Loading...
HomeMy WebLinkAboutDERR-2024-004479 195 North 1950 West • Salt Lake City, UT Mailing Address: P.O. Box 144840 • Salt Lake City, UT 84114-4840 Telephone (801) 536-4100 • Fax (801) 359-8853 • T.D.D. (801) 536-4284 www.deq.utah.gov Printed on 100% recycled paper State of Utah SPENCER J. COX Governor DEIDRE HENDERSON Lieutenant Governor Department of Environmental Quality Kimberly D. Shelley Executive Director DIVISION OF ENVIRONMENTAL RESPONSE AND REMEDIATION Brent H. Everett Director ERRP-081-24 February 27, 2024 Kade Iverson Hi Petroleum, LLC P.O. Box 272 Glendale, Utah 84729 Re: Notice of Certificate of Compliance Hi Petroleum, located at 182 South Main Street, Hatch, Utah Facility Identification No. 6000435 Dear Mr. Iverson: The Division of Environmental Response and Remediation (DERR) has received all the documentation necessary to issue the attached certificate of compliance for the 2,000-gallon non- ethanol, 8,000-gallon diesel, 8,000-gallon premium, and 8,000-gallon regular aboveground petroleum storage tanks at this facility. If you have additional questions, please contact Kim Viehweg, the DERR project manager, at (801) 536-4100. Sincerely, Brent H. Everett, Director Division of Environmental Response and Remediation BHE/KV/ta Enclosure: Certificate of Compliance cc: Jeremy Roberts, Environmental Health Director, Southwest Utah Public Health Department Paul Wright, District Engineer, Utah Department of Environmental Quality 2024 UST CERTIFICATE OF COMPLIANCE ISSUED TO:LOCATION OF TANKS: KADE IVERSON HI PETROLEUM HI PETROLEUM LLC 182 S MAIN P.O. BOX 272 HATCH UT 84735 GLENDALE, UT 84729 Facility ID: 6000435 Tank #Capacity Substance Desc Compliance Financial Assurance Mechanism 3 2000 Gasoline Yes PST Fund 4 8000 Diesel Yes PST Fund 5 8000 Gasoline Yes PST Fund 6 8000 Gasoline Yes PST Fund This certificate will automatically lapse if any of the required fees are not paid. It may also be revoked for failure to comply with state and federal UST regulations. Possession of this certificate does not signify coverage under the Utah PST Fund. Cleanup requirements may be obtained from the Division of Environmental Response and Remediation. UTAH DEPARTMENT OF ENVIRONMENTAL QUALITY Underground Storage Tank Inspection Verification Form Facility ID:6000435 Owner Name:HI PETROLEUM LLC Facility Name:HI PETROLEUM Owner Address:P.O. BOX 272 Street Address:182 S MAIN GLENDALE, UT 84729 HATCH, UT 84735 Operator A:No Data / No Data / Operator B:No Data / No Data / Owner Email:kade.iverson@gmail.com UTM Coordinates X/Y:373414 / 4167579 Disp ID/Alt ID Substance UDC Pipe Flex Loc Install Date UDC Install Date Fire Valve Sat Present UDC Test Disp Flex CP Test 1 - 1/2 Gas/Diesel Yes Steel Flex in Sump Yes No 2 - 3/4 Gas/Diesel Yes Steel Flex in Sump Yes No 3 - 5/6 Diesel Yes Steel Flex in Sump Yes No 4 - 7/8 Diesel Yes Steel Flex in Sump Yes No Tank ID/Alt ID:3 / 3 EGen/AST/Stat e: No / Yes / Yes Pipe Material-Mod:Flexible Plastic - Double-Walled Siphon/Compart:No / No PVV/StageI:Pipe Type/STP Cont:Pressurized / No Tank Status:Currently In Use STP Flex Connectors:Booted Steel Flex Installed/Cap/Loc:9/1/2019 / 2000 / South LLD Model: Substance Stored:Gasoline / Non-Ethanol Spill/Overfill/Sm deliv:5 gal. Per Prod. APST Cont. Sump / / No Tank Material-Mod:Asphalt Coated or Bare Steel - Double-Walled PST Fund/Other Type:No / ATG: / Tank/Pipe Rel Det:OTHER / OTHER / NONE ATG Specs: / / STP Sump Test:Spill Bk Test:11/04/2023 ATG Test:Overfill Test: LTT Test:LLD Test:CP Tank Test:CP Pipe Test: Tank ID/Alt ID:4 / 4 EGen/AST/Stat e: No / Yes / Yes Pipe Material-Mod:Flexible Plastic - Double-Walled Siphon/Compart:No / No PVV/StageI:Pipe Type/STP Cont:Pressurized / No Tank Status:Currently In Use STP Flex Connectors:Booted Steel Flex Installed/Cap/Loc:9/1/2019 / 8000 / South Center LLD Model: Substance Stored:Diesel / Diesel #2 (U.L.S.)Spill/Overfill/Sm deliv:5 gal. Per Prod. APST Cont. Sump / / No Tank Material-Mod:Asphalt Coated or Bare Steel - Secondary Containment PST Fund/Other Type:No / ATG: / Tank/Pipe Rel Det:OTHER / OTHER / NONE ATG Specs: / / STP Sump Test:Spill Bk Test:11/04/2023 ATG Test:Overfill Test: LTT Test:LLD Test:CP Tank Test:CP Pipe Test: Tank ID/Alt ID:5 / 5 EGen/AST/Stat e: No / Yes / Yes Pipe Material-Mod:Flexible Plastic - Double-Walled Siphon/Compart:No / No PVV/StageI:Pipe Type/STP Cont:Pressurized / No Tank Status:Currently In Use STP Flex Connectors:Booted Steel Flex Installed/Cap/Loc:9/1/2019 / 8000 / North Center LLD Model: Substance Stored:Gasoline / Premium Spill/Overfill/Sm deliv:5 gal. Per Prod. APST Cont. Sump / / No Tank Material-Mod:Asphalt Coated or Bare Steel - Secondary Containment PST Fund/Other Type:No / ATG: / Tank/Pipe Rel Det:OTHER / OTHER / NONE ATG Specs: / / STP Sump Test:Spill Bk Test:11/04/2023 ATG Test:Overfill Test: LTT Test:LLD Test:CP Tank Test:CP Pipe Test: Tank ID/Alt ID:6 / 6 EGen/AST/Stat e: No / Yes / Yes Pipe Material-Mod:Flexible Plastic - Double-Walled Siphon/Compart:No / No PVV/StageI:Pipe Type/STP Cont:Pressurized / No Tank Status:Currently In Use STP Flex Connectors:Booted Steel Flex Installed/Cap/Loc:9/1/2019 / 8000 / North LLD Model: Substance Stored:Gasoline / Regular Spill/Overfill/Sm deliv:5 gal. Per Prod. APST Cont. Sump / / No 2/20/2024 Page 1 of 2 Tank Material-Mod:Asphalt Coated or Bare Steel - Secondary Containment PST Fund/Other Type:No / ATG: / Tank/Pipe Rel Det:OTHER / OTHER / NONE ATG Specs: / / STP Sump Test:Spill Bk Test:11/04/2023 ATG Test:Overfill Test: LTT Test:LLD Test:CP Tank Test:CP Pipe Test: 2/20/2024 Page 2 of 2 ------------------------------------------------------