Loading...
HomeMy WebLinkAboutDDW-2024-006202 State of Utah SPENCER J. COX Governor DIEDRE HENDERSON Lieutenant Governor Department of Environmental Quality Kimberly D. Shelley Executive Director DIVISION OF DRINKING WATER Nathan Lunstad Director January 24, 2024 Tom Ward Sandy City Water System 9150 S 150 E Sandy, UT 84070 Subject: Notice of Source Deactivation for Sandy City Water System; UTAH1802 Tom Ward: This letter serves as notification that the Division of Drinking Water (the Division) has changed the activity status of the following sources from “Active” to “Inactive”:  Flat Iron Well (identified as WS036) The listed sources are now considered inactive and are not allowed to be utilized as a source of drinking water until they have been formally reactivated. In most cases the reactivation process involves only collecting the outstanding samples that were missed during the source’s period of inactivity. The reactivation process does not require that systems obtain new operating permits. As of January 24, 2024, the following samples will need to be collected and reviewed by the Division prior to placing the source back online. Facility Name Facility ID Samples Needed for Reactivation Flat Iron Well WS036 Nitrate Flat Iron Well WS036 Pesticides Flat Iron Well WS036 RADs - Compliance Flat Iron Well WS036 Volatile Organics This decision was made after Karen Hoagland notified the Division on January 23, 2023 that the source was inactive during its full operational period. To avoid issuing a monitoring violation and to ensure that the samples required under R309-205 are collected, the listed sources have been deactivated. Tom Ward Page 2 of 2 January 24, 2024 195 North 1950 West • Salt Lake City, UT Mailing Address: P.O. Box 144830 • Salt Lake City, UT 84114-4830 Telephone (801) 536-4200 • Fax (801) 536-4211 • T.D.D. (801) 536-4414 www.deq.utah.gov Printed on 100% recycled paper When the system would like to utilize the listed sources again, please contact David Kruse at dbkruse@utah.gov or 385-566-7789 to initiate the source reactivation process. Thank you for your efforts in maintaining a safe drinking water system. Sincerely, Mark Berger Monitoring and Standards Section Manager Enclosure: System Inventory Report cc: Tom Ward, Sandy City Water System, tward@sandy.utah.gov Fuaad Hararah, SALT LAKE VALLEY HEALTH DEPT, fhararah@slco.org Mark Berger, Division of Drinking Water, mberger@utah.gov David Kruse, Division of Drinking Water, dbkruse@utah.gov Utah Department Of Environmental Quality Division Of Drinking Water Admin Contacts Inventory Report Service Connections Treatment Plants SANDY CITY WATER SYSTEM PWS ID: UTAH18028 Rating: Approved 03/11/1980 Active Legal Contact SANDY CITY WATER SYSTEM TOM WARD 9150 S 150 E SANDY, UT 84070 Phone: 801-568-7193 County: SALT LAKE COUNTY System Type: Community Population: 99,750 Site Updates Last Inventory Update: 01/17/2024 Last Surveyor Update: 10/05/2023 Surveyor: PETER T KEERS Operating Period: 1/1 - 12/31 Last IPS Update: 01/23/2024 14:10:00 Consumptive Use Zone Irrigation Zone: 4 Date: 02/15/2013 Name Title Office Emergency Email WARD, TOM 801-243-5609 tward@sandy.utah.gov Type Meter Type Meter Size # Of Connections Residential Metered 0 23956 Commercial Metered 0 1860 Total Service Connections: 25816 ID Plant Name Bin Status Date Design Cap Status TP002 COPPERVIEW (EQPMNT TRANSFER'D TO TP015)0 Inactive Treatment Purposes TP004 GRANITE MESA FLUORIDATOR Inactive Treatment Purposes FLUORIDATION TP015 PALMER FLUORIDATOR + CHLORINATOR Inactive Treatment Purposes FLUORIDATION, TABLET HYPOCHLORINATION, POST TP017 CEMETARY FLUORIDATOR ABANDONED 0 Inactive Treatment Purposes FLUORIDATION TP018 CANYON VILLAGE CHLORINATOR + FLUORIDE 0 Inactive Treatment Purposes FLUORIDATION, TABLET HYPOCHLORINATION, POST DEQ | Drinking Water Run Date: 01/23/2024 23:49:26 | Rating: Approved UTAH18028 SANDY CITY WATER SYSTEM page 1 of 6 Storage TP019 CROWTON SPRING CHLORINATOR (REMOVED)Inactive Treatment Purposes GASEOUS CHLORINATION, POST TP021 BICENTENIAL CHLORINATOR + FLUORIDE 0 Inactive Treatment Purposes FLUORIDATION, TABLET HYPOCHLORINATION, POST TP023 WILDFLOWER FLUORIDATOR 0 Inactive Treatment Purposes FLUORIDATION TP027 RICHARDS DITCH CHLORINATOR + FLUORIDE 0 Inactive Treatment Purposes FLUORIDATION, GASEOUS CHLORINATION, POST TP028 ALTA CANYON FLUORIDATOR 0 Inactive Treatment Purposes FLUORIDATION TP030 PEPPERWOOD CHLORINATOR + FLUORIDE 0 Inactive Treatment Purposes FLUORIDATION, TABLET HYPOCHLORINATION, POST TP031 BRANDON PARK WELL FLUORIDATOR 0 Inactive Treatment Purposes FLUORIDATION TP032 DIMPLE DELL WELL FLUORIDATOR 0 Inactive Treatment Purposes FLUORIDATION TP034 LONE HOLLOW FLUORIDATIOR 0 Inactive Treatment Purposes FLUORIDATION TP035 PARADISE VALLEY FLUORIDATOR 0 Inactive Treatment Purposes FLUORIDATION TP036 SEVERSON CHLORINATOR + FLUORIDE Active Treatment Purposes FLUORIDATION, TABLET HYPOCHLORINATION, POST TP037 FLAT IRON CHLORINATOR Active Treatment Purposes TABLET HYPOCHLORINATION, POST TP038 PARADISE VALLEY WELL CHLORINATOR Proposed Treatment Purposes DEQ | Drinking Water Run Date: 01/23/2024 23:49:26 | Rating: Approved UTAH18028 SANDY CITY WATER SYSTEM page 2 of 6 Pumping Stations Sources ID Name Type Effective Volume Material Status Status Reason ST012 FLAT IRON 5MG TANK Ground 5,000,000 GAL Concrete Active Op Issued - Check ST011 GRANITE TANK Ground 5,000,000 GAL Concrete Active Op Issued - Check ST010 FLAT IRON WEST STORAGE (REPLACED) Ground 2,000,000 GAL Steel Inactive Replaced ST001 A-1 TANK Ground 650,000 GAL Concrete Active ST002 HIGH BENCH TANK Ground 4,500,000 GAL Concrete Active ST003 GRANITE TANK (ABANDONED)Ground 5,000,000 GAL Steel Inactive Abandoned ST004 PEPPERWOOD STORAGE Ground 3,000,000 GAL Concrete Active ST005 HAND TANK Ground 4,000,000 GAL Concrete Active ST006 SOUTHEAST TANK Ground 4,000,000 GAL Concrete Active ST007 ZONE 5 TANK Ground 8,000,000 GAL Concrete Active ST008 GRANITE MESA TANK Ground 3,000,000 GAL Concrete Active ST009 FLAT IRON EAST STORAGE (REPLACED) Ground 2,000,000 GAL Steel Inactive Replaced Total Effective Volume: 37,150,000 GAL ID Station Name Status Reason Capacity Availability PF001 A-1 BOOSTER STATION - ABANDONED Inactive Abandoned PF002 BOOSTER #1 BOOSTER STATION Active Permanent PF003 BOOSTER #2 (ABANDONED)Inactive Abandoned PF004 GRANITE MESA BOOSTER STATION Active Permanent PF005 HIGH BENCH BOOSTER Active Op Issued - Check Permanent PF006 METRO BOOSTER Active Permanent PF007 PALMER (FALCON PARK) BOOSTER Active Permanent PF008 PEPPERWOOD BOOSTER PUMP Active Permanent PF009 A-1 BOOSTER STATION Active Permanent Total Capacity: 0 null ID Source Name OP Date Status Reason Source Type Water Type Period Of Op WS001 CITY HALL WELL (ABANDONED) Inactive Abandoned Well Groundwater Flow Flow Rate UOM SYLD 700 GPM WS002 COPPERVIEW WELL (ABANDONED) Inactive Abandoned Well Groundwater 4/1 - 9/30 Flow Flow Rate UOM PUMP 1,860 GPM SYLD 1,900 GPM WS003 FLAT IRON # 2 WELL (ABANDONED) Inactive Abandoned Well Groundwater Flow Flow Rate UOM SYLD 470 GPM DEQ | Drinking Water Run Date: 01/23/2024 23:49:26 | Rating: Approved UTAH18028 SANDY CITY WATER SYSTEM page 3 of 6 WS004 GRANITE MESA WELL 05/02/2012 Inactive ERROR:SB Well Groundwater Flow Flow Rate UOM SYLD 1,350 GPM PUMP 1,200 GPM WS005 MT JORDAN WELL ABANDONED Inactive Abandoned Well Groundwater WS006 BIG CANYON WELL Inactive ERROR:SB Well Groundwater 7/1 - 9/30 Flow Flow Rate UOM PUMP 800 GPM SYLD 700 GPM WS007 SMALL CANYON WELL Inactive ERROR:SB Well Groundwater 4/1 - 7/31 Flow Flow Rate UOM PUMP 550 GPM SYLD 450 GPM WS008 OLD PEPPERWOOD ABANDONED Inactive Abandoned Well Groundwater Flow Flow Rate UOM PUMP 2,600 GPM WS009 GREENWOOD WELL ABANDONED Inactive Abandoned Well Groundwater WS010 ROBINSON WELL STAND BY Inactive ERROR:SB Well Groundwater 4/1 - 9/30 Flow Flow Rate UOM PUMP 600 GPM SYLD 840 GPM WS011 PHILLIPS WELL (SOLD)Inactive Sold/Transferred Well Groundwater Flow Flow Rate UOM PUMP 550 GPM SYLD 500 GPM WS012 SEVERSEN WELL 2 03/13/2013 Inactive ERROR:SB Well Groundwater Flow Flow Rate UOM PUMP 2,850 GPM SYLD 2,000 GPM TYLD 3,000 GPM WS013 HAUN WELL ABANDONED Inactive Abandoned Well Groundwater WS014 UTAH18027 JORDAN VALLEY WCD Active Consecutiv e Connection Surfacewater 1/1 - 12/31 WS015 PALMER WELL 05/02/2012 Inactive ERROR:SB Well Groundwater 7/1 - 9/30 Flow Flow Rate UOM PUMP 1,766 GPM SYLD 2,040 GPM WS016 PROWSWOOD WELL SOLD Inactive Sold/Transferred Well Groundwater Flow Flow Rate UOM PUMP 450 GPM SYLD 900 GPM WS017 CEMETERY WELL Inactive Abandoned Well Groundwater DEQ | Drinking Water Run Date: 01/23/2024 23:49:26 | Rating: Approved UTAH18028 SANDY CITY WATER SYSTEM page 4 of 6 Flow Flow Rate UOM PUMP 1,500 GPM SYLD 1,600 GPM WS018 CANYON VILLAGE WELL 02/24/2017 Inactive ERROR:SB Well Groundwater 7/1 - 9/30 Flow Flow Rate UOM PUMP 1,700 GPM SYLD 1,850 GPM WS019 CROWTON SPRING Inactive Abandoned Spring Groundwater WS020 FLAT IRON MESA WELL ABANDONED Inactive Abandoned Well Groundwater WS021 BICENTENNIAL WELL 07/09/2013 Inactive ERROR:SB Well Groundwater Flow Flow Rate UOM PUMP 2,600 GPM SYLD 3,000 GPM WS022 COUNTY PARK WELL ABANDONED Inactive Abandoned Well Groundwater WS023 WILDFLOWER WELL Inactive ERROR:SB Well Groundwater Flow Flow Rate UOM PUMP 1,750 GPM SYLD 2,150 GPM WS024 HILLSHIRE WELL ABANDONED Inactive Abandoned Well Groundwater WS025 DAVIDSON WELL ABANDONED Inactive Abandoned Well Groundwater WS026 LITTLE COTTONWOOD WELL Inactive Well Groundwater 4/1 - 9/30 Flow Flow Rate UOM PUMP 1,200 GPM SYLD 3,000 GPM WS027 RICHARDS DITCH WELL (SOLD/TRANSFERRED) 07/28/2009 Inactive Sold/Transferred Well Groundwater 7/1 - 9/30 Flow Flow Rate UOM SYLD 2,100 GPM WS028 ALTA CANYON WELL Inactive ERROR:SB Well Groundwater 5/1 - 9/30 Flow Flow Rate UOM PUMP 1,700 GPM SYLD 1,400 GPM WS029 UTAH18016 METROPOLITAN WATER DISTRICT Active Consecutiv e Connection Surfacewater 1/1 - 12/31 WS030 PEPPERWOOD WELL 07/29/2014 Inactive ERROR:SB Well Groundwater Flow Flow Rate UOM PUMP 2,100 GPM SYLD 2,200 GPM WS031 BRANDON PARK WELL Inactive ERROR:SB Well Groundwater 4/1 - 9/30 Flow Flow Rate UOM PUMP 900 GPM SYLD 800 GPM DEQ | Drinking Water Run Date: 01/23/2024 23:49:26 | Rating: Approved UTAH18028 SANDY CITY WATER SYSTEM page 5 of 6 Site Visit History WS032 DIMPLE DELL WELL 05/13/2005 Inactive ERROR:SB Well Groundwater 4/1 - 9/30 Flow Flow Rate UOM PUMP 4,200 GPM SYLD 4,000 GPM WS033 PLAYER ROAD WELL (NOT EQUIPPED) Inactive Well Groundwater WS034 LONE HOLLOW WELL Inactive Well Groundwater 4/1 - 9/30 Flow Flow Rate UOM PUMP 1,500 GPM SYLD 1,550 GPM WS035 PARADISE VALLEY WELL 05/13/2005 Inactive Well Groundwater 7/1 - 9/30 Flow Flow Rate UOM PUMP 2,200 GPM SYLD 2,000 GPM WS036 FLAT IRON WELL Inactive Emergency Well Groundwater 7/1 - 9/30 Flow Flow Rate UOM SYLD 2,000 GPM Date Visited Survey Type Surveyor Notified Date Next Inspection 02/18/2003 Sanitary Survey, Finished SURVEYOR, DDW 10/29/2007 Sanitary Survey, Finished WILLIAMS, RANDY S 12/19/2007 09/30/2015 10/05/2010 Sanitary Survey, Finished GONZALES, SHAWN 11/04/2010 09/30/2015 10/10/2014 Sanitary Survey, Finished DEV, NAGENDRA 10/10/2014 10/03/2017 Sanitary Survey, Finished BENAVIDEZ, LILIANA 11/02/2017 07/07/2020 Sanitary Survey, Finished NEWBERRY, MICHAEL 07/28/2020 10/05/2023 Sanitary Survey, Finished KEERS, PETER T 11/24/2023 DEQ | Drinking Water Run Date: 01/23/2024 23:49:26 | Rating: Approved UTAH18028 SANDY CITY WATER SYSTEM page 6 of 6