 10.04 10.10 Low-Level 0.00% 0.04% 0.17% 0.00% ppmdv Difference 0 0.02 0.04 0 Status Passed Cal. Passed Cal. Passed Cal.Passed Cal. Mid-Level 0.02% 0.02% 0.17% 0.42% ppmdv Difference 0.01 0.01 0.04 0.1 Status Passed Cal. Passed Cal. Passed Cal.Passed Cal. High-Level 0.02% 0.04% 0.21% 0.13% ppmdv Difference 0.01 0.02 0.05 0.03 Status Passed Cal. Passed Cal. Passed Cal.Passed Cal. Pre-Test Sampling System Bias Initial Values SO2 NOX CO CO2 O2 CO - Low-Level 0.05 -0.05 0.04 0.00 System Bias. SBi - Zero Bias TRUE 0.10% 0.06% 0.00% 0.00%± 5% of Span Difference TRUE 0.05 0.03 0 0 Pass or Failed Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 25.03 24.98 9.93 10.00 SBi - Up-Scale Bias TRUE 0.08% 0.06% 0.46% 0.42% Difference TRUE 0.04 0.03 0.11 0.10 Pass or Failed Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. Raw Test Data Time Start Stop Test Date:1/9/2024 SO2 SO2 NOX CO CO2 O2 NOX 3.2 0.90 3.2 15.5 CO 0.0% 6.4% 1.8% 13.4% 64.5% CO2/O2 Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100 Final Values SO2 NOX CO CO2 O2 CO - Low-Level 0.06 -0.08 0.04 0.01 System Bias. SBi - Zero Bias TRUE 0.12% 0.12% 0.00% 0.04%± 5% of Span Difference TRUE 0.1 0.1 0.0 0.0 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 25.01 24.84 9.93 10.01 SBi - Up-Scale Bias TRUE 0.04% 0.34% 0.46% 0.37% Difference TRUE 0.0 0.2 0.1 0.1 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. Calibration Drift % of Span - D=ABS(SBf - SBi) Low-Level Drift TRUE 0.02% 0.06% 0.00% 0.04% Drift Difference TRUE 0.0 0.0 0.0 0.0 3% of Span Pass or Re-Calibrate Pass Pass Pass Pass Up-scale Gas Drift TRUE 0.04% 0.28% 0.00% 0.04% Difference TRUE 0.0 0.1 0.0 0.0 Pass or Re-Calibrate Pass Pass Pass Pass Solar Taurus 70 CoGen (Turbine only)Flow & Moisture As ft^2 Pbar Pq (static) Ps Avg Ts F CO2 - FCO2 O2 N2+C Md Ms 15.321 0.00 0.00 0.00 3.18 15.47 81.36 29.13 29.13 Y Cp Vm cf Vlc AVG Tm F Vm std Vw std Bws S Bws #NUM! 0.0000 #DIV/0! 0.999 Load - Megawatts Avg. √∆P's Vs (ft/sec.)Qsw scfh wet Qa acfm Qsd dscfh Heat Input Btu/hr Low Mid High 71.47679 Enert > #1 - Times Date Point No.∆P √∆P ts F tm F (in) tm F (out) Final Vf Initial Vi 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Failed Bias Dialog Failed Drift Dialog Failed Cal Error Dialog CO Calibration Gas Failed Bias Dialog NOx & CO CoGen Turbine 2024 Division of Air Quality Stack Test Review of University of Utah SO2 NOX CO CO2 O2 Solar Taurus 70 CoGen (Turbine only) CS Calibration Span 50.00 50.00 23.70 24.00 Units ppm ppm ppm % % CV - Cylinder Value:SO2 NOX CO CO2 O2 Low-Level 0.00 0.00 0.00 0.00 Mid-Level 25.00 25.00 10.00 10.00 High-Level 50.00 50.00 23.70 24.00 0 to 20% of Cal. Span 0.00% 0.00% 0.00% 0.00% 40 to 60% of Cal. Span 50.0% 50.0% 42.2% 41.7% 100% of Cal. Span 100.0% 100.0% 100.0% 100.0% Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration. CMA 25.00 25.00 10.00 10.00 Calibration Error Test Measured Concentration SO2 NOX CO CO2 O2 Low-Level 0.00 -0.02 0.04 0.00 Mid-Level 24.99 25.01 10.04 10.10 High-Level 50.01 50.02 23.75 24.03 Enter Up-scale Analyzer Response to be used during testing. ACE Eq. 7E-1 24.99 25.01 10.04 10.10 Low-Level 0.00% 0.04% 0.17% 0.00% ppmdv Difference 0 0.02 0.04 0 Status Passed Cal. Passed Cal. Passed Cal.Passed Cal. Mid-Level 0.02% 0.02% 0.17% 0.42% ppmdv Difference 0.01 0.01 0.04 0.1 Status Passed Cal. Passed Cal. Passed Cal.Passed Cal. High-Level 0.02% 0.04% 0.21% 0.13% ppmdv Difference 0.01 0.02 0.05 0.03 Status Passed Cal. Passed Cal. Passed Cal.Passed Cal. Pre-Test Sampling System Bias Initial Values SO2 NOX CO CO2 O2 CO - Low-Level 0.06 -0.08 0.04 0.01 System Bias. SBi - Zero Bias TRUE 0.12% 0.12% 0.00% 0.04%± 5% of Span Difference TRUE 0.06 0.06 0 0.01 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 25.01 24.84 9.93 10.01 SBi - Up-Scale Bias TRUE 0.04% 0.34% 0.46% 0.37% Difference TRUE 0.02 0.17 0.11 0.09 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. Raw Test Data Time Start Stop Test Date:1/9/2024 SO2 SO2 NOX CO CO2 O2 NOX 3.6 0.81 3.2 15.5 CO 0.0% 7.2% 1.6% 13.4% 64.4% CO2/O2 Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100 Final Values SO2 NOX CO CO2 O2 CO - Low-Level 0.07 -0.13 0.05 0.02 System Bias. SBi - Zero Bias TRUE 0.14% 0.22% 0.04% 0.08%± 5% of Span Difference TRUE 0.1 0.1 0.0 0.0 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 24.77 24.85 9.93 10.01 SBi - Up-Scale Bias TRUE 0.44% 0.32% 0.46% 0.37% Difference TRUE 0.2 0.2 0.1 0.1 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. Calibration Drift % of Span - D=ABS(SBf - SBi) Low-Level Drift TRUE 0.02% 0.10% 0.04% 0.04% Response Spec. Difference TRUE 0.0 0.1 0.0 0.0 3% of Span Pass or Re-Calibrate Pass Pass Pass Pass Up-scale Gas Drift TRUE 0.40% 0.02% 0.00% 0.00% Difference TRUE 0.2 0.0 0.0 0.0 Pass or Re-Calibrate Pass Pass Pass Pass Solar Taurus 70 CoGen (Turbine only)Flow & Moisture As ft^2 Pbar Pq (static) Ps Avg Ts F CO2 - FCO2 O2 N2+C Md Ms 15.32 0.00 0.00 0.00 3.17 15.44 81.39 29.13 29.13 Y Cp Vm cf Vlc AVG Tm F Vm std Vw std Bws S Bws 0.0000 #DIV/0! 0.999 Load - Megawatts Avg. √∆P's Vs Qsw scfh wet Qa acfm Qsd dscfh Heat Input Btu/hr Low Mid High 71.871681 Enert > #1 - Times Date Point No.∆P √∆P ts F tm F (in) tm F (out) Final Vf Initial Vi 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Failed Bias Dialog Failed Drift Dialog Failed Cal Error Dialog Failed Bias Dialog NOx & CO CoGen Turbine 2024 Division of Air Quality Stack Test Review of University of Utah SO2 NOX CO CO2 O2 Solar Taurus 70 CoGen (Turbine only) CS Calibration Span 50.00 50.00 23.70 24.00 Units ppm ppm ppm % % CV - Cylinder Value:SO2 NOX CO CO2 O2 Low-Level 0.00 0.00 0.00 0.00 Mid-Level 25.00 25.00 10.00 10.00 High-Level 50.00 50.00 23.70 24.00 0 to 20% of Cal. Span 0.00% 0.00% 0.00% 0.00% 40 to 60% of Cal. Span 50.0% 50.0% 42.2% 41.7% 100% of Cal. Span 100.0% 100.0% 100.0% 100.0% Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration. CMA 25.00 25.00 10.00 10.00 Calibration Error Test Measured Concentration SO2 NOX CO CO2 O2 Low-Level 0.00 -0.02 0.04 0.00 Mid-Level 24.99 25.01 10.04 10.10 High-Level 50.01 50.02 23.75 24.03 Enter Up-scale Analyzer Response to be used during testing. ACE Eq. 7E-1 24.99 25.01 10.04 10.10 Low-Level 0.00% 0.04% 0.17% 0.00% ppmv Difference 0 0.02 0.04 0 Status Passed Cal. Passed Cal. Passed Cal.Passed Cal. Mid-Level 0.02% 0.02% 0.17% 0.42% ppmv Difference 0.01 0.01 0.04 0.1 Status Passed Cal. Passed Cal. Passed Cal.Passed Cal. High-Level 0.02% 0.04% 0.21% 0.13% ppmv Difference 0.01 0.02 0.05 0.03 Status Passed Cal. Passed Cal. Passed Cal.Passed Cal. Pre-Test Sampling System Bias Initial Values SO2 NOX CO CO2 O2 CO - Low-Level 0.07 -0.13 0.05 0.02 System Bias. SBi - Zero Bias TRUE 0.14% 0.22% 0.04% 0.08%± 5% of Span Difference TRUE 0.07 0.11 0.01 0.02 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 24.77 24.85 9.93 10.01 SBi - Up-Scale Bias TRUE 0.44% 0.32% 0.46% 0.37% Difference TRUE 0.22 0.16 0.11 0.09 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. Raw Test Data Time Start Stop Test Date:1/9/2024 SO2 SO2 NOX CO CO2 O2 NOX 4.1 0.80 3.2 15.4 CO 0.0% 8.1% 1.6% 13.4% 64.2% CO2/O2 Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100 Final Values SO2 NOX CO CO2 O2 CO - Low-Level 0.09 -0.17 0.03 0.03 System Bias. SBi - Zero Bias TRUE 0.18% 0.30% 0.04% 0.13%± 5% of Span Difference TRUE 0.1 0.2 0.0 0.0 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 24.78 24.77 9.89 10.00 SBi - Up-Scale Bias TRUE 0.42% 0.48% 0.63% 0.42% Difference TRUE 0.2 0.2 0.1 0.1 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. Calibration Drift % of Span - D=ABS(SBf - SBi) Low-Level Drift TRUE 0.04% 0.08% 0.00% 0.04% Response Spec. Difference TRUE 0.0 0.0 0.0 0.0 3% of Span Pass or Re-Calibrate Pass Pass Pass Pass Up-scale Gas Drift TRUE 0.02% 0.16% 0.17% 0.04% Difference TRUE 0.0 0.1 0.0 0.0 Pass or Re-Calibrate Pass Pass Pass Pass Solar Taurus 70 CoGen (Turbine only)Flow & Moisture As ft^2 Pbar Pq (static) Ps Avg Ts F CO2 - FCO2 O2 N2+C Md Ms 15.32 0.00 0.00 0.00 3.18 15.42 81.40 29.13 29.13 Y Cp Vm cf Vlc AVG Tm F Vm std Vw std Bws S Bws 0.0000 #DIV/0! 0.999 Load - Megawatts Avg. √∆P's Vs Qsw scfh wet Qa acfm Qsd dscfh Heat Input Btu/hr Low Mid High 71.869599 Enert > #1 - Times Date Point No.∆P √∆P ts F tm F (in) tm F (out) Final Vf Initial Vi 1 2 3 4 5 6 FT``` 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Failed Bias Dialog Failed Cal Error Dialog Failed Drift Dialog Failed Bias Dialog NOx Unit 6 2024 Reference Methods 2, 3A, 6C, 7E, 10, & 19 Source Information Company Name University of Utah Company Contact:Bryan Cracroft Contact Phone No.(801) 585-1617 Stack Designation:Unit 6 Test & Review Dates Test Date:1/10/2024 & Review Date: 2/29/2024 Observer:Unobserved Reviewer:Paul Morris Emission Limits Emission Rates SO2 NOX CO SO2 NOX CO lbs./MMBtu lbs./hr. 0.5 0.187 ppm 9.0 8.110 Percent %O2 Correction as a whole #3.00 Test Information Heat Input Stack I.D. inches As ft^2 Y Dl H @ Cp Pbar Pq (static) fuel flow rate (Btu/hr.) Heat Input (Btu/hr.) 32.00 5.585 Contractor Information Contact: Charles Horton Contracting Company: Alliance Technical Group, LLC Address: 3683 W 2270 S, Suite E West Valley City, UT 84120 Phone No.: (464) 352-7568 Project No.: 8710 Division of Air Quality Instrumental Reference Methods - Gaseous Measurements Round Method 19 - F factors for Coal, Oil, and Gas Fd Fw Fc scf/MMBtu scf/MMBtu scf/MMBtu Diluent F factor used O2 CO2 Anthrocite 2 Bituminous 2 Lignite Natural Propane Butane 10100 COAL OIL GAS 9780 9860 9190 8710 8710 8710 10540 10640 11950 320 10610 10200 10390 1970 1800 1910 1420 1040 1190 1250 Wet CEM Correct For O2 CO2 Interference w/CO Yes Yes Yes NOx Unit 6 2024 Division of Air Quality NSPS Relative Accuracy Performance Specification Test - CEMS Certification University of Utah Unit 6 Average Emission Dry SO2 NOX CO lbs./MMbtu 0.010 Average % concentration lbs./hr.0.19 CO2 O2 ppm corrected for %O2 8.11 4.82 12.55 Run 1 Enter O2 or CO2 Dry SO2 NOX CO CO2 O2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)1.01E-02 E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft 4.649E-07 lbs./hr.0.19 4.88 12.49 ppm corrected for %O2 8.29 4.83 12.46 Run 2 Dry SO2 NOX CO CO2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)1.02E-02 E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft 4.662E-07 lbs./hr.0.18 4.80 12.60 ppm corrected for %O2 8.42 4.83 12.55 Raw Value Run 3 Dry SO2 NOX CO CO2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)9.26E-03 E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft 4.239E-07 lbs./hr.0.19 4.79 12.57 ppm corrected for %O2 7.62 4.78 12.50 Raw Value Run 4 Dry SO2 NOX CO CO2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft lbs./hr. ppm corrected for %O2 Raw Value Run 5 Dry SO2 NOX CO CO2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft lbs./hr. ppm corrected for %O2 Raw Value C For Cal Drift Raw Value C For Cal Drift C For Cal Drift C For Cal Drift C For Cal Drift O2 CO2 Clear lbs./MMBTU NOx Unit 6 2024 Calibration Error Test Test Date January 10, 2024 O2 CS - Cal. Span 24.00 Units % Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 0.00 0.00 0.00% Passed Cal. RR03384 10/19/29 Mid-level 10.00 10.10 0.10 0.42% Passed Cal. High-level 24.00 24.00 0.00 0.00% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of CS - Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 41.67% 100% of Cal. Span High-level 100.00% Test Date January 10, 2024 CO2 CS - Cal. Span 23.70 Units % Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 0.04 0.04 0.169% Passed Cal. RR03384 10/19/29 Mid-level 10.00 10.04 0.04 0.169% Passed Cal. High-level 23.70 23.73 0.03 0.127% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 42.19% 100% of Cal. Span High-level 100.00% Test Date SO2 CS - Cal. Span Units ppm Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level Mid-level High-level % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 40 to 60% of Cal. Span Mid-level 100% of Cal. Span High-level Test Date January 10, 2024 NOx CS - Cal. Span 30.00 Units ppm Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 0.00 0.00 0.000% Passed Cal. CC723464 05/17/29 Mid-level 15.00 15.01 0.01 0.033% Passed Cal. High-level 30.00 29.98 0.02 0.067% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 50.00% 100% of Cal. Span High-level 100.00% Test Date CO CS - Cal. Span Units ppm Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level Mid-level High-level % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 40 to 60% of Cal. Span Mid-level 100% of Cal. Span High-level Valid Cal Gas Valid Cal Gas Valid Cal Gas NOx Unit 6 2024 Division of Air Quality Stack Test Review of University of Utah SO2 NOX CO CO2 O2 Unit 6 CS Calibration Span 30.00 23.70 24.00 Units ppm ppm ppm % % Unprotected CV - Cylinder Value: SO2 NOX CO CO2 O2 Low-Level 0.00 0.00 0.00 Mid-Level 15.00 10.00 10.00 High-Level 30.00 23.70 24.00 0 to 20% of Cal. Span 0.00% 0.00% 0.00% 40 to 60% of Cal. Span 50.0% 42.2% 41.7% 100% of Cal. Span 100.0% 100.0% 100.0% Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration. CDir CMA 15.00 10.00 10.00 Calibration Error Test Cs - Measured Concentration SO2 NOX CO CO2 O2 Low-Level 0.00 0.04 0.00 Mid-Level 15.01 10.04 10.10 High-Level 29.98 23.73 24.00 Enter Up-scale Analyzer Response to be used during testing. ACE Eq. 7E-1 15.01 10.04 10.10 Low-Level 0.00% 0.17% 0.00% ppmdv Difference 0 0.04 0 Status Passed Cal. Passed Cal.Passed Cal. Mid-Level 0.03% 0.17% 0.42% ppmdv Difference 0.01 0.04 0.1 Status Passed Cal. Passed Cal.Passed Cal. High-Level 0.07% 0.13% 0.00% ppmdv Difference 0.02 0.03 0 Status Passed Cal. Passed Cal.Passed Cal. Pre-Test Sampling System Bias Initial Values SO2 NOX CO CO2 O2 CO - Low-Level 0.05 0.03 0.00 System Bias. SBi - Zero Bias TRUE 0.17% TRUE 0.04% 0.00%± 5% of Span Difference TRUE 0.05 TRUE 0.01 0 Pass or Failed Invalid Run Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 15.01 9.89 9.98 SBi - Up-Scale Bias TRUE 0.00% TRUE 0.63% 0.50% Difference TRUE 0.00 TRUE 0.15 0.12 Pass or Failed Invalid Run Passed Cal. Passed Cal. Passed Cal. Raw Test Data Time Start Stop Test Date:1/10/2024 SO2 SO2 NOX CO CO2 O2 NOX 3.9 4.8 12.5 CO 0.0% 13.1% 0.0% 20.4% 51.9% CO2/O2 Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100 Final Values SO2 NOX CO CO2 O2 CO - Low-Level 0.05 0.03 0.01 System Bias. SBi - Zero Bias TRUE 0.17% TRUE 0.04% 0.04%± 5% of Span Difference TRUE 0.1 TRUE 0.0 0.0 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 15.00 9.85 9.97 SBi - Up-Scale Bias TRUE 0.03% TRUE 0.80% 0.54% Difference TRUE 0.0 TRUE 0.2 0.1 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Calibration Drift % of Span - D=ABS(SBf - SBi) Low-Level Drift TRUE 0.00% TRUE 0.00% 0.04% Drift Difference TRUE 0.0 TRUE 0.0 0.0 3% of Span Pass or Re-Calibrate Pass Pass Pass Up-scale Gas Drift TRUE 0.03% TRUE 0.17% 0.04% Difference TRUE 0.0 TRUE 0.0 0.0 Pass or Re-Calibrate Pass Pass Pass Unit 6 Flow & Moisture As ft^2 Pbar Pq (static) Ps Avg Ts F CO2 - FCO2 O2 N2+C Md Ms 5.585 0.00 0.00 0.00 4.88 12.49 82.63 29.28 29.28 Y Cp Vm cf Vlc AVG Tm F Vm std Vw std Bws S Bws #NUM! 0.0000 #DIV/0! 0.999 Load - Megawatts Avg. √∆P's Vs (ft/sec.)Qsw scfh wet Qa acfm Qsd dscfh Heat Input Btu/hr Low Mid High 18.8223 Enert > #1 - Times Date Point No.∆P √∆P ts F tm F (in) tm F (out) Final Vf Initial Vi 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Failed Bias Dialog Failed Drift Dialog Failed Cal Error Dialog CO Calibration Gas Failed Bias Dialog NOx Unit 6 2024 Division of Air Quality Stack Test Review of University of Utah SO2 NOX CO CO2 O2 Unit 6 CS Calibration Span 30.00 23.70 24.00 Units ppm ppm ppm % % CV - Cylinder Value:SO2 NOX CO CO2 O2 Low-Level 0.00 0.00 0.00 Mid-Level 15.00 10.00 10.00 High-Level 30.00 23.70 24.00 0 to 20% of Cal. Span 0.00% 0.00% 0.00% 40 to 60% of Cal. Span 50.0% 42.2% 41.7% 100% of Cal. Span 100.0% 100.0% 100.0% Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration. CMA 15.00 10.00 10.00 Calibration Error Test Measured Concentration SO2 NOX CO CO2 O2 Low-Level 0.00 0.04 0.00 Mid-Level 15.01 10.04 10.10 High-Level 29.98 23.73 24.00 Enter Up-scale Analyzer Response to be used during testing. ACE Eq. 7E-1 15.01 10.04 10.10 Low-Level 0.00% 0.17% 0.00% ppmdv Difference 0 0.04 0 Status Passed Cal. Passed Cal.Passed Cal. Mid-Level 0.03% 0.17% 0.42% ppmdv Difference 0.01 0.04 0.1 Status Passed Cal. Passed Cal.Passed Cal. High-Level 0.07% 0.13% 0.00% ppmdv Difference 0.02 0.03 0 Status Passed Cal. Passed Cal.Passed Cal. Pre-Test Sampling System Bias Initial Values SO2 NOX CO CO2 O2 CO - Low-Level 0.05 0.03 0.01 System Bias. SBi - Zero Bias TRUE 0.17% TRUE 0.04% 0.04%± 5% of Span Difference TRUE 0.05 TRUE 0.01 0.01 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 15.00 9.85 9.97 SBi - Up-Scale Bias TRUE 0.03% TRUE 0.80% 0.54% Difference TRUE 0.01 TRUE 0.19 0.13 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Raw Test Data Time Start Stop Test Date:1/10/2024 SO2 SO2 NOX CO CO2 O2 NOX 3.9 4.8 12.6 CO 0.0% 13.1% 0.0% 20.1% 52.3% CO2/O2 Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100 Final Values SO2 NOX CO CO2 O2 CO - Low-Level 0.05 0.03 0.02 System Bias. SBi - Zero Bias TRUE 0.17% TRUE 0.04% 0.08%± 5% of Span Difference TRUE 0.1 TRUE 0.0 0.0 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 15.00 9.93 9.95 SBi - Up-Scale Bias TRUE 0.03% TRUE 0.46% 0.63% Difference TRUE 0.0 TRUE 0.1 0.2 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Calibration Drift % of Span - D=ABS(SBf - SBi) Low-Level Drift TRUE 0.00% TRUE 0.00% 0.04% Response Spec. Difference TRUE 0.0 TRUE 0.0 0.0 3% of Span Pass or Re-Calibrate Pass Pass Pass Up-scale Gas Drift TRUE 0.00% TRUE 0.34% 0.08% Difference TRUE 0.0 TRUE 0.1 0.0 Pass or Re-Calibrate Pass Pass Pass Unit 6 Flow & Moisture As ft^2 Pbar Pq (static) Ps Avg Ts F CO2 - FCO2 O2 N2+C Md Ms 5.59 0.00 0.00 0.00 4.80 12.60 82.60 29.27 29.27 Y Cp Vm cf Vlc AVG Tm F Vm std Vw std Bws S Bws 0.0000 #DIV/0! 0.999 Load - Megawatts Avg. √∆P's Vs Qsw scfh wet Qa acfm Qsd dscfh Heat Input Btu/hr Low Mid High 17.73345 Enert > #1 - Times Date Point No.∆P √∆P ts F tm F (in) tm F (out) Final Vf Initial Vi 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Failed Bias Dialog Failed Drift Dialog Failed Cal Error Dialog Failed Bias Dialog NOx Unit 6 2024 Division of Air Quality Stack Test Review of University of Utah SO2 NOX CO CO2 O2 Unit 6 CS Calibration Span 30.00 23.70 24.00 Units ppm ppm ppm % % CV - Cylinder Value:SO2 NOX CO CO2 O2 Low-Level 0.00 0.00 0.00 Mid-Level 15.00 10.00 10.00 High-Level 30.00 23.70 24.00 0 to 20% of Cal. Span 0.00% 0.00% 0.00% 40 to 60% of Cal. Span 50.0% 42.2% 41.7% 100% of Cal. Span 100.0% 100.0% 100.0% Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration. CMA 15.00 10.00 10.00 Calibration Error Test Measured Concentration SO2 NOX CO CO2 O2 Low-Level 0.00 0.04 0.00 Mid-Level 15.01 10.04 10.10 High-Level 29.98 23.73 24.00 Enter Up-scale Analyzer Response to be used during testing. ACE Eq. 7E-1 15.01 10.04 10.10 Low-Level 0.00% 0.17% 0.00% ppmv Difference 0 0.04 0 Status Passed Cal. Passed Cal.Passed Cal. Mid-Level 0.03% 0.17% 0.42% ppmv Difference 0.01 0.04 0.1 Status Passed Cal. Passed Cal.Passed Cal. High-Level 0.07% 0.13% 0.00% ppmv Difference 0.02 0.03 0 Status Passed Cal. Passed Cal.Passed Cal. Pre-Test Sampling System Bias Initial Values SO2 NOX CO CO2 O2 CO - Low-Level 0.05 0.03 0.02 System Bias. SBi - Zero Bias TRUE 0.17% TRUE 0.04% 0.08%± 5% of Span Difference TRUE 0.05 TRUE 0.01 0.02 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 15.00 9.93 9.95 SBi - Up-Scale Bias TRUE 0.03% TRUE 0.46% 0.63% Difference TRUE 0.01 TRUE 0.11 0.15 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Raw Test Data Time Start Stop Test Date:1/10/2024 SO2 SO2 NOX CO CO2 O2 NOX 3.6 4.8 12.5 CO 0.0% 12.0% 0.0% 20.2% 52.1% CO2/O2 Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100 Final Values SO2 NOX CO CO2 O2 CO - Low-Level 0.05 0.02 0.02 System Bias. SBi - Zero Bias TRUE 0.17% TRUE 0.08% 0.08%± 5% of Span Difference TRUE 0.1 TRUE 0.0 0.0 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 15.02 9.97 9.95 SBi - Up-Scale Bias TRUE 0.03% TRUE 0.30% 0.63% Difference TRUE 0.0 TRUE 0.1 0.2 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Calibration Drift % of Span - D=ABS(SBf - SBi) Low-Level Drift TRUE 0.00% TRUE 0.04% 0.00% Response Spec. Difference TRUE 0.0 TRUE 0.0 0.0 3% of Span Pass or Re-Calibrate Pass Pass Pass Up-scale Gas Drift TRUE 0.00% TRUE 0.17% 0.00% Difference TRUE 0.0 TRUE 0.0 0.0 Pass or Re-Calibrate Pass Pass Pass Unit 6 Flow & Moisture As ft^2 Pbar Pq (static) Ps Avg Ts F CO2 - FCO2 O2 N2+C Md Ms 5.59 0.00 0.00 0.00 4.79 12.57 82.64 29.27 29.27 Y Cp Vm cf Vlc AVG Tm F Vm std Vw std Bws S Bws 0.0000 #DIV/0! 0.999 Load - Megawatts Avg. √∆P's Vs Qsw scfh wet Qa acfm Qsd dscfh Heat Input Btu/hr Low Mid High 20.57055 Enert > #1 - Times Date Point No.∆P √∆P ts F tm F (in) tm F (out) Final Vf Initial Vi 1 2 3 4 5 6 FT``` 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Failed Bias Dialog Failed Cal Error Dialog Failed Drift Dialog Failed Bias Dialog NOx Unit 7 2024 Reference Methods 2, 3A, 6C, 7E, 10, & 19 Source Information Company Name University of Utah Company Contact:Bryan Cracroft Contact Phone No.(801) 585-1617 Stack Designation:Unit 7 Test & Review Dates Test Date:1/10/2024 & Review Date: 2/29/2024 Observer:Unobserved Reviewer:Paul Morris Emission Limits Emission Rates SO2 NOX CO SO2 NOX CO lbs./MMBtu lbs./hr. 0.5 0.199 ppm 9.0 8.227 Percent %O2 Correction as a whole #3.00 Test Information Heat Input Stack I.D. inches As ft^2 Y Dl H @ Cp Pbar Pq (static) fuel flow rate (Btu/hr.) Heat Input (Btu/hr.) 32.00 5.585 Contractor Information Contact: Charles Horton Contracting Company: Alliance Technical Group, LLC Address: 3683 W 2270 S, Suite E West Valley City, UT 84120 Phone No.: (464) 352-7568 Project No.: 8710 Division of Air Quality Instrumental Reference Methods - Gaseous Measurements Round Method 19 - F factors for Coal, Oil, and Gas Fd Fw Fc scf/MMBtu scf/MMBtu scf/MMBtu Diluent F factor used O2 CO2 Anthrocite 2 Bituminous 2 Lignite Natural Propane Butane 10100 COAL OIL GAS 9780 9860 9190 8710 8710 8710 10540 10640 11950 320 10610 10200 10390 1970 1800 1910 1420 1040 1190 1250 Wet CEM Correct For O2 CO2 Interference w/CO Yes Yes Yes NOx Unit 7 2024 Division of Air Quality NSPS Relative Accuracy Performance Specification Test - CEMS Certification University of Utah Unit 7 Average Emission Dry SO2 NOX CO lbs./MMbtu 0.010 Average % concentration lbs./hr.0.20 CO2 O2 ppm corrected for %O2 8.23 5.35 11.59 Run 1 Enter O2 or CO2 Dry SO2 NOX CO CO2 O2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)1.01E-02 E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft 5.152E-07 lbs./hr.0.19 5.34 11.60 ppm corrected for %O2 8.30 5.32 11.62 Run 2 Dry SO2 NOX CO CO2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)1.03E-02 E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft 5.229E-07 lbs./hr.0.20 5.32 11.64 ppm corrected for %O2 8.46 5.32 11.66 Raw Value Run 3 Dry SO2 NOX CO CO2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)9.62E-03 E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft 4.951E-07 lbs./hr.0.21 5.38 11.53 ppm corrected for %O2 7.92 5.34 11.53 Raw Value Run 4 Dry SO2 NOX CO CO2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft lbs./hr. ppm corrected for %O2 Raw Value Run 5 Dry SO2 NOX CO CO2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft lbs./hr. ppm corrected for %O2 Raw Value C For Cal Drift Raw Value C For Cal Drift C For Cal Drift C For Cal Drift C For Cal Drift O2 CO2 Clear lbs./MMBTU NOx Unit 7 2024 Calibration Error Test Test Date January 10, 2024 O2 CS - Cal. Span 24.00 Units % Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 0.00 0.00 0.00% Passed Cal. RR03384 10/19/29 Mid-level 10.00 10.10 0.10 0.42% Passed Cal. High-level 24.00 24.00 0.00 0.00% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of CS - Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 41.67% 100% of Cal. Span High-level 100.00% Test Date January 10, 2024 CO2 CS - Cal. Span 23.70 Units % Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 0.04 0.04 0.169% Passed Cal. RR03384 10/19/29 Mid-level 10.00 10.04 0.04 0.169% Passed Cal. High-level 23.70 23.73 0.03 0.127% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 42.19% 100% of Cal. Span High-level 100.00% Test Date SO2 CS - Cal. Span Units ppm Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level Mid-level High-level % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 40 to 60% of Cal. Span Mid-level 100% of Cal. Span High-level Test Date January 10, 2024 NOx CS - Cal. Span 30.00 Units ppm Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 0.00 0.00 0.000% Passed Cal. CC723464 05/17/29 Mid-level 15.00 15.01 0.01 0.033% Passed Cal. High-level 30.00 29.98 0.02 0.067% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 50.00% 100% of Cal. Span High-level 100.00% Test Date CO CS - Cal. Span Units ppm Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level Mid-level High-level % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 40 to 60% of Cal. Span Mid-level 100% of Cal. Span High-level Valid Cal Gas Valid Cal Gas Valid Cal Gas NOx Unit 7 2024 Division of Air Quality Stack Test Review of University of Utah SO2 NOX CO CO2 O2 Unit 7 CS Calibration Span 30.00 23.70 24.00 Units ppm ppm ppm % % Unprotected CV - Cylinder Value: SO2 NOX CO CO2 O2 Low-Level 0.00 0.00 0.00 Mid-Level 15.00 10.00 10.00 High-Level 30.00 23.70 24.00 0 to 20% of Cal. Span 0.00% 0.00% 0.00% 40 to 60% of Cal. Span 50.0% 42.2% 41.7% 100% of Cal. Span 100.0% 100.0% 100.0% Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration. CDir CMA 15.00 10.00 10.00 Calibration Error Test Cs - Measured Concentration SO2 NOX CO CO2 O2 Low-Level 0.00 0.04 0.00 Mid-Level 15.01 10.04 10.10 High-Level 29.98 23.73 24.00 Enter Up-scale Analyzer Response to be used during testing. ACE Eq. 7E-1 15.01 10.04 10.10 Low-Level 0.00% 0.17% 0.00% ppmdv Difference 0 0.04 0 Status Passed Cal. Passed Cal.Passed Cal. Mid-Level 0.03% 0.17% 0.42% ppmdv Difference 0.01 0.04 0.1 Status Passed Cal. Passed Cal.Passed Cal. High-Level 0.07% 0.13% 0.00% ppmdv Difference 0.02 0.03 0 Status Passed Cal. Passed Cal.Passed Cal. Pre-Test Sampling System Bias Initial Values SO2 NOX CO CO2 O2 CO - Low-Level 0.02 0.04 0.00 System Bias. SBi - Zero Bias TRUE 0.07% TRUE 0.00% 0.00%± 5% of Span Difference TRUE 0.02 TRUE 0 0 Pass or Failed Invalid Run Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 15.02 9.93 10.02 SBi - Up-Scale Bias TRUE 0.03% TRUE 0.46% 0.33% Difference TRUE 0.01 TRUE 0.11 0.08 Pass or Failed Invalid Run Passed Cal. Passed Cal. Passed Cal. Raw Test Data Time Start Stop Test Date:1/10/2024 SO2 SO2 NOX CO CO2 O2 NOX 4.3 5.3 11.6 CO 0.0% 14.5% 0.0% 22.4% 48.4% CO2/O2 Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100 Final Values SO2 NOX CO CO2 O2 CO - Low-Level 0.04 0.05 0.01 System Bias. SBi - Zero Bias TRUE 0.13% TRUE 0.04% 0.04%± 5% of Span Difference TRUE 0.0 TRUE 0.0 0.0 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 15.02 9.93 10.02 SBi - Up-Scale Bias TRUE 0.03% TRUE 0.46% 0.33% Difference TRUE 0.0 TRUE 0.1 0.1 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Calibration Drift % of Span - D=ABS(SBf - SBi) Low-Level Drift TRUE 0.07% TRUE 0.04% 0.04% Drift Difference TRUE 0.0 TRUE 0.0 0.0 3% of Span Pass or Re-Calibrate Pass Pass Pass Up-scale Gas Drift TRUE 0.00% TRUE 0.00% 0.00% Difference TRUE 0.0 TRUE 0.0 0.0 Pass or Re-Calibrate Pass Pass Pass Unit 7 Flow & Moisture As ft^2 Pbar Pq (static) Ps Avg Ts F CO2 - FCO2 O2 N2+C Md Ms 5.585 0.00 0.00 0.00 5.34 11.60 83.07 29.32 29.32 Y Cp Vm cf Vlc AVG Tm F Vm std Vw std Bws S Bws #NUM! 0.0000 #DIV/0! 0.999 Load - Megawatts Avg. √∆P's Vs (ft/sec.)Qsw scfh wet Qa acfm Qsd dscfh Heat Input Btu/hr Low Mid High 19.12785 Enert > #1 - Times Date Point No.∆P √∆P ts F tm F (in) tm F (out) Final Vf Initial Vi 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Failed Bias Dialog Failed Drift Dialog Failed Cal Error Dialog CO Calibration Gas Failed Bias Dialog NOx Unit 7 2024 Division of Air Quality Stack Test Review of University of Utah SO2 NOX CO CO2 O2 Unit 7 CS Calibration Span 30.00 23.70 24.00 Units ppm ppm ppm % % CV - Cylinder Value:SO2 NOX CO CO2 O2 Low-Level 0.00 0.00 0.00 Mid-Level 15.00 10.00 10.00 High-Level 30.00 23.70 24.00 0 to 20% of Cal. Span 0.00% 0.00% 0.00% 40 to 60% of Cal. Span 50.0% 42.2% 41.7% 100% of Cal. Span 100.0% 100.0% 100.0% Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration. CMA 15.00 10.00 10.00 Calibration Error Test Measured Concentration SO2 NOX CO CO2 O2 Low-Level 0.00 0.04 0.00 Mid-Level 15.01 10.04 10.10 High-Level 29.98 23.73 24.00 Enter Up-scale Analyzer Response to be used during testing. ACE Eq. 7E-1 15.01 10.04 10.10 Low-Level 0.00% 0.17% 0.00% ppmdv Difference 0 0.04 0 Status Passed Cal. Passed Cal.Passed Cal. Mid-Level 0.03% 0.17% 0.42% ppmdv Difference 0.01 0.04 0.1 Status Passed Cal. Passed Cal.Passed Cal. High-Level 0.07% 0.13% 0.00% ppmdv Difference 0.02 0.03 0 Status Passed Cal. Passed Cal.Passed Cal. Pre-Test Sampling System Bias Initial Values SO2 NOX CO CO2 O2 CO - Low-Level 0.04 0.05 0.01 System Bias. SBi - Zero Bias TRUE 0.13% TRUE 0.04% 0.04%± 5% of Span Difference TRUE 0.04 TRUE 0.01 0.01 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 15.02 9.93 10.02 SBi - Up-Scale Bias TRUE 0.03% TRUE 0.46% 0.33% Difference TRUE 0.01 TRUE 0.11 0.08 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Raw Test Data Time Start Stop Test Date:1/10/2024 SO2 SO2 NOX CO CO2 O2 NOX 4.4 5.3 11.7 CO 0.0% 14.7% 0.0% 22.4% 48.6% CO2/O2 Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100 Final Values SO2 NOX CO CO2 O2 CO - Low-Level 0.05 0.04 0.01 System Bias. SBi - Zero Bias TRUE 0.17% TRUE 0.00% 0.04%± 5% of Span Difference TRUE 0.1 TRUE 0.0 0.0 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 14.98 9.90 10.02 SBi - Up-Scale Bias TRUE 0.10% TRUE 0.59% 0.33% Difference TRUE 0.0 TRUE 0.1 0.1 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Calibration Drift % of Span - D=ABS(SBf - SBi) Low-Level Drift TRUE 0.03% TRUE 0.04% 0.00% Response Spec. Difference TRUE 0.0 TRUE 0.0 0.0 3% of Span Pass or Re-Calibrate Pass Pass Pass Up-scale Gas Drift TRUE 0.07% TRUE 0.13% 0.00% Difference TRUE 0.0 TRUE 0.0 0.0 Pass or Re-Calibrate Pass Pass Pass Unit 7 Flow & Moisture As ft^2 Pbar Pq (static) Ps Avg Ts F CO2 - FCO2 O2 N2+C Md Ms 5.59 0.00 0.00 0.00 5.32 11.64 83.04 29.32 29.32 Y Cp Vm cf Vlc AVG Tm F Vm std Vw std Bws S Bws 0.0000 #DIV/0! 0.999 Load - Megawatts Avg. √∆P's Vs Qsw scfh wet Qa acfm Qsd dscfh Heat Input Btu/hr Low Mid High 19.16145 Enert > #1 - Times Date Point No.∆P √∆P ts F tm F (in) tm F (out) Final Vf Initial Vi 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Failed Bias Dialog Failed Drift Dialog Failed Cal Error Dialog Failed Bias Dialog NOx Unit 7 2024 Division of Air Quality Stack Test Review of University of Utah SO2 NOX CO CO2 O2 Unit 7 CS Calibration Span 30.00 23.70 24.00 Units ppm ppm ppm % % CV - Cylinder Value:SO2 NOX CO CO2 O2 Low-Level 0.00 0.00 0.00 Mid-Level 15.00 10.00 10.00 High-Level 30.00 23.70 24.00 0 to 20% of Cal. Span 0.00% 0.00% 0.00% 40 to 60% of Cal. Span 50.0% 42.2% 41.7% 100% of Cal. Span 100.0% 100.0% 100.0% Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration. CMA 15.00 10.00 10.00 Calibration Error Test Measured Concentration SO2 NOX CO CO2 O2 Low-Level 0.00 0.04 0.00 Mid-Level 15.01 10.04 10.10 High-Level 29.98 23.73 24.00 Enter Up-scale Analyzer Response to be used during testing. ACE Eq. 7E-1 15.01 10.04 10.10 Low-Level 0.00% 0.17% 0.00% ppmv Difference 0 0.04 0 Status Passed Cal. Passed Cal.Passed Cal. Mid-Level 0.03% 0.17% 0.42% ppmv Difference 0.01 0.04 0.1 Status Passed Cal. Passed Cal.Passed Cal. High-Level 0.07% 0.13% 0.00% ppmv Difference 0.02 0.03 0 Status Passed Cal. Passed Cal.Passed Cal. Pre-Test Sampling System Bias Initial Values SO2 NOX CO CO2 O2 CO - Low-Level 0.05 0.04 0.01 System Bias. SBi - Zero Bias TRUE 0.17% TRUE 0.00% 0.04%± 5% of Span Difference TRUE 0.05 TRUE 0 0.01 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 14.98 9.90 10.02 SBi - Up-Scale Bias TRUE 0.10% TRUE 0.59% 0.33% Difference TRUE 0.03 TRUE 0.14 0.08 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Raw Test Data Time Start Stop Test Date:1/10/2024 SO2 SO2 NOX CO CO2 O2 NOX 4.2 5.3 11.5 CO 0.0% 13.9% 0.0% 22.5% 48.0% CO2/O2 Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100 Final Values SO2 NOX CO CO2 O2 CO - Low-Level 0.05 0.03 0.00 System Bias. SBi - Zero Bias TRUE 0.17% TRUE 0.04% 0.00%± 5% of Span Difference TRUE 0.1 TRUE 0.0 0.0 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 15.01 9.89 9.98 SBi - Up-Scale Bias TRUE 0.00% TRUE 0.63% 0.50% Difference TRUE 0.0 TRUE 0.1 0.1 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Calibration Drift % of Span - D=ABS(SBf - SBi) Low-Level Drift TRUE 0.00% TRUE 0.04% 0.04% Response Spec. Difference TRUE 0.0 TRUE 0.0 0.0 3% of Span Pass or Re-Calibrate Pass Pass Pass Up-scale Gas Drift TRUE 0.10% TRUE 0.04% 0.17% Difference TRUE 0.0 TRUE 0.0 0.0 Pass or Re-Calibrate Pass Pass Pass Unit 7 Flow & Moisture As ft^2 Pbar Pq (static) Ps Avg Ts F CO2 - FCO2 O2 N2+C Md Ms 5.59 0.00 0.00 0.00 5.38 11.53 83.09 29.32 29.32 Y Cp Vm cf Vlc AVG Tm F Vm std Vw std Bws S Bws 0.0000 #DIV/0! 0.999 Load - Megawatts Avg. √∆P's Vs Qsw scfh wet Qa acfm Qsd dscfh Heat Input Btu/hr Low Mid High 21.64575 Enert > #1 - Times Date Point No.∆P √∆P ts F tm F (in) tm F (out) Final Vf Initial Vi 1 2 3 4 5 6 FT``` 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Failed Bias Dialog Failed Cal Error Dialog Failed Drift Dialog Failed Bias Dialog NOx Gen 9 2024 Reference Methods 2, 3A, 6C, 7E, 10, & 19 Source Information Company Name University of Utah Company Contact:Bryan Cracroft Contact Phone No.(801) 585-1617 Stack Designation:Boiler 9 Test & Review Dates Test Date:1/9/2024 & Review Date: 2/29/2024 Observer:Unobserved Reviewer:Paul Morris Emission Limits Emission Rates SO2 NOX CO SO2 NOX CO lbs./MMBtu lbs./hr. 0.8 0.276 ppm 9.0 8.233 Percent %O2 Correction as a whole #3.00 Test Information Heat Input Stack I.D. inches As ft^2 Y Dl H @ Cp Pbar Pq (static) fuel flow rate (Btu/hr.) Heat Input (Btu/hr.) 35.00 6.681 Contractor Information Contact: Charles Horton Contracting Company: Alliance Technical Group, LLC Address: 3683 W 2270 S, Suite E West Valley City, UT 84120 Phone No.: (464) 352-7568 Project No.: 8710 Round Division of Air Quality Instrumental Reference Methods - Gaseous Measurements Method 19 - F factors for Coal, Oil, and Gas Fd Fw Fc scf/MMBtu scf/MMBtu scf/MMBtu Diluent F factor used O2 CO2 Anthrocite 2 Bituminous 2 Lignite Natural Propane Butane 10100 COAL OIL GAS 9780 9860 9190 8710 8710 8710 10540 10640 11950 320 10610 10200 10390 1970 1800 1910 1420 1040 1190 1250 Wet CEM Correct For O2 CO2 Interference w/CO Yes Yes Yes NOx Gen 9 2024 Division of Air Quality NSPS Relative Accuracy Performance Specification Test - CEMS Certification University of Utah Boiler 9 Average Emission Dry SO2 NOX CO lbs./MMbtu 0.010 Average % concentration lbs./hr.0.28 CO2 O2 ppm corrected for %O2 8.23 5.21 11.86 Run 1 Enter O2 or CO2 Dry SO2 NOX CO CO2 O2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)9.77E-03 E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft 4.909E-07 lbs./hr.0.30 5.28 11.75 ppm corrected for %O2 8.04 5.24 11.73 Run 2 Dry SO2 NOX CO CO2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)1.01E-02 E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft 5.016E-07 lbs./hr.0.27 5.20 11.86 ppm corrected for %O2 8.31 5.24 11.83 Raw Value Run 3 Dry SO2 NOX CO CO2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)1.01E-02 E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft 4.979E-07 lbs./hr.0.26 5.16 11.96 ppm corrected for %O2 8.35 5.10 11.92 Raw Value Run 4 Dry SO2 NOX CO CO2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft lbs./hr. ppm corrected for %O2 Raw Value Run 5 Dry SO2 NOX CO CO2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft lbs./hr. ppm corrected for %O2 Raw Value C For Cal Drift Raw Value C For Cal Drift C For Cal Drift C For Cal Drift C For Cal Drift O2 CO2 Clear lbs./MMBTU NOx Gen 9 2024 Calibration Error Test Test Date January 9, 2024 O2 CS - Cal. Span 24.00 Units % Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 0.00 0.00 0.00% Passed Cal. RR03384 10/19/29 Mid-level 10.00 10.10 0.10 0.42% Passed Cal. High-level 24.00 24.02 0.02 0.08% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of CS - Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 41.67% 100% of Cal. Span High-level 100.00% Test Date January 9, 2024 CO2 CS - Cal. Span 23.70 Units % Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 0.03 0.03 0.127% Passed Cal. RR03384 10/19/29 Mid-level 10.00 10.05 0.05 0.211% Passed Cal. High-level 23.70 23.75 0.05 0.211% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 42.19% 100% of Cal. Span High-level 100.00% Test Date SO2 CS - Cal. Span Units ppm Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level Mid-level High-level % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 40 to 60% of Cal. Span Mid-level 100% of Cal. Span High-level Test Date January 9, 2024 NOx CS - Cal. Span 30.00 Units ppm Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 0.01 0.01 0.033% Passed Cal. CC723464 05/17/29 Mid-level 15.00 15.03 0.03 0.100% Passed Cal. High-level 30.00 30.20 0.20 0.667% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 50.00% 100% of Cal. Span High-level 100.00% Test Date CO CS - Cal. Span Units ppm Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level Mid-level High-level % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 40 to 60% of Cal. Span Mid-level 100% of Cal. Span High-level Valid Cal Gas Valid Cal Gas Valid Cal Gas NOx Gen 9 2024 Division of Air Quality Stack Test Review of University of Utah SO2 NOX CO CO2 O2 Boiler 9 CS Calibration Span 30.00 23.70 24.00 Units ppm ppm ppm % % Unprotected CV - Cylinder Value: SO2 NOX CO CO2 O2 Low-Level 0.00 0.00 0.00 Mid-Level 15.00 10.00 10.00 High-Level 30.00 23.70 24.00 0 to 20% of Cal. Span 0.00% 0.00% 0.00% 40 to 60% of Cal. Span 50.0% 42.2% 41.7% 100% of Cal. Span 100.0% 100.0% 100.0% Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration. CDir CMA 15.00 10.00 10.00 Calibration Error Test Cs - Measured Concentration SO2 NOX CO CO2 O2 Low-Level 0.01 0.03 0.00 Mid-Level 15.03 10.05 10.10 High-Level 30.20 23.75 24.02 Enter Up-scale Analyzer Response to be used during testing. ACE Eq. 7E-1 15.03 10.05 10.10 Low-Level 0.03% 0.13% 0.00% ppmdv Difference 0.01 0.03 0 Status Passed Cal. Passed Cal.Passed Cal. Mid-Level 0.10% 0.21% 0.42% ppmdv Difference 0.03 0.05 0.1 Status Passed Cal. Passed Cal.Passed Cal. High-Level 0.67% 0.21% 0.08% ppmdv Difference 0.2 0.05 0.02 Status Passed Cal. Passed Cal.Passed Cal. Pre-Test Sampling System Bias Initial Values SO2 NOX CO CO2 O2 CO - Low-Level 0.01 0.04 0.00 System Bias. SBi - Zero Bias TRUE 0.00% TRUE 0.04% 0.00%± 5% of Span Difference TRUE 0 TRUE 0.01 0 Pass or Failed Invalid Run Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 15.08 9.90 9.99 SBi - Up-Scale Bias TRUE 0.17% TRUE 0.63% 0.46% Difference TRUE 0.05 TRUE 0.15 0.11 Pass or Failed Invalid Run Passed Cal. Passed Cal. Passed Cal. Raw Test Data Time Start Stop Test Date:1/9/2024 SO2 SO2 NOX CO CO2 O2 NOX 4.1 5.2 11.7 CO 0.0% 13.8% 0.0% 22.1% 48.9% CO2/O2 Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100 Final Values SO2 NOX CO CO2 O2 CO - Low-Level 0.00 0.05 0.00 System Bias. SBi - Zero Bias TRUE 0.03% TRUE 0.08% 0.00%± 5% of Span Difference TRUE 0.0 TRUE 0.0 0.0 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 15.04 9.88 9.98 SBi - Up-Scale Bias TRUE 0.03% TRUE 0.72% 0.50% Difference TRUE 0.0 TRUE 0.2 0.1 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Calibration Drift % of Span - D=ABS(SBf - SBi) Low-Level Drift TRUE 0.03% TRUE 0.04% 0.00% Drift Difference TRUE 0.0 TRUE 0.0 0.0 3% of Span Pass or Re-Calibrate Pass Pass Pass Up-scale Gas Drift TRUE 0.13% TRUE 0.08% 0.04% Difference TRUE 0.0 TRUE 0.0 0.0 Pass or Re-Calibrate Pass Pass Pass Boiler 9 Flow & Moisture As ft^2 Pbar Pq (static) Ps Avg Ts F CO2 - FCO2 O2 N2+C Md Ms 6.681 0.00 0.00 0.00 5.28 11.75 82.98 29.31 29.31 Y Cp Vm cf Vlc AVG Tm F Vm std Vw std Bws S Bws #NUM! 0.0000 #DIV/0! 0.999 Load - Megawatts Avg. √∆P's Vs (ft/sec.)Qsw scfh wet Qa acfm Qsd dscfh Heat Input Btu/hr Low Mid High 30.2652 Enert > #1 - Times Date Point No.∆P √∆P ts F tm F (in) tm F (out) Final Vf Initial Vi 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Failed Bias Dialog Failed Drift Dialog Failed Cal Error Dialog CO Calibration Gas Failed Bias Dialog NOx Gen 9 2024 Division of Air Quality Stack Test Review of University of Utah SO2 NOX CO CO2 O2 Boiler 9 CS Calibration Span 30.00 23.70 24.00 Units ppm ppm ppm % % CV - Cylinder Value:SO2 NOX CO CO2 O2 Low-Level 0.00 0.00 0.00 Mid-Level 15.00 10.00 10.00 High-Level 30.00 23.70 24.00 0 to 20% of Cal. Span 0.00% 0.00% 0.00% 40 to 60% of Cal. Span 50.0% 42.2% 41.7% 100% of Cal. Span 100.0% 100.0% 100.0% Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration. CMA 15.00 10.00 10.00 Calibration Error Test Measured Concentration SO2 NOX CO CO2 O2 Low-Level 0.01 0.03 0.00 Mid-Level 15.03 10.05 10.10 High-Level 30.20 23.75 24.02 Enter Up-scale Analyzer Response to be used during testing. ACE Eq. 7E-1 15.03 10.05 10.10 Low-Level 0.03% 0.13% 0.00% ppmdv Difference 0.01 0.03 0 Status Passed Cal. Passed Cal.Passed Cal. Mid-Level 0.10% 0.21% 0.42% ppmdv Difference 0.03 0.05 0.1 Status Passed Cal. Passed Cal.Passed Cal. High-Level 0.67% 0.21% 0.08% ppmdv Difference 0.2 0.05 0.02 Status Passed Cal. Passed Cal.Passed Cal. Pre-Test Sampling System Bias Initial Values SO2 NOX CO CO2 O2 CO - Low-Level 0.00 0.05 0.00 System Bias. SBi - Zero Bias TRUE 0.03% TRUE 0.08% 0.00%± 5% of Span Difference TRUE 0.01 TRUE 0.02 0 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 15.04 9.88 9.98 SBi - Up-Scale Bias TRUE 0.03% TRUE 0.72% 0.50% Difference TRUE 0.01 TRUE 0.17 0.12 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Raw Test Data Time Start Stop Test Date:1/9/2024 SO2 SO2 NOX CO CO2 O2 NOX 4.2 5.2 11.8 CO 0.0% 14.0% 0.0% 21.8% 49.3% CO2/O2 Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100 Final Values SO2 NOX CO CO2 O2 CO - Low-Level 0.00 0.04 0.00 System Bias. SBi - Zero Bias TRUE 0.03% TRUE 0.04% 0.00%± 5% of Span Difference TRUE 0.0 TRUE 0.0 0.0 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 15.04 9.87 9.97 SBi - Up-Scale Bias TRUE 0.03% TRUE 0.76% 0.54% Difference TRUE 0.0 TRUE 0.2 0.1 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Calibration Drift % of Span - D=ABS(SBf - SBi) Low-Level Drift TRUE 0.00% TRUE 0.04% 0.00% Response Spec. Difference TRUE 0.0 TRUE 0.0 0.0 3% of Span Pass or Re-Calibrate Pass Pass Pass Up-scale Gas Drift TRUE 0.00% TRUE 0.04% 0.04% Difference TRUE 0.0 TRUE 0.0 0.0 Pass or Re-Calibrate Pass Pass Pass Boiler 9 Flow & Moisture As ft^2 Pbar Pq (static) Ps Avg Ts F CO2 - FCO2 O2 N2+C Md Ms 6.68 0.00 0.00 0.00 5.20 11.86 82.94 29.31 29.31 Y Cp Vm cf Vlc AVG Tm F Vm std Vw std Bws S Bws 0.0000 #DIV/0! 0.999 Load - Megawatts Avg. √∆P's Vs Qsw scfh wet Qa acfm Qsd dscfh Heat Input Btu/hr Low Mid High 27.13515 Enert > #1 - Times Date Point No.∆P √∆P ts F tm F (in) tm F (out) Final Vf Initial Vi 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Failed Bias Dialog Failed Drift Dialog Failed Cal Error Dialog Failed Bias Dialog NOx Gen 9 2024 Division of Air Quality Stack Test Review of University of Utah SO2 NOX CO CO2 O2 Boiler 9 CS Calibration Span 30.00 23.70 24.00 Units ppm ppm ppm % % CV - Cylinder Value:SO2 NOX CO CO2 O2 Low-Level 0.00 0.00 0.00 Mid-Level 15.00 10.00 10.00 High-Level 30.00 23.70 24.00 0 to 20% of Cal. Span 0.00% 0.00% 0.00% 40 to 60% of Cal. Span 50.0% 42.2% 41.7% 100% of Cal. Span 100.0% 100.0% 100.0% Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration. CMA 15.00 10.00 10.00 Calibration Error Test Measured Concentration SO2 NOX CO CO2 O2 Low-Level 0.01 0.03 0.00 Mid-Level 15.03 10.05 10.10 High-Level 30.20 23.75 24.02 Enter Up-scale Analyzer Response to be used during testing. ACE Eq. 7E-1 15.03 10.05 10.10 Low-Level 0.03% 0.13% 0.00% ppmv Difference 0.01 0.03 0 Status Passed Cal. Passed Cal.Passed Cal. Mid-Level 0.10% 0.21% 0.42% ppmv Difference 0.03 0.05 0.1 Status Passed Cal. Passed Cal.Passed Cal. High-Level 0.67% 0.21% 0.08% ppmv Difference 0.2 0.05 0.02 Status Passed Cal. Passed Cal.Passed Cal. Pre-Test Sampling System Bias Initial Values SO2 NOX CO CO2 O2 CO - Low-Level 0.00 0.04 0.00 System Bias. SBi - Zero Bias TRUE 0.03% TRUE 0.04% 0.00%± 5% of Span Difference TRUE 0.01 TRUE 0.01 0 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 15.04 9.87 9.97 SBi - Up-Scale Bias TRUE 0.03% TRUE 0.76% 0.54% Difference TRUE 0.01 TRUE 0.18 0.13 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Raw Test Data Time Start Stop Test Date:1/9/2024 SO2 SO2 NOX CO CO2 O2 NOX 4.2 5.1 11.9 CO 0.0% 13.9% 0.0% 21.5% 49.7% CO2/O2 Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100 Final Values SO2 NOX CO CO2 O2 CO - Low-Level 0.01 0.04 0.01 System Bias. SBi - Zero Bias TRUE 0.00% TRUE 0.04% 0.04%± 5% of Span Difference TRUE 0.0 TRUE 0.0 0.0 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 15.02 9.84 9.96 SBi - Up-Scale Bias TRUE 0.03% TRUE 0.89% 0.58% Difference TRUE 0.0 TRUE 0.2 0.1 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Calibration Drift % of Span - D=ABS(SBf - SBi) Low-Level Drift TRUE 0.03% TRUE 0.00% 0.04% Response Spec. Difference TRUE 0.0 TRUE 0.0 0.0 3% of Span Pass or Re-Calibrate Pass Pass Pass Up-scale Gas Drift TRUE 0.00% TRUE 0.13% 0.04% Difference TRUE 0.0 TRUE 0.0 0.0 Pass or Re-Calibrate Pass Pass Pass Boiler 9 Flow & Moisture As ft^2 Pbar Pq (static) Ps Avg Ts F CO2 - FCO2 O2 N2+C Md Ms 6.68 0.00 0.00 0.00 5.16 11.96 82.88 29.30 29.30 Y Cp Vm cf Vlc AVG Tm F Vm std Vw std Bws S Bws 0.0000 #DIV/0! 0.999 Load - Megawatts Avg. √∆P's Vs Qsw scfh wet Qa acfm Qsd dscfh Heat Input Btu/hr Low Mid High 25.40685 Enert > #1 - Times Date Point No.∆P √∆P ts F tm F (in) tm F (out) Final Vf Initial Vi 1 2 3 4 5 6 FT``` 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Failed Bias Dialog Failed Cal Error Dialog Failed Drift Dialog Failed Bias Dialog