HomeMy WebLinkAboutDERR-2024-004447Utah Department of Environmental Quality - UST Release Detection TANK OWNERSHIP Name BLAKE RONEY Address 3187 N FOOTHILL DR PROVO, UT 84604 Contact BLAKE RONEY Phone Email mjs4mail@aol.com TANK LOCATION Name BLAKE RONEY RESIDENCE Address 3187 N FOOTHILL DR PROVO, UT 84604 A Operator MICHAEL SHANKS Phone (801) 376-4818 B Operator SAME Phone SAME Facility ID: 1000797 Inspection Date: 02/08/2024 DISPENSER DETAILS DISP ID/ALT ID SUBSTANCE UDC PIPE FLEX LOC INSTALL DATE UDC INSTALL DATE FIRE VALVE SAT PRESENT UDC TEST DISP FLEX CP TEST 1 - 1 Gasoline No Booted Steel Flex Jan. 26, 2001 None Yes No None None TANK DETAILS Tank ID/Alt ID 1 / 1 E-Gen/AST No / No Siphon/Compart No / No Tank Status Currently In Use Installed/Cap/Loc Jan. 26, 2001 / 2000 / Single Substance Stored Gasoline / Regular Tank Material- Mod Galvanic Cathodic Protection (STIP3)-Double-Walled ATG Veeder Root / TLS-300 CSLD No Manifold LTT Test None LLD Test None Pipe Material-Mod Fiberglass Reinforced Plastic / None Pipe type/STP Cont Safe Suction / No STP Flex Connectors Booted Steel Flex LLD Model Spill/Overfill/Sm Delivery 5 gal. Spill Bucket / Automatic shutoff / No PST Fund/Other Type Yes / None Tank/Pipe Rel Det TankATG PipeLDNotListed CP Tank Test Feb. 17, 2023 CP Pipe Test None INSPECTION COMMENTS Title: A/B has been renewed A/B has been renewed and paid. Just has not been updated in our system yet. No Photos 2024-02-08 Page 1 of 4 FACILITY RESPONSES The above accurately represents the facility's release detection records Yes Operator Training A Operator current?Yes B Operator current?Yes Monthly checklist available and complete?Yes Is the site unmanned?Yes Is a sign posted in a conspicuous area giving the name and telephone number of a person in case of an emergency and if the station is manned part of the time, are C operators trained? Yes Does the site have emergency shutoff device?Yes Cathodic Protection The results of the last two cathodic protection tests are available (within six months of installation and every three years thereafter)? Yes Financial Responsibility Financial responsibility method is ok?Yes TANK RESPONSES Tank 1 Spill/Overfill Tank has a spill prevention device?Yes Are you able to visually inspect the spill containment bucket(s) for functionality? (i.e. are the buckets clean enough to see cracks, etc?) Yes Is the spill containment bucket intact?Yes Is the spill containment bucket(s) able to contain a spill? (i.e. is there water, product, debris, etc in the spill bucket to prevent it from containing a spill?) Yes Tank has an overfill device?Yes Tank 1 ATG/IM ATG/IM - Records on site document that the system is properly installed, calibrated, operated, and maintained (system and tank setup reports, maintenance records)? Written documentation of calibration, maintenance, and repair is kept for at least one year after work is completed? Yes ATG/IM - ATG console or other equipment used to take readings and perform tests is adequate, accessible, and operational? Yes ATG/IM - Documentation of valid testing or monitoring is available (must have records for the two most recent months and 10 of last 12 months)? Show results in the RD tab. Yes ATG - The tank was filled to at least the minimum level required to ensure a valid leak test, and the tank size is within the allowed upper and lower size limits? Yes Tank 1 Cathodic Protection Tanks are protected from corrosion?Yes Piping is protected from corrosion?Yes Flex connectors at the tank sub-pumps are protected from corrosion?Yes Tank 1 Suction Piping Leak Detection Piping qualifies as Safe Suction. (Documentation is available and verifiable to show that piping operates at less than atmospheric pressure, has only one check valve (under pump), and has proper slope of piping. If all these criteria are met, no leak detection is required on the piping.) Yes Tank 1 Spill/Overfill Does the spill bucket have a valid 3- year test, valid monthly monitoring for DW buckets, or the tank is exempt? Yes Does the overfill device have a valid 3- year test or the tank is exempt?Yes 2024-02-08 Page 2 of 4 Tank 1 ATG/IM Does the ATG system have a valid annual test?Yes DISPENSER RESPONSES Dispenser 1 Flex connectors at the dispensers are protected from corrosion?Yes Fire valve is anchored properly?Yes Does the line tightness test port on the fire valve have the manufacturers plug installed in it? (no ball valves) Yes Is the fire valve located properly below grade?Yes Is the fire valve's fuseable link intact?Yes MONTHLY LEAK DETECTION MONITORING Feb '23 Mar '23 Apr '23 May '23 Jun '23 Jul '23 Aug '23 Sep '23 Oct '23 Nov '23 Dec '23 Jan '24 Tank 1 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Line Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl NON-COMPLIANCE ITEMS All items are in compliance. 2024-02-08 Page 3 of 4 Prepared by fueloperator.com Inspection Information Inspector:Lundell, Phillip Record Created:Feb. 8, 2024, 12:18 p.m. Inspection Date:Feb. 8, 2024 2024-02-08 Page 4 of 4